Download Data Sheet

DTAPU60 SERIES
60 Watts
AC/DC Desktop Power Supplies
Rev C
FEATURES
• Class I
• Single Outputs Ranging from 12VDC to 48
• RoHS2 Compliant
VDC
• 60 Watts Output Power
Size:
4.65 x 1.85 x 1.19 inches
118.0 x 47.0 x 30.3 mm
• UL 60950-1:2nd Edition, IEC 60950-
• Up to 88% High Efficiency
1:2005/A2:2013, EN60950-1:2006/A2:2013
• Energy Star 2.0, Efficiency Level VI
Safety Approvals
• 90-264VAC Input Voltage Range
• -40°C to +70°C Operating Temperature Range
• Free Air Convection
• IEC-320-C14 AC Inlet Connector
• Optional Output Connectors Available
SAFETY
Weight: 2oz (340g)
Applications:
• POS Systems
• AV Equipment
• Industrial PCs
• Chargers
• LED Lighting Applications
DESCRIPTION
The DTAPU60 series of AC/DC desktop power supplies provides 60 Watts of continuous output
power in a 4.65 x 1.85 x 1.19 inch package. This series consists of single output models ranging
from 12VDC to 48VDC with a 90~264VAC input voltage range and an IEC-320-C14 AC inlet
connector. Some features include high efficiency up to 88%, -40°C to +70°C operating
temperature range, and short circuit and over current protection. All units are UL 94V-1, RoHS2,
and CEC & Energy Star Level VI compliant. This series also meets FCC Part-15 class B and
CISPR-22 class B emission limits. All models meet new CE requirements and have UL 609501:2nd Edition, IEC 60950-1:2005/A2:2013, EN60950-1:2006/A2:2013 safety approvals. All units
have been 100% burn-in tested.
MODEL SELECTION TABLE
DTAPU60A-105
Output Voltage
Min
Max
12 VDC 13 VDC
Output Current
Min
Max
4.61 A
5.00 A
DTAPU60A-106
13 VDC
16 VDC
3.75 A
DTAPU60A-107
16 VDC
21 VDC
21 VDC
27 VDC
Model Number (1)
DTAPU60A-108
Input Voltage
Range
80 ~ 275VAC
Output
Power
60W
Typical
Efficiency
87.7%
Ripple &
Noise
100mVp-p
Total
Regulation
5%
4.61 A
60W
87.7%
100mVp-p
5%
2.85 A
3.75 A
60W
87.7%
100mVp-p
5%
2.22 A
2.85 A
60W
88%
100mVp-p
3%
DTAPU60A-109
27 VDC
33 VDC
1.81 A
2.22 A
60W
88%
100mVp-p
3%
DTAPU60A-110
33 VDC
40 VDC
1.50 A
1.81 A
60W
88%
100mVp-p
3%
DTAPU60A-111
40 VDC
48 VDC
1.25 A
1.50 A
60W
88%
100mVp-p
3%
08/14/2014
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 1 of 4
Rev C
DTAPU60 SERIES
60 Watts
AC/DC Desktop Power Supplies
TECHNICAL SPECIFICATIONS: DTAPU60 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
INPUT SPECIFICATIONS
Safety Approvals Input Voltage Range
Operating Input Voltage Range
Input Voltage
Input Frequency
Input Current
High Line Inrush Current
No Load Power Consumption
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
Load Regulation
Output Power
Output Current
Ripple & Noise (20MHz BW)
Hold-up Time
Start-up Time
Transient Response Time
Temperature Coefficient
No Load Consumption
PROTECTION
Over Load Protection
Short Circuit Protection
GENERAL SPECIFICATIONS
Efficiency
Full Load, Vin=100~120VAC
Vin=230VAC, 10~90% Load Change at Condition
90VAC, full load
100VAC, full load
100~240VAC, full load
110VAC, Full load
Full Load, Vin=100~240VAC
08/14/2014
Hz
A
A
W
See Table
1
5
60
See Table
100
0.5
3
%
%
W
mVp-p
ms
s
ms
%/°C
W
3
4
+0.04
-0.04
0.21
Recovers automatically after fault condition is removed
AC Inlet
Output Connector
SAFETY, EMC, & COMPLIANCE
CEC & Energy Star
VAC
10
Dimensions (L x W x H)
Compliance
240
264
63
1.45
1.45
105
0.5
Low Line; 100VAC, full load
High Line; 240VAC, full load
230VAC, full load, 25°C, cold start
230VAC, no load
230 VAC, full load
Primary to Secondary
Dielectric Withstanding Voltage
Primary to PE
Isolation Resistance
Test Voltage = 500VDC
Leakage Current
240VAC/60Hz
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Derating linearly from 100% Load at 40°C to 50% load at 70°C
Storage Temperature
10~95%RH
Operating Humidity
Non-Condensing
Storage Humidity
Cooling
Flammability Rating
Air Discharge, IEC61000-4-2
Electro Static Discharge
Contact Discharge, IEC61000-4-2
Operating Altitude
Vibration
10~500Hz, 10min./1cycle, 60min. each along X, Y, Z axes
Line-Neutral
Surge Voltage
Line-PE & Neutral-PE
MTBF
MIL-HDBK-217F, 25°C
PHYSICAL SPECIFICATIONS
Weight
Safety Approvals
100
90
47
110
150
Automatic Recovery
%
87
%
4242
2652
VDC
MΩ
mA
50
0.75
-40
-40
0
0
+70
+85
95
95
Free air convection
UL94V-1
8
6
2000
5
1
2
100,000
°C
°C
%RH
%RH
kV
m
G
kV
hours
12oz (340g)
4.65 x 1.85 x 1.19 in
(118.0 x 47.0 x 30.3 mm)
IEC-320-C14
Several options available
UL60950-1: 2nd Edition
IEC 60950-1:2005/A2:2013
EN60950-1:2006/A2:2013
RoHS2
CEC and Energy Star 2.0, Efficiency
Level VI
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 4
Rev C
DTAPU60 SERIES
60 Watts
AC/DC Desktop Power Supplies
NOTES
1. The output voltage is specified as a range (ex: 40~48VDC); the customer must specify what they would like the output voltage
set at.
2. DTAPU60A-105 need to use AWG#16/4FT output cable in order to meet all listed specifications.
Models DTAPU60A-106~111 need to use AWG#18/4FT output cable in order to meet all listed specifications.
The specifications will change if a different output cable is used.
3. Optional output connectors are available for this series. Please call factory for ordering details.
4. At factory, each output is checked to be within voltage accuracy in 60% rated load condition.
5. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
6. Load regulation is defined by changing ±40% of measured output load from 60% rated load
7. Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF
capacitor at rated load and nominal line.
8. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of
main output at rated load and nominal line.
Due to advances in technology, specifications are subject to change without notice.
MECHANICAL DRAWING
08/14/2014
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 4
Rev C
DTAPU60 SERIES
60 Watts
AC/DC Desktop Power Supplies
DERATING
Input Voltage Derating Curve
Temperature Derating Curve
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
08/14/2014
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 4 of 4