95595

REVISIONS
LTR
DESCRIPTION
DATE (YR-MO-DA)
APPROVED
F
Added device type 11. Added vendor CAGE code 0EU86 for device
types 05 through 09. -sld
99-09-07
Raymond Monnin
G
Add note to paragraph 1.2.2 and table I, conditions. Add case
outline 9.
00-04-06
Raymond Monnin
H
Correct figure 1, case outline M diagram, adding dimension "c", lead
thickness. Change figure 1, case outline M, A2 maximum dimension
from 0.015" to 0.025" and clarify A2 dimension in note 3.
00-06-14
Raymond Monnin
J
Figure 1, case outline 9; changed the min limit for dimensions D2/E2
from 0.990 inches to 0.980 inches. Added vendor cage 88379 for the
case outline 9. Updated paragraph 1.2.3 to describe the five class
levels. -sld
01-05-06
Raymond Monnin
K
Added device types 12 through 18. -sld
01-11-14
Raymond Monnin
L
Added case outline A -sld
03-02-21
Raymond Monnin
M
Added case outline B. Added note to paragraph 1.2.4. -sld.
03-09-22
Raymond Monnin
N
Re-inserted case outline 9 drawing to figure 1. -sld.
04-01-07
Raymond Monnin
REV
SHEET
REV
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
SHEET
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
REV STATUS
REV
N
N
N
N
N
N
N
N
N
N
N
N
N
N
OF SHEETS
SHEET
1
2
3
4
5
6
7
8
9
10
11
12
13
14
PMIC N/A
PREPARED BY
Steve L. Duncan
STANDARD
MICROCIRCUIT
DRAWING
THIS DRAWING IS
AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216
CHECKED BY
Michael C. Jones
APPROVED BY
Kendall A. Cottongim
http://www.dscc.dla.mil
MICROCIRCUIT, HYBRID, MEMORY,
DIGITAL, STATIC RANDOM ACCESS
MEMORY, CMOS, 128K x 32-BIT
DRAWING APPROVAL DATE
95-07-19
REVISION LEVEL
N
SIZE
A
CAGE CODE
5962-95595
67268
SHEET
DSCC FORM 2233
APR 97
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
1 OF
29
5962-E101-04
1. SCOPE
1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A
choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When
available, a choice of radiation hardness assurance levels are reflected in the PIN.
1.2 PIN. The PIN shall be as shown in the following example:
5962



Federal
stock class
designator
\



RHA
designator
(see 1.2.1)
01



Device
type
(see 1.2.2)
95595
/
H



Device
class
designator
(see 1.2.3)
A



Case
outline
(see 1.2.4)
X



Lead
finish
(see 1.2.5)
\/
Drawing number
1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA
levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) shall identify the circuit function as follows:
Device type 1/
01
02
03
04
05,12
06,13
07,14
08,15
09,16
10,17
11,18
Generic number
128K32-120
128K32-100
128K32-85
128K32-70
128K32-55
128K32-45
128K32-35
128K32-25
128K32-20
128K32-17
128K32-15
Circuit function
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
SRAM, 128K x 32-BIT
Access time
120 ns
100 ns
85 ns
70 ns
55 ns
45 ns
35 ns
25 ns
20 ns
17 ns
15 ns
1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level.
All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K,
and E) or QML Listing (Class G and D). The product assurance levels are as follows:
Device class
1/
Device performance documentation
K
Highest reliability class available. This level is intended for use in space
applications.
H
Standard military quality class level. This level is intended for use in applications
where non-space high reliability devices are required.
G
Reduced testing version of the standard military quality class. This level uses the
Class H screening and In-Process Inspections with a possible limited temperature
range, manufacturer specified incoming flow, and the manufacturer guarantees (but
may not test) periodic and conformance inspections (Group A, B, C and D).
Due to the nature of the 4 transistor design of the die used in these device types, topologically pure testing is
important, particularly for high reliability applications. The device manufacturer should be consulted concerning
their testing methods and algorithms.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
2
E
Designates devices which are based upon one of the other classes (K, H, or G)
with exception(s) taken to the requirements of that class. These exception(s) must
be specified in the device acquisition document; therefore the acquisition document
should be reviewed to ensure that the exception(s) taken will not adversely affect
system performance.
Manufacturer specified quality class. Quality level is defined by the manufacturers
internal, QML certified flow. This product may have a limited temperature range.
D
1.2.4 Case outline(s). The case outline(s) shall be as designated in MIL-STD-1835 and as follows:
Outline letter
Descriptive designator
Terminals
A
B
M 1/ 2/
N
See figure 1
See figure 1
See figure 1
See figure 1
68
68
68
68
X
Y
Z
9 2/
See figure 1
See figure 1
See figure 1
See figure 1
68
68
68
68
Package style
Co-fired ceramic, single cavity, quad flat pack
Ceramic, quad flatpack
Ceramic, quad flatpack, single/dual cavity
Co-fired ceramic, single cavity, ultra
low profile, quad flat pack
Ceramic, quad flatpack
Ceramic, quad flatpack, low profile
Ceramic, quad flatpack, dual cavity
Ceramic, quad flatpack
1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534.
1.3 Absolute maximum ratings. 3/
Supply voltage range (VCC) ..........................................................
Signal voltage range (any pin) ......................................................
Power dissipation (PD):
Device types 01 through 08, and 12 through 15........................
Device types 09, 10, 11, 16, 17, and 18 ....................................
Thermal resistance junction-to-case (θJC):
Case outlines X and Y ...............................................................
Case outline M...........................................................................
Case outlines A and N...............................................................
Case outline Z ...........................................................................
Case outlines B and 9 ...............................................................
Storage temperature .....................................................................
Lead temperature (soldering, 10 seconds) ...................................
-0.5 V dc to +7.0 V dc
-0.5 V dc to +7.0 V dc
2.75 W maximum
3.30 W maximum
6.6°C/W
10°C/W
2.72°C/W
8°C/W
4.9°C/W
-65°C to +150°C
+300°C
1.4 Recommended operating conditions.
Supply voltage (VCC) .....................................................................
Input low voltage range (VIL) .........................................................
Input high voltage range (VIH) .......................................................
Output low voltage, maximum (VOL)..............................................
Output high voltage, minimum (VOH).............................................
Case operating temperature range (TC)........................................
1/
2/
3/
+4.5 V dc to +5.5 V dc
-0.3 V dc to +0.8 V dc
+2.2 V dc to VCC +0.5 V dc
+0.4 V dc
+2.4 V dc
-55°C to +125°C
The case outline M is available in either a single or dual cavity package.
