EnCORE Framing

EnCORE™ Thermal Framing System
A Proven Performer
Recognized for
Economical Installation
Forever 21 – Hawaii
Architect: J.T. Nakaoka Associates Architects, Los Angeles, California, USA
Glazing Contractor: Reflections Glass, Waipahu, Hawaii, USA
Photography: © Aqua Photo
Taking center stage in Kawneer’s lineup, the EnCORE™ Thermal
Framing System is a two-piece, face-and-gutter system that offers
thermal economy, a Structural Silicone Glazing (SSG) option and
numerous design choices. Engineered for easy installation and
lower costs, features include the unique QuickSeal™ self-sealing
system, a broad selection of system depths and a 1-3/4" (44.5
mm) minimal sightline. EnCORE™ Thermal Framing readily adapts
to remodel projects and new construction, whether traditional or
modern architecture.
Economy
EnCORE™ Thermal Framing System’s QuickSeal™ dryglazed self-sealing framing system is the first to eliminate
joint sealant at horizontal joints, making it more cost effective.
The vertical gasket runs through, and when “pinched” by
the head, sill and intermediate horizontals, a watertight seal is
created, eliminating the need for sealant.
By using the same extrusions for horizontal and vertical mullions,
metal utilization is maximized. In addition, the tongue on the
extrusions eliminates the need for a secondary, continuous water
deflector, thus economizing on installation costs and time.
EnCORE™ Thermal Framing also requires no setting block chair at
intermediate horizontals. And at the sill, the system utilizes a simple
setting block chair that fits snugly within the glazing pocket and
requires no fastening. The system accepts standard 1" (25.4 mm) or
1/4" (6.4 mm) infills and can also be adapted to accept other infills in
1/8" (3.2 mm) increments.
The top-loaded glazing gaskets are the same as those used in
the Kawneer flagship Trifab™ Framing Systems, which helps reduce
field labor and minimize inventory requirements.
Providing single-source responsibility, Kawneer entrances, windows,
curtain walls and slope glazing are compatible with EnCORE™
Thermal Framing.
Performance
A specially engineered thermal clip eliminates metal-to-metal contact
by snapping onto the mullion. The cover then snaps onto the clip for
true thermal integrity. In addition, the clip has an extended leg on
one side, which acts as a “w” block and prevents shifting of glass due
to climate changes and building movement.
Forever 21 – Hawaii
Architect: J.T. Nakaoka Associates Architects, Los Angeles, California, USA
Glazing Contractor: Reflections Glass, Waipahu, Hawaii, USA
Engineered to meet or exceed certified performance requirements
for air and water infiltration, EnCORE™ Thermal Framing has been
fully tested according to ASTM E283 and ASTM E331. Thermal
testing was completed in accordance with AAMA 1503.
EnCORE™ Thermal Framing also offers architects and building
owners the ability to determine project-specific U-factors by referring
to thermal tables in our architectural manual. Unique to Kawneer,
these tables enable U-factor calculations for each project by utilizing
the total glass percentage and the project’s center of glass (COG)
U-factor.
For the Finishing Touch
Aesthetics
For additional freedom of expression, EnCORE™ Thermal Framing
offers front or center glazing options. A Structural Silicone Glazing
(SSG) option is also available. And to provide greater design
flexibility, the face-and-gutter system offers system depths of 3-9/16"
(90.5 mm), 4-1/2" (114.3 mm) or 6" (152.4 mm) front glazed and 4-1/2"
(114.3 mm) center glazed.
The 1-3/4" (44.5 mm) minimal sightline provides consistent design
aesthetics, while a 1-1/4" (31.75 mm) perimeter sightline is also
available. Since the exterior face and interior mullions are separate
pieces, two-color design considerations are easily realized.
Kawneer Company, Inc.
Technology Park / Atlanta
555 Guthridge Court
Norcross, GA 30092
Another key feature of EnCORE™ Thermal Framing’s separate
components is that they are easily adapted to curved applications.
The framing is available in three fabrication methods: screw spline,
shear block or Type B, which is a combination of both.
Permanodic™ anodized finishes are available in Class I and Class II in
seven different color choices.
Painted finishes, including fluoropolymer, that meet or exceed
AAMA 2605 are offered in many standard choices and an unlimited
number of specially designed colors.
Solvent-free powder coatings add the “green” element with high
performance, durability and scratch resistance that meet the
standards of AAMA 2604.
kawneer.com
kawneergreen.com
770 . 449 . 5555
© Kawneer Company, Inc. 2013 LITHO IN U.S.A. Form No. 13-2185-1
EnCORE™, QuickSeal™, Trifab™, VersaGlaze™, GLASSvent™ and Permanodic™ are trademarks of Kawneer Company, Inc. and Alcoa Inc.
