EN

Product Specification
Dimensions
VisiLine series – Innovative functionality / flexible installation
26
12
3,5
▪▪ Flexible assembly
▪▪ RGB and YUV interpolation algorithms on board
▪▪ Reliable transmission at 5000 Mbit/sec according to USB 3.0 standard
▪▪ Single cable solution for data and power
2 - M2 depth 3
Size
Full Frames
Resolution
4 - M3 depth 3
[max. fps]
3,5
8,7
1/4"
656 x 490
160
VLU-12M / VLU12C
1/3"
1288 x 960
42
640 x 480
376
1/3"
6,75
CMOS Sensor (monochrome / color)
VLU-03M / VLU-03C
33
26
8 - M3 depth 3
C-Mount
26
VLU-02M / VLU-02C
11
CCD Sensor (monochrome / color)
18
14,2
Quick Start Guide
VisiLine Cameras (USB3 Vision™)
33
26
Sensor
Camera Type
48,3
9,8
Pixel 0,0
3,5
26
Latest software version and technical
documentation available at:
www.baumer.com/vision/login
Safety
System Requirements
Installation
Lens mount
Safety Precautions
Notice
See the User's Guide for the
complete safety instructions!
CE
We declare, under our sole responsibility, that the previously described Baumer VLU cameras conform with the
directives of the CE.
RoHS
All VLU cameras comply with the recommendation of the
European Union concerning RoHS Rules.
CPU
Single-camera system
Multi-camera system
Recommended
Recommended
Intel(R) Core(TM) i5-2520M
Intel(R) Core(TM) i7-3770 CPU
CPU @ 2.50GHz, Cores: 4
@ 3.40GHz, Cores: 8
4 GB
8 GB
Caution
RAM
Observe precautions for
handling electrostatically
sensitive devices!
Operating
Microsoft Windows 7 32 / 64 bit systems (required for USB 3.0)
system (OS)
Microsoft® Windows® 8 32 / 64 bit systems (required for USB 3.0)
®
▪▪ Protect the sensor from dirt and
moisture.
▪▪ Do not allow the camera to
become contaminated with foreign
objects.
Environmental Requirements
Storage temp.
-10°C ... +70°C
Operating temp. see Heat Transmission
Humidity
10 % ... 90 %
Non-condensing
Further Information
For further information about our products, please visit www.baumer.com
For technical issues, please contact our technical support:
[email protected] · Phone +49 (0)3528 4386-0 · Fax +49 (0)3528 4386-86
© Baumer Optronic GmbH · Badstrasse 30 · DE-01454 Radeberg, Germany
Technical data has been fully checked, but accuracy of printed matter is not guaranteed.
Subject to change without notice. Printed in Germany 01/15.
v1.1
11135444
Notice
Further technical details are
available on the respective
data sheets.
®
Notice
Ensure the sensor and lens are not contaminated with dust and airborne particles when mounting the support or the lens to the device!
The following points are very important:
▪▪ Install the camera in an environment that is as dust free as possible!
▪▪ Keep the dust cover (bag) on the camera for as long as possible!
▪▪ Hold the printer with the sensor downwards if the sensor is uncovered.
▪▪ Avoid contact with any of the camera‘s optical surfaces!
General Description
LED signals
1
Heat Transmission
Caution
2
Heat can damage the camera. Heat must be dissipated adequately to
ensure that the temperatures do not exceed the values in the table below.
As there numerous options for installation, Baumer does not specify a
specific method for proper heat dissipation.
As there are numerous possibilities for installation, Baumer do not specifiy a specific method for proper heat dissipation, but suggest the following
principles:
LED
3
▪▪ operate the cameras only in mounted condition
▪▪ mounting in combination with forced convection may provide proper
heat dissipation
T
4
No.
Description
No.
1
Lens mount (C-Mount)
2
LED
3
Digial IO
4
Description
Signal
Meaning
USB 3.0 port
green
USB 3.0 connection
yellow
USB 2.0 connection
(settings possible, no image)
LED
Notice
Why can frames not be transferred over an USB 2.0 connection?
The camera needs to be supplied with more than 2.5W when transferring images.
With an USB 2.0 connection maximally 2.5W are available. Therefore switching off
of the frame transfer is necessary. However, adjustments are still possible.
Installation
Data Interface / Digital IOs
Measurement Point
Maximum Temperature
T
50°C (122°F)
Troubleshooting
USB 3.0 Micro B
1 23 45
1
6 7 8 9 10
6
VBUS
MicB_SSTX-
Installing the camera:
▪▪ Connect the camera to the USB
connection on your PC using an
appropriate cable.
→ If LED is yellow:
• Camera is connected to USB 2.0 (settings possible, no image).
▪▪ If required, connect a trigger and /
or flash to the digital IOs.
→ If LED is green:
• Check if camera is being used by another application.
• Otherwise reconnect camera / restart software.
2
D-
7
MicB_SSTX+
3
D+
8
GND_DRAIN
4
ID
9
MicB_SSRX-
5
GND
10
MicB_SSRX+
Digital IOs (M8 / 8 pins / wire colors of the connecting cable)
5
4
2
7
1
8
1
OUT 3
5
IO Power VCC
grey
2
not connected brown
6
OUT 1
pink
3
IN 1
green
7
not connected
blue
4
IO GND
yellow
8
OUT 2
red
white
Installation example
1 - PCI USB board
2 - USB cable
3 - Cable for trigger and flash
3
6
1. Check camera operation using the LED signals.
open wire
2. Check connection using Windows Device Manager:
→ If device is not listed:
• Check the host controller power supply.
• Check USB 3.0 cable and connection.
→ If device is regularly not listed
• Check USB 3.0 driver installation.