Download Data Sheet

PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
Rev D
Open Frame (Suffix “O”)
U-Chassis (Suffix “U”)
Enclosed Case (Suffix “C”)
Size: 4.00 x 2.00 x 1.16 inches
Size: 4.60 x 2.44 x 1.54 inches
Size: 4.60 x 2.44 x 1.54 inches
Enclosed w/ External Fan (Suffix “F”)
Din Rail (Suffix “D”)
Din Rail with External Fan (Suffix “DF”)
Size: 4.60 x 2.44 x 1.94 inches
Size: 4.60in x 2.44in x 1.54in
Size: 4.60in x 2.44in x 1.54in
FEATURES
•
•
•
•
•
•
•
Protection Type Class I or Class II
Active Power Factor Correction
2 x 4 Inch Footprint
High Efficiency up to 92%
Adjustable Output Voltage
Built-in EMI Filter
5000M Operating Altitude
•
•
•
•
•
•
Low Leakage Current under 100µF
Low Standby Power Consumption under 0.3W
-25°C to +80°C Operating Temperature Range
Up to 150W with 10CFM Forced Air
4000VAC Input to Output 2 MOPP Insulation
Over Voltage, Over Load, and Short Circuit
Protection
• Designed to Meet Energy Efficiency Level VI
•
•
•
•
85~264 VAC (120~370 VDC) Input Voltage Range
Compliant to RoHS EU Directive 2011/65/EU
CE Marked
ANSI/AAMI ES60601-1, EN60601-1, and
IEC60601-1 3rd Edition Medical Approvals
• Open Frame, U-Chassis, Enclosed Case,
Enclosed Case with External Fan, DIN Rail and
DIN Rail with External Fan Mechanical Options
DESCRIPTION
The PSMAF150 series of AC/DC medical power supplies provides up to 150 Watts of output power with 10CFM forced air and up to 110
Watts with convection cooling in a compact 2 x 4 inch footprint. These supplies feature a universal 85-264VAC (120~370 VDC) input,
enabling them to be used anywhere in the world. The off load power draw is less than 0.3 Watts, which complies with many energy-saving
initiatives. 12V, 15V, 24V, 28V, 36V, and 48VDC single output voltages are available for this series, all of which have a ±10% adjustment
range. These supplies also feature a low leakage current of less than 100μA at 264VAC and are designed to withstand 4000VAC, input to
output. The PSMAF150 series has an operating temperature range of -25°C to +80°C, power factor correction, and a high efficiency up to
92%. These supplies are also protected against short circuit, over voltage, and over current conditions. The PSMAF150 series has
ANSI/AAMI ES60601-1, EN60601-1, and IEC60601-1 3rd edition medical approvals, are CE Marked, are designed to meet Efficiency Level
VI and meet the conducted and radiated EMI requirements of EN55011, EN55022 and FCC Part 18. Open frame, U-chassis, enclosed
case, enclosed case with external fan, DIN rail and DIN rail with external fan mechanical options are available. Class I and Class II
protection types are also available.
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 1 of 12
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
Rev D
MODEL SELECTION TABLE
Model Number (1)
PSMAF150-12S-O
PSMAF150-15S-O
PSMAF150-24S-O
PSMAF150-28S-O
PSMAF150-36S-O
PSMAF150-48S-O
PSMAF150-12S-U
PSMAF150-15S-U
PSMAF150-24S-U
PSMAF150-28S-U
PSMAF150-36S-U
PSMAF150-48S-U
PSMAF150-12S-C
PSMAF150-15S-C
PSMAF150-24S-C
PSMAF150-28S-C
PSMAF150-36S-C
PSMAF150-48S-C
PSMAF150-12S-F
PSMAF150-15S-F
PSMAF150-24S-F
PSMAF150-28S-F
PSMAF150-36S-F
PSMAF150-48S-F
PSMAF150-12S-D
PSMAF150-15S-D
PSMAF150-24S-D
PSMAF150-28S-D
PSMAF150-36S-D
PSMAF150-48S-D
PSMAF150-12S-DF
PSMAF150-15S-DF
PSMAF150-24S-DF
PSMAF150-28S-DF
PSMAF150-36S-DF
PSMAF150-48S-DF
NOTES
Input
Voltage
85 - 264
VAC
(120 - 370
VDC)
85 - 264
VAC
(120 - 370
VDC)
85 - 264
VAC
(120 - 370
VDC)
85 - 264
VAC
(120 - 370
VDC)
85 - 264
VAC
(120 - 370
VDC)
85 - 264
VAC
(120 - 370
VDC)
Output Current
Output
Voltage 10CFM Forced Air Convection
12 VDC
12.5A
8.34 A
15 VDC
10A
7.34 A
Ripple &
Noise
120mVp-p
150mVp-p
24 VDC
28 VDC
36 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
36 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
36 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
36 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
36 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
36 VDC
48 VDC
220mVp-p
220mVp-p
250mVp-p
250mVp-p
120mVp-p
150mVp-p
220mVp-p
220mVp-p
250mVp-p
250mVp-p
120mVp-p
150mVp-p
220mVp-p
220mVp-p
250mVp-p
250mVp-p
120mVp-p
150mVp-p
220mVp-p
220mVp-p
250mVp-p
250mVp-p
120mVp-p
150mVp-p
