C-Series C-Series REMOTE OPERATED CIRCUIT BREAKER The C-Series remote operated circuit breaker consists of a custom designed remote operated motor module (housed within a circuit breaker molding) coupled to a C-Series hydraulic-magnetic circuit breaker. The remote operated circuit breaker (ROCB) offers the convenience of remote ON, OFF, and Reset capability combined with the safety and accuracy of a standard magnetic current sensing device. This allows operation of the circuit breaker from various locations in a system, facility or site without sacrificing the ability to manually operate the breaker if required. Service, diagnostics, load shedding and power distribution control functions can now be performed in areas that were previously unattended, inaccessible. The ROCB module can be mounted on either side of the host breaker, while occupying only the width of a standard C-Series pole. Several interface methods are available. Product Highlights: ON-OFF and trip indication Load shedding Energy management Compact size Automatic reset capable Choice of interface styles Panel mounting Manual Operation Override Fits into industry standard cut-out ROCB Motor Specifications: Voltage input: 12 VDC to 80 VDC Start current: < 1 amp Switching time: < 2 seconds Operating Temperature: -25˚C to 80˚C Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: [email protected] Application Support: [email protected] Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | Circuit Breaker Accessories - ROCB - Ordering Scheme To order a remote operated circuit breaker, add / plus the remote module part number to the end of the C-Series circuit breaker catalog number. ex. CA1BO24620121C/RB1110BU1C Match color & mounting inserts of breaker. / RB 1 1 10 B U 1 C 1 Series 2 Mounting Position 3 Interface 6 Actuator Color 7 Mounting Insert 8 Agency Approval 5 VOLTAGE RATING A 12 VDC B 20-40 VDC C 41-80 VDC 1 SERIES RB 2 MOUNTING POSITION As viewed from back of breaker, line side up, pole 1 left. 1 Left Side 2 Right Side 3 INTERFACE 1 Flying Leads 2 Integral Connector 3 Flying Leads with 4 pin dual row connector (female) 4 Flying Leads with 4 pin dual row connector (male) 4 LEAD LENGTH 00 No Lead 011” 02 2” 033” 044” 05 5” 06 6” 07 7” 088” 099” 4 5 Lead Length Voltage Rating 1010” 1111” 1212” 1313” 1414” 1515” 1616” 1717” 1818” 1919” 2020” 2121” 2222” 2323” 2424” 2525” 2626” 2727” 2828” 2929” 3030” 6 ACTUATOR COLOR TWhite UBlack VRed WYellow 7 MOUNTING INSERT 1 6-32 x 0.195” 2 ISO M3 x 5mm 8 AGENCY APPROVAL C UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted G UL 489 Listed & CSA Certified I UL 1500 Ignition Protected,UL Recognized & CSA Accepted J UL 489 Listed, CSA Certified & TUV Certified Notes: Integral and 4-pin dual row connectors not available with agency approval J or G: UL 489. *Manufacturer reserves the right to change product specification without prior notice. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Circuit Breaker Accessories - ROCB - Dimensional Specifications | 3 Dimensional Specifications: in. [mm] #6-32[M3] THREAD X .195[4.95] DEEP (2 PLCS PER POLE) 2.062[52.37] 1.438[36.52] WIRE LEADS .750[19.05] DUAL ROW CONNECTOR USE AMP CONNECTOR P/N'S 172167-1(HOUSING) AND 770988-1/171639-1 (PINS) (NOT SUPPLIED) 2.500[63.50] 60° .150[3.81] 30° INTEGRAL CONNECTOR USE MOLEX P/N'S 87369-0400 (HOUSING) AND 50212 (PINS) (NOT SUPPLIED) 2.079[52.80] INTEGRAL CONNECTOR VERSION CONNECTOR WITH LEADS PANEL CUTOUT DETAIL TOLERANCES ±.005 [.12] 3.040 [77.22] CUSTOMER