EnCORETM
FEBRUARY, 2014
EC 97911-055
FEATURES
FEATURES
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
•
•
•
•
•
•
•
•
•
•
Economical
1-3/4" sight line with a 3-9/16", 4-1/2" or 6" depth
Front or Center (4-1/2") glass applications
Outside glazed
Screw Spline, Shear Block or Type-B fabrication
SSG option
Infill options up to 1-1/8"
Thermal break via. Polymer glazing clip
PermanodicTM anodized finishes in seven standard choices
Painted finishes in standard and custom choices
OPTIONAL FEATURES
PRODUCT APPLICATIONS
•
•
•
•
•
Storefront, Ribbon Window or Punched Openings
Low to mid-rise
Single-span
Curved frames
Integrated entrance framing allowing Kawneer entrances or other specialty
entrances to be included
• Kawneer windows or GLASSventTM for storefront are easily incorporated
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
• Two color capability
• 1-1/4" perimeter sight line
• Project specific U-factors (See Thermal Charts)
For specific product applications,
consult your Kawneer Representative
kawneer.com
ADMC080
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EnCORETM
BLANK PAGE
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
FEBRUARY, 2014
EC 97911-055
EnCORETM
FEBRUARY, 2014
INDEX
PICTORIAL VIEWS........................................................................... 5-8
BASIC FRAMING DETAILS............................................................ 9-20
MISCELLANEOUS FRAMING...................................................... 21,22
GLAZING CHART.............................................................................. 22
GLASSventTM FOR STOREFRONT.............................................. 23,24
VENTS................................................................................................ 25
ENTRANCE FRAMING................................................................. 26-32
WINDLOAD/DEADLOAD CHARTS.............................................. 33-41
DEADLOAD CHARTS.................................................................. 42-46
THERMAL CHARTS..................................................................... 47-51
GLAZING CLIP CHART..................................................................... 52
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference.
Numbers in parentheses ( ) are millimeters unless otherwise noted.
The following metric (SI) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-055
3
Kawneer reserves the right to change configurations without prior notice when deemed necessary
for product improvement.
kawneer.com
ADMC080
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EnCORETM
BLANK PAGE
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
FEBRUARY, 2014
EC 97911-055
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FEBRUARY, 2014
kawneer.com
EnCORETM
EC 97911-055
PICTORIAL VIEW (SCREW SPLINE ASSEMBLY)
SPLIT MULLION
FLAT FILLER
HEAD
SPLINE SCREWS
WATER DEFLECTOR
INTERMEDIATE
HORIZONTAL
SPLINE SCREWS
SETTING BLOCK CHAIR
GLAZING CLIP
SILL
COVER
SILL
FLASHING
ADMC080
5
(Standard Mullion Show SSG Optional)
HEAD
SHEAR BLOCK
SETTING BLOCK CHAIR
GLAZING CLIP
SILL
COVER
SILL
FLASHING
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
PICTORIAL VIEW (SHEAR BLOCK ASSEMBLY)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EnCORETM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6
FEBRUARY, 2014
EC 97911-055
MULLION
WATER DEFLECTOR
INTERMEDIATE
HORIZONTAL
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FEBRUARY, 2014
kawneer.com
EnCORETM
EC 97911-055
PICTORIAL VIEW (TYPE-B ASSEMBLY)
MULLION
HEAD
GLAZING CLIP
SHEAR BLOCK
WATER DEFLECTOR
INTERMEDIATE
HORIZONTAL
SPLINE
SCREWS
SETTING BLOCK CHAIR
GLAZING CLIP
SILL
5/16" Dia. WEEP HOLE
COVER
ADMC080
7
PICTORIAL VIEW (TYPE-B SSG ASSEMBLY)
SSG
MULLION
HEAD
SHEAR BLOCK
SPLINE
SCREWS
ADMC080
COVER
SETTING BLOCK CHAIR
GLAZING CLIP
SILL
kawneer.com
© Kawneer Company, Inc., 2014
DETAILS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EnCORETM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
8
FEBRUARY, 2014
EC 97911-055
GLAZING CLIP
INTERMEDIATE
HORIZONTAL
175155
4
JAMB
kawneer.com
175003
2
2
HORIZONTAL
175021
175505
3
SILL
1-3/4"
(44.5)
TYP.
MULLION
175155
175155
175155
5
4
JAMB
5
SPLIT
MULLION
ADMC080
175007
175023
175171
ADAPTER
HORIZONTAL
175155
1
HEAD
175007
175155
175021
3-9/16"
(90.5) TYP.