Due to the short leads of case outlines M (single cavity) and case outline 9, caution should be taken if the system
application is to be used where extreme thermal transitions can occur. Case outline A can be used if longer leads
are necessary.
Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
3
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a
part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in
the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the
solicitation.
SPECIFICATION
DEPARTMENT OF DEFENSE
MIL-PRF-38534 - Hybrid Microcircuits, General Specification for.
STANDARDS
DEPARTMENT OF DEFENSE
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard Electronic Component Case Outlines.
HANDBOOKS
DEPARTMENT OF DEFENSE
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Unless otherwise indicated, copies of the specification, standards, and handbooks are available from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing shall take precedence. Nothing in this document , however, supercedes applicable laws and regulations unless
a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in
accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as
designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class.
Therefore, the tests and inspections herein may not be performed for the applicable device class (see MIL-PRF-38534).
Furthermore, the manufacturer may take exceptions or use alternate methods to the tests and inspections herein and not
perform them. However, the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device
class.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38534 and herein.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.2.3 Truth table(s). The truth table(s) shall be as specified on figure 3.
3.2.4 Timing diagram(s). The timing diagram(s) shall be as specified on figures 4 and 5.
3.2.5 Block diagram(s). The block diagram(s) shall be as specified on figure 6.
3.2.6 Output load circuit. The output load circuit shall be as specified on figure 7.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
4
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full specified operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are described in table I.
3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked
with the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked as listed in MIL-HDBK103 and QML-38534.
3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described
herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot
sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for
those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer
and be made available to the preparing activity (DSCC-VA) upon request.
3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this
drawing. The certificate of compliance (original copy) submitted to DSCC-VA shall affirm that the manufacturer's product meets
the performance requirements of MIL-PRF-38534 and herein.
3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of
microcircuits delivered to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
5
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
VSS = 0 V dc
+4.5 V dc ≤ VCC ≤ +5.5 V dc
unless otherwise specified
Group A
subgroups
Device
types
Limits
Min
Unit
Max
DC parameters
Supply current 32-bit
mode
ICC32
CS = VIL, OE = VIH,
VCC = +5.5 V dc
f = 5 MHz CMOS compatible
1,2,3
01,02
03,04
05-18
120
120
600
mA
Standby current
ISB
CS = VIH, OE = VIH,
VCC = +5.5 V dc
f = 5 MHz CMOS compatible
1,2,3
01,02
03,04
05-08
12-15
09-11
16-18
2.4
5.0
60
60
80
80
mA
Input leakage current
ILI
VCC = +5.5 V dc,
VIN = GND or VCC
1,2,3
All
10
µA
Output leakage current
ILO
CS = VIH, OE = VIH,
VIN = GND or VCC
1,2,3
All
10
µA
Output low voltage
VOL
VCC = +4.5 V dc,
IOL = 2.1 mA
1,2,3
01-07,
12-14
0.4
08-11,
15-18
0.4
VCC = +4.5 V dc,
IOL = 8 mA
Output high voltage
VOH
1,2,3
VCC = +4.5 V dc,
IOL = -1.0 mA
VCC = +4.5 V dc,
IOL = -4.0 mA
01-07,
12-14
2.4
08-11,
15-18
2.4
2.0
V
V
Data retention characteristics
Data retention supply
voltage
VDR
CS > VCC - 0.2 V dc
1,2,3
All
Data retention current
ICCDR1
VCC = 3 V dc
1,2,3
01-04
5.5
V
1.6
mA
05-11
11.6
12-18
20.0
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
6
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Group A
subgroups
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
VSS = 0 V dc
+4.5 V dc ≤ VCC ≤ +5.5 V dc
unless otherwise specified
Device
types
Limits
Min
Unit
Max
Capacitance
OE capacitance 3/
COE
VIN = 0 V dc, f = 1.0 MHz,
TA = +25°C
4
All
50
pF
WE capacitance 3/
CWE
VOUT = 0 V dc, f = 1.0 MHz,
TA = +25°C,
Case outlines X and Y
4
All
50
pF
20
VOUT = 0 V dc, f = 1.0 MHz,
TA = +25°C,
Case outlines A, B, M, N, Z,
and 9
CS capacitance 3/
CCS
VIN = 0 V dc, f = 1.0 MHz,
TA = +25°C
4
All
20
pF
D0-31 capacitance 3/
CI/O
VOUT = 0 V dc, f = 1.0 MHz,
TA = +25°C
4
All
20
pF
A0-16 capacitance 3/
CAD
VOUT = 0 V dc, f = 1.0 MHz,
TA = +25°C
4
All
50
pF
See 4.3.1c
7,8A,8B
All
See figure 4
9,10,11
01
02
03
04
05,12
06,13
07,14
08,15
09,16
10,17
11,18
Functional tests
Functional tests
Read cycle timing characteristics
Read cycle timing
tRC
ns
120
100
85
70
55
45
35
25
20
17
15
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
7
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Group A
subgroups
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
VSS = 0 V dc
+4.5 V dc ≤ VCC ≤ +5.5 V dc
unless otherwise specified
Device
types
Limits
Min
Unit
Max
Read cycle timing characteristics - Continued.
ns
120
100
85
70
55
45
35
25
20
17
15
Address access timing
tAA
See figure 4
9,10,11
01
02
03
04
05,12
06,13
07,14
08,15
09,16
10,17
11,18
Output hold from address
change
tOH
See figure 4
9,10,11
01-04
05-18
Chip select access timing
tACS
See figure 4
9,10,11
01
02
03
04
05,12
06,13
07,14
08,15
09,16
10,17
11,18
120
100
85
70
55
45
35
25
20
17
15
ns
Output enable to output
valid
tOE
See figure 4
9,10,11
01
02
03
04
05,12
06,13
07,14
08,15
09,16
10,11
17,18
60
50
45
35
30
25
20
15
12
10
10
ns
5
0
ns
See footnote at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
8
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Group A
subgroups
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
VSS = 0 V dc
+4.5 V dc ≤ VCC ≤+5.5 V dc
unless otherwise specified
Device
types
Limits
Min
Unit
Max
Write cycle AC timing characteristics.
