DTAM90/100 SERIES 90~110 Watts Medical AC/DC Desktop Power Supplies Single Outputs Rev F FEATURES • • • • • • • • Class I 3-Pole IEC-320-C14 AC Inlet RoHS Compliant 90~264VAC Input Voltage Range Up to 110 Watts Output Power Single Outputs No Load Power Consumption <500mW Power Factor: >0.95 at 115VAC and Full Load • Earth Leakage Current: <266µA at 264VAC • Power ON LED Indicator • Over Voltage, Over Load, and Short Circuit Protection • Meets CEC, ERP, EISA, and Energy Star Level V Requirements • UL60601-1: 3rd Edition Medical Approvals • Optional Output Connectors Available DESCRIPTION The DTAM90/110 series of Class I desktop AC/DC power supplies delivers up to 110 Watts of output power in a 6.69” x 2.55” x 1.52” package. This series consists of single output models with an input voltage range of 90-264VAC and a 3-pole IEC-320C14 AC inlet. These supplies are protected against over voltage, over load, and short circuit conditions. The DTAM90/110 series is RoHS compliant and meets CEC, ERP, EISA, and Energy Star Level V requirements. These units also have UL60601-1: 3rd edition medical approvals. Size: 6.69in x 2.55in x 1.52in (170mm x 64.8mm x 38.5mm) MODEL SELECTION TABLE Model Number DTAM-090A-1Y120G DTAM-090A-1Y135G DTAM-100A-1Y150G DTAM-110A-1Y190G DTAM-110A-1Y200G DTAM-110A-1Y240G Input Voltage Range 90~264VAC Output Voltage 12VDC 13.5VDC 15VDC 19VDC 20VDC 24VDC Output Current 7.5A 6.67A 6.67A 5.8A 5.5A 4.6A Ripple & Noise(1) Output Regulation Output Power Avg. Efficiency 120mVp-p ±5% 90W 135mVp-p ±5% 90W 150mVp-p ±5% 100W >87% 190mVp-p ±3% 110W 200mVp-p ±3% 110W 240mVp-p ±3% 110W SPECIFICATIONS All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS INPUT SPECIFICATIONS Input Voltage Range Input Frequency Min Typ Max Unit 90 47 115/230 50/60 264 63 2 1 50 100 500 VAC Hz @90VAC @264VAC @115VAC, cold start, and 25ºC @230VAC, cold start, and 25ºC Input Current Inrush Current No Load Power Consumption @115VAC and Full Load @230VAC and Full Load Power Factor OUTPUT SPECIFICATIONS Output Voltage Output Regulation Output Power Output Current Minimum Load Ripple & Noise (20MHz bandwidth) mW - See Table See Table See Table See Table 0 Measured at 20MHz limited bandwidth with 0.1µF ceramic and 10µF electrolytic capacitors across the output @Full Load, 115VAC Hold-Up Time PROTECTION Short Circuit Protection Over Load Protection Over Voltage Protection ENVIRONMENTAL SPECIFICATIONS Operating Case Temperature Derate linearly 2.5% per ºC from 41 to 60ºC Storage Temperature Humidity MTBF @Full Load and 25ºC ambient temperature 5/31/2016 0.95 0.90 Arms mA See Table >10 ms Auto-Recovery Auto-Recovery Shutdown and Latch Off, AC Recycle 0 -10 10 100,000 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] 60 +70 95 ºC ºC % RH hours Page 1 of 4 DTAM90/100 SERIES 90~110 Watts Medical AC/DC Desktop Power Supplies Single Outputs Rev F SPECIFICATIONS All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS GENERAL SPECIFICATIONS Efficiency @average load Earth Leakage Current @264VAC Min Typ Max Unit 266 µA 87 PHYSICAL SPECIFICATIONS Weight % 1.34lbs (610g) 6.69in x 2.55in x 1.52in (170mm x 64.8mm x 38.5mm) 3-Pole IEC-320-C14 Class I Optional Output Connectors Available Dimensions (L x W x H) AC Inlet Output Connector SAFETY & EMC CHARACTERISTICS UL/c-UL UL60601-1 TUV EN60601-1 CB IEC60601-1 EN60601-1-2 FCC Part 18 EN55011 CE RoHS Energy Level V CEC ERP EISA Safety Approvals EMC Standards Compliance Class B Class B NOTES (1) Ripple & Noise is measured at oscilloscope 20MHz bandwidth by a 10µF electrolytic capacitor and a 0.1µF ceramic capacitor in parallel at output connector. DERATING CURVES 5/31/2016 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 2 of 4 Rev F DTAM90/100 SERIES 90~110 Watts Medical AC/DC Desktop Power Supplies Single Outputs MECHANICAL DRAWINGS Note: 1. AC Inlet: IEC320-C14 or IEc320-C6 2. Plastic Case Color: Black 3. Tolerance: ±1.0mm 4. Unit: mm 5/31/2016 Standard Output Cable 1. AWM 157 #14~16AWG 1C + SHIELDING, UL 80ºC 30V VW-1, 1050mm 2. Depends on customer’s requirements Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 3 of 4 Rev F DTAM90/100 SERIES 90~110 Watts Medical AC/DC Desktop Power Supplies Single Outputs COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 5/31/2016 (603)778-2300 (888)597-9255 (603)778-9797 [email protected] www.wallindustries.com 37 Industrial Drive Exeter, NH 03833 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 4 of 4