175002
FLASHING
175155
175155
175155
175155
1/4" INFILL
5/8"
(15.9)
175155
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-055
175005
175001
175027
175025
175021
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
FEBRUARY, 2014
EnCORETM
9
3-9/16" SYSTEM (SCREW SPLINE)
SCALE 3" = 1'-0"
ELEVATION IS NUMBER KEYED TO DETAILS
1" INFILL
175001
1
HEAD
175003
175171
ADAPTER
2A
HORIZONTAL
W/ 1/4" ADAPTER
175001
175002
FLASHING
175504
3
SILL
175005
175155
5A
SPLIT MULLION
W/ 1/4" ADAPTER
175155
175155
4
JAMB
5
MULLION
5/8"
(15.9)
3
SILL
ADMC080
175051
175073
175071
175504
1-3/4"
(44.5)
TYP.
175050
1
HEAD
1
HEAD w/ caulk leg
175053
175171
ADAPTER
2
HORIZONTAL
2A
HORIZONTAL
W/ 1/4" ADAPTER
175051
175052
FLASHING
3
SILL
1-3/4"
(44.5)
TYP.
175055
175155
175155
4
JAMB
5
SPLIT
MULLION
175155
5A
SPLIT MULLION
W/ 1/4" ADAPTER
kawneer.com
© Kawneer Company, Inc., 2014
1" INFILL
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
ELEVATION IS NUMBER KEYED TO DETAILS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175155
175155
4-1/2" SYSTEM (SCREW SPLINE)
175057
2
HORIZONTAL
175155
1
HEAD
175057
175155
175155
EnCORETM
175171
ADAPTER
4-1/2"
(114.3) TYP.
175052
FLASHING
175155
175155
175071
175055
175051
175155
1/4" INFILL
5/8"
(15.9)
4-1/2"
(114.3) TYP.
175077
175505
175075
175071
10
FEBRUARY, 2014
EC 97911-055
SCALE 3" = 1'-0"
175053
kawneer.com
175003
2
HORIZONTAL
2
HORIZONTAL
175021
3
SILL
ADMC080
175007
175023
175171
ADAPTER
1
HEAD
175156
175156
175021
175007
175002
FLASHING
175156
175156
175156
175156
1/4" INFILL
175005
175156
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-055
175001
175027
175505
175025
175021
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
FEBRUARY, 2014
EnCORETM
11
4-1/2" SYSTEM - CENTER GLAZED (SCREW SPLINE)
SCALE 3" = 1'-0"
ELEVATION IS NUMBER KEYED TO DETAILS
1" INFILL
175001
1
HEAD
175003
175171
ADAPTER
2A
HORIZONTAL
W/ 1/4" ADAPTER
175001
175002
FLASHING
175504
3
SILL
175005
175156
175156
175156
175156
175156
4
JAMB
5
MULLION
4
JAMB
5
SPLIT
MULLION
5A
SPLIT MULLION
W/ 1/4" ADAPTER
175155
175155
4
JAMB
5
MULLION
ADMC080
1" INFILL
175101
175121
1-3/4"
(44.5)
TYP.
3
SILL
175100
1
HEAD
1
HEAD w/ caulk leg
175103
2
HORIZONTAL
2A
HORIZONTAL
W/ 1/4" ADAPTER
175101
175102
FLASHING
175504
1-3/4"
(44.5)
TYP.
175105
175155
175155
4
JAMB
5
SPLIT
MULLION
175155
5A
SPLIT MULLION
W/ 1/4" ADAPTER
kawneer.com
© Kawneer Company, Inc., 2014
ELEVATION IS NUMBER KEYED TO DETAILS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
6" SYSTEM (SCREW SPLINE)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175123
175107
175155
175155
175155
EnCORETM
175171
ADAPTER
2
HORIZONTAL
175155
175121
175107
175505
6"
(152.4) TYP.
175155
1
HEAD
175105
175101
175102
FLASHING
175155
175155
1/4" INFILL
5/8"
(15.9)
175127
6"
(152.4) TYP.
3
SILL
5/8"
(15.9)
175125
175121
175155
12
FEBRUARY, 2014
EC 97911-055
SCALE 3" = 1'-0"
175103
175171
ADAPTER
EnCORETM
FEBRUARY, 2014
EC 97911-055
3-9/16" SYSTEM (SHEAR BLOCK)
NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH.