Write cycle time
tWC
See figure 5
9,10,11
01
02
03
04
05,12
06,13
07,14
08,15
09,16
10,17
11,18
120
100
85
70
55
45
35
25
20
17
15
ns
Chip select to end of write
tCW
See figure 5
9,10,11
01
02
03
04
05,12
06,13
07,14
08,15
09,16
10,11
17,18
100
80
75
60
45
30
25
20
15
14
14
ns
Address valid to end of
write
tAW
See figure 5
9,10,11
01
02
03
04
05,12
06,13
07,14
08,15
09,10
16,17
11,18
100
80
75
60
45
30
25
20
15
15
14
ns
Data valid to end of write
tDW
See figure 5
9,10,11
01
02
03
04
05,06
12,13
07,14
08,15
09,16
10,11
17,18
50
40
35
30
25
25
20
15
12
10
10
ns
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
9
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Group A
subgroups
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
VSS = 0 V dc
+4.5 V dc ≤ VCC ≤ +5.5 V dc
unless otherwise specified
Device
types
Limits
Min
Unit
Max
Write cycle AC timing characteristics - Continued.
Address setup time
tAS
See figure 5
9,10,11
01-04
05-18
5
0
ns
Write pulse width
tWP
See figure 5
9,10,11
01
02
03
04
05,12
06,13
07,14
08,15
09,16
10,11
17,18
80
70
55
50
45
30
25
20
15
14
14
ns
Address hold time
tAH
See figure 5
9,10,11
01-04
05-18
5
0
ns
Output active from end of
write
tOW
See figure 5
9,10,11
01-04
05-07
12-14
08-11
15-18
5
4
4
3
3
ns
Data hold time
tDH
See figure 5
9,10,11
All
0
ns
1/
Due to the nature of the 4 transistor design of the die used in these device types, topologically pure testing is
important, particularly for high reliability applications. The device manufacturer should be consulted concerning
their testing methods and algorithms.
2/
Unless otherwise specified, the AC test conditions are as follows:
Input pulse levels: VIL = 0 V and VIH = 3.0 V
Input rise and fall times: 5 nanoseconds
Input and output timing reference level: 1.5 V ± 0.5 V
Output loading: see figure 7.
Unless otherwise specified, the DC test conditions are as follows:
VIL = 0.3 V and VIH = VCC - 0.3 V
3/
Parameters shall be tested as part of device characterization and after design and process changes which may affect
these parameters. Parameters shall be guaranteed to the limits specified in table I for all lots not specifically tested.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
10
Case outline A.
FIGURE 1. Case outlines.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
11
Case outline A - Continued.
Symbol
Millimeters
Min
Inches
Max
A
Min
Max
5.10
A1
1.37
b
0.33
B
.200
.054
0.43
.013
0.25 TYP
.017
.010 TYP
c
0.23
0.30
.009
.012
D/E
24.9
25.4
.980
1.000
D1/E1
22.10
22.61
.870
.890
D2/E2
20.32 BSC
.800 BSC
e
1.27 BSC
.050 BSC
L
0.89
R
1.14
.035
0.25 TYP
.045
.010 TYP
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound
units shall rule.
2. Details of pin 1 identifier are optional, but must be located within the zone indicated.
FIGURE 1. Case outlines - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
12
Case outlines M and Z.
FIGURE 1. Case outline(s).
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
13
Case outline M - Continued.
Symbol
A
A1
A2
B
b
c
D/E
D1/E1
D2/E2
D3/E3
e
R
L1
Millimeters
Min
Max
3.12
5.08
2.30
4.72
0.13
0.64
0.25 REF
0.33
0.43
0.15
0.30
20.32 BSC
22.10
22.61
24.89
25.40
23.77
24.28
1.27 BSC
0.13
0.89
1.14
Inches
Min
Max
.123
.200
.118
.186
.005
.025
.010 REF
.013
.017
.006
.012
.800 BSC
.870
.890
.980
1.000
.936
.956
.050 BSC
.005
.035
.045
Case outline Z - Continued.
Symbol
A
A1
A2
B
b
c
D/E
D1/E1
D2/E2
D3/E3
e
R
L1
Millimeters
Min
Max
3.81
5.08
3.76
4.72
0.00
0.51
0.25 REF
0.33
0.43
0.15
0.30
20.32 BSC
22.10
22.61
24.89
25.40
23.77
24.28
1.27 BSC
0.13
0.89
1.14
Inches
Min
Max
.150
.200
.148
.186
.000
.020
.010 REF
.013
.017
.006
.012
.800 BSC
.870
.890
.980
1.000
.936
.956
.050 BSC
.005
.035
.045
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound
units shall rule.
2. Pin numbers are for reference only.
3. Case outline M may either be a single cavity or a dual cavity package. Dimension A2 is measured between the lowest
horizontal plane of the package to the seating plane of the lead(s).
4. Case outline Z is a dual cavity package, only.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
14
Case outline N.
Symbol
A
A2
b
c
D/E
D1/E1
D2/E2
e
L1
R
Millimeters
Min
Max
3.56
0.36
0.71
0.33
0.43
0.23
0.30
20.32 BSC
22.10
22.61
24.89
25.40
1.27 BSC
0.89
1.14
0.13 MIN
Inches
Min
Max
.140
.014
.028
.013
.017
.009
.012
.800 BSC
.870
.890
.980
1.000
.050 TYP
.035
.045
.005 MIN
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units
shall rule.
2. Pin numbers are for reference only.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
15
Case outline X.
Millimeters
Symbol
A
A1
Inches
Min
Max
Min
Max
2.92
5.08
.115
.200
1.52 BSC
A2
1.14
1.39
.060 BSC
.045
.055
b
0.31
0.46
.012
.018
c
0.23
0.31
.009
.012
D/E
63.63
66.42
2.505
2.615
D1/E1
39.24
40.01
1.545
1.575
D2/E2
73.28
84.20
2.885
3.315
e
1.27 BSC
.050 BSC
e1
20.32 BSC
.800 BSC
j
4.83
5.33
.190
.210
k
37.72
38.48
1.485
1.515
S1
9.65 BSC
.380 BSC
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units
shall rule.
2. Pin numbers are for reference only.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
16
Case outline Y.
Millimeters
Symbol
A
A1
Inches
Min
Max
Min
Max
2.92
3.56
.115
.140
1.52 BSC
.060 BSC
A2
1.14
1.39
.045
.055
b
0.31
0.46
.012
.018
c
0.23
0.31
.009
.012
D/E
63.63
66.42
2.505
2.615
D1/E1
39.24
40.01
1.545
1.575
D2/E2
73.28
84.20
2.885
3.315
e
1.27 BSC
e1
.050 BSC
20.32 BSC
.800 BSC
j
4.83
5.33
.190
.210
k
37.72
38.48
1.485
1.515
S1
9.65 BSC
.380 BSC
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units
shall rule.
2. Pin numbers are for reference only
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
17
Case outline B.