SUPPLIED FORM C SWITCH OR RELAY 2.280 [57.91] 1.520 [38.61] .156 DIA. [3.96] .760 [19.30] 2 PLC'S TYP. PER POLE OFF REMOTE OPERATOR MODULE OFF 1.448 [36.78] + ON 2.062 [52.37] CUSTOMER SUPPLIED VOLTAGE SOURCE .750 [19.05] ROCB TYP .432 [10.97] 1 POLE 2 POLE 3 POLE Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 4 | Circuit Breaker Accessories - ROCB - Wire Instructions - 12VDC Module Wire Instructions CATALOG INTERFACE OPTION 1 (FLYING LEADS) WIRING INSTRUCTIONS CATALOG INTERFACE OPTION 2 (INTEGRAL CONNECTOR) WIRING INSTRUCTIONS BLUE CATALOG INTERFACE OPTION 1 (FLYING LEADS) WIRING ON RED INSTRUCTIONS + _ BLACK BLUE RED CUSTOMER SUPPLIED FORM C SWITCH OR RELAY C DC Source _ OFF CUSTOMER SUPPLIED FORM C SWITCH OR RELAY ON ON + 4321 CUSTOMER SUPPLIED FORM C CUSTOMER INTERFACE SWITCH OR RELAY ROCB 4321 CATALOG INTERFACE OPTION 3 (FLYING LEADS WITH 4 PIN DUAL ROW CONNECTOR) WIRING INSTRUCTIONS CUSTOMER INTERFACE ROCB ROCB BLUE CATALOG INTERFACE OPTION 3 (FLYING LEADS REDWITH 4 PIN DUAL ROW CONNECTOR) WIRING INSTRUCTIONS + DC Source _ BLACK BLUE RED C USE MOLEX P/Ns 87369-000 (HOUSING) DC50212 (PINS) OFF AND Source (NOT SUPPLIED) CUSTOMER _ SUPPLIED FORM C CUSTOMER SWITCH INTERFACE OR RELAY OFF _ BLACK + 4321 C DC Source ROCB + C OFF 4321 DC Source CATALOG INTERFACE OPTION 2 (INTEGRAL CONNECTOR) ON WIRING INSTRUCTIONS USE MOLEX P/Ns 87369-000 (HOUSING) AND 50212 (PINS) (NOT SUPPLIED) CUSTOMER INTERFACE ON C OFF CUSTOMER SUPPLIED FORM C SWITCH OR RELAY USE AMP P/Ns 172167-1 (HOUSING) AND 770988-1/171639-1 (PINS) (NOT SUPPLIED) ON + C DC OFF Source CUSTOMER _ INTERFACE CUSTOMER ROCB SUPPLIED FORM C ARTWORK FILE: PROPRIETARY NOTE: NOTICE TO ALL PERSONS RECEIVING THIS DRAWING. THIS DOCUMENT IS THE PROPERTY OF CARLING TECHNOLOGIES, INC. AND IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART OR USED FOR MANUFACTURING PURPOSES BY ANYONE WITHOUT THE CONSENT OF CARLING TECHNOLOGIES, INC. ARTWORK FILE: BLACK IST-0002B TITLE ROCB WIRING INSTRUCTIONS NOTICE TO ALL PERSONS RECEIVING THIS DRAWING. THIS DOCUMENT IS THE PROPERTY OF CARLING TECHNOLOGIES, INC. AND IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART OR USED FOR MANUFACTURING PURPOSES BY ANYONE WITHOUT THE CONSENT OF CARLING TECHNOLOGIES, INC. DATESWITCH OR RELAY MJ 8-30-00 USE AMP P/Ns 172167-1 (HOUSING) DRAWING NO. REV AND 770988-1/171639-1 (PINS) (NOT SUPPLIED) IST-0002 DESCRIPTION 12 VOLT ROCB IST-0002B PROPRIETARY NOTE: DR BY TITLE ROCB WIRING INSTRUCTIONS DESCRIPTION 12 VOLT C SHEET CUSTOMER INTERFACE 1 OF 2 DR BY DATE MJ 8-30-00 DRAWING NO. REV IST-0002 C SHEET REVISIONS REV DESCRIPTION DATE A B C RELEASED PER ECN A6063 SEE ECO B2982 SEE ECO C5247 8-30-00 8-27-01 12-5-05 REVISIONS REV DESCRIPTION DATE A B C RELEASED PER ECN A6063 SEE ECO B2982 SEE ECO C5247 8-30-00 8-27-01 12-5-05 1 OF 2 Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Circuit Breaker Accessories - ROCB - Wire Instructions - 20-80VDC Module | 5 Wire Instructions CATALOG INTERFACE OPTION 2 (INTEGRAL CONNECTOR) WIRING INSTRUCTIONS CATALOG INTERFACE OPTION 1 (FLYING LEADS) WIRING INSTRUCTIONS BLUE RED ON ON CATALOG INTERFACE OPTION 2 (INTEGRAL CONNECTOR) + WIRING INSTRUCTIONS C CATALOG INTERFACE OPTION 1 (FLYING LEADS) + C WIRING INSTRUCTIONS DC OFF _ CUSTOMER SUPPLIED FORM C SWITCH OR RELAY ORANGE BLUE RED 4321 OFF 4321 _ CUSTOMER CUSTOMER INTERFACE BLACK ROCB SUPPLIED FORM C SWITCH OR RELAY ORANGE CATALOG INTERFACE OPTION 3 (FLYING LEADS WITH FEMALE 4 PIN DUAL ROW CONNECTOR) WIRING INSTRUCTIONS ROCB CATALOG INTERFACE