EL731 DeviceNet Manual

3714 Kinnear Place
Saskatoon, SK
Canada
S7P 0A6
Ph: (306) 373-5505
Fx: (306) 374-2245 www.littelfuse.com/relayscontrols
EL731 DEVICENET INTERFACE
Revision 0-B-121614
Copyright  2014 Littelfuse Startco
All rights reserved.
Document Number: PM-1010-EN
Printed in Canada.
EL731 DeviceNet Interface
This page intentionally left blank.
Page i
Rev. 0-B-121614
Page ii
Rev. 0-B-121614
EL731 DeviceNet Interface
TABLE OF CONTENTS
SECTION
DISCLAIMER
PAGE
1
2
3
General ................................................................. 1
Installation ........................................................... 1
DeviceNet ............................................................. 1
3.1 Configuration Software ......................................... 1
3.2 Configuration Settings .......................................... 1
3.3 Termination ........................................................... 1
3.4 Power Consumption .............................................. 1
3.5 EDS File ................................................................ 1
3.6 LED Indication...................................................... 1
4
Classes .................................................................. 2
Appendix A EL731 DeviceNet Interface
Revision History ............................................................. 6
LIST OF FIGURES
FIGURE
1
PAGE
LED Indicators....................................................... 1
LIST OF TABLES
TABLE
1
2
3
PAGE
EL731 DeviceNet Connections ............................. 1
NS – Network Status LED .................................... 1
MS – Module Status LED ..................................... 1
Specifications are subject to change without notice.
Littelfuse Startco is not liable for contingent or
consequential damages, or for expenses sustained as a
result of incorrect application, incorrect adjustment, or a
malfunction.
EL731 DeviceNet Interface
This page intentionally left blank.
Page iii
Rev. 0-B-121614
Page 1
Rev. 0-B-121614
EL731 DeviceNet Interface
3.6 LED INDICATION
1. GENERAL
This document describes the AC700-CUA-01
Communications Upgrade Adapter DeviceNet features
supported by the EL731.
Network
Status LED
Module
Status LED
2. INSTALLATION
To field-install an AC700-CUA Communications
Upgrade Adapter, disconnect the EL731 supply voltage,
remove the adapter-access cover, insert the adapter, and
retain with the supplied screws. Apply the supply
voltage.
3.1 CONFIGURATION SOFTWARE
FIGURE 1. LED Indicators.
TABLE 1. EL731 DEVICENET CONNECTIONS
TERMINAL
1
2
3
4
5
Retaining
Screws
DeviceNet
Interface
3. DEVICENET
DESCRIPTION
VCAN_L
SHIELD/DRAIN
CAN_H
V+
3.2 CONFIGURATION SETTINGS
The EL731 supports 125, 250, and 500 Kbit/s. The
MAC ID is adjustable from 0 to 63. The baud rate and
MAC ID are set using DeviceNet commands or the
RSNetworx Node Commissioning tool.
3.3 TERMINATION
DeviceNet requires a 120  resistor at each end of the
network.
3.4 POWER CONSUMPTION
The DeviceNet module requires 125 mA maximum
from an external 24 Vdc supply to power the driver
circuits.
3.5 EDS FILE
The EDS file is an Electronic Datasheet file that
defines the characteristics of the EL731. It is used by
configuration software such as RSNetWorx to setup the
EL731 on the network and allows DeviceNet scanners to
map EL731 I/O Data to PLC/PAC memory.
Only one I/O Polling assembly is supported,
consisting of four bytes for output and four bytes for
input. See Section 4.
STATE
TABLE 2. NS - NETWORK STATUS LED
DESCRIPTION
Steady Off
Steady Green
Flashing Green
Steady Red
Flashing Red
Alternating Red/Green
Not Online / No Power
Online, One Or More
Connections Are Established
Online, No Connections
Established
Critical Link Failure
One Or More Connections
Timed-Out
Self Test
NOTE: A test sequence is performed on this LED during
startup.
STATE
TABLE 3. MS - MODULE STATUS LED
DESCRIPTION
Steady Off
Steady Green
Flashing Green
Steady Red
Flashing Red
Alternating Red/Green
No Power
Operating In Normal Condition
Missing Or Incomplete
Configuration, Device Needs
Commissioning
Unrecoverable Fault(s)
Recoverable Fault(s)
Self Test
NOTE: A test sequence is performed on this LED during
startup.
