Download Data Sheet

DTSPU131 SERIES
130 Watts
AC/DC Desktop Power Supplies
Single Output
Rev B
Size: 7.44in x 3.52in x 1.79in (188.9mm x 89.5mm x 45.5mm)
OPTIONS
FEATURES
• Output Voltage
• Output Cable
• ON/OFF Switch
•
•
•
•
•
APPLICATIONS
•
•
•
•
•
•
Class I
Single Output
RoHS Compliant
IEC-320-C14 Input Inlet
Over Voltage, Short Circuit, and Over Load
Protection
•
•
•
•
•
•
Efficiency Level VI (12V and 24V models)
Active Power Factor Correction
Optional Output Connectors Available
Output Voltages available from 12VDC to 55VDC
Optional On/Off Switch
Wide Input Voltage Range: 90 to 260VAC, 47~63Hz
DESCRIPTION
The DTSPU131 series of AC/DC desktop switching power supplies provides 130 watts of continuous
output power. This series consists of single output models with a 90~260VAC input voltage range and
an IEC-320-C14 input inlet connector for worldwide applications. These supplies also have short
circuit, over voltage, and over load protection. All units are UL94V-1, RoHS compliant, and 12V and
24V models are Energy Star 2.0 Level VI compliant, while the rest are compliant to Level V. All
models meet FCC Part-15 class B and CISPR-22 EN55022 class B emission limits and have UL/cUL
(UL 60950-1) and TUV/T-mark (EN 60950-1) safety approvals. This series also meets new CE
requirements and are 100% burn-in tested.
Printer
Industrial PC
Power Tools
DC Moto
AV Equipment
LED Lighting
MODEL SELECTION TABLE
Model Number
DTSPU131-105
DTSPU131-106
DTSPU131-107
DTSPU131-108
DTSPU131-109
DTSPU131-110
DTSPU131-111
DTSPU131-112
1/5/2016
Input Voltage
Range
Output
Voltage(1)
90~260VAC
12~13VDC
13~16VDC
16~21VDC
21~27VDC
27~33VDC
33~40VDC
40~50VDC
50~55VDC
Output Current
Min Load Max Load
10A
10.84A
8.12A
10A
6.19A
8.12A
4.81A
6.19A
3.93A
4.81A
3.25A
3.93A
2.60A
3.25A
2.36A
2.60A
Ripple &
Noise(2)
Total
Regulation
100 mVp-p
±5%
±5%
±5%
±3%
±3%
±3%
±3%
±3%
Output
Power
130W
No Load Power
Consumption
Efficiency
0.21W
VI
V
V
VI
V
V
V
V
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 1 of 4
DTSPU131 SERIES
130 Watts
AC/DC Desktop Power Supplies
Single Output
Rev B
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
INPUT SPECIFICATIONS
Safety Approval Input Voltage Range
Operate Voltage Range
Input Voltage Range
Input Frequency
Low Line
Input Current
High Line
Low Line
Input Inrush Current
High Line
Power Factor Correction
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation(3)
Load Regulation(4)
Output Power
Output Current
Ripple & Noise (Peak to Peak)
Transient Response Time
Start-Up Time
Hold-Up Time(5)
Temperature Coefficient
PROTECTION
Over Voltage Protection
Over Load Protection
Short Circuit Protection
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Surge Voltage
Electro Static Discharge
Vibration
Operating Altitude (Elevation)
Cooling
Flammability Rating
MTBF
GENERAL SPECIFICATIONS
Efficiency(6)
Dielectric Withstanding Voltage
Safety Ground Leakage Current
PHYSICAL SPECIFICATIONS
Weight
Full Load, Vin=100VAC
Full Load, Vin=240VAC
Full Load, 25ºC, Cool Start, Vin=100VAC
Full Load, 25ºC, Cool Start, Vin=240VAC
Io=Full Load, Vin=240VAC
100
90
47
264
260
63
1.58
0.64
30
50
1
0.95
VAC
Hz
A
A
See Table
Full load, Vin=100~120VAC
Vin=230VAC, 10~90% Load Change at Condition
1
5
3
See Table
See Table
100
Full Load, Vin=110VAC
Full Load, Vin=100~240VAC
Full Load, Vin=100VAC
Full Load, Vin=100~240VAC
4
2
16
±0.04
Recovers Automatically After Fault is Removed
Derate linearly from 100% load at 40ºC to 50% load at 70ºC
10~95% RH
Non-Condensing
mVp-p
mS
S
mS
%/ºC
112
110
132
150
Auto Recovery
%
%
0
-40
0
0
70
85
95
95
2
8
6
5
3000
Free Air Convention
UL94V-1
ºC
ºC
%RH
%RH
kV
All Conditions
Air Discharge, IEC61000-4-2
Contact Discharge, IEC61000-4-2
10~500Hz, 10min./1 cycle, 60 min. each along X, Y, Z, axes
All Conditions
Operating Temperature at 25ºC, Calculated per MIL-HDBK-217F
%
%
100,000
kV
G
m
Hours
See Table
Primary to Secondary
Primary to Ground
Vin=240VAC, Fi=60Hz
4242
2121
VDC
0.75
mA
Approx. 27.4~28.2oz (778~800g)
7.44in x 3.52in x 1.79in
(188.9mm x 89.5mm x 45.5mm)
Dimensions (L x W x H)
SAFETY & EMC CHARACTERISTICS
Safety Approvals
EMC Emission
UL/cUL UL60950-1: 2nd Edition
TUV/GS (EN 60950-1:2nd Edition)
Compliance to EN55022 (CISPR22), EN61000-3-2,-3
Class B
NOTES
(1)
(2)
(3)
(4)
(5)
(6)
1/5/2016
Output can provide up to peak load when the power supply starts up. Continuous staying in more than rated load is not allowed.
At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.
Ripple and Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load
and nominal line.
Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
Load regulation is defined by changing ±40% of measured output load from 60% rated load.
Hold-Up Time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at
rated load and nominal line.
Efficiency is measured at rated load, and nominal line.
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 4
Rev B
DTSPU131 SERIES
130 Watts
AC/DC Desktop Power Supplies
Single Output
DERATING CURVES
Input Voltage Derating Curve
Temperature Derating Curve
Recommended Output Cable
1.
2.
3.
4.
5.
Models DTSPU131-105~106 are required to use AWG#16*5C/4FT output cable in order to meet total regulation specified.
Models DTSPU131-107~108 are required to use AWG#16*5C/4FT output cable in order to meet total regulation specified.
Models DTSPU131-109~110 are required to use AWG#16*2C/4FT output cable in order to meet total regulation specified.
Models DTSPU131-111~112 are required to use AWG#18*2C /4FT output cable in order to meet total regulation specified.
The regulation and efficiency will changed if a different output cable is used.
MECHANICAL DRAWINGS
1/5/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 4
Rev B
DTSPU131 SERIES
130 Watts
AC/DC Desktop Power Supplies
Single Output
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
1/5/2016
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 4 of 4