Symbol
Millimeters
Min
A
Inches
Max
Min
4.06
A1
Max
.160
2.79
.110
A2
1.12
1.42
.044
.056
b
0.33
0.43
.013
.017
C
0.15
0.25
.006
.010
D/E
20.32 BSC
.800 BSC
D1/E1
23.65
24.10
.931
.949
D2/E2
24.89
25.40
.980
1.000
e
L1
1.27 BSC
0.51
1.14
.050 BSC
.020
.045
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units
shall rule.
2. Pin numbers are for reference only.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
18
Case outline 9.
Millimeters
Symbol
Min
A
Inches
Max
Min
3.56
A1
Max
.140
2.79
.110
A2
0.46
0.76
.018
.030
b
0.33
0.43
.013
.017
C
0.15
0.25
.006
.010
D/E
20.32 BSC
.800 BSC
D1/E1
23.65
24.10
.931
.949
D2/E2
24.89
25.40
.980
1.000
e
L1
1.27 BSC
0.51
1.14
.050 BSC
.020
.045
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units
shall rule.
2. Pin numbers are for reference only.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
19
Device
types
All
Device
types
All
Device
types
All
Device
types
All
Case
outlines
A, B, M,
N, 9
Case
outlines
A, B, M,
N, 9
Case
outlines
A, B, M,
N, 9
Case
outlines
A, B, M,
N, 9
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
1
GND
18
GND
35
OE
52
GND
2
CS 3
19
I/O8
36
CS 2
53
I/O23
3
A5
20
I/O9
37
NC
54
I/O22
4
A4
21
I/O10
38
WE 2
55
I/O21
5
A3
22
I/O11
39
WE 3
56
I/O20
6
A2
23
I/O12
40
WE 4
57
I/O19
7
A1
24
I/O13
41
NC
58
I/O18
8
A0
25
I/O14
42
NC
59
I/O17
9
NC
26
I/O15
43
NC
60
I/O16
10
I/O0
27
VCC
44
I/O31
61
VCC
11
I/O1
28
A11
45
I/O30
62
A10
12
I/O2
29
A12
46
I/O29
63
A9
13
I/O3
30
A13
47
I/O28
64
A8
14
I/O4
31
A14
48
I/O27
65
A7
15
I/O5
32
A15
49
I/O26
66
A6
16
I/O6
33
A16
50
I/O25
67
WE 1
17
I/O7
34
CS 1
51
I/O24
68
CS 4
FIGURE 2. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
20
Device
types
05-10,
12-17
Device
types
05-10,
12-17
Device
types
05-10,
12-17
Device
types
05-10,
12-17
Case
outline
Z
Case
outline
Z
Case
outline
Z
Case
outline
Z
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
1
GND
18
GND
35
OE
52
GND
2
CS 3
19
I/O8
36
CS 2
53
I/O23
3
A5
20
I/O9
37
NC
54
I/O22
4
A4
21
I/O10
38
WE 2
55
I/O21
5
A3
22
I/O11
39
WE 3
56
I/O20
6
A2
23
I/O12
40
WE 4
57
I/O19
7
A1
24
I/O13
41
NC
58
I/O18
8
A0
25
I/O14
42
NC
59
I/O17
9
NC
26
I/O15
43
NC
60
I/O16
10
I/O0
27
VCC
44
I/O31
61
VCC
11
I/O1
28
A11
45
I/O30
62
A10
12
I/O2
29
A12
46
I/O29
63
A9
13
I/O3
30
A13
47
I/O28
64
A8
14
I/O4
31
A14
48
I/O27
65
A7
15
I/O5
32
A15
49
I/O26
66
A6
16
I/O6
33
A16
50
I/O25
67
WE 1
17
I/O7
34
CS 1
51
I/O24
68
CS 4
FIGURE 2. Terminal connections - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
21
Device
types
All
Device
types
All
Device
types
All
Device
types
All
Case
outlines
X,Y
Case
outlines
X,Y
Case
outlines
X,Y
Case
outlines
X,Y
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
Terminal
number
Terminal
symbol
1
GND
18
GND
35
OE
52
GND
2
CS 1
19
I/O8
36
CS 4
53
I/O23
3
A5
20
I/O9
37
NC
54
I/O22
4
A4
21
I/O10
38
NC
55
I/O21
5
A3
22
I/O11
39
NC
56
I/O20
6
A2
23
I/O12
40
NC
57
I/O19
7
A1
24
I/O13
41
NC
58
I/O18
8
A0
25
I/O14
42
NC
59
I/O17
9
NC
26
I/O15
43
NC
60
I/O16
10
I/O0
27
VCC
44
I/O31
61
VCC
11
I/O1
28
A11
45
I/O30
62
A10
12
I/O2
29
A12
46
I/O29
63
A9
13
I/O3
30
A13
47
I/O28
64
A8
14
I/O4
31
A14
48
I/O27
65
A7
15
I/O5
32
A15
49
I/O26
66
A6
16
I/O6
33
A16
50
I/O25
67
WE
17
I/O7
34
CS 2
51
I/O24
68
CS 3
FIGURE 2. Terminal connections - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
22
CS
OE
WE
Mode
Data I/O
Power
H
X
X
Standby
High Z
Standby
L
L
H
Read
Data out
Active
L
H
H
Output
disable
High Z
Active (deselect)
L
X
L
Write
Data in
Active
NOTES:
1. H = VIH = High logic level.
2. L = VIL = Low logic level.
3. X = Do not care (either high or low).
4. High Z = High impedance state.
FIGURE 3. Truth table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
23
FIGURE 4. Read cycle timing diagram.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
24
FIGURE 5. Write cycle timing diagram.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
25
Case outlines A, B, M, N, Z, and 9.
Case outlines X and Y.
FIGURE 6. Block diagram(s) .
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
26
Typical
Unit
Input pulse level
Parameter
0 - 3.0
V
Input rise and fall
5
ns
Input and output reference level
1.5
V
Output load capacitance
50
pF
NOTES:
1. VZ is programmable from -2 V to +7 V.
2. IOL and IOH are programmable from 0 to 16mA.
3. Tester impedance is ZO = 75 ohms.
4. VZ is typically the midpoint of VOH and VOL.
5. IOL and IOH are adjusted to simulate a typical resistive load circuit.
6. ATE tester includes jig capacitance.
FIGURE 7. Output load circuit.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
27
TABLE II. Electrical test requirements.
MIL-PRF-38534 test requirements
Subgroups
(in accordance with
MIL-PRF-38534, group
A test table)
Interim electrical parameters
1,4,7,9
Final electrical parameters
1*,2,3,4,7,8A,8B,9,10,11
Group A test requirements
1,2,3,4,7,8A,8B,9,10,11
Group C end-point electrical
parameters
1,2,3,4,7,8A,8B,9,10,11
Not applicable
End-point electrical parameters for
radiation hardness assurance
(RHA) devices
* PDA applies to subgroup 1.