220mVp-p
220mVp-p
250mVp-p
250mVp-p
120mVp-p
150mVp-p
220mVp-p
220mVp-p
250mVp-p
250mVp-p
6.25A
5.36A
4.17A
3.13A
12.5A
10A
6.25A
5.36A
4.17A
3.13A
12.5A
10A
6.25A
5.36A
4.17A
3.13A
12.5A
10A
6.25A
5.36A
4.17A
3.13A
12.5A
10A
6.25A
5.36A
4.17A
3.13A
12.5A
10A
6.25A
5.36A
4.17A
3.13A
4.59 A
3.93 A
3.06 A
2.09 A
8.34 A
7.34 A
4.59 A
3.93 A
3.06 A
2.09 A
10.84 A
9A
5.63 A
4.83 A
3.75 A
2.71 A
10.84 A
9A
5.63 A
4.83 A
3.75 A
2.71 A
10.84 A
9A
5.63 A
4.83 A
3.75 A
2.71 A
10.84 A
9A
5.63 A
4.83 A
3.75 A
2.71 A
Output Power
10CFM Forced Air Convection
150W
100W
150W
110W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
110W
110W
110W
100W
100W
110W
110W
110W
110W
100W
100W
110W
110W
110W
110W
100W
100W
110W
110W
110W
110W
100W
100W
110W
110W
110W
110W
100W
100W
110W
110W
110W
110W
100W
Efficiency
91%
92%
92%
92%
92%
92%
91%
92%
92%
92%
92%
92%
91%
92%
92%
92%
92%
92%
91%
92%
92%
92%
92%
92%
91%
92%
92%
92%
92%
92%
91%
92%
92%
92%
92%
92%
1. The “X” in the model number represents the package type. It can be “O” for open frame, “U” for U-chassis, “C” for enclosed case, “F” for
enclosed case with external fan, “D” for DIN rail or “DF” for DIN rail with external fan. DIN rail is only available for enclosed case type
models.
2. Class I and Class II protection types are also available for this series. Class I comes standard and for Class II add the suffix “B” to the
model number.
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 12
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
Rev D
SPECIFICATIONS: PSMAF150 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
264
370
63
1.7
0.8
VAC
VDC
Hz
INPUT SPECIFICATIONS
Operating Input Voltage Range
Input Frequency
Input Current
No load Input Power
Power Factor
Input Inrush Current
Input Protection
AC input
DC input
AC input
115VAC and full load
230VAC and full load
230VAC
230VAC
85
120
47
Option -F (With Fan)
Others
0.6
0.3
A
W
0.95
230VAC
Internal fuse in line and neutral
60
T3.15A / 250VAC
A
OUTPUT SPECIFICATIONS
Output Voltage
Initial Set Voltage Accuracy
Line Regulation
Load Regulation
230VAC and full load
Low line to high line at full load
No load to full load
10% load to 90% load
See Table
+1.0
+0.2
+0.5
+0.4
+10
150
110
100
See Table
-1.0
-0.2
-0.5
-0.4
-10
Voltage Adjustability
10CFM forced air cooling (-F)
Convection cooling for 15V, 24V, 28V, and 36V output models
Convection cooling for 12V and 48V output models
Output Power
Output Current
Minimum Load
Ripple & Noise (20MHz BW)
With 1µF/25V 1206 X7R MLCC capacitor
With 1µF/25V 1206 X7R MLCC capacitor
With 1µF/50V 1206 X7R MLCC capacitor
With 1µF/50V 1206 X7R MLCC capacitor
With 1µF/50V 1206 X7R MLCC capacitor
With 0.1µF/100V 1206 X7R MLCC capacitor
Transient Response
Load step from 50~75% change at 2.5A/µs
Start-Up Time
Rise Time
Hold-up Time
Temperature Coefficient
Fan Power Supply
0
120
150
220
220
250
250
12V output model
15V output model
24V output model
28V output model
36V output model
48V output model
Peak Deviation
Recovery Time
%
W
mVp-p
3
500
1000
16
-0.02
%
%
20
115VAC and full load
%
%
+0.02
12V at 500mA
% Vout
µs
ms
ms
ms
%/°C
PROTECTION
Over Voltage Protection
Over Load Protection
Short Circuit Protection
% of Vout (nom); latch mode
% of Iout rated; hiccup mode
115
115
130
%
150
%
Continuous, automatic recovery
GENERAL SPECIFICATIONS
Switching Frequency
60
Isolation Voltage
1 minute (2MOPP insulation)
Isolation Resistance
Leakage Current
500VDC
264VAC
01/05/2016
Input to Output
Input to FG
Output to FG
kHz
4000
1500
1500
0.1
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
VAC
100
GΩ
µA
Page 3 of 12
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
Rev D
SPECIFICATIONS: PSMAF150 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
ENVIRONMENTAL SPECIFICATIONS
Operating Ambient Temperature
Storage Temperature Range
Operating Altitude
Shock
Thermal Shock
Vibration
Relative Humidity
MTBF
10CFM forced air cooled: 150W (with derating)
Convection cooled: 100~110W (with derating)
10CFM forced air cooled: 150W (with derating)
Convection cooled: 100~110W (with derating)
-25
-25
-40
-40
Non-condensing
MIL-HDBK-217F, Ta=25°C, full load
5
786,100
+80
+85
+75
+85
5000 meters
IEC68-2-27
MIL-STD-810F
IEC68-2-6
95
°C
°C