OPTION 4 321 USE MOLEX P/NsCONNECTOR) 87369-0400 (HOUSING) (FLYING LEADS WITH4MALE 4 PIN DUAL ROW AND 50212 (PINS) WIRING INSTRUCTIONS (NOT SUPPLIED) ROCB CUSTOMER INTERFACE CUSTOMER SUPPLIED FORM C SWITCH OR RELAY BLACK BLUE CATALOG INTERFACE OPTION 4 (FLYING LEADS WITH MALE 4 PIN DUAL ROW RED CONNECTOR) + WIRING INSTRUCTIONS ON C OFF _ DC Source _ CUSTOMER SUPPLIED FORM C SWITCH OR RELAY OFF CUSTOMER SUPPLIED FORM C SWITCH OR RELAY ORANGE BLUE USE AMP P/Ns 172167-1 (HOUSING) AND 770988-1/171639-1 (PINS) + (NOT SUPPLIED) RED DC Source ROCB ARTWORK FILE: ON C OFF _ ORANGE PROPRIETARY NOTE: NOTICE TO ALL PERSONS RECEIVING THIS DRAWING. THIS DOCUMENT IS THE PROPERTY OF CARLING TECHNOLOGIES, INC. AND IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART OR USED FOR MANUFACTURING PURPOSES BY ANYONE WITHOUT THE CONSENT OF CARLING TECHNOLOGIES, INC. ARTWORK FILE: ROCB TITLE USE AMP P/Ns 172167-1 (HOUSING) AND 770988-1/171639-1 (PINS) (NOT SUPPLIED) ROCB WIRING INSTRUCTIONS DESCRIPTION _ CUSTOMER INTERFACE 20-80 VOLT 2-7-00 IST-0001 TITLE ROCB WIRING INSTRUCTIONS DESCRIPTION 20-80 VOLT C B CUSTOMER INTERFACE SHEET C DR BY DRAWING NO. IST-0001 1 DATE OF 2 2-7-00 REV C SHEET ROCB ORANGE REVISIONS REV DESCRIPTION DRAWING NO. BOARD MOUNT REV 770607-1 SEE AMP FOR OR CIRCUIT A OPTIONS RELEASED PER ECN A5102 ALTERNATE CONNECTOR MJ PROPRIETARY NOTE: NOTICE TO ALL PERSONS RECEIVING THIS DRAWING. THIS DOCUMENT IS THE PROPERTY OF CARLING TECHNOLOGIES, INC. AND IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART OR USED FOR MANUFACTURING PURPOSES BY ANYONE WITHOUT THE CONSENT OF CARLING TECHNOLOGIES, INC. BLACK DATE USE AMP P/Ns 172159-1 (HOUSING) AND 770987-1 (PINS) (NOT SUPPLIED) MJ CUSTOMER INTERFACE IST-0001B RED + C OR CIRCUIT BOARD MOUNT 770607-1 SEE AMP FOR DC OFF ALTERNATE Source CONNECTOR OPTIONS DR BY IST-0001B BLACK ORANGE BLUE USE AMP P/Ns 172159-1 (HOUSING) AND 770987-1 (PINS) (NOT SUPPLIED) ON CUSTOMER INTERFACE BLACK CUSTOMER INTERFACE CUSTOMER SUPPLIED FORM C SWITCH OR RELAY BLUE CATALOG INTERFACE OPTION 3 ON (FLYING LEADS RED WITH FEMALE 4 PIN DUAL ROW CONNECTOR) + WIRING INSTRUCTIONS C DC Source CUSTOMER SUPPLIED FORM C SWITCH OR RELAY USE MOLEX P/Ns 87369-0400 ON (HOUSING) AND 50212 (PINS) + (NOT SUPPLIED) C DC OFF Source CUSTOMER INTERFACE _ CUSTOMER SUPPLIED FORM C SWITCH OR RELAY C DC Source OFF _ ON + ROCB DC Source 4321 Source BLACK SEE ECO B1680 SEE ECN B2982 DATE 02-07-00 04-16-01 ROCB 08-27-01 REVISIONS REV A B C DESCRIPTION RELEASED PER ECN A5102 SEE ECO B1680 SEE ECN B2982 1 OF 2 Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com DATE 02-07-00 04-16-01 08-27-01 6 | Notes Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Reps & Contact | 7 Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Matrix DM Mexico South America Mexico « « Sunbelt Components SOUTHEAST ProRep Solutions LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: [email protected] Northern Region Sales Office: [email protected] Southeast Region Sales Office: [email protected] Midwest Region Sales Office: [email protected] West Region Sales Office: [email protected] Latin America Sales Office: [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China: [email protected] Shanghai, China: [email protected] Pune, India: [email protected] Kaohsiung, Taiwan: [email protected] Yokohama, Japan: [email protected] Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: [email protected] Germany: [email protected] France: [email protected] www.carlingtech.com REV_02_2016