4. QUALITY ASSURANCE PROVISIONS
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as
modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the
form, fit, or function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply:
a. Burn-in test, method 1015 of MIL-STD-883.
(1)
(2)
Test condition B. The test circuit shall be maintained by the manufacturer under document revision level control
and shall be made available to either DSCC-VA or the acquiring activity upon request. Also, the test circuit
shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent
specified in test method 1015 of MIL-STD-883.
TA as specified in accordance with table I of method 1015 of MIL-STD-883.
b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance
with MIL-PRF-38534 and as specified herein.
4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows:
a.
Tests shall be as specified in table II herein.
b.
Subgroups 5 and 6 shall be omitted.
c.
Subgroups 7 and 8 shall include verification of the truth table on figure 3.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
28
4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534.
4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows:
a.
End-point electrical parameters shall be as specified in table II herein.
b.
Steady-state life test, method 1005 of MIL-STD-883.
(1)
Test condition B. The test circuit shall be maintained by the manufacturer under document revision level control
and shall be made available to either DSCC-VA or the acquiring activity upon request. Also, the test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
test method 1005 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1005 of MIL-STD-883.
(3)
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534.
4.3.5 Radiation Hardness Assurance (RHA) inspection. RHA inspection is not currently applicable to this drawing.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a
contractor-prepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated as specified in MIL-PRF38534.
6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus when a system application
requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be used for
coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962)
should contact DSCC-VA, telephone (614) 692-0544.
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Post Office Box 3990, Columbus, Ohio 432165000, or telephone (614) 692-1081.
6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors listed in MIL-HDBK103 and QML-38534 have submitted a certificate of compliance (see 3.7 herein) to DSCC-VA and have agreed to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-95595
A
REVISION LEVEL
N
SHEET
29
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 04-01-07
Approved sources of supply for SMD 5962-95595 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DSCC-VA. This bulletin is superseded by the next
dated revisions of MIL-HDBK-103 and QML-38534.
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor similar
PIN 2/
5962-9559501HMA
5962-9559501HMC
5962-9559501HNA
5962-9559501HNC
5962-9559501HXC
5962-9559501HYC
5962-9559501H9A
5962-9559501H9C
5962-9559501HBA
5962-9559501HBC
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
WS128K32-120G2Q, WS128K32-120G2UQ
WS128K32-120G2Q, WS128K32-120G2UQ
WS128K32-120G2UQ
WS128K32-120G2UQ
WS128K32-120G4Q
WS128K32-120G4TQ
WS128K32-120G1UQ
WS128K32-120G1UQ
WS128K32-120G1TQ
WS128K32-120G1TQ
5962-9559502HMA
5962-9559502HMC
5962-9559502HNA
5962-9559502HNC
5962-9559502HXC
5962-9559502HYC
5962-9559502H9A
5962-9559502H9C
5962-9559502HBA
5962-9559502HBC
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
WS128K32-100G2Q, WS128K32-100G2UQ
WS128K32-100G2Q, WS128K32-100G2UQ
WS128K32-100G2UQ
WS128K32-100G2UQ
WS128K32-100G4Q
WS128K32-100G4TQ
WS128K32-100G1UQ
WS128K32-100G1UQ
WS128K32-100G1TQ
WS128K32-100G1TQ
5962-9559503HMA
5962-9559503HMC
5962-9559503HNA
5962-9559503HNC
5962-9559503HXC
5962-9559503HYC
5962-9559503H9A
5962-9559503H9C
5962-9559503HBA
5962-9559503HBC
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
WS128K32-85G2Q, WS128K32-85G2UQ
WS128K32-85G2Q, WS128K32-85G2UQ
WS128K32-85G2UQ
WS128K32-85G2UQ
WS128K32-85G4Q
WS128K32-85G4TQ
WS128K32-85G1UQ
WS128K32-85G1UQ
WS128K32-85G1TQ
WS128K32-85G1TQ
5962-9559504HMA
5962-9559504HMC
5962-9559504HNA
5962-9559504HNC
5962-9559504HXC
5962-9559504HYC
5962-9559504H9A
5962-9559504H9C
5962-9559504HBA
5962-9559504HBC
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
WS128K32-70G2Q, WS128K32-70G2UQ
WS128K32-70G2Q, WS128K32-70G2UQ
WS128K32-70G2UQ
WS128K32-70G2UQ
WS128K32-70G4Q
WS128K32-70G4TQ
WS128K32-70G1UQ
WS-128K32-70G1UQ
WS128K32-70G1TQ
WS128K32-70G1TQ
See footnotes at end of table.
1 of 7
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued.
DATE: 04-01-07
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
5962-9559505HAA
5962-9559505HAC
5962-9559505HAA
5962-9559505HAC
5962-9559505HMA
5962-9559505HMC
5962-9559505HMA
5962-9559505HMC
5962-9559505HMA
5962-9559505HMC
5962-9559505HNA
5962-9559505HNC
5962-9559505HNA
5962-9559505HNC
5962-9559505HXC
5962-9559505HXA
5962-9559505HXC
5962-9559505HYC
5962-9559505HYA
5962-9559505HYC
5962-9559505HZA
5962-9559505HZC
5962-9559505H9A
5962-9559505H9C
5962-9559505H9A
5962-9559505H9C
5962-9559505HBA
5962-9559505HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
88379
88379
0EU86
0EU86
54230
54230
54230
88379
88379
54230
88379
88379
88379
88379
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-55/883C
AS8S128K32Q1-55/883C
WS128K32-55G2LQ
WS128K32-55G2LQ
AS8S128K32Q-55/883C
AS8S128K32Q-55/883C
WS128K32-55G2, WS128K32-55G2UQ
WS128K32-55G2, WS128K32-55G2UQ
ACT-S128K32N-055F2Q
ACT-S128K32N-055F2Q
AS8S128K32QT-55/883C
AS8S128K32QT-55/883C
WS128K32-55G2UQ
WS128K32-55G2UQ
WS128K32-55G4Q
ACT-S128K32N-055F1Q
ACT-S128K32N-055F1Q
WS128K32-55G4TQ
ACT-S128K32N-055F1Q
ACT-S128K32N-055F1Q
ACT-S128K32N-055F2Q
ACT-S128K32N-055F2Q
WS128K32-55G1UQ
WS128K32-55G1UQ
ACT-S128K32N-055F18Q
ACT-S128K32N-055F18Q
WS128K32-55G1TQ
WS128K32-55G1TQ
5962-9559506HAA
5962-9559506HAC
5962-9559506HAA
5962-9559506HAC
5962-9559506HMA
5962-9559506HMC
5962-9559506HMA
5962-9559506HMC
5962-9559506HMA
5962-9559506HMC
5962-9559506HNA
5962-9559506HNC
5962-9559506HNA
5962-9559506HNC
5962-9559506HXC
5962-9559506HXA
5962-9559506HXC
5962-9559506HYC
5962-9559506HYA
5962-9559506HYC
5962-9559506HZC
5962-9559506HZA
5962-9559506H9A
5962-9559506H9C
5962-9559506H9A
5962-9559506H9C
5962-9559506HBA
5962-9559506HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
88379
88379
0EU86
0EU86
54230
54230
54230
88379
88379
54230
88379
88379
88379
88379
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-45/883C
AS8S128K32Q1-45/883C
WS128K32-45G2LQ
WS128K32-45G2LQ
AS8S128K32Q-45/883C
AS8S128K32Q-45/883C
WS128K32-45G2Q, WS128K32-45G2UQ
WS128K32-45G2Q, WS128K32-45G2UQ
ACT-S128K32N-045F2Q
ACT-S128K32N-045F2Q
AS8S128K32QT-45/883C
AS8S128K32QT-45/883C
WS128K32-45G2UQ
WS128K32-45G2UQ
WS128K32-45G4Q
ACT-S128K32N-045F1Q
ACT-S128K32N-045F1Q
WS128K32-45G4TQ
ACT-S128K32N-045F1Q
ACT-S128K32N-045F1Q
ACT-S128K32N-045F2Q
ACT-S128K32N-045F2Q
WS128K32-45G1UQ
WS128K32-45G1UQ
ACT-S128K32N-045F18Q
ACT-S128K32N-045F18Q
WS128K32-45G1TQ
WS128K32-45G1TQ
Vendor similar
PIN 2/
See footnotes at end of table.
