HIGH PERFORMANCE IEC SERIES CONNECTOR FILTERS V D E OR SPECIFICATIONS INTRODUCTIONS 2.051 52.1 0.13 (2X) 3.3 (2X) L N G 1.575 0.005 40.0 0.13 1.99MAX. 50.5MAX. 45 50 50 40 40 45 1.18 0.02 30.0 0.5 +0.02 0.85-0 +0.5 21.6-0 1.575 0.005 40.0 0.13 1.12MAX. 28.4MAX. M3 +0.02 1.12-0 +0.5 28.45-0 L Cy SUGGESTED MOUNTING CUTOUT 4.0MIN. 100.0MIN. N WIRE LENGTH : 4.0" MIN. W3EA 1.99MAX. 50.5MAX. N' 0.13(2X) 3.3(2X) G' G 1.575 0.02 40.01 0.5 L R: 1M /-R ONLY 0.87 0.02 22.2 0.5 Lg N G MECHANICAL CONSTRUCTION 1.12MAX. 28.4MAX. +0.02 0.85-0 +0.5 21.6-0 1.575 0.005 40.0 0.13 2.16 0.04 55.5 1.0 1.79 45.5 2.34 59.5 1.18 0.02 30.0 0.5 G3EA +0 R3.0-3.0 +0 R0.12-0.12 21.3MAX. Cx L O A D 21.3MAX. 0.84MAX. N G 22.2 0.5 L 0.87 0.02 1.575 0.02 40.0 0.5 0.13(2X) 3.3(2X) 0.84MAX. R +0.02 0.850-0 G3SA L' Cy R0.118(4X) R3.0(4X) SUGGESTED MOUNTING CUTOUT (MOUNTING FROM FRONT) 30 45 50 50 40 40 45 ELECTRICAL SCHEMATIC L M3(2X) +0.5 21.6-0 2.126 MAX. 54.0 MAX. 1.520 38.6 1.118 MAX. 28.4 MAX. 2.02 0.04 51.5 1.0 COMMON MODE (L-G) IN 50 OHM SYSTEM FREQUENCY-MHz PART NO. .15 .50 1.0 5.0 10 03KEEG3EA/03KEEW3EA 15 20 25 40 40 08KEEG3EA/08KEEW3EA 10 15 20 35 40 10KEEG3EA/10KEEW3EA 7 12 18 30 30 03KEEG3SA/03KEEW3SA 15 20 25 40 40 06KEEG3SA/06KEEW3SA 7 15 20 35 40 10KEEG3SA/10KEEW3SA 4 12 18 30 30 DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM 03KEEG3EA/03KEEW3EA 5 12 15 40 50 08KEEG3EA/08KEEW3EA 5 10 15 45 40 10KEEG3EA/10KEEW3EA 4 12 18 30 30 03KEEG3SA/03KEEW3SA 10 20 35 40 45 06KEEG3SA/06KEEW3SA 10 25 40 35 40 10KEEG3SA/10KEEW3SA 10 25 35 30 30 1.970 MAX. 50.0 MAX. +0.02 1.12-0 +0.5 28.45-0 MINIMUM INSERTION LOSS IN dB L I N E 21.3 MAX. 100 0.839 MAX. 2200 1.575 0.020 40.0 0.5 1.87 0.04 47.5 1.0 03KEEG3EA/03KEEW3EA 3.1 0.8 * 08KEEG3EA/08KEEW3EA 0.4 0.1 ** 10KEEG3EA/10KEEW3EA 03KEEG3SA/03KEEW3SA 3.1 06KEEG3SA/06KEEW3SA 0.8 10KEEG3SA/10KEEW3SA 0.4 * VDE approved to 6A 250V. ** UL, CSA & VDE approved to 9A 115/250VAC. IEC INLET FILTERS 1. Specially designed with ground choke providing most effective 1. Maximum leakage current each EMI suppression for high frequency noise (ranged 5MHz-25MHz). line-to-ground @ 115VAC 60Hz: 0.20mA 2. Bleeder resistor can be added with suffix "-R" on part numbers. @ 250VAC 50Hz: 0.40mA 3. With optional Y capacitor 100pF to 3300pF. 4. All part numbers are UL recognized, CSA certified and VDE approved. 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC COMPONENTS 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC PART NO. L (mH) Cx (uF) Cy (pF) Lg (uH) M3 +0.02 1.12-0 +0.5 28.45-0 +0 R3.0-3.0 +0 R0.12-0.12 SUGGESTED MOUNTING CUTOUT W3EA G3EA 2-11 UNIT: INCH mm