SCALE 3" = 1'-0"
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
13
ELEVATION IS NUMBER KEYED TO DETAILS
1/4" INFILL
1" INFILL
175155
175155
175155
175003
175021
175001
1
HEAD
1
HEAD
2
HORIZONTAL
175023
175155
175155
175003
175002
FLASHING
175504
2
HORIZONTAL
175171
ADAPTER
3
SILL
2A
HORIZONTAL
W/ 1/4" ADAPTER
175002
FLASHING
175171
ADAPTER
175001
175155
175155
175155
4
JAMB
5
MULLION
5A
MULLION
W/ 1/4" ADAPTER
175008
175008
175155
175155
4
JAMB
5
MULLION
kawneer.com
6
SSG
MULLION
6
SSG
mullion
6a
w/ 1/4" adapter
inside seal
ADMC080
175008
175171
ADAPTER
175028
175171
ADAPTER
175027
3
SILL
175023
175505
175003
175003
175155
175021
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175155
175001
6A
W/ 1/4" ADAPTER
outside seal
EnCORETM
FEBRUARY, 2014
4-1/2" SYSTEM (SHEAR BLOCK)
SCALE 3" = 1'-0"
EC 97911-055
ELEVATION IS NUMBER KEYED TO DETAILS
1/4" INFILL
1" INFILL
175155
175155
175155
175053
175071
175051
1
HEAD
1
HEAD
175073
2
HORIZONTAL
175171
ADAPTER
3
SILL
2
HORIZONTAL
2A
HORIZONTAL
W/ 1/4" ADAPTER
175071
175171
ADAPTER
175053
175051
175505
3
SILL
175155
175155
4
JAMB
5
MULLION
5A
MULLION
W/ 1/4" ADAPTER
175058
175058
175058
6
ssg
mullion
6a
w/ 1/4" adapter
inside seal
6A
W/ 1/4" ADAPTER
outside seal
175171
ADAPTER
175073
175071
175078
175155
175155
4
JAMB
5
MULLION
6
SSG
MULLION
ADMC080
175171
ADAPTER
175155
175053
175052
FLASHING
kawneer.com
© Kawneer Company, Inc., 2014
175052
FLASHING
175155
175053
175155
175155
175051
175504
175155
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
14
EnCORETM
FEBRUARY, 2014
EC 97911-055
4-1/2" SYSTEM - CENTER GLAZED (SHEAR BLOCK)
SCALE 3" = 1'-0"
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
15
NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH.
ELEVATION IS NUMBER KEYED TO DETAILS
1/4" INFILL
1" INFILL
175156
175156
175156
175003
175001
175021
1
HEAD
1
HEAD
2
HORIZONTAL
175023
175156
175156
175156
175002
FLASHING
175171
ADAPTER
175504
2
HORIZONTAL
3
SILL
2A
HORIZONTAL
W/ 1/4" ADAPTER
175003
175156
175156
175156
4
JAMB
5
MULLION
5A
MULLION
W/ 1/4" ADAPTER
175008
175008
175008
6
SSG
MULLION
6A
W/ 1/4" ADAPTER
INSIDE SEAL
6A
W/ 1/4" ADAPTER
OUTSIDE SEAL
175171
ADAPTER
175023
175028
175021
175171
ADAPTER
3
SILL
175156
175156
4
JAMB
5
MULLION
kawneer.com
6
SSG
MULLION
ADMC080
175171
ADAPTER
175505
175001
175002
FLASHING
175003
175152
175021
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175003
175001
EnCORETM
FEBRUARY, 2014
6" SYSTEM (SHEAR BLOCK)
EC 97911-055
ELEVATION IS NUMBER KEYED TO DETAILS
1/4" INFILL
1" INFILL
175155
175101
175121
1
HEAD
1
HEAD
2
HORIZONTAL
175101
175155
175155
175103
175155
175123
175102
FLASHING
175171
ADAPTER
175504
2
HORIZONTAL
175103
175101
175103
175121
175155
2A
HORIZONTAL
W/ 1/4" ADAPTER
3
SILL
175171
ADAPTER
175102
FLASHING
175505
3
SILL
175155
175155
4
JAMB
5
MULLION
5A
MULLION
W/ 1/4" ADAPTER
175108
175108
175108
175155
175155
4
JAMB
5
MULLION
6
SSG
MULLION
6
SSG
MULLION
6A
W/ 1/4" ADAPTER
INSIDE SEAL
6A
W/ 1/4" ADAPTER
OUTSIDE SEAL
ADMC080
175171
ADAPTER
175155
175171
ADAPTER
175123
175121
175128
kawneer.com
© Kawneer Company, Inc., 2014
175155
175155
175103
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH.