2 of 7
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued.
DATE: 04-01-07
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor similar
PIN 2/
5962-9559507HAA
5962-9559507HAC
5962-9559507HAA
5962-9559507HAC
5962-9559507HMA
5962-9559507HMC
5962-9559507HMA
5962-9559507HMC
5962-9559507HMA
5962-9559507HMC
5962-9559507HNA
5962-9559507HNC
5962-9559507HNA
5962-9559507HNC
5962-9559507HXC
5962-9559507HXA
5962-9559507HXC
5962-9559507HYC
5962-9559507HYA
5962-9559507HYC
5962-9559507HZA
5962-9559507HZC
5962-9559507H9A
5962-9559507H9C
5962-9559507H9A
5962-9559507H9C
5962-9559507HBA
5962-9559507HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
88379
88379
0EU86
0EU86
54230
54230
54230
88379
88379
54230
88379
88379
88379
88379
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-35/883C
AS8S128K32Q1-35/883C
WS128K32-35G2LQ
WS128K32-35G2LQ
AS8S128K32Q-35/883C
AS8S128K32Q-35/883C
WS128K32-35G2Q, WS128K32-35G2UQ
WS128K32-35G2Q, WS128K32-35G2UQ
ACT-S128K32N-035F2Q
ACT-S128K32N-035F2Q
AS8S128K32QT-35/883C
AS8S128K32QT-35/883C
WS128K32-35G2UQ
WS128K32-35G2UQ
WS128K32-35G4Q
ACT-S128K32N-035F1Q
ACT-S128K32N-035F1Q
WS128K32-35G4TQ
ACT-S128K32N-035F1Q
ACT-S128K32N-035F1Q
ACT-S128K32N-035F2Q
ACT-S128K32N-035F2Q
WS128K32-35G1UQ
WS128K32-35G1UQ
ACT-S128K32N-035F18Q
ACT-S128K32N-035F18Q
WS128K32-35G1TQ
WS128K32-35G1TQ
5962-9559508HAA
5962-9559508HAC
5962-9559508HAA
5962-9559508HAC
5962-9559508HMA
5962-9559508HMC
5962-9559508HMA
5962-9559508HMC
5962-9559508HMA
5962-9559508HMC
5962-9559508HNA
5962-9559508HNC
5962-9559508HNA
5962-9559508HNC
5962-9559508HXC
5962-9559508HXA
5962-9559508HXC
5962-9559508HYC
5962-9559508HYA
5962-9559508HYC
5962-9559508HZA
5962-9559508HZC
5962-9559508H9A
5962-9559508H9C
5962-9559508H9A
5962-9559508H9C
5962-9559508HBA
5962-9559508HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
88379
88379
0EU86
0EU86
54230
54230
54230
88379
88379
54230
88379
88379
88379
88379
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-25/883C
AS8S128K32Q1-25/883C
WS128K32-25G2LQ
WS128K32-25G2LQ
AS8S128K32Q-25/883C
AS8S128K32Q-25/883C
WS128K32-25G2Q, WS128K32-25G2UQ
WS128K32-25G2Q, WS128K32-25G2UQ
ACT-S128K32N-025F2Q
ACT-S128K32N-025F2Q
AS8S128K32QT-25/883C
AS8S128K32QT-25/883C
WS128K32-25G2UQ
WS128K32-25G2UQ
WS128K32-25G4Q
ACT-S128K32N-025F1Q
ACT-S128K32N-025F1Q
WS128K32-25G4TQ
ACT-S128K32N-025F1Q
ACT-S128K32N-025F1Q
ACT-S128K32N-025F2Q
ACT-S128K32N-025F2Q
WS128K32-25G1UQ
WS128K32-25G1UQ
ACT-S128K32N-025F18Q
ACT-S128K32N-025F18Q
WS128K32-25G1TQ
WS128K32-25G1TQ
See footnotes at end of table.
3 of 7
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued.
