Download Data Sheet

DTCGSW30 SERIES
15~30 Watts
AC DC Desktop Power Supplies
Single Output
Rev B
FEATURES
• Level VI Compliant
• Input Voltage Range of
90~264VAC
• Drop In Tested
• RoHS Compliant
• Over Current and Short Circuit Protection
• Burn In Tested
• UL, CUL, FCC, CE, GS, KC, PSE, CCC,
SAA, C-Tick, and CB Safety Approvals
• C8 AC Inlet
DESCRIPTION
The DTCGSW30 series of AC DC desktop power supplies offers 15~30 watts
of continuous output power. This series consists of single output models with
an input voltage range of 90~264VAC and output voltages ranging from
5~12V. This series features a C8 AC inlet, Energy Level VI compliance, and
models have been both drop in and burn in tested. All models are protected
against over current and short circuit conditions, and all have U UL, CUL,
FCC, CE, GS, KC, PSE, CCC, SAA, C-Tick, and CB safety approvals. Please
call factory for ordering details.
Size: 3.46in x 1.97in x 1.81in (91.1mm x 45.4mm x 27.5mm)
MODEL SELECTION TABLE
Input Voltage
Range
Model Number
Output Voltage
Output Current
Min.
Max.
Ripple & Noise(1)
Output Power
Efficiency Level
DTCGSW30-090-2000
9V
0mA
2000mA
90mV
Level VI
DTCGSW30-090-3000
9V
0mA
3000mA
90mV
Level VI
DTCGSW30-120-1500
12V
0mA
1500mA
120mV
Level VI
DTCGSW30-120-2000
12V
0mA
2000mA
120mV
DTCGSW30-120-2500
12V
0mA
2500mA
120mV
DTCGSW30-180-1000
18V
0mA
1000mA
150mV
Level VI
DTCGSW30-240-1000
24V
0mA
1000mA
150mV
Level VI
1/6/2016
90~264VAC
15~30 Watts
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Level VI
Level VI
Page 1 of 6
Rev B
DTCGSW30 SERIES
15~30 Watts
AC DC Desktop Power Supplies
Single Output
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
INPUT SPECIFICATIONS
Input Voltage Range
Input Frequency
Input AC Current
Inrush Current
Standby Power
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
Load Regulation
Output Power
Output Current
Minimum Load
Ripple & Noise (20MHz bandwidth)
Turn-On Delay Time
Hold-Up Time
Rise Time
Fall Time
Overshoot/Undershoot
Dynamic Response Overshoot
PROTECTION
Typ
Max
Unit
90
100~240
264
VAC
47
60/50
63
1.2
40
Hz
A
A
W
≤0.1
No Load
See Table
+1
+5
See Table
See Table
-1
-5
0
@100VAC to 240VAC Input & Full Load
@Full Load &115VAC/60Hz; Input will turn off at worst case
@Full Load &230VAC/50Hz; Input will turn off at worse case
@Rated Load
@Full Load
When the power is on or off
All output voltages for load step from 25% to 50% to 25%, 50% to 75% to
50% R/S: 0.25A/uS,
Transient Response
Min
240
3
10
20
%
%
A
mVp-p
S
mS
20
mS
20
10
mS
%
200
uS
5
%
The input power will decrease when the output rail shorts, the power supply
Automatic Recovery
will not damage and will self-recover when the fault condition is removed
The output will hiccup when the over current are applied to the output rail and
Over Current Protection
Automatic Recovery
shall self-recovery when the fault condition is removed.
5V Models
<7
7.5V Models
<5.5
Over Current Point Limited
100-240VAC
9V (2.5A) Models
<5
A
9V (3A) Models
<6.5
12V Models
<4
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
10
40
ºC
Humidity
5
95
%RH
Storage Temperature
-20
80
ºC
Temperature Coefficient
0.05
%/ºC
Cooling
Convection
MTBF
@25ºC ambient temperature max. working load, according to MIL-HDBK-217 50,000
Hours
GENERAL SPECIFICATIONS
Height: 1m; the product should be felled off on the hardwood with the
thickness of 20mm, and the hardwood should be put on a cement base on or
Drop In
the ground without flexibility. Apply two times on all surfaces. Apply two times
on all corners.
