AR Series

V
D E
SERIES POWER ENTRY MODULE EMI FILTERS
INTRODUCTIONS
SPECIFICATIONS
1. AR series is designed as a high performance, two-stage filter for
low impedance load with better noise attenuation than AK series
in low frequency applications such as switching power supplies.
2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock
prevents fuse removal with line plug inserted (Use only with 250V
fuse).
3. All part numbers are UL recognized, CSA certified and VDE
approved.
4. Switch electrical lifetime: 10,000 cycles.
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
Maximum inrush current: 50A.
COMPONENTS
PART NO.
03AR1/2/3
03AR2D/3D
06AR1/2/3
06AR2D/3D
06AR4
MINIMUM INSERTION LOSS IN dB
C1 (uF) L1 (mH) L2 (mH) Cy (pF)
0.1
1.5
9
2200
0.033
9
1.5
0.1
0.7
2.5
0.015
2.5
0.7
3300
0.1
0.7
2.5
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
.15
.50
1.0
5.0
10
03AR
40
60
60
45
40
06AR
34
55
56
40
35
06AR2D,3D
34
60
60
45
40
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
03AR
6
45
55
50
45
06AR
5
25
60
50
45
06AR2D,3D
10
10
50
50
45
R( )
1M
2.2M
30
30
25
30
40
35
40
ELECTRICAL SCHEMATIC
AR3/4 ONLY
AR3D ONLY
L'
L
L
F
SW1
Cy
C1
R C2
C3
I
L'
L
L
L
F
SW1
O
L1
E
N
G
A
E
G'
FIG. B
C3:0.1uF
TYPE & RATED CURRENT
DELTA PART NO.
115VAC
RATED CURRENT
250VAC
IEC CONNECTOR
FUSE HOLDER
POWER SWITCH
VOLTAGE SELECTOR SW
ELECTRICAL SCHEMATIC
AR1
6A
6A
FIG. A
C3
L2
Cy
N
G
FIG. A
C2:0.1uF
R C2
AR2
6A
6A
AR2D
6A
4A
AR3
6A
6A
AR3D
6A
4A
AR4
6A
6A
SP1
DP2
FIG. A
FIG. B
SP1
REAR3
FIG. A
DP2
REAR3
FIG. B
REAR3
FIG. A
1. Single-pole UL, CSA & VDE approved, VDE-6A at 250VAC.
2. Double-pole UL, CSA & VDE approved, VDE-4A at 250VAC.
Electrical lifetime: 10,000 cycles.
Maximum inrush current: 50A.
3. Voltage selector SW -UL, CSA & VDE approved
Current rating: 10A at 125VAC; 5A at 250VAC.
4-3
L
O
L1
N
N' D
Cy
C1
I
L2
N
Cy
A
N' D
G'
POWER ENTRY MODULE FILTERS
AR1/4 WITHOUT POWER SW
Suggested thickness of mounting
panel is from 0.04 to 0.07 inch
suggest mounting cutout
27.0
1.063 0.003
R0.04Max.
1.0
2.6 0.003
66.0
2.65
67.3
O
G
N
I
L
2.17
55.1
2.38
60.5
1.15
29.2
MECHANICAL CONSTRUCTION
2.57
65.3
1.059
26.9
N
G
L
AR2, AR2D
O
G
N
I
L
AR3, AR3D
AR4(without power switch)
0.65
16.5
115V
G
1.059
26.9
29.2
1.15
2.65
67.3
G
N
L
2.17
55.1
2.24
56.9
POWER ENTRY MODULE FILTERS
2.60
66.0
1.15
29.2
2.65
67.3
G
AR1
2.57
65.3
4-4
1.059
26.9
UNIT: INCH
mm