SCALE 3" = 1'-0"
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
16
175129
kawneer.com
175029
4-1/2" SYSTEM
center glazed
175155
ADMC080
175009
175156
175156
175079
4-1/2" SYSTEM
175059
175155
175155
175029
3-9/16" SYSTEM
175009
175155
175155
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-055
1/4" INFILL
175029
175155
175079
175155
175029
175156
175129
6" SYSTEM
175109
175155
175155
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
FEBRUARY, 2014
EnCORETM
175155
17
90° OUTSIDE CORNERS
SCALE 3" = 1'-0"
1" INFILL
175009
175155
175059
175155
175009
175156
175109
175155
175155
175156
175156
175059
175155
175155
175009
175029
1/4" INFILL
175155
3-9/16" SYSTEM
175155
175029
175009
4-1/2" SYSTEM
175155
175155
175079
175156
175029
175155
175129
ADMC080
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
175155
175155
175079
90° INSIDE CORNERS
4-1/2" SYSTEM
center glazed
175156
175009
6" SYSTEM
175155
175109
kawneer.com
© Kawneer Company, Inc., 2014
175009
175029
EnCORETM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175109
175129
18
FEBRUARY, 2014
EC 97911-055
SCALE 3" = 1'-0"
1" INFILL
175059
55
51
17
55
51
17
6" SYSTEM
175155
ADMC080
175109
09
51
17
29
51
17
175129
4-1/2" SYSTEM
center glazed
56
51
17
56
51
17
175009
175029
09
50
17
29
50
17
© Kawneer Company, Inc., 2014
4-1/2" SYSTEM
55
51
17
55
51
17
175059
175079
59
50
17
3-9/16" SYSTEM
55
51
17
55
51
17
175009
175029
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
09
50
79
50
17
kawneer.com
17
29
50
17
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
FEBRUARY, 2014
EnCORETM
EC 97911-055
135° OUTSIDE CORNERS
SCALE 3" = 1'-0"
1/4" INFILL
1" INFILL
175155
175155
175155
175155
175156
175156
175155
19
29
50
17
175155
55
51
17
5
5
51
17
ADMC080
09
50
4-1/2" SYSTEM
center glazed
17
175009
09
3-9/16" SYSTEM
50
17
175009
1/4" INFILL
175155
4-1/2" SYSTEM
175155
175155
175155
6" SYSTEM
175155
kawneer.com
© Kawneer Company, Inc., 2014
175059
29
50
17
175029
135° INSIDE CORNERS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
59
50
17
79
50
17
175079
EnCORETM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
09
51
17
175109
55
51
17
55
51
17
17
51
29
55
51
17
55
51
175029
4-1/2"
(114.3)
55
51
5/8"
(15.9)
175155
17
55
51
17
1-3/4"
(44.5)
17
175129
20
FEBRUARY, 2014
EC 97911-055
SCALE 3" = 1'-0"
1" INFILL
175155
EnCORETM
FEBRUARY, 2014
EC 97911-055
MISCELLANEOUS FRAMING
SCALE 3" = 1'-0"
1-1/4" narrow perimeter
1-1/4" narrow perimeter
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
screw spline system
with 1/4" infill
screw spline system
with 1" infill
175011
175031
175157
3-9/16" SYSTEM
175012
175507
175061
175081
175157
4-1/2" SYSTEM
175062
175157
175507
175062
175506
175031
175158
4-1/2" SYSTEM
center glazed
175012
175011
175158
175507
175012
175506
175131
175157
175111
6" SYSTEM
175112
175157
175507
175112
175506
heavy mullions
279505
279500
279500
279502
3-9/16" non-thermal
175004
(IN LIEU OF 175003)
175054
(IN LIEU OF 175053)
3-9/16" thermal
279506
279500
279500
279503
4-1/2" non-thermal
175104
(IN LIEU OF 175103)
279507
279501
6" non-thermal
175006
(IN LIEU OF 175005)
4-1/2" thermal
279504
279501
© Kawneer Company, Inc., 2014
175012
175506
head receptors
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175157
175056
(IN LIEU OF 175055)
6" thermal
175106
(IN LIEU OF 175105)
NOTE:
HEAVY MULLIONS CAN BE USED WITH
STANDARD FACE COVERS 175155 & 175156
kawneer.com
ADMC080
21
22
EnCORETM
FEBRUARY, 2014
MISCELLANEOUS FRAMING / GLAZING CHART
EC 97911-055
SCALE 3" = 1'-0"
HORIZONTAL / CROSSRAIL ASSEMBLY
(SCREW SPLINE SYSTEM)
175029
175009
EnCORETM GLAZING CHART
1/2" INFILL ADAPTER
(SHOWN WITH 3-9/16" DEEP SYSTEM)
INFILL
THICKNESS
ADAPTER
for 1" Infill Pocket
WEATHERING
(Both Sides)
1/8"
175171
027077 Heavy
1/4"
175171
027074 Standard
3/8"
175171
027076 Light
1/2"
175173
027074 Standard
5/8"
175173
027076 Light
3/4"
175175
027074 Standard
7/8"
–
027077 Heavy
1"
–
027074 Standard
1-1/8"
–
027076 Light
175173
ADAPTER
HEAD
175173
ADAPTER
175173
ADAPTER
175173
ADAPTER
HORIZONTAL
MULLION
175109
175059
175155
175156
175129
175079
175155
BRAKE
METAL
NOTE: For infill thicknesses in 1/16" increments or oversize
glass, use a combination of the Std. (027074) with either
the Light (27076) or the Heavy (027077) gaskets.
