EN

Product Specification
Dimensions
2 x M3 x 4
Full Frames
30
8 x M3 x 4
Monochrome
VCXU-23M
1/1.2”
1920 x 1200
VCXU-24M
1/1.2”
1920 x 1200
38
VCXU-31M
1/1.8”
2048 x 1536
120
VCXU-32M
1/1.8”
2048 x 1536
55
VCXU-50M
2/3"
2448 x 2048
76.9
VCXU-51M
2/3"
2448 x 2048
35
VCXU-23C
1/1.2”
1920 x 1200
165
VCXU-24C
1/1.2”
1920 x 1200
38
VCXU-31C
1/1.8”
2048 x 1536
120
VCXU-32C
1/1.8”
2048 x 1536
55
VCXU-50C
2/3"
2448 x 2048
76.9
VCXU-51C
2/3"
2448 x 2048
35
20
[max. fps]
22
Size
Resolution
165
3
8,9
37,8
6,25
8,2
6,15
System Requirements
Safety
Safety Precautions
Notice
See the User's Guide for the
complete safety instructions!
Conformity:
CE, RoHS
We declare, under our sole responsibility, that
the previously described Baumer VCXU cameras conform with the directives of the CE.
RoHS
All VCXU cameras comply with the recommendation of the European Union concerning
RoHS Rules.
CPU
Caution
Observe precautions for
handling electrostatically
sensitive devices!
▪▪ Protect the sensor from dirt and
moisture.
▪▪ Do not allow the camera to become
contaminated with foreign objects.
Environmental Requirements
Storage temp.
Operating temp.
Humidity
-10°C ... +70°C
see Heat Transmission
10 % ... 90 %
Non-condensing
Further Information
For further information about our products, please visit www.baumer.com
For technical issues, please contact our technical support:
[email protected] · Phone +49 (0)3528 4386-845 · Fax +49 (0)3528 4386-86
© Baumer Optronic GmbH · Badstrasse 30 · DE-01454 Radeberg, Germany
Technical data has been fully checked, but accuracy of printed matter is not guaranteed.
Subject to change without notice. Printed in Germany 06/16.
v1.1
11164112
6
Installation
Single-camera system
Multi-camera system
Recommended
Recommended
Intel(R) Core(TM) i5-2520M
Intel(R) Core(TM) i7-3770 CPU @
CPU @ 2.50GHz, Cores: 4
3.40GHz, Cores: 8
4 GB
8 GB
RAM
Operating
Microsoft Windows 7 32 / 64 bit systems (required for USB 3.0)
system
Microsoft® Windows® 8 32 / 64 bit systems (required for USB 3.0)
(OS)
Microsoft® Windows® 10 32 / 64 bit systems (required for USB 3.0)
®
20
29
3
Notice
Further technical details are available in the respective data sheets.
www.baumer.com/vision/login
CE
18
20
Latest software version and technical
documentation available at:
C-Mount
29
Color
Quick Start Guide
VCXU Cameras (USB 3.0)
ø 28,7
Sensor
Camera Type
®
Lens mount
Notice
Ensure the sensor and lens are not contaminated with dust and airborne
particles when mounting the support or the lens to the device!
The following points are very important:
▪▪ Install the camera in an environment that is as dust free as possible!
▪▪ Keep the dust cover (bag) on the camera for as long as possible!
▪▪ Hold the camera with the sensor downwards if the sensor is uncovered.
▪▪ Avoid contact with any of the camera‘s optical surfaces!
General Description
Heat Transmission
Images with USB 2.0 / LED signals
1
Caution
Caution
If the camera is connected to an USB2.0 port image transmission is
disabled by default. The camera consumes more than 2.5W which
is the maximum allowed by the USB2.0 specification.But there is a
possibility to activate the image transmission at your own risk!
Heat can damage the camera. Heat must be dissipated adequately
to ensure that the temperature does not exceed the values in the
table below.
This activation could damage your computer´s hardware!
2
4
No.
Description
No.
1
Lens mount (C-Mount)
2
Digital IO
3
4
Procedure
1. Open the camera in the Camera Explorer.
2. Select the Profile GenICam Guru.
3. Activate the Feature USB2 Support Enable in the category
Device Control.
4. Disconnect the data connection of the camera to the USB 2.0 port.
5. Connect the data connection of the camera to the USB 2.0 port.
→ Images will be transmitted via the USB 2.0 port.
3
Signal
Meaning
green flash
Power on
green
USB 3.0 connection
red
USB 2.0 connection
yellow
Readout active
red flash
Update
Description
LED
LED
USB 3.0 port
Data Interface / Digital IOs
Installation
▪▪ operate the cameras only in mounted condition
▪▪ mounting in combination with forced convection may provide proper
heat dissipation
T
Measurement Point
Measurement Point (T)
Maximum Temperature
65°C (149°F)
Troubleshooting
Installing the camera:
USB 3.0 (Micro B)
1 23 45
As there are numerous possibilities for installation, Baumer recommends no specific method for proper heat dissipation, but suggest the
following principles:
▪▪ Connect the camera to the USB connection on your PC using an appropriate
cable.
6 7 8 9 10
▪▪ If required, connect a trigger and / or flash to the digital IOs.
1
VBUS
6
MicB_SSTX-
2
D-
7
MicB_SSTX+
3
D+
8
GND_DRAIN
4
ID
9
MicB_SSRX-
5
GND
10
MicB_SSRX+
1. Check camera operation using the LED signals.
→ If LED is red:
• Camera is connected to USB 2.0 (settings possible).
2. Check connection using Windows Device Manager:
open wire
Digital IOs (on camera side)
wire colors of the connecting cable (ordered separately)
6
7
5
1
4
8
3
2
→ If device is not listed:
• Check the host controller power supply.
• Check USB 3.0 cable and connection.
→ If device is regularly not listed
• Check USB 3.0 driver installation.
1
GPIO (Line2)
white
5
Power VCC OUT1
grey
2
not connected
brown
6
OUT1 (Line3)
pink
3
IN1 (Line0)
green
7
GND GPIO
blue
4
GND IN1
yellow
8
GPIO (Line1)
red
Installation example
1 - PCI USB board
2 - USB cable
3 - Cable for trigger and flash