10KEEG3SA

HIGH PERFORMANCE IEC
SERIES CONNECTOR FILTERS
V
D E
OR
SPECIFICATIONS
INTRODUCTIONS
2.051
52.1
0.13 (2X)
3.3 (2X)
L
N
G
1.575 0.005
40.0 0.13
1.99MAX.
50.5MAX.
45
50
50
40
40
45
1.18 0.02
30.0 0.5
+0.02
0.85-0
+0.5
21.6-0
1.575 0.005
40.0 0.13
1.12MAX.
28.4MAX.
M3
+0.02
1.12-0
+0.5
28.45-0
L
Cy
SUGGESTED MOUNTING CUTOUT
4.0MIN.
100.0MIN.
N
WIRE LENGTH : 4.0" MIN.
W3EA
1.99MAX.
50.5MAX.
N'
0.13(2X)
3.3(2X)
G'
G
1.575 0.02
40.01 0.5
L
R: 1M /-R ONLY
0.87 0.02
22.2 0.5
Lg
N
G
MECHANICAL CONSTRUCTION
1.12MAX.
28.4MAX.
+0.02
0.85-0
+0.5
21.6-0
1.575 0.005
40.0 0.13
2.16 0.04
55.5 1.0
1.79
45.5
2.34
59.5
1.18 0.02
30.0 0.5
G3EA
+0
R3.0-3.0
+0
R0.12-0.12
21.3MAX.
Cx
L
O
A
D
21.3MAX.
0.84MAX.
N
G
22.2 0.5
L
0.87 0.02
1.575 0.02
40.0 0.5
0.13(2X)
3.3(2X)
0.84MAX.
R
+0.02
0.850-0
G3SA
L'
Cy
R0.118(4X)
R3.0(4X)
SUGGESTED MOUNTING CUTOUT
(MOUNTING FROM FRONT)
30
45
50
50
40
40
45
ELECTRICAL SCHEMATIC
L
M3(2X)
+0.5
21.6-0
2.126 MAX.
54.0 MAX.
1.520
38.6
1.118 MAX.
28.4 MAX.
2.02 0.04
51.5 1.0
COMMON MODE (L-G) IN 50 OHM SYSTEM
FREQUENCY-MHz
PART NO.
.15
.50
1.0
5.0
10
03KEEG3EA/03KEEW3EA
15
20
25
40
40
08KEEG3EA/08KEEW3EA
10
15
20
35
40
10KEEG3EA/10KEEW3EA
7
12
18
30
30
03KEEG3SA/03KEEW3SA
15
20
25
40
40
06KEEG3SA/06KEEW3SA
7
15
20
35
40
10KEEG3SA/10KEEW3SA
4
12
18
30
30
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
03KEEG3EA/03KEEW3EA
5
12
15
40
50
08KEEG3EA/08KEEW3EA
5
10
15
45
40
10KEEG3EA/10KEEW3EA
4
12
18
30
30
03KEEG3SA/03KEEW3SA
10
20
35
40
45
06KEEG3SA/06KEEW3SA
10
25
40
35
40
10KEEG3SA/10KEEW3SA
10
25
35
30
30
1.970 MAX.
50.0 MAX.
+0.02
1.12-0
+0.5
28.45-0
MINIMUM INSERTION LOSS IN dB
L
I
N
E
21.3 MAX.
100
0.839 MAX.
2200
1.575 0.020
40.0 0.5
1.87 0.04
47.5 1.0
03KEEG3EA/03KEEW3EA
3.1
0.8
* 08KEEG3EA/08KEEW3EA
0.4
0.1
** 10KEEG3EA/10KEEW3EA
03KEEG3SA/03KEEW3SA
3.1
06KEEG3SA/06KEEW3SA
0.8
10KEEG3SA/10KEEW3SA
0.4
* VDE approved to 6A 250V.
** UL, CSA & VDE approved to 9A 115/250VAC.
IEC INLET FILTERS
1. Specially designed with ground choke providing most effective
1. Maximum leakage current each
EMI suppression for high frequency noise (ranged 5MHz-25MHz).
line-to-ground @ 115VAC 60Hz: 0.20mA
2. Bleeder resistor can be added with suffix "-R" on part numbers.
@ 250VAC 50Hz: 0.40mA
3. With optional Y capacitor 100pF to 3300pF.
4. All part numbers are UL recognized, CSA certified and VDE approved. 2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
COMPONENTS
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
PART NO.
L (mH) Cx (uF) Cy (pF) Lg (uH)
M3
+0.02
1.12-0
+0.5
28.45-0
+0
R3.0-3.0
+0
R0.12-0.12
SUGGESTED MOUNTING CUTOUT
W3EA
G3EA
2-11
UNIT: INCH
mm