DTCGSW30 SERIES 15~30 Watts AC DC Desktop Power Supplies Single Output Rev B FEATURES • Level VI Compliant • Input Voltage Range of 90~264VAC • Drop In Tested • RoHS Compliant • Over Current and Short Circuit Protection • Burn In Tested • UL, CUL, FCC, CE, GS, KC, PSE, CCC, SAA, C-Tick, and CB Safety Approvals • C8 AC Inlet DESCRIPTION The DTCGSW30 series of AC DC desktop power supplies offers 15~30 watts of continuous output power. This series consists of single output models with an input voltage range of 90~264VAC and output voltages ranging from 5~12V. This series features a C8 AC inlet, Energy Level VI compliance, and models have been both drop in and burn in tested. All models are protected against over current and short circuit conditions, and all have U UL, CUL, FCC, CE, GS, KC, PSE, CCC, SAA, C-Tick, and CB safety approvals. Please call factory for ordering details. Size: 3.46in x 1.97in x 1.81in (91.1mm x 45.4mm x 27.5mm) MODEL SELECTION TABLE Input Voltage Range Model Number Output Voltage Output Current Min. Max. Ripple & Noise(1) Output Power Efficiency Level DTCGSW30-090-2000 9V 0mA 2000mA 90mV Level VI DTCGSW30-090-3000 9V 0mA 3000mA 90mV Level VI DTCGSW30-120-1500 12V 0mA 1500mA 120mV Level VI DTCGSW30-120-2000 12V 0mA 2000mA 120mV DTCGSW30-120-2500 12V 0mA 2500mA 120mV DTCGSW30-180-1000 18V 0mA 1000mA 150mV Level VI DTCGSW30-240-1000 24V 0mA 1000mA 150mV Level VI 1/6/2016 90~264VAC 15~30 Watts Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Level VI Level VI Page 1 of 6 Rev B DTCGSW30 SERIES 15~30 Watts AC DC Desktop Power Supplies Single Output SPECIFICATIONS All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS INPUT SPECIFICATIONS Input Voltage Range Input Frequency Input AC Current Inrush Current Standby Power OUTPUT SPECIFICATIONS Output Voltage Line Regulation Load Regulation Output Power Output Current Minimum Load Ripple & Noise (20MHz bandwidth) Turn-On Delay Time Hold-Up Time Rise Time Fall Time Overshoot/Undershoot Dynamic Response Overshoot PROTECTION Typ Max Unit 90 100~240 264 VAC 47 60/50 63 1.2 40 Hz A A W ≤0.1 No Load See Table +1 +5 See Table See Table -1 -5 0 @100VAC to 240VAC Input & Full Load @Full Load &115VAC/60Hz; Input will turn off at worst case @Full Load &230VAC/50Hz; Input will turn off at worse case @Rated Load @Full Load When the power is on or off All output voltages for load step from 25% to 50% to 25%, 50% to 75% to 50% R/S: 0.25A/uS, Transient Response Min 240 3 10 20 % % A mVp-p S mS 20 mS 20 10 mS % 200 uS 5 % The input power will decrease when the output rail shorts, the power supply Automatic Recovery will not damage and will self-recover when the fault condition is removed The output will hiccup when the over current are applied to the output rail and Over Current Protection Automatic Recovery shall self-recovery when the fault condition is removed. 5V Models <7 7.5V Models <5.5 Over Current Point Limited 100-240VAC 9V (2.5A) Models <5 A 9V (3A) Models <6.5 12V Models <4 ENVIRONMENTAL SPECIFICATIONS Operating Temperature 10 40 ºC Humidity 5 95 %RH Storage Temperature -20 80 ºC Temperature Coefficient 0.05 %/ºC Cooling Convection MTBF @25ºC ambient temperature max. working load, according to MIL-HDBK-217 50,000 Hours GENERAL SPECIFICATIONS Height: 1m; the product should be felled off on the hardwood with the thickness of 20mm, and the hardwood should be put on a cement base on or Drop In the ground without flexibility. Apply two times on all surfaces. Apply two times on all corners. The power supply will be burned-in for 4 hours under normal input and 80% Burn-In rated load at 40ºC±5ºC Primary to Secondary: 3000VAC/ 10mA Max. /60 Seconds Dielectric Strength (Hi-pot) Primary to Secondary: 3300VAC/ 5mA Max. /3S Leakage Current @264VAC/50Hz 0.25 mA Insulation Resistance Primary to Secondary add 500VDC Test Voltage 50 MΩ PHYSICAL SPECIFICATIONS Weight Approx. 5.29oz (150g) 3.46in x 1.97in x 1.81in Dimensions (L x W x H) (91.9mm x 45.4mm x 27.5in) Short Circuit Protection 1/6/2016 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 2 of 6 DTCGSW30 SERIES 15~30 Watts AC DC Desktop Power Supplies Single Output Rev B SPECIFICATIONS All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit SAFETY & EMC CHARACTERISTICS Regulatory Standards Type CE FCC SAA (3) EMI Standards Country Europe USA Australia 5V-9V Models ESD EN61000-4-2 Radiated Electromagnetic Field Susceptibility EN 61000-4-3 Electric Fast Transients (burst) Immunity Requirement EN 61000-4-4 Surge Capability Requirement EN 61000-4-5 Induced Radio Frequency Fields Conducted Disturbances Immunity EN 61000-4-6 Acceptance Criteria A Assessment Criteria B C EN55022 EN61000-3-2 FCC Part15 Standard EN60950-1 UL60950 AS/NZ 60950.1 Class B Discharge Test Level Test Criteria Characteristic Air Discharge ±8KV B Contact Discharge ±4KV B Test Level Test Criteria 3V/m (r.m.s) A 80-1000MHz Coupling Test Level Test Criteria AC-Input 0.5KV A AC-Input 1KV B Surge Voltage Test Criteria Common Mode ±2KV A Differential Mode ±1KV Test Level Test Criteria 3V A 0.15-80 MHz, 80%AM (1KHz) Performance Agreed operational behavior within the specified limits Time limited functional diminishment or malfunction during the tests is permitted. The function is self-reactivated by the unit following completion of the tests. Malfunction is permitted. The function can be reactivated either by reconnection to the mains or by operator intervention. NOTES (1) (2) (3) 1/6/2016 Ripple and Noise is measured by 20MHz bandwidth oscilloscope and the output paralleled a 0.1uF ceramic capacitor and a 10uF electrolysis capacitor. (Test under the condition of rated input and rated output) Efficiency measured Nominal input. Efficiency indicated is minimum. Regulatory standards for 5V-9V Models Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 3 of 6 Rev B DTCGSW30 SERIES 15~30 Watts AC DC Desktop Power Supplies Single Output MECHANICAL DRAWINGS PC + ABS Temperature: 95ºC PC Material compliance with the ball pressure test requirments DC Cord Drawing 1/6/2016 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 4 of 6 Rev B DTCGSW30 SERIES 15~30 Watts AC DC Desktop Power Supplies Single Output Label Drawing Package Drawing Packing Details: 90pcs/carton, 12.5kg/carton, external carton size: 51cm x 39cm x 22cm COMPANY INFORMATION 1/6/2016 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 5 of 6 Rev B DTCGSW30 SERIES 15~30 Watts AC DC Desktop Power Supplies Single Output Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 1/6/2016 (603)778-2300 (888)597-9255 (603)778-9797 [email protected] www.wallindustries.com 37 Industrial Drive Exeter, NH 03833 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 6 of 6