SSG GLAZING CHART
INFILL
THICKNESS
SSG
ADAPTER
HORIZONTAL
WEATHERING
SSG
WEATHERING
1/4"
175172
027074 Std.
175302
1/2"
175173
027074 Std.
175302
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
175059
175155
175156
175129
175079
175155
175156
175156
BRAKE
METAL
175109
175009
175029
JAMB
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1" INFILL
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1/4" INFILL
EnCORETM
FEBRUARY, 2014
EC 97911-055
23
GLASSventTM FOR STOREFRONT
SCALE 3" = 1'-0"
PROJECT-OUT
1
1
5
175051
175053
6
2
3
3
452132
452132
7
8
4
ELEVATION IS NUMBER KEYED TO DETAILS
452132
452132
2
4
175053
175051
452132
175155
© Kawneer Company, Inc., 2014
5
452132
175155
175051
OUTSWING CASEMENT
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175155
175155
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
OUTSWING CASEMENT
PROJECT-OUT
175053
175053
175155
175155
6
175053
452132
7
NOTE: Bronze spacer is recommended when 1" insulating glass is used.
MAXIMUM / MINIMUM SIZES (1" INFILL)
PROJECT-OUT
MAXIMUM 60" x 36"
MINIMUM 14" x 14"
OUTSWING CASEMENT MAXIMUM 36" x 60"
MINIMUM 14" x 14"
kawneer.com
175052
ADMC080
452132
175155
8
EnCORETM
GLASSvent
TM
FEBRUARY, 2014
FOR STOREFRONT
EC 97911-055
PROJECT - OUT
OUTSWING CASEMENT
Stainless steel 4-bar hinge
STANDARD
STANDARD
Cast white bronze cam lock
STANDARD
STANDARD
Cast white bronze cam lock with pole ring
OPTIONAL
OPTIONAL
Cast white bronze custodial lock
with removable handle
OPTIONAL
OPTIONAL
Cast white bronze concealed lock
with removable hex key
OPTIONAL
OPTIONAL
Cast white bronze pole/pull ring
OPTIONAL
Pivot-shoe roto-operator
OPTIONAL
Multi-point lock with cast white
bronze locking handle
OPTIONAL
Insect screen
CAM LOCK
OPTIONAL
CAM LOCK
WITH POLE RING
PULL RING
REMOVABLE
HANDLE
PIVOT-SHOE
ROTO-OPERATOR
CONCEALED LOCK
INSECT SCREEN
WITH STANDARD WICKET
ADMC080
OPTIONAL
ACCESS
CONTROL
LOCK
STAINLESS STEEL
4 BAR HINGES
INSECT SCREEN
WITH FULL WICKET
kawneer.com
© Kawneer Company, Inc., 2014
DESCRIPTION
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
GLASSventTM FOR STOREFRONT HARDWARE SELECTION GUIDE
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
24
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FEBRUARY, 2014
1
2
kawneer.com
EnCORETM
EC 97911-055
VENTS
SCALE 3" = 1'-0"
175053
175155
8225TL IsoLockTM WINDOW SHOWN
175155
NOTE: Other vent types can be accommodated.
Consult your Kawneer Representative for other options.
175174
VENT ADAPTER
1
3
175174
VENT ADAPTER
175053
175174
VENT ADAPTER
175174
VENT ADAPTER
3
ADMC080
4
2
ELEVATION IS NUMBER KEYED TO DETAILS
175155
175053
175053
175155
4
25
EnCORETM
FEBRUARY, 2014
4-1/2" ENTRANCE FRAMING (FRONT GLAZED)
SCALE 3" = 1'-0"
EC 97911-055
EnCORETM FRAMING INCORPORATING KAWNEER "190" DOORS.
175155
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
NOTE: Other types of Kawneer doors may be used with this framing.
See the Entrance Section for additional information.
175051
1
TRANSOM HEAD
ELEVATION IS NUMBER KEYED TO DETAILS
175251
STOPS
175251
STOPS
175251
STOPS
175206
175221
175653
041045
2
OFFSET PIVOT/
BUTT HUNG
TRANSOM BAR
2
S/A OFFSET ARM
OFFSET PIVOT/
BUTT HUNG
TRANSOM BAR
2
C.O.C.
CENTER PIVOT
TRANSOM BAR
175206
175221
175653
450500
TRAY
041045
3
OFFSET PIVOT/
BUTT HUNG
HEADER
3
S/A OFFSET ARM
OFFSET PIVOT/
BUTT HUNG
HEADER
ADMC080
3
C.O.C.
