3RHP Series DC Control te • 100K-cycle UL508 Endurance Rating for Enhanced Reliability • 40 and 50A output • Voltage ratings to 240 VAC • Lifetime 2 million operations at full load • LED input status indicator • Wire, lug or quick connect termination • Industry Standard DP contactor mounting PRODUCT SELECTION (by control voltage and output rating) 4.5-5.5 VDC 10-15 VDC 22-27 VDC 40A 120 VAC 50A 120 VAC 40A 240 VAC 50A 240 VAC 3RHP1240D5 3RHP1240D12 3RHP1240D24 3RHP1250D5 3RHP1250D12 3RHP1250D24 3RHP2440D5 3RHP2440D12 3RHP2440D24 3RHP2450D5 3RHP2450D12 3RHP2450D24 ol e Control Voltage OUTPUT SPECIFICATIONS (voltage) Description Operating Voltage (47-63Hz) [Vrms] Maximum Off-State Leakage Current per channel 120 VAC 240 VAC 100-120 0.05 mA @ 120 VAC 208-240 0.06 mA @ 240 VAC OUTPUT SPECIFICATIONS (current) Description 40A 50A Maximum Load Current per phase @ 40°C [Arms] (1) 40A Resistive Power terminals 1/4" Quick Connect and 10x32 binder head screws Wire Size 8-14 AWG 50A Resistive 1/4" Quick Connect and box lugs 6-14 AWG bs INPUT SPECIFICATIONS Description Coil Voltage Max. Reverse Voltage Input Current Min. Turn-On Voltage Min. Turn-Off Voltage SUFIX D5 SUFIX D12 SUFIX D24 4.5-5.5 VDC -5.5 VDC 12mA @ 5 VDC 4.5 VDC 1 VDC 10-15 VDC -15.5 VDC 12mA @ 12 VDC 9.5 VDC 2 VDC 22-27 VDC -27.5 VDC 12mA @ 24 VDC 9.5 VDC 2 VDC GENERAL SPECIFICATIONS Description O Dielectric Strength, Input to Output Dielectric Strength, Input/Output to ground Contacts (2) Ambient Operating Temperature Range (3) Ambient Storage Temperature Range Max. Turn-On Time 50/60 Hz Max. Turn-Off Time 50/60Hz Maximum Number of Operations Lifetime Number of Operations @ Rated Current (4) Weight (typical) Screw Torque (input/Output) 40A Screw Torque (input/Output) 50A Parameters 4000 Vrms 2500 Vrms Three Normally Open -20 to 75 °C -40 to 100 °C 20 ms / 16.6 ms 40 ms / 32 ms 30 per Minute > 2 Million 1.19 lbs (540 g) 4.4-5 in lb (0.5-0.6 Nm) / 15-18 in lb (1.7-2.1 Nm) 4.4-5 in lb (0.5-0.6 Nm) / 20-25 in lb (2.2-2.9 Nm) GENERAL NOTES (1) (2) (3) (4) See Derating curves for additional operating conditions. The RHP includes a Solid State Relay, therefore electrical isolation is not provided. The RHP includes over temperature protection for the solid state relay. 40°C ambient temperature, 30 operations/min, maximum voltage control. bs ol e te MECHANICAL SPECIFICATIONS O THERMAL DERATE INFORMATION bs ol e te TYPICAL ELECTRICAL CONNECTIONS O AGENCY APPROVALS UL/cUL UL508, E116950 EN60950-1-2006 Rev.073011 O bs ol e te ACCESSORIES O te ol e bs O bs ol e te ANNEX - ENVIROMENTAL INFORMATION