Page 2
Rev. 0-B-121614
EL731 DeviceNet Interface
4. CLASSES
Assembly Class (4), Instance (0) Attributes
ATTRIBUTE
NUMBER
ATTRIBUTE
NAME
SERVICES
DESCRIPTION
DEFAULT,
MINIMUM,
MAXIMUM
DATA
TYPE
1
0x01
Revision
Get_Attribute_Single
Revision of this object.
1, 1, 1
UINT
Assembly Class (4), Instance (100), Attribute (3)
BYTE
DESCRIPTION
0
1
2
3
Assembly Class (4), Instance (150), Attribute (3)
BYTE
0
1
2
3
TYPE
Trip State
T12
Alarm State
T13
DESCRIPTION
TYPE
CT1 Enable
Command Register
CT2 Enable
Command Register
T3
T14
T3
T14
Application Data Class (162), Instance (0) Attributes
ATTRIBUTE
NUMBER
1
2
3
ATTRIBUTE
NAME
Revision
Max Instance
Number Of Instances
SERCVIES
VALUE
Get
Get
Get
1
76
76
DATA
TYPE
UINT
UINT
UINT
Application Data Class (162)
INSTANCE
NUMBER
ATTRIBUTE 1
NAME
ATTRIBUTE 2
DATA TYPE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Model Code
Firmware Revision
Serial Number
Model Option
Reserved
CT1 Enable
CT1 Primary Turns
CT1 Trip Time
CT1 Trip Level
Reserved
CT1 Alarm Level
CT1 Calibrate
Reserved
Reserved
CT2 Enable
CT2 Primary Turns
CT2 Trip Time
CT2 Trip Level
Reserved
CT2 Alarm Level
CT2 Input Filter
Reserved
Reserved
UINT16
UINT16
UINT32
UINT32
ATTRIBUTE 3
NUMBER OF
ELEMENTS
1
1
1
1
UINT16
UINT16
UINT32
UINT32
1
1
1
1
UINT32
UINT16
1
1
UINT16
UINT16
UINT32
UINT32
1
1
1
1
UINT32
UINT16
1
1
ATTRIBUTE 4
SERVICES
ATTRIBUTE 5
VALUE
Get
Get
Get
Get
Get
Get/Set
Get/Set
Get/Set
Get/Set
Get
Get/Set
Set
Get
Get
Get/Set
Get/Set
Get/Set
Get/Set
Get
Get/Set
Get/Set
Get
Get
T1
T1
T2
T2
T3
T1
T2
T2
T2
T4
T3
T1
T2
T2
T2
T5
Page 3
Rev. 0-B-121614
EL731 DeviceNet Interface
Application Data Class (162) (continued)
INSTANCE
NUMBER
ATTRIBUTE 1
NAME
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
Reserved
Reserved
PTC Trip Action
PTC Alarm Action
Reserved
Reserved
RTD Trip Action
RTD Trip Level
RTD Alarm Action
RTD Alarm Level
Reserved
Reserved
Relay 1 Function
Relay 1 Mode
Relay 2 Function
Relay 2 Mode
Relay 3 Function
Relay 3 Mode
Reserved
Reserved
Analog Out CT Select
Analog % Select
Output Filter
Reserved
Reserved
Temp. Sensor
Reserved
Reserved
Display Filter
Reserved
Reserved
CT1 Current
CT2 Current
Full Current
Internal Temp.
PTC Temp.