CENTER PIVOT
HEADER
kawneer.com
© Kawneer Company, Inc., 2014
450500
TRAY
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
26
EnCORETM
FEBRUARY, 2014
EC 97911-055
27
4-1/2" ENTRANCE FRAMING (FRONT GLAZED)
SCALE 3" = 1'-0"
Transom area for both double or single acting doors with glass surround. Jambs above transom area are routed out to
accept pocket insert 175253.
175253
POCKET
INSERT
175155
4
DOOR JAMB
AT TRANSOM
175642
175058
175058
175273
175273
175053
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
175232
or
175242
4
DOOR JAMB
AT TRANSOM
(OPTIONAL)
5
SINGLE ACTING
SSG DOOR JAMB
W/ DOOR ADAPTER
5
DOUBLE ACTING
SSG DOOR JAMB
W/ DOOR ADAPTER
175053
175232
175053
5
SINGLE ACTING
DOOR JAMB
5
DOUBLE ACTING
DOOR JAMB
175642
175232
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175233
175643
5
SINGLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
5
DOUBLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
175051
175051
HOLE
PLUG
175164
175164
HOLE
PLUG
175643
6
SINGLE ACTING
DOOR JAMB
kawneer.com
6
DOUBLE ACTING
DOOR JAMB
6
SINGLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
ADMC080
175233
6
DOUBLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
EnCORETM
FEBRUARY, 2014
4-1/2" ENTRANCE FRAMING (CENTER GLAZED)
SCALE 3" = 1'-0"
EC 97911-055
EnCORETM FRAMING INCORPORATING KAWNEER "190" DOORS.
175156
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
NOTE: Other types of Kawneer doors may be used with this framing.
See the Entrance Section for additional information.
175001
1
TRANSOM HEAD
ELEVATION IS NUMBER KEYED TO DETAILS
175251
STOP
175251
STOP
175252
STOP
175252
STOP
175251
STOP
175206
175221
175653
450500
TRAY
041045
2
OFFSET PIVOT/
BUTT HUNG
TRANSOM BAR
2
S/A OFFSET ARM
OFFSET PIVOT/
BUTT HUNG
TRANSOM BAR
2
C.O.C.
CENTER PIVOT
TRANSOM BAR
175206
175221
175653
450500
TRAY
041045
3
OFFSET PIVOT/
BUTT HUNG
HEADER
3
S/A OFFSET ARM
OFFSET PIVOT/
BUTT HUNG
HEADER
ADMC080
3
C.O.C.
CENTER PIVOT
HEADER
kawneer.com
© Kawneer Company, Inc., 2014
175252
STOP
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
28
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FEBRUARY, 2014
kawneer.com
EnCORETM
EC 97911-055
4-1/2" ENTRANCE FRAMING (CENTER GLAZED)
SCALE 3" = 1'-0"
Transom area for both double or single acting doors with glass surround. Jambs above transom area are routed out to
accept pocket insert 175253.
175231
or
175641
175253
POCKET
INSERT
4
DOOR JAMB
AT TRANSOM
175641
175231
5
SINGLE ACTING
DOOR JAMB
5
DOUBLE ACTING
DOOR JAMB
175641
175231
6
SINGLE ACTING
DOOR JAMB
6
DOUBLE ACTING
DOOR JAMB
ADMC080
29
EnCORETM
30
FEBRUARY, 2014
6" ENTRANCE FRAMING (FRONT GLAZED)
SCALE 3" = 1'-0"
EC 97911-055
EnCORETM FRAMING INCORPORATING KAWNEER "190" DOORS.
175155
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
NOTE: Other types of Kawneer doors may be used with this framing.
See the Entrance Section for additional information.
175101
1
TRANSOM HEAD
ELEVATION IS NUMBER KEYED TO DETAILS
175251
STOPS
175251
STOPS
175251
STOPS
175207
450500
TRAY
041045
2
OFFSET PIVOT/
BUTT HUNG
TRANSOM BAR
2
S/A OFFSET ARM
OFFSET PIVOT/
BUTT HUNG
TRANSOM BAR
2
C.O.C.
CENTER PIVOT
TRANSOM BAR
175207
175222
175654
450500
TRAY
041045
3
OFFSET PIVOT/
BUTT HUNG
HEADER
3
S/A OFFSET ARM
OFFSET PIVOT/
BUTT HUNG
HEADER
ADMC080
3
C.O.C.
