DTHPU101 SERIES 100 Watts Medical AC/DC Desktop Power Supplies Single Outputs Rev B FEATURES • • • • • • • • • Class I Single Outputs RoHS Compliant Input to Output: 2MOPP Up to 90% High Efficiency IEC-320-C14 AC Inlet Active Power Factor Correction Free Air Convection Cooling Up to 100 Watts Output Power • 90-260VAC Input Voltage Range • Over Current, Short Circuit, and Over Voltage Protection • Energy Star 2.0, Efficiency Level V • IEC60601-1 Edition 3.1, ES60601-1:2005(R2012), CSAC22.2 NO.60601-1:14, EN60601-1:2006/A1:2013, UL/cUL, TUV T-Mark, CE Safety Approvals • Optional Output Connectors Available • 100% Burn-in Tested DESCRIPTION Size: 5.75 x 2.99 x 1.69 inches 146.0 x 76.0 x 43.0 mm The DTHPU101 series of class I medical AC/DC desktop power supplies provides up to 100 Watts of continuous output power in a 5.75” x 2.99” x 1.69” package. This series consists of single output models with a 90~260VAC wide input range and an IEC-320-C14 AC inlet. Some features include high efficiency up to 90%, 2MOPP insulation, and over current and over voltage protection. All units are UL94V-1, RoHS, and Energy Star 2.0 Level V compliant and meet FCC Part-18 class B and CISPR-11 EN55011 class B emission limits. This series also has IEC60601-1 Edition 3.1, ES60601-1:2005(R2012), CSAC22.2 NO.60601-1:14, EN60601-1:2006/A1:2013, UL/cUL, TUV T-Mark, CE safety approvals. All models have been 100% burn-in tested. MODEL SELECTION TABLE Output Voltage (1) Output Current DTHPU101-105 Input Voltage Range 90 ~ 260VAC 9.09 ~ 7.69 A Total Regulation ±5% No Load Power Consumption 0.5W Typical Efficiency 81% 11 ~ 13 VDC DTHPU101-106 90 ~ 260 VAC 13 ~ 16 VDC 7.69 ~ 6.25 A ±4% 0.5W 84% 100W DTHPU101-107 DTHPU101-108 90 ~ 260 VAC 16 ~ 21 VDC 6.25 ~ 4.76 A ±4% 0.5W 87% 100W 90 ~ 260 VAC 21 ~ 27 VDC 4.76 ~ 3.70 A ±4% 0.5W 87% 100W DTHPU101-109 90 ~ 260 VAC 27 ~ 33 VDC 3.70 ~ 3.03 A ±3% 0.5W 87% 100W DTHPU101-110 90 ~ 260 VAC 33 ~ 40 VDC 3.03 ~ 2.50 A ±3% 0.5W 87% 100W DTHPU101-111 90 ~ 260 VAC 40 ~ 48 VDC 2.50 ~ 2.08 A ±3% 0.5W 87% 100W Model Number 01/12/2016 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Output Power 100W Page 1 of 4 Rev B DTHPU101 SERIES 100 Watts Medical AC/DC Desktop Power Supplies Single Outputs SPECIFICATIONS: DTHPU101 SERIES All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit INPUT SPECIFICATIONS Safety Approvals Input Voltage Range Operating Input Voltage Range Input Voltage 100 90 47 Input Frequency Low Line Input Current High Line Low Line Inrush Current High Line No Load Power Consumption Power Factor Correction 100VAC, full load 240VAC, full load 115VAC, full load, 25°C, cold start 230VAC, full load, 25°C, cold start 230VAC, no load 230VAC, full load 0.95 LL to HL, full load 11~13V 13~27V 27~48V 0.5 -5 -4 -3 90VAC, full load 110VAC, full load 100VAC, full load 100VAC, Full load to half load 16 0.3 240 260 63 1.2 0.5 50 120 See Table 1 VAC Hz A A OUTPUT SPECIFICATIONS Output Voltage Line Regulation(3) Total Regulation Output Power Output Current Ripple & Noise (peak to peak)(4) Hold-up Time(5) Start-up Time Transient Response Time Temperature Coefficient See Table 1 +5 +4 +3 See Table See Table 100 % % mVp-p ms s ms %/°C 2 4 +0.04 -0.04 PROTECTION Over Voltage Protection Over Current Protection Short Circuit Protection Recovers automatically after fault condition is removed 112 110 132 150 Automatic Recovery % % GENERAL SPECIFICATIONS Efficiency Dielectric Withstanding Voltage Insulation Resistance Safety Ground Leakage Current 230 VAC, full load Primary to Secondary, limit current <10mA Primary to PE, limit current <10mA Primary to Secondary, 500VDC, 25ºXC/70% RH 240VAC/60Hz See Table 4000 1500 VDC MΩ mA 50 0.25 ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Cooling Electro Static Discharge Vibration Surge Voltage Flammability Rating MTBF Derating linearly from 100% Load at 40°C to 50% load at 70°C 10~95% RH Non-condensing -10 -40 0 0 All conditions Air Discharge, IEC61000-4-2 Contact Discharge, IEC61000-4-2 10~500Hz, 10min./1cycle, 60min. each along X,Y,Z axes Line-Neutral Line-PE & Neutral-PE MIL-HDBK-217F, 25°C +70 +85 95 95 Up to 3000m Free air convection 15 8 5 1 2 UL94V-1 100,000 °C °C % % kV G kV hours PHYSICAL SPECIFICATIONS Weight Dimensions (L x W x H) 1.08~1.48 lbs (490~670g) 5.75 x 2.99 x 1.69 inches (146.0 x 76.0 x 43.0 mm) SAFETY & EMC Safety Approvals EMI Requirements for CISPR-11 EMI Requirements for FCC PART-18 EMI Requirements for EN55011 01/12/2016 220VAC 110VAC IEC60601-1 Edition 3.1, ES60601-1:2005(R2012), CSAC22.2 NO.60601-1:14, EN60601-1:2006/A1:2013, UL/cUL, TUV T-Mark, CE B Class B Class B Class Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 2 of 4 Rev B DTHPU101 SERIES 100 Watts Medical AC/DC Desktop Power Supplies Single Outputs NOTES 1. The output voltage is specified as a range (ex: 40~48VDC); the customer must specify what they would like the output voltage set at. 2. This series needs to use AWG#18x3C + AWG#16x3C/4FT output cable in order to meet the total regulation specified. The regulation will change if a different output cable is used. 3. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 4. Ripple and noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load and nominal line. 5. Hold up time is measured from end of the last charging pulse to the time when the main output drops down to low limit of main output at rated load and nominal line. 6. Optional output connectors available. Please call factory for ordering details. DERATING CURVES Input Voltage Derating Curve Temperature Derating Curve MECHANICAL DRAWING Net Weight: (490~670g) Optional output connectors available 01/12/2016 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 3 of 4 Rev B DTHPU101 SERIES 100 Watts Medical AC/DC Desktop Power Supplies Single Outputs COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, welldocumented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 01/12/2016 (603)778-2300 (888)597-9255 (603)778-9797 [email protected] www.wallindustries.com 37 Industrial Drive Exeter, NH 03833 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 4 of 4