DATE: 04-01-07
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor similar
PIN 2/
5962-9559509HAA
5962-9559509HAC
5962-9559509HAA
5962-9559509HAC
5962-9559509HMA
5962-9559509HMC
5962-9559509HMA
5962-9559509HMC
5962-9559509HMA
5962-9559509HMC
5962-9559509HNA
5962-9559509HNC
5962-9559509HNA
5962-9559509HNC
5962-9559509HXC
5962-9559509HXA
5962-9559509HXC
5962-9559509HYC
5962-9559509HYA
5962-9559509HYC
5962-9559509HZA
5962-9559509HZC
5962-9559509H9A
5962-9559509H9C
5962-9559509H9A
5962-9559509H9C
5962-9559509HBA
5962-9559509HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
88379
88379
0EU86
0EU86
54230
54230
54230
88379
88379
54230
88379
88379
88379
88379
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-20/883C
AS8S128K32Q1-20/883C
WS128K32-20G2LQ
WS128K32-20G2LQ
AS8S128K32Q-20/883C
AS8S128K32Q-20/883C
WS128K32-20G2Q, WS128K32-20G2UQ
WS128K32-20G2Q, WS128K32-20G2UQ
ACT-S128K32N-020F2Q
ACT-S128K32N-020F2Q
AS8S128K32QT-20/883C
AS8S128K32QT-20/883C
WS128K32-20G2UQ
WS128K32-20G2UQ
WS128K32-20G4Q
ACT-S128K32N-020F1Q
ACT-S128K32N-020F1Q
WS128K32-20G4TQ
ACT-S128K32N-020F1Q
ACT-S128K32N-020F1Q
ACT-S128K32N-020F2Q
ACT-S128K32N-020F2Q
WS128K32-20G1UQ
WS128K32-20G1UQ
ACT-S128K32N-F18Q
ACT-S128K32N-F18Q
WS128K32-20G1TQ
WS128K32-20G1TQ
5962-9559510HAA
5962-9559510HAC
5962-9559510HAA
5962-9559510HAC
5962-9559510HMA
5962-9559510HMC
5962-9559510HMA
5962-9559510HMC
5962-9559510HMA
5962-9559510HMC
5962-9559510HNA
5962-9559510HNC
5962-9559510HNA
5962-9559510HNC
5962-9559510HXC
5962-9559510HXA
5962-9559510HXC
5962-9559510HYC
5962-9559510HYA
5962-9559510HYC
5962-9559510HZC
5962-9559510HZA
5962-9559510H9A
5962-9559510H9C
5962-9559510H9A
5962-9559510H9C
5962-9559510HBA
5962-9559510HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
88379
88379
0EU86
0EU86
54230
54230
54230
88379
88379
54230
88379
88379
88379
88379
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-17/883C
AS8S128K32Q1-17/883C
WS128K32-17G2LQ
WS128K32-17G2LQ
AS8S128K32Q-17/883C
AS8S128K32Q-17/883C
WS128K32-17G2Q, WS128K32-17G2UQ
WS128K32-17G2Q, WS128K32-17G2UQ
ACT-S128K32N-017F2Q
ACT-S128K32N-017F2Q
AS8S128K32QT-17/883C
AS8S128K32QT-17/883C
WS128K32-17G2UQ
WS128K32-17G2UQ
WS128K32-17G4Q
ACT-S128K32N-017F1Q
ACT-S128K32N-017F1Q
WS128K32-17G4TQ
ACT-S128K32N-017F1Q
ACT-S128K32N-017F1Q
ACT-S128K32N-017F2Q
ACT-S128K32N-017F2Q
WS128K32-17G1UQ
WS128K32-17G1UQ
ACT-S128K32N-017F18Q
ACT-S128K32N-017F18Q
WS128K32-17G1TQ
WS128K32-17G1TQ
See footnotes at end of table.
4 of 7
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued.
DATE: 04-01-07
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
5962-9559511HAA
5962-9559511HAC
5962-9559511HMA
5962-9559511HMC
5962-9559511HNA
5962-9559511HNC
5962-9559511HXA
5962-9559511HXC
5962-9559511HYA
5962-9559511HYC
5962-9559511H9A
5962-9559511H9C
5962-9559511HBA
5962-9559511HBC
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
WS128K32-15G2LQ
WS128K32-15G2LQ
WS128K32-15G2Q, WS128K32-15G2UQ
WS128K32-15G2Q, WS128K32-15G2UQ
WS128K32-15G2UQ
WS128K32-15G2UQ
WS128K32-15G4Q
WS128K32-15G4Q
WS128K32-15G4TQ
WS128K32-15G4TQ
WS128K32-15G1UQ
WS128K32-15G1UQ
WS128K32-15G1TQ
WS128K32-15G1TQ
5962-9559512HAA
5962-9559512HAC
5962-9559512HAA
5962-9559512HAC
5962-9559512HMA
5962-9559512HMC
5962-9559512HMA
5962-9559512HMC
5962-9559512HNA
5962-9559512HNC
5962-9559512HNA
5962-9559512HNC
5962-9559512HXC
5962-9559512HYC
5962-9559512H9A
5962-9559512H9C
5962-9559512H9A
5962-9559512H9C
5962-9559512HBA
5962-9559512HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
54230
54230
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-55/883C
AS8S128K32Q1-55/883C
WS128K32H-55G2LQ
WS128K32H-55G2LQ
AS8S128K32Q-55/883C
AS8S128K32Q-55/883C
WS128K32H-55G2, WS128K32H-55G2UQ
WS128K32H-55G2, WS128K32H-55G2UQ
AS8S128K32QT-55/883C
AS8S128K32QT-55/883C
WS128K32H-55G2UQ
WS128K32H-55G2UQ
WS128K32H-55G4Q
WS128K32H-55G4TQ
WS128K32H-G1UQ
WS128K32H-G1UQ
ACT-S128K32N-055F18Q-R
ACT-S128K32N-055F18Q-R
WS128K32H-55G1TQ
WS128K32H-55G1TQ
5962-9559513HAA
5962-9559513HAC
5962-9559513HAA
5962-9559513HAC
5962-9559513HMA
5962-9559513HMC
5962-9559513HMA
5962-9559513HMC
5962-9559513HNA
5962-9559513HNC
5962-9559513HNA
5962-9559513HNC
5962-9559513HXC
5962-9559513HYC
5962-9559513H9A
5962-9559513H9C
5962-9559513H9A
5962-9559513H9C
5962-9559513HBA
5962-9559513HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
54230
54230
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-45/883C
AS8S128K32Q1-45/883C
WS128K32H-45G2LQ
WS128K32H-45G2LQ
AS8S128K32Q-45/883C
AS8S128K32Q-45/883C
WS128K32H-45HG2Q, WS128K32H-45HG2UQ
WS128K32H-45HG2Q, WS128K32H-45HG2UQ
AS8S128K32QT-45/883C
AS8S128K32QT-45/883C
WS128K32H-45G2UQ
WS128K32H-45G2UQ
WS128K32H-45G4Q
WS128K32H-45G4TQ
WS128K32H-45G1UQ
WS128K32H-45G1UQ
ACT-S128K32N-045F18Q-R
ACT-S128K32N-045F18Q-R
WS128K32H-45G1TQ
WS128K32H-45G1TQ
Vendor
similar
PIN 2/
See footnotes at end of table.
5 of 7
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued.
