EN

Absolute encoders - bus interfaces
Solid shaft ø11 mm with EURO flange B10
Profibus DPV0 or DPV2 / 13 bit ST / 16 bit MT / Speed switch
PMG10 - Profibus DP
Features
–– Interface Profibus DPV0 or DPV2
–– Magnetic sensing method
–– Resolution: singleturn 13 bit, multiturn 16 bit
–– Function display via LEDs
–– Multiturn sensing with Energy Harvesting
technologie, without gear or battery
–– Two hybrid bearings, one at each end
–– Special protection against corrosion C5-M
Optional
–– Additional output incremental with zero pulse
Technical data - electrical ratings
Technical data - mechanical design
Voltage supply
10...30 VDC
Size (flange)
ø115 mm
Short-circuit proof
Yes
Shaft type
ø11 mm solid shaft
Consumption w/o load
≤200 mA
Flange
EURO flange B10
Initializing time
≤500 ms after power on
Protection DIN EN 60529
IP 66/IP 67
Interface
Profibus-DPV0/V2
Operating speed
≤6000 rpm
Function
Multiturn
Range of switching speed ±2...6000 rpm, default 6000 rpm
Transmission rate
9.6...12000 kBaud
Operating torque typ.
10 Ncm
Device adress
Rotary switch in bus cover
(type-specific)
Rotor moment of inertia
1 kgcm²
Admitted shaft load
≤450 N axial
≤650 N radial
Steps per turn
8192 / 13 bit
Number of turns
65536 / 16 bit
Materials
Additional outputs
Square-wave HTL
Square-wave TTL (RS422)
Housing: aluminium alloy
Shaft: stainless steel
Operating temperature
-40...+85 °C
Sensing method
Magnetic
Relative humidity
95 % non-condensing
Interference immunity
EN 61000-6-2
Resistance
Emitted interference
EN 61000-6-3
Programmable
parameters
Steps per revolution
Number of revolutions
Preset
Scaling
Rotating direction
IEC 60068-2-6
Vibration 30 g, 10-2000 Hz
IEC 60068-2-27
Shock 400 g, 1 ms
Corrosion protection
Diagnostic function
Position or parameter error
IEC 60068-2-52
Salt mist
Complies to ISO 12944-5:1998
Protective paint systems (C5-M)
Status indicator
DUO-LED in bus cover
4 LEDs in device back side
Weight approx.
2.7 kg (depending on version)
Connection
Approval
CE
Bus connecting box
Terminal box incremental
Technical data - electrical ratings (speed switches)
Interface
RS485
Switching accuracy
±2 % (or Digit)
Switching outputs
1 output (Open-Collector or
Solid State Relais)
Output switching capacity 30 VDC; ≤100 mA
≤20 ms
1
www.baumer.com/motion
9/6/2016
Switching delay time
Subject to modification in technic and design. Errors and omissions excepted.
–– Integrated speed switch, programmable
PMG 10 - picture similar
Absolute encoders - bus interfaces
Solid shaft ø11 mm with EURO flange B10
Profibus DPV0 or DPV2 / 13 bit ST / 16 bit MT / Speed switch
PMG10 - Profibus DP
Part number
PMG10
-S
H
.
1
.3
00
.A
Additional output *
0 Without
See also Tabelle “Additional output *”
Resolution multiturn
0 Without
6 16 bit
Voltage supply / interface
P0 10…30 VDC, Profibus-DPV0
P2 10…30 VDC, Profibus-DPV2
Connection
5 1x bus connecting box with 3 cable glands M16, radial
3 1x bus connecting box with 3 connectors M12, radial
F 1x bus connecting box with 3 cable glands M16, radial +
1x terminal box with 1 cable gland M20, radial
G 1x bus connecting box with 3 connectors M12, radial +
1x terminal box with 1 cable gland M20, radial
Shaft diameter
1 ø11 mm with key 4 mm
Protection
D IP 66 and IP 67, optimized for dusty environments
L IP 66 and IP 67, optimized for oily and wet environments
Flange
H EURO flange B10, shaft insulation hybrid bearing
* Only for connection F or G
2
www.baumer.com/motion
9/6/2016
Subject to modification in technic and design. Errors and omissions excepted.
