Download Data Sheet

DTSPU41A SERIES
30-40 Watt
Single Output
AC/DC Desktop Power Supply
Rev A
FEATURES
• Wide Operating Voltage: 90 to 264VAC,
47-63Hz
• IEC-320-C14 Input Inlet
• Single Output
• Class I
• Cooling by Free Air Convection
Size: 4.21in x 1.85in x 1.18in
• Optional Output Connectors Available
• Cooling by Free Air Convection
• UL/cUL (UL 60950-1:2nd Edition), TUV/GS
(EN60950-1:2nd Edition) Safety Approvals
• Energy Star 2.0, Efficiency Level VI
• Short Circuit and Over Load Protection
APPLICATIONS
DESCRIPTION
•
•
•
•
•
•
•
The DTSPU41A series of single output AC DC desktop power supplies
provides up to 40 watts of continuous output power. This series
includes IEC-320-C14 input for worldwide applications. All supplies are
UL 94V-1 min compliant and all models meet FCC Part 15- class B
and CISPR-22 class B emission. Limits are designed to comply with
UL/c-UL (UL 60950-1:2nd) edition, TUV/GS (EN 60950-1:2nd Edition)
and new CE requirements. All units are 100% burn-in tested.
POS System
AV Equipment
Portable Devices
Monitor
Charger
LED Lighting
Ethernet Hub
MODEL SELECTION TABLE
Model Number
Input Voltage Range
DTSPU41A-102
DTSPU41A-103
DTSPU41A-104
DTSPU41A-105
DTSPU41A-106
DTSPU41A-107
DTSPU41A-108
DTSPU41A-109
DTSPU41A-110
DTSPU41A-111
100~240Vac
Output Voltage Output Current
5~5.99 VDC
6.5~8 VDC
8~11 VDC
11~13 VDC
13~16 VDC
16~21 VDC
21~27 VDC
27~33 VDC
33~40 VDC
40~48 VDC
5.00A
3.75~4.61A
3.18~4.38A
3.07~3.64A
2.50~3.07A
1.90~2.50A
1.48~1.90A
1.21~1.48A
1.00~1.21A
0.83~1.00A
Ripple &
Noise(1)
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
Total
Regulation
5%
5%
5%
5%
5%
5%
3%
3%
2%
2%
Output
Power
30W
30W
35W
40W
40W
40W
40W
40W
40W
40W
No-Load Power
Efficiency(2)
Consumption (max.)
0.3W
83~90%
0.3W
83~90%
0.3W
83~90%
0.3W
83~90%
0.3W
83~90%
0.3W
83~90%
0.3W
83~90%
0.3W
83~90%
0.3W
83~90%
0.3W
83~90%
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
INPUT SPECIFICATIONS
Safety Approval Input Voltage Range
Input Operate Voltage Range
Input Frequency
Input Inrush Current
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation(5)
Load Regulation(6)
Output Power
Output Current
Ripple & Noise (Peak to Peak)
Transient Response Time
Start-Up Time
Hold-Up Time(7)
Temperature Coefficient
PROTECTION
Short Circuit Protection
Over Load Protection
12/3/2015
Typ
100
90
47
Low Line
High Line
Low Line
High Line
Input Current
Min
Io=Full Load, Vin=100VAC
Io=Full Load, Vin=240VAC
Full Load, 25ºC, Cool Start, Vin=100VAC
Full Load, 25ºC, Cool Start, Vin=240VAC
Max
Unit
240
264
63
0.93
0.93
45
90
VAC
VAC
VAC
A
A
See Table
Io=Full Load, Vin=100~120VAC
Vin=230VAC, 10~90% Load Change at Condition
0.5
4
%
%
4
2
10
±0.04
mS
S
mS
%/°C
See Table
See Table
See Table
Full Load, Vin=90VAC
Full Load, Vin=100VAC
Io=Full Load, Vin=100VAC
Io=Full Load, Vin=110VAC
All Outputs
Recovers automatically after fault condition is removed
1
5
110
Automatic Recovery
150
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
%
Page 1 of 4
DTSPU41A SERIES
30-40 Watt
Single Output
AC/DC Desktop Power Supply
Rev A
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Derate linearly from 100% load at 40ºC to 50% load at 70ºC
Storage Temperature
10~95%RH
Operating Humidity
Non-Condensing
Storage Humidity
Air Discharge, IEC61000-4-2
Electro Static Discharge
Contact Discharge, IEC61000-4-2
Operating Altitude
All Conditions
Vibration
10~500Hz, 10min./1cycle, 60 min. each along X, Y, Z axes
Line-Neutral
Surge Voltage
Line-PE & Neutral-PE
Flammability Rating
Cooling
MTBF
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
GENERAL SPECIFICATIONS
Efficiency
Io=Full Load, Vin=230VAC
Primary to Secondary
Dielectric Withstanding Voltage
Primary to PE
Isolation Resistance
Test Voltage=500VDC
Safety Ground Leakage Current
Vin=240VAC/60Hz
PHYSICAL SPECIFICATIONS
Weight
Min
0
-40
0
0
Typ
Max
70
85
95
95
8
6
3000
5
1
2
UL94V-1
Free Air Convection
100,000
Unit
°C
°C
%
%
kV
M
G
KV
Hours
83
90
4242
2550
50
0.75
%
VDC
VDC
MΩ
mA
Approx. 9.35~9.88oz (265~280g)
4.21in x 1.85in x 1.18in
(107±1.0mm x 47.0±1.0mm x 30.1±1.0mm)
Dimensions (L x W x H)
SAFETY & EMC CHARACTERISTICS
Safety Approvals(8)
EMC Emission
Protection Classes
UL/cUL (UL 60950-1:2nd Edition)
TUV/GS (EN 60950-1:2nd Edition)
Compliance to EN55022 (CISPR22)
Class I
NOTES
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
12/3/2015
Ripple and Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47µF capacitor at rated load
and nominal line.
Efficiency is measured at rated load and nominal line.
Output can provide up to peak load when the power supply starts up. Staying in more than rated load continually is not allowed.
Each output is checked to be within voltage accuracy at 60% rated load condition.
Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
Load regulation is defined by changing ±40% of measured output load from 60% rated load.
Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated
load and nominal line.
The DTSPUA-102 is available on NRCan mark.
DTSPU41-102~104 are required to use AWG#16/4FT output cable.
DTSPU41-105~107 are required to use AWG#18/4FT output cable.
DTSPU41-108~111 are required to use AWG#18/6FT output cable.
Regulation and efficiency will be changed by modified output cable.
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 4
Rev A
DTSPU41A SERIES
30-40 Watt
Single Output
AC/DC Desktop Power Supply
DERATING CURVES
Input Voltage Derating Curve
Temperature Derating Curve
MECHANICAL DRAWINGS
Packing:
Net weight: Approx. 265~280g
Optional output connectors available. Please call
factory for details.
12/3/2015
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 4
Rev A
DTSPU41A SERIES
30-40 Watt
Single Output
AC/DC Desktop Power Supply
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
12/3/2015
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]