DATE: 04-01-07
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962-9559514HAA
5962-9559514HAC
5962-9559514HAA
5962-9559514HAC
5962-9559514HMA
5962-9559514HMC
5962-9559514HMA
5962-9559514HMC
5962-9559514HNA
5962-9559514HNC
5962-9559514HNA
5962-9559514HNC
5962-9559514HXC
5962-9559514HYC
5962-9559514H9A
5962-9559514H9C
5962-9559514H9A
5962-9559514H9C
5962-9559514HBA
5962-9559514HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
54230
54230
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-35/883C
AS8S128K32Q1-35/883C
WS128K32H-35G2LQ
WS128K32H-35G2LQ
AS8S128K32Q-35/883C
AS8S128K32Q-35/883C
WS128K32H-35G2Q, WS128K32H-35G2UQ
WS128K32H-35G2Q, WS128K32H-35G2UQ
AS8S128K32QT-35/883C
AS8S128K32QT-35/883C
WS128K32H-35G2UQ
WS128K32H-35G2UQ
WS128K32H-35G4Q
WS128K32H-35G4TQ
WS128K32H-35G1UQ
WS128K32H-35G1UQ
ACT-S128K32N-035F18Q-R
ACT-S128K32N-035F18Q-R
WS128K32H-35G1TQ
WS128K32H-35G1TQ
5962-9559515HAA
5962-9559515HAC
5962-9559515HAA
5962-9559515HAC
5962-9559515HMA
5962-9559515HMC
5962-9559515HMA
5962-9559515HMC
5962-9559515HNA
5962-9559515HNC
5962-9559515HNA
5962-9559515HNC
5962-9559515HXC
5962-9559515HYC
5962-9559515H9A
5962-9559515H9C
5962-9559515H9A
5962-9559515H9C
5962-9559515HBA
5962-9559515HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
54230
54230
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-25/883C
AS8S128K32Q1-25/883C
WS128K32H-25G2LQ
WS128K32H-25G2LQ
AS8S128K32Q-25/883C
AS8S128K32Q-25/883C
WS128K32H-25G2Q, WS128K32H-25G2UQ
WS128K32H-25G2Q, WS128K32H-25G2UQ
AS8S128K32QT-25/883C
AS8S128K32QT-25/883C
WS128K32H-25G2UQ
WS128K32H-25G2UQ
WS128K32H-25G4Q
WS128K32H-25G4TQ
WS128K32H-25G1UQ
WS128K32H-25G1UQ
ACT-S128K32N-025F18Q-R
ACT-S128K32N-025F18Q-R
WS128K32H-25G1TQ
WS128K32H-25G1TQ
5962-9559516HAA
5962-9559516HAC
5962-9559516HAA
5962-9559516HAC
5962-9559516HMA
5962-9559516HMC
5962-9559516HMA
5962-9559516HMC
5962-9559516HNA
5962-9559516HNC
5962-9559516HNA
5962-9559516HNC
5962-9559516HXC
5962-9559516HYC
5962-9559516H9A
5962-9559516H9C
5962-9559516H9A
5962-9559516H9C
5962-9559516HBA
5962-9559516HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
54230
54230
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-20/883C
AS8S128K32Q1-20/883C
WS128K32H-20G2LQ
WS128K32H-20G2LQ
AS8S128K32Q-20/883C
AS8S128K32Q-20/883C
WS128K32H-20G2Q, WS128K32H-20G2UQ
WS128K32H-20G2Q, WS128K32H-20G2UQ
AS8S128K32QT-20/883C
AS8S128K32QT-20/883C
WS128K32H-20G2UQ
WS128K32H-20G2UQ
WS128K32H-20G4Q
WS128K32H-20G4TQ
WS128K32H-20G1UQ
WS128K32H-20G1UQ
ACT-S128K32N-020F18Q-R
ACT-S128K32N-020F18Q-R
WS128K32H-20G1TQ
WS128K32H-20G1TQ
See footnotes at end of table.
6 of 7
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued.
DATE: 04-01-07
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
5962-9559517HAA
5962-9559517HAC
5962-9559517HAA
5962-9559517HAC
5962-9559517HMA
5962-9559517HMC
5962-9559517HMA
5962-9559517HMC
5962-9559517HNA
5962-9559517HNC
5962-9559517HNA
5962-9559517HNC
5962-9559517HXC
5962-9559517HYC
5962-9559517H9A
5962-9559517H9C
5962-9559517H9A
5962-9559517H9C
5962-9559517HBA
5962-9559517HBC
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
0EU86
0EU86
54230
54230
54230
54230
54230
54230
88379
88379
54230
54230
AS8S128K32Q1-17/883C
AS8S128K32Q1-17/883C
WS128K32H-17G2LQ
WS128K32H-17G2LQ
AS8S128K32Q-17/883C
AS8S128K32Q-17/883C
WS128K32H-17G2Q, WS128K32H-17G2UQ
WS128K32H-17G2Q, WS128K32H-17G2UQ
AS8S128K32QT-17/883C
AS8S128K32QT-17/883C
WS128K32H-17G2UQ
WS128K32H-17G2UQ
WS128K32H-17G4Q
WS128K32H-17G4TQ
WS128K32H-17G1UQ
WS128K32H-17G1UQ
ACT-S128K32N-017F18Q-R
ACT-S128K32N-017F18Q-R
WS128K32H-17G1TQ
WS128K32H-17G1TQ
5962-9559518HAA
5962-9559518HAC
5962-9559518HMA
5962-9559518HMC
5962-9559518HNA
5962-9559518HNC
5962-9559518HXC
5962-9559518HYC
5962-9559518H9A
5962-9559518H9C
5962-9559518HBA
5962-9559518HBC
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
54230
WS128K32H-15G2LQ
WS128K32H-15G2LQ
WS128K32H-15G2Q, WS128K32H-15G2UQ
WS128K32H-15G2Q, WS128K32H-15G2UQ
WS128K32H-15G2UQ
WS128K32H-15G2UQ
WS128K32H-15G4Q
WS128K32H-15G4TQ
WS128K32H-15G1UQ
WS128K32H-15G1UQ
WS128K32H-15G1TQ
WS128K32H-15G1TQ
Vendor
similar
PIN 2/
1/ The lead finish shown for each PIN, representing a hermetic package, is the most readily available from the
manufacturer listed for that part. If the desired lead finish is not listed contact the Vendor to determine
availability.
2/ Caution. Do not use this number for item acquisition. Items acquired to this number may not satisfy the
performance requirements of this drawing.
Vendor CAGE
number
Vendor name
and address
0EU86
Austin Semiconductor Incorporated
8701 Cross Park Drive
Austin, TX 78754-4566
54230
White Electronic Designs Corporation
3601 East University Drive
Phoenix, AZ 85034
88379
Aeroflex Circuit Technology Corporation
35 South Service Road
Plainview, NY 11803-4193
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in this
information bulletin.
7 of 7