The power supply will be burned-in for 4 hours under normal input and 80%
Burn-In
rated load at 40ºC±5ºC
Primary to Secondary:
3000VAC/ 10mA Max. /60 Seconds
Dielectric Strength (Hi-pot)
Primary to Secondary:
3300VAC/ 5mA Max. /3S
Leakage Current
@264VAC/50Hz
0.25
mA
Insulation Resistance
Primary to Secondary add 500VDC Test Voltage
50
MΩ
PHYSICAL SPECIFICATIONS
Weight
Approx. 5.29oz (150g)
3.46in x 1.97in x 1.81in
Dimensions (L x W x H)
(91.9mm x 45.4mm x 27.5in)
Short Circuit Protection
1/6/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 6
DTCGSW30 SERIES
15~30 Watts
AC DC Desktop Power Supplies
Single Output
Rev B
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
SAFETY & EMC CHARACTERISTICS
Regulatory Standards
Type
CE
FCC
SAA
(3)
EMI Standards
Country
Europe
USA
Australia
5V-9V Models
ESD
EN61000-4-2
Radiated Electromagnetic Field
Susceptibility
EN 61000-4-3
Electric Fast Transients (burst)
Immunity Requirement
EN 61000-4-4
Surge Capability Requirement
EN 61000-4-5
Induced Radio Frequency Fields
Conducted Disturbances Immunity
EN 61000-4-6
Acceptance Criteria
A
Assessment Criteria
B
C
EN55022
EN61000-3-2
FCC Part15
Standard
EN60950-1
UL60950
AS/NZ 60950.1
Class B
Discharge
Test Level
Test Criteria
Characteristic
Air Discharge
±8KV
B
Contact Discharge
±4KV
B
Test Level
Test Criteria
3V/m (r.m.s)
A
80-1000MHz
Coupling
Test Level
Test Criteria
AC-Input
0.5KV
A
AC-Input
1KV
B
Surge Voltage
Test Criteria
Common Mode ±2KV
A
Differential Mode ±1KV
Test Level
Test Criteria
3V
A
0.15-80 MHz, 80%AM
(1KHz)
Performance
Agreed operational behavior within the specified
limits
Time limited functional diminishment or
malfunction during the tests is permitted. The
function is self-reactivated by the unit following
completion of the tests.
Malfunction is permitted. The function can be
reactivated either by reconnection to the mains or
by operator intervention.
NOTES
(1)
(2)
(3)
1/6/2016
Ripple and Noise is measured by 20MHz bandwidth oscilloscope and the output paralleled a 0.1uF ceramic capacitor and a 10uF electrolysis
capacitor. (Test under the condition of rated input and rated output)
Efficiency measured Nominal input. Efficiency indicated is minimum.
Regulatory standards for 5V-9V Models
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 6
Rev B
DTCGSW30 SERIES
15~30 Watts
AC DC Desktop Power Supplies
Single Output
MECHANICAL DRAWINGS
PC + ABS Temperature: 95ºC
PC Material compliance with the ball pressure test requirments
DC Cord Drawing
1/6/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 4 of 6
Rev B
DTCGSW30 SERIES
15~30 Watts
AC DC Desktop Power Supplies
Single Output
Label Drawing
Package Drawing
Packing Details: 90pcs/carton, 12.5kg/carton, external carton size: 51cm x 39cm x 22cm
COMPANY INFORMATION
1/6/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 5 of 6
Rev B
DTCGSW30 SERIES
15~30 Watts
AC DC Desktop Power Supplies
Single Output
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
1/6/2016
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 6 of 6