Specification for a Combline Bandpass Filter MtronPTI P/N: 9429R I. General & Electrical Requirements: 1. Center Frequency (FO): 1621.25MHz 2. 1dB Bandwidth: 10.5MHz minimum (1616.0MHz to 1626.5MHz) 3. Insertion Loss (@ FO): 1.0dB maximum 4. Return Loss (within 1616.0MHz to 1626.5MHz): 14.0dB minimum 5. Attenuation (ref. to IL @ FO) DC to 1559.0MHz: 55dB minimum 1559MHz to 1585MHz: 36dB minimum 1585.0MHz to 1605.0MHz: 18dB minimum 1666MHz to 2500MHz: 28dB minimum 6. Operating Power Level: ≤ +30dBm (1-watt) CW, 10-watts peak (10% duty cycle) 7. ZIN/ZOUT: 50 nominal II. Environmental & Physical Requirements: 1. 2. 3. 4. 5. Temperature Range: Operating: -40°C to +85°C Storage: -55°C to +95°C Shock: Per MIL-STD-810(G), Method 516.6, Procedure VI Vibration: Per MIL-STD-810(G), Method 514.6, Category 9 Altitude: Operational to 40,000 feet Package: Size: 2.800” (L) x 2.500” (W) x 1.000” (H) Excluding connectors and tuning screws (See Drawing) Connectors: Right Angle SMA-Female (2 places) Materials: Filter Body: Machined aluminum Filter Finish: Silver Plated. Per ASTM B 700/MIL-C-26074, 0.2 to 0.3 mil Electroless Ni, 0.3minimum Silver plate Weight: < 9-ounces Page 1 of 2 The information contained herein is proprietary to MtronPTI and is submitted in confidence. This information may not be copied or divulged without the express written permission of MtronPTI Specification for a Combline Bandpass Filter MtronPTI P/N: 9429R III. Design Simulation Plots: IV. Datasheet Revision Table: Date 03/08/13 Rev. 0 Author BRM Details of Revision Original Release. Page 2 of 2 The information contained herein is proprietary to MtronPTI and is submitted in confidence. This information may not be copied or divulged without the express written permission of MtronPTI