Drehzahlschalter / Programmierung
Ohne
D With speed switch *
(Standard: Open Collector, Solid State Relais on request)
Absolute encoders - bus interfaces
Solid shaft ø11 mm with EURO flange B10
Profibus DPV0 or DPV2 / 13 bit ST / 16 bit MT / Speed switch
PMG10 - Profibus DP
Bestellbezeichnung - Tabellen
Accessories
Additional output *
Mounting accessories
0 (Without)
Q (8192 ppr TTL/HTL push-pull (Vin=Vout), 6 channels)
P (8192 ppr TTL (RS422), 6 channels)
G (5000 ppr TTL/HTL push-pull (Vin=Vout), 6 channels)
H (5000 ppr TTL (RS422), 6 channels)
K (4096 ppr TTL/HTL push-pull (Vin=Vout), 6 channels)
K 35
Spring washer coupling
for solid shaft ø6...12 mm
K 50
Spring washer coupling
for solid shaft ø11...16 mm
K 60
Spring washer coupling
for solid shaft ø11...22 mm
J (4096 ppr TTL (RS422), 6 channels)
7 (3072 ppr TTL/HTL push-pull (Vin=Vout), 6 channels)
8 (3072 ppr TTL (RS422), 6 channels)
9 (2048 ppr TTL/HTL push-pull (Vin=Vout), 6 channels)
4 (2048 ppr TTL (RS422), 6 channels)
5 (1024 ppr TTL/HTL push-pull (Vin=Vout), 6 channels)
6 (1024 ppr TTL (RS422), 6 channels)
1 (512 ppr TTL/HTL push-pull (Vin=Vout), 6 channels)
3
www.baumer.com/motion
9/6/2016
Subject to modification in technic and design. Errors and omissions excepted.
2 (512 ppr TTL (RS422), 6 channels)
Absolute encoders - bus interfaces
Solid shaft ø11 mm with EURO flange B10
Profibus DPV0 or DPV2 / 13 bit ST / 16 bit MT / Speed switch
PMG10 - Profibus DP
Profibus-DP V0 - Terminal assignment
Profibus-DP V0 - Features
View A1) - View inside bus connecting box
A
B
UB
GND
A
B
UB
GND
Termination
Bus protocol
Profibus-DP V0
Profibus-Features
Device Class 1 and 2
Data Exch.
functions
Input: Position value
Output: Preset value
Preset value
The „Preset“ parameter can be
used to set the encoder to a predefined value that corresponds to a
specific axis position of the system.
Parameter
functions
Rotating direction:
The relationship between the rotating direction and rising or falling
output code values can be set in the
operating parameter.
Scaling:
The parameter values set the number of steps per turn and the overall
resolution.
Diagnostic
The encoder supports the following
error messages:
- Position error
Default settings
User address 00
User address
View C1) - View into connector „Voltage supply“
male
Connection Description
1
UB
3
GND
4
Voltage supply 10...30 VDC
Ground connection for UB
3
Profibus-DP V0 - Termination
both ON = final user
both OFF = user X
2
Connector M12 (male)
4-pin, A-coded
View D1) / View E1) - View into connector „Data transmission“
Profibus-DP V0 - User address
male /
female Connection Description
2
A
Negative serial data transmission
4
B
Positive serial data transmission
Defined by rotary switch.
Example: User address 23
5
5
4
3
3
4
1
2
2
1
Connector M12 (male, D1)) Connector M12 (female, E1))
5-pin, B-coded
5-pin, B-coded
Terminals of the same significance are internally connected
and identical in their functions. Max. load on the internal
terminal connections UB-UB and GND-GND is 1 A each.
see dimensions
4
www.baumer.com/motion
9/6/2016
1)
Subject to modification in technic and design. Errors and omissions excepted.
