Download Data Sheet

DTAM90/100 SERIES
90~110 Watts
Medical AC/DC Desktop Power Supplies
Single Outputs
Rev F
FEATURES
•
•
•
•
•
•
•
•
Class I
3-Pole IEC-320-C14 AC Inlet
RoHS Compliant
90~264VAC Input Voltage Range
Up to 110 Watts Output Power
Single Outputs
No Load Power Consumption <500mW
Power Factor: >0.95 at 115VAC and
Full Load
• Earth Leakage Current: <266µA at
264VAC
• Power ON LED Indicator
• Over Voltage, Over Load, and Short
Circuit Protection
• Meets CEC, ERP, EISA, and Energy Star
Level V Requirements
• UL60601-1: 3rd Edition Medical Approvals
• Optional Output Connectors Available
DESCRIPTION
The DTAM90/110 series of Class I desktop AC/DC power supplies delivers up to 110
Watts of output power in a 6.69” x 2.55” x 1.52” package. This series consists of
single output models with an input voltage range of 90-264VAC and a 3-pole IEC-320C14 AC inlet. These supplies are protected against over voltage, over load, and short
circuit conditions. The DTAM90/110 series is RoHS compliant and meets CEC, ERP,
EISA, and Energy Star Level V requirements. These units also have UL60601-1: 3rd
edition medical approvals.
Size: 6.69in x 2.55in x 1.52in (170mm x 64.8mm x 38.5mm)
MODEL SELECTION TABLE
Model Number
DTAM-090A-1Y120G
DTAM-090A-1Y135G
DTAM-100A-1Y150G
DTAM-110A-1Y190G
DTAM-110A-1Y200G
DTAM-110A-1Y240G
Input Voltage Range
90~264VAC
Output Voltage
12VDC
13.5VDC
15VDC
19VDC
20VDC
24VDC
Output Current
7.5A
6.67A
6.67A
5.8A
5.5A
4.6A
Ripple & Noise(1) Output Regulation Output Power Avg. Efficiency
120mVp-p
±5%
90W
135mVp-p
±5%
90W
150mVp-p
±5%
100W
>87%
190mVp-p
±3%
110W
200mVp-p
±3%
110W
240mVp-p
±3%
110W
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
INPUT SPECIFICATIONS
Input Voltage Range
Input Frequency
Min
Typ
Max
Unit
90
47
115/230
50/60
264
63
2
1
50
100
500
VAC
Hz
@90VAC
@264VAC
@115VAC, cold start, and 25ºC
@230VAC, cold start, and 25ºC
Input Current
Inrush Current
No Load Power Consumption
@115VAC and Full Load
@230VAC and Full Load
Power Factor
OUTPUT SPECIFICATIONS
Output Voltage
Output Regulation
Output Power
Output Current
Minimum Load
Ripple & Noise (20MHz bandwidth)
mW
-
See Table
See Table
See Table
See Table
0
Measured at 20MHz limited bandwidth with 0.1µF ceramic and 10µF
electrolytic capacitors across the output
@Full Load, 115VAC
Hold-Up Time
PROTECTION
Short Circuit Protection
Over Load Protection
Over Voltage Protection
ENVIRONMENTAL SPECIFICATIONS
Operating Case Temperature
Derate linearly 2.5% per ºC from 41 to 60ºC
Storage Temperature
Humidity
MTBF
@Full Load and 25ºC ambient temperature
5/31/2016
0.95
0.90
Arms
mA
See Table
>10
ms
Auto-Recovery
Auto-Recovery
Shutdown and Latch Off, AC Recycle
0
-10
10
100,000
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
60
+70
95
ºC
ºC
% RH
hours
Page 1 of 4
DTAM90/100 SERIES
90~110 Watts
Medical AC/DC Desktop Power Supplies
Single Outputs
Rev F
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
GENERAL SPECIFICATIONS
Efficiency
@average load
Earth Leakage Current
@264VAC
Min
Typ
Max
Unit
266
µA
87
PHYSICAL SPECIFICATIONS
Weight
%
1.34lbs (610g)
6.69in x 2.55in x 1.52in
(170mm x 64.8mm x 38.5mm)
3-Pole IEC-320-C14 Class I
Optional Output Connectors Available
Dimensions (L x W x H)
AC Inlet
Output Connector
SAFETY & EMC CHARACTERISTICS
UL/c-UL UL60601-1
TUV EN60601-1
CB IEC60601-1
EN60601-1-2
FCC Part 18
EN55011
CE
RoHS
Energy Level V
CEC
ERP
EISA
Safety Approvals
EMC Standards
Compliance
Class B
Class B
NOTES
(1)
Ripple & Noise is measured at oscilloscope 20MHz bandwidth by a 10µF electrolytic capacitor and a 0.1µF ceramic capacitor in parallel at output
connector.
DERATING CURVES
5/31/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 4
Rev F
DTAM90/100 SERIES
90~110 Watts
Medical AC/DC Desktop Power Supplies
Single Outputs
MECHANICAL DRAWINGS
Note:
1. AC Inlet: IEC320-C14 or IEc320-C6
2. Plastic Case Color: Black
3. Tolerance: ±1.0mm
4. Unit: mm
5/31/2016
Standard Output Cable
1. AWM 157 #14~16AWG 1C + SHIELDING, UL 80ºC 30V VW-1, 1050mm
2. Depends on customer’s requirements
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 4
Rev F
DTAM90/100 SERIES
90~110 Watts
Medical AC/DC Desktop Power Supplies
Single Outputs
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
5/31/2016
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 4 of 4