RTD Temperature
Reserved
Reserved
Clear Counters
Load Defaults
Restart System
Reserved
Reserved
Trip State
Alarm State
Trip Counter
Alarm Counter
System Uptime
Reserved
Reserved
Running Time (s)
External Reset
ATTRIBUTE 2
DATA TYPE
ATTRIBUTE 3
NUMBER OF
ELEMENTS
UINT16
UINT16
1
1
UINT16
UINT32
UINT16
UINT32
1
1
1
1
UINT16
UINT16
UINT16
UINT16
UINT16
UINT16
1
1
1
1
1
1
UINT16
UINT16
UINT16
1
1
1
UINT16
1
UINT16
1
SINT32
SINT32
SINT32
SINT32
SINT32
SINT32
1
1
1
1
1
1
UINT16
UINT16
UINT16
1
1
1
UINT16
UINT16
UINT16
UINT16
UINT32
1
1
1
1
1
UINT32
UINT16
1
1
ATTRIBUTE 4
SERVICES
Get
Get
Get/Set
Get/Set
Get
Get
Get/Set
Get/Set
Get/Set
Get/Set
Get
Get
Get/Set
Get/Set
Get/Set
Get/Set
Get/Set
Get/Set
Get
Get
Get/Set
Get/Set
Get/Set
Get
Get
Get/Set
Get
Get
Get/Set
Get
Get
Get
Get
Get
Get
Get
Get
Get
Get
Set
Set
Set
Get
Get
Get
Get
Get
Get
Get
Get
Get
Get
Set
ATTRIBUTE 5
VALUE
T3
T3
T3
T2
T3
T2
T6
T7
T6
T7
T6
T7
T8
T3
T3
T10
T3
T11
T11
T11
T11
T11
T11
T4
T4
T4
T12
T13
T1
T1
T2
T2
T4
Page 4
Rev. 0-B-121614
EL731 DeviceNet Interface
Attribute Data Types
ATTRIBUTE
1
2
3
4
5
Attribute 5 Data Format
TYPE
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
TYPE
Short String
USINT
0 = Boolean
1 = Signed 8 Bit Integer
2 = Signed 16 Bit Integer
3 = Signed 32 Bit Integer
4 = Unsigned 8 Bit Integer
5 = Unsigned 16 Bit Integer
6 = Unsigned 32 Bit Integer
USINT
USINT
Type Is Defined by Attribute 2
DESCRIPTION
16-Bit Integer
32-Bit Unsigned Integer
0 = Disable
1 = Enable
Command
1 = Send Command
CT2 Input Filter
0 = None
1 = Full Range
2 = 90 Hz Low Pass
3 = 190 Hz High Pass
4 = 3 kHz Low Pass
Relay Functions
0 = Trip
1 = Alarm
2 = Watchdog
3 = Current
Relay Mode
0 = Non-Fail-Safe
1 = Fail-Safe
Analog Out CT Select
0 = CT1
1 = CT2
2 = Both CT’s
Analog % Level
0 = 0 – 5A Normal Mode
1 = 0 – Trip Level (% Trip Level Mode)
Temp. Sensor
0 = Disabled
1 = RTD Sensor
2 = PTC Sensor
32-Bit Signed Integer, (High) Bits 31..16, (Low) Bits 15..0
EL731 DeviceNet Interface
Attribute 5 Data Format (continued)
TYPE
DESCRIPTION
T12
T13
T14
Trip Status
Bit0: 1 = System Running
Bit1: 1 = Trip Current CT1
Bit2: 1 = Trip Current CT2
Bit3: 1 = Trip User Test
Bit4: 1 = Trip CT1 Detect
Bit5: 1 = Trip CT2 Detect
Bit6: 1 = Trip NVRAM Error
Bit7: 1 = Calibrate
Bit8: 1 = Calibrate Init
Bit9: 1 = Trip Calibrate
Bit10: 1 = Trip PTC Sensor
Bit11: 1 = Trip RTD Sensor
Bit12: 1 = System Disabled
Alarm Status
Bit0: 1 = No Alarms
Bit1: 1 = CT1 Current
Bit2: 1 = CT2 Current
Bit3: 1 = PTC Sensor
Bit4: 1 = RTD Sensor
Bit5: 1 = System Disabled
Command Register: Sends Command when Charged from 0 to 3.
Page 5
Rev. 0-B-121614
Page 6
Rev. 0-B-121614
EL731 DeviceNet Interface
APPENDIX A
EL731 DEVICENET INTERFACE REVISION HISTORY
MANUAL RELEASE DATE
MANUAL REVISION
December 16, 2014
0-B-121614
July 9, 2014
0-A-070914
MANUAL REVISION HISTORY
REVISION 0-B-121614
SECTION 4
Attribute 5 data format, T13 (Bit0) updated.
REVISION 0-A-070914
Initial release.