1
Absolute encoders - bus interfaces
Solid shaft ø11 mm with EURO flange B10
Profibus DPV0 or DPV2 / 13 bit ST / 16 bit MT / Speed switch
PMG10 - Profibus DP
Profibus-DP V2 - Terminal assignment
Profibus-DP V2 - Features
View A1) - View inside bus connecting box
A
B
UB
GND
A
B
UB
GND
Termination
Bus protocol
Profibus-DP V2
Profibus-Features
Device Class 3 and 4
Data Exch.
functions
Input: Position value
Output: Preset value
Preset value
The „Preset“ parameter can be
used to set the encoder to a predefined value that corresponds to a
specific axis position of the system.
Parameter
functions
Rotating direction:
The relationship between the rotating direction and rising or falling
output code values can be set in the
operating parameter.
Scaling:
The parameter values set the number of steps per turn and the overall
resolution.
Diagnostic
The encoder supports the following
error messages:
- Position error
Default settings
User address 00
User address
View C1) - View into connector „Voltage supply“
male
Connection Description
1
UB
3
GND
4
Voltage supply 10...30 VDC
Ground connection for UB
3
Profibus-DP V2 - Termination
both ON = final user
both OFF = user X
2
Connector M12 (male)
4-pin, A-coded
View D1) / View E1) - View into connector „Data transmission“
Profibus-DP V2 - User address
male /
female Connection Description
2
A
Negative serial data transmission
4
B
Positive serial data transmission
Defined by rotary switch.
Example: User address 23
5
5
4
3
3
4
1
2
2
1
Connector M12 (male, D1)) Connector M12 (female, E1))
5-pin, B-coded
5-pin, B-coded
Terminals of the same significance are internally connected
and identical in their functions. Max. load on the internal
terminal connections UB-UB and GND-GND is 1 A each.
see dimensions
5
www.baumer.com/motion
9/6/2016
1)
Subject to modification in technic and design. Errors and omissions excepted.
1
Absolute encoders - bus interfaces
Solid shaft ø11 mm with EURO flange B10
Profibus DPV0 or DPV2 / 13 bit ST / 16 bit MT / Speed switch
PMG10 - Profibus DP
Incremental - Output signals
Speed switch/incremental Terminal significance
+UB
Version with additional incremental output
at positive rotating direction
Voltage supply
Ground
A+
A_
Channel A+
Channel A _ (channel A+ inverted)
A+
B+
B_
Channel B+
Channel B _ (channel B+ inverted)
A-
R+
R_
Zero pulse (reference signal)
Zero pulse inverted
nE+
nE _
System OK+ / error output
System OK _ / error output inverted
SP+1)
SP _1)
DSL_OUT1 / speed switch (open-collector)
BR+
(Zero pulse+)
DSL_OUT2 / speed switch (0 V)
SA1)
RS485+ / programming interface
RS485 _ / programming interface
1)
R(Zero pulse-)
Speed switch - Switching characteristics
Speed switch/incremental Terminal assignment terminal box
SP+1)
A+
_
A
B+
_
B
+UB
High impedance
2)
Resistance
between
SP+ and SP-
SP-1)
nE+
_
nE
R+
_
R
SA1)
SB1)
Low impedance
-n
-ns
(off)
-ns
(on)
0
+ns
(on)
+ns
(off)
+n
n
= Speed
ns (on) = Adjusted switching on speed
ns (off) = Adjusted switching off speed
1)
2)
Do not use at version without speed switch
See dimensions
6
www.baumer.com/motion
Subject to modification in technic and design. Errors and omissions excepted.
View B
90°
9/6/2016
SB
B+
Absolute encoders - bus interfaces
Solid shaft ø11 mm with EURO flange B10
Profibus DPV0 or DPV2 / 13 bit ST / 16 bit MT / Speed switch
PMG10 - Profibus DP
Dimensions
Speed switch (option)
Additional output incremental (option)
Positive rotating direction
B
A
3x M16x1.5
(Cable ø5-9)
Profibus
7
145
7
www.baumer.com/motion
9/6/2016
Subject to modification in technic and design. Errors and omissions excepted.
C D E