% RH
hours
PHYSICAL SPECIFICATIONS
Open Frame Models (Suffix “-O”)
U-Chassis Models (Suffix “-U”)
Enclosed Case Models (Suffix “-C”, “-D”)
Enclosed Case with External Fan Models (Suffix “-F”, “-DF”)
Weight
Dimensions (L x W x H)
Input Connector (CON1)
Output Connector (CON2)
Fan Connector (CON3)
6.60oz (187g)
8.29oz (235g)
9.03oz (256g)
9.03oz (256g)
4.00 x 2.00 x 1.16 inches
Open Frame Models (Suffix “-O”)
(101.6 x 50.8 x 29.5 mm)
4.60 x 2.44 x 1.54 inches
U-Chassis Models (Suffix “-U”)
(116.8 x 62.0 x 39.2 mm)
4.60 x 2.44 x 1.54 inches
Enclosed Case Models (Suffix “-C”, “-D”)
(116.8 x 62.0 x 39.2 mm)
4.60 x 2.44 x 1.94 inches
Enclosed Case with External Fan Models (Suffix “-F”, “-DF”)
(116.8 x 62.0 x 49.2 mm)
Mates with JST housing VHR-3N and JST Series SVH-21T-P1.1 crimp terminals
Mates with JST housing VHR-6N and JST Series SVH-21T-P1.1 crimp terminals
Mates with Molex housing 22-01-1022 and 2759 crimp terminals
SAFETY & EMC
Safety Approvals
EMI
Conducted
Radiated
Harmonic Currents
Voltage Flicker
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Power Frequency Magnetic Field
Dip and Interruptions
01/05/2016
ANSI/AAMI ES60601-1, IEC60601-1, EN60601-1
Conducted
Class B
Radiated
Class A
Class A and D
EN55011, EN 55022 and FCC Part 18
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Full load
Air±8kV and Contact ±6kV
10 V/m
±2kV
DM ±1kV and CM ±2kV
20 Vrms
10 A/m
30%
60%
230VAC 50Hz
>95%
>95%
30%
60%
100VAC 50Hz
>95%
>95%
500mS
100mS
10mS
5000mS
500mS
100mS
10mS
5000mS
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
Page 4 of 12
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
Rev D
DERATING CURVES
Derating Curve vs Ambient Temperature
Vin=115VAC
Derating Curve vs. Ambient Temperature
Vin=230VAC
Derating Curve vs. Input Voltage
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 5 of 12
Rev D
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
EFFICIENCY CURVES
Efficiency vs. Output Load
MAF150-24S-x
Efficiency vs. Input Voltage
MAF150-24S-x
MECHANICAL DRAWING
OPEN FRAME (SUFFIX “-O”)
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 6 of 12
Rev D
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
MECHANICAL DRAWING
U-CHASSIS (SUFFIX “-U”)
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 7 of 12
Rev D
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
MECHANICAL DRAWING
ENCLOSED CASE (SUFFIX “-C”)
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 8 of 12
Rev D
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
MECHANICAL DRAWING
ENCLOSED CASE WITH EXTERNAL FAN (SUFFIX “-F”)
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 9 of 12
Rev D
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
MECHANICAL DRAWING
DIN RAIL (SUFFIX “-D”)
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 10 of 12
Rev D
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
MECHANICAL DRAWING
DIN RAIL WITH EXTERNAL FAN(SUFFIX “-DF”)
01/05/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 11 of 12
PSMAF150 SERIES
Up to 150 Watts
Medical AC/DC Power Supplies
Single Outputs
Rev D
MODEL NUMBER SETUP
PSMAF
Series Name
150
-
12
S
Output Power
Ouptut Voltage
Output Quantity
150: 150 Watts
12: 12 VDC
S: Single Output
-
O
B
Package Type
Protection
Type
O: Open Frame
15: 15 VDC
U: U-Chassis
24: 24 VDC
C: Enclosed Case
28: 28 VDC
F: Enclosed with External Fan
36: 36 VDC
D: DIN Rail (1)
48: 48 VDC
None: Class I
B: Class II
DF: Din Rail with External Fan
(1) DIN Rail is only available for enclosed case models
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and
development engineers will provide a solution that exceeds your performance requirements on-time and on
budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, welldocumented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for
working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements.
We will continue to provide ongoing support for your project above and beyond the design and production phases.
Give us a call today to discuss your future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
01/05/2016
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
5 Watson Brook Rd.
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 12 of 12