PSHBU58 SERIES 60 Watts AC/DC Medical Open Frame Power Supplies Single Output Rev A Size: 4in x 1.50in x 1.04in (101.6mm x 38.1mm x 26.5mm) FEATURES • • • • • • Wide Operating Input Voltage of 80~275VAC Single Outputs Over Voltage, Over Load, and Short Circuit Protection Protection Class I Cooling by Free Air Convection High Efficiency up to 90% APPLICATIONS • • • • • • • • • • Output Power Up to 60 Watts Support Risk Management Process Input to Output: 2MOPP High ESD Immunity IEC60601-1 Edition 3.1, ES60601-1:2005(R2012), CSAC22.2 NO.60601-1:14, and EN60601-1:2006/A1:2013 Safety Approvals DESCRIPTION Breathing Therapy Devices Blood Pressure Systems Portable Medical Device ECG ` EEG Medical Tablets The PSHBU58 series of AC/DC medical open frame power supplies provide up to 60 watts of continuous output power. This series consists of single output models with a wide operating input voltage range of 80~275VAC and output voltages ranging from 5VDC to 55VDC. Each model is protected against short circuit, over voltage and over load conditions and have IEC60601-1 Edition 3.1, ES60601-1:2005(R2012), CSAC22.2 NO.6060-1-1:14, and EN60601-1:2006/A1:2013 safety approvals. MODEL SELECTION TABLE Model Number PSHBU58-102 PSHBU58-103 PSHBU58-104 PSHBU58-105 PSHBU58-106 PSHBU58-107 PSHBU58-108 PSHBU58-109 PSHBU58-110 PSHBU58-111 PSHBU58-112 11/10/2015 Input Voltage Range Setting Voltage Range(1) 80~275VAC 5~6VDC 6~8VDC 8~11VDC 11~13VDC 13~16VDC 16~21VDC 21~27VDC 27~33VDC 33~40VDC 40~50VDC 50~55VDC Output Current Min Load Max Load 5.50A 6.60A 5A 6.66A 4.54A 6.25A 4.61A 5.45A 3.75A 4.67A 2.85A 3.75A 2.22A 2.85A 1.81A 2.22A 1.50A 1.81A 1.20A 1.50A 1.09A 1.20A Ripple & Noise(6) No Load Consumption Output Power 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 0.5W 0.5W 0.5W 0.5W 0.5W 0.5W 0.5W 0.5W 0.5W 0.5W 0.5W 33W 40W 50W 60W 60W 60W 60W 60W 60W 60W 60W Total Regulation Efficiency(8) ±5% ±5% ±5% ±5% ±5% ±5% ±3% ±3% ±3% ±3% ±3% Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] 80% 82% 86% 87% 87% 87% 88% 88% 89% 90% 90% Page 1 of 4 PSHBU58 SERIES 60 Watts AC/DC Medical Open Frame Power Supplies Single Output Rev A SPECIFICATIONS All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS INPUT SPECIFICATIONS Safety Approval Input Voltage Range Input Operate Voltage Range Input Frequency Input Current Inrush Current Safety Ground Leakage Current OUTPUT SPECIFICATIONS Output Voltage Line Regulation(4) Total Regulation Output Power Output Current Ripple & Noise Transient Response Time Start-Up Time Hold-Up Time(7) Temperature Coefficient PROTECTION Short Circuit Protection Over Load Protection Over Voltage Protection ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Operating Humidity Storage Humidity Electro Static Discharge Operating Altitude Vibration Cooling Flammability Rating Surge Voltage MTBF GENERAL SPECIFICATIONS Efficiency Insulation Resistance Dielectric Withstanding Voltage Min Typ Max Unit Safety Approval & Specification in Label 100 240 VAC Derate linearly from 100% load at 90VAC to 80% load at 80VAC) Sine Wave Low Line Full Load, Vin=100VAC High Line Full Load, Vin=240VAC Low Line Full Load, 25ºC, Cool Start, Vin=100VAC High Line Full Load, 25ºC, Cool Start, Vin=100VAC Vin=240VAC, Fi=60Hz 80 47 275 63 1.2 0.6 30 60 0.25 VAC Hz A A mA See Table Full Load, Vin=100~120VAC or 200~240VAC PSHBU58-102 – PSHBU58-107 PSHBU58-108 – PSHBU58-112 Full Load, Vin=110VAC Full Load, Vin=100~240VAC 1 0.25 Full Load, Vin=100VAC All Conditions % 60 See Table See Table 4 0.5 12 ±0.04 Recovers automatically after fault condition is removed Crowbar Mode 110 110 Derate linearly from 100% load at 40ºC to 50% load at 70ºC 10~95% RH Non-Condensing -10 -40 0 0 W ms S ms %/ºC Automatic Recovery 150 275 70 85 95 95 Air Discharge, IEC61000-4-2 Contact Discharge, IEC61000-4-2 All Condition 10~500Hz, 10min./1cycle, 60min. each along X, Y, Z axes Line-Neutral Line-PE & Neutral PE Operating Temperature at 25ºC, Calculated per MIL-HDBK-217F % ±5 ±3 % % ºC ºC % RH % RH 3000 5 Free Air Convection UL94V-1 1 2 M G kV 100k Full Load, Vin=230VAC h See Table 50 MΩ Primary to Secondary, limit current <10mA Primary to PE, limit current <10mA PHYSICAL SPECIFICATIONS Weight 4000 1500 VAC 4.94oz (140g) 4.00in x 1.50in x 1.04in (101.6mm x 38.1mm x 26.5mm) Dimensions (L x W x H) SAFETY Safety Approvals EMC Emission Protection Classes 11/10/2015 IEC60601-1 Edition 3.1 ES60601-1: 2005 (R1012) CSAC22.2 NO.60601-1:14 EN60601-1:2006/A1:2013 Compliance to EN55011 (CISPR11), EN60601-1-2 Class B Class I Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 2 of 4 PSHBU58 SERIES 60 Watts AC/DC Medical Open Frame Power Supplies Single Output Rev A NOTES (1) (2) (3) (4) (5) (6) (7) (8) Setting voltage range is a factory setting and cannot be adjusted. Output can provide up to peak load when the power supply starts up. Continuous staying in more than rated load is not allowed. In 60% rated load condition, each output is checked to be within voltage accuracy. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. Load regulation is defined by changing ±40% of measured output load from 60% rated load. Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47µF capacitor at rated load and nominal line. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line. Efficiency is measured at rated load and nominal line. DERATING CURVES Input Voltage Derating Curve Temperature Derating Curve MECHANICAL DRAWINGS PIN 1 2 3 4 Notes: 1. 2. 3. 11/10/2015 PIN CHART PSHBU58-1XX RTN RTN OUT OUT Net Weight: 140g approx. Input Connector mates with Molex housing 09-50-3031/35977-0300 and Moles 2478/35922 series crimp terminal. Output connector mates with Molex housing 09-50-3061/35977-0600 and Molex 2478/35922 series crimp terminal. Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 3 of 4 Rev A PSHBU58 SERIES 60 Watts AC/DC Medical Open Frame Power Supplies Single Output COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 11/10/2015 (603)778-2300 (888)597-9255 (603)778-9797 [email protected] www.wallindustries.com 37 Industrial Drive Exeter, NH 03833 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 4 of 4