CENTER PIVOT
HEADER
kawneer.com
© Kawneer Company, Inc., 2014
175222
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175654
EnCORETM
FEBRUARY, 2014
EC 97911-055
6" ENTRANCE FRAMING (FRONT GLAZED)
SCALE 3" = 1'-0"
175108
175273
175273
175103
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
175155
4
DOOR JAMB
AT TRANSOM
5
SINGLE ACTING
SSG DOOR JAMB
W/ DOOR ADAPTER
5
DOUBLE ACTING
SSG DOOR JAMB
W/ DOOR ADAPTER
175103
175103
175233
175643
5
SINGLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
5
DOUBLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
175101
175101
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175108
HOLE
PLUG
175164
175164
HOLE
PLUG
175643
6
SINGLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
kawneer.com
ADMC080
175233
6
DOUBLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
31
EnCORETM
FEBRUARY, 2014
ENTRANCE FRAMING OPTIONS
SCALE 3" = 1'-0"
EC 97911-055
175640
060148
SINGLE ACTING
DOOR JAMB
DOUBLE ACTING
DOOR JAMB
175058
175053
175053
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
COMMON DOOR JAMBS
HOLE
PLUG
175274
175234
SINGLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
DOUBLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
SINGLE ACTING
SSG DOOR JAMB
W/ DOOR ADAPTER
175103
175103
175108
HOLE
PLUG
175644
175234
SINGLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
DOUBLE ACTING
DOOR JAMB
W/ DOOR ADAPTER
ADMC080
HOLE
PLUG
175274
SINGLE ACTING
SSG DOOR JAMB
W/ DOOR ADAPTER
kawneer.com
© Kawneer Company, Inc., 2014
HOLE
PLUG
175644
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
32
EnCORETM
FEBRUARY, 2014
EC 97911-055
33
WINDLOAD CHARTS
WITH HORIZONTALS
1
1.5
(720 Pa)
B = 20 PSF
(960 Pa)
WITHOUT HORIZONTALS
WIDTH IN METERS
D = 30 PSF (1440 Pa)
2
.5
E = 40 PSF (1920 Pa)
15
12
7
2
6
A 1.5
B
C
D
1
E
5
4
HEIGHT IN FEET
2.5
8
175003
175007
9
3
4
5
6
7
2.5
8
7
A
2
B
C
D
1.5
E
6
175155
5
175156
175156
4
1
I = 0.564 (23.48 x 10 )
S = 0.326 (5.34 x 103)
2
1
8
.5
1
2
6
7
8
WITHOUT HORIZONTALS
WIDTH IN METERS
2
.5
175007
175006
14
4
13
12
9
2.5
8
7
2
6
A
B
1.5
C
D
E
1
5
4
3
2
.5
2
3
4
5
6
WIDTH IN FEET
7
8
4
13
3.5
11
175155
175155
175156
175156
175004
175023
HEIGHT IN FEET
3
2
12
HEIGHT IN METERS
10
1.5
14
3.5
11
1
15
175027
1.5
175025
1
15
HEIGHT IN FEET
5
WITH HORIZONTALS
.5
© Kawneer Company, Inc., 2014
4
WIDTH IN FEET
WIDTH IN METERS
1
3
WIDTH IN FEET
10
3
9
2.5
8
7
A
B
C
D
E 1.5
6
5
4
1
3
175155
175155
2
175156
175156
1
I = 0.792 (32.96 x 104)
S = 0.465 (7.62 x 103)
ADMC080
.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
1
3
9
3
.5
2
10
175155
4
2
3.5
11
175005
3
HEIGHT IN METERS
10
4
13
3.5
11
kawneer.com
2
HEIGHT IN METERS
12
1
1.5
14
4
13
1
1
15
14
3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
A = 15 PSF
C = 25 PSF (1200 Pa)
WIDTH IN METERS
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L\175 up to 13'-6" and L\240 + 1/4" above 13'-6". These curves
are for mullions WITH and WITHOUT HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress
for ALUMINUM (assuming full lateral buckling support) 15,152 psi (104 MPa), FORMED STEEL 30,000 P.S.I. (207 MPa), STEEL BAR 20,000 psi (138
MPa). Charted curves, in all cases, are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10
or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used
to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information.
EnCORETM
FEBRUARY, 2014
WINDLOAD CHARTS
EC 97911-055
WITHOUT HORIZONTALS
2
WIDTH IN METERS
.5
E = 40 PSF (1920 Pa)
15
14
12
9
2.5
8
7
2
6
A
B 1.5
C
D
E
1
5
4
3
2
175008
175028
HEIGHT IN FEET
3
2
3
4
5
6
7
10
3
9
2.5
8
7
A
2
B
C
D
1.5
E
6
5
4
I = 0.654 (27.22 x 104)
S = 0.466 (7.64 x 103)
1
3
2
.5
1
3.5
11
HEIGHT IN METERS
1
8
.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
WIDTH IN FEET
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
.5
1
1.5
WIDTH IN METERS
2
.5
15
1
1.5
2
15
14
14
4
3
9
2.5
8
7
A
2
B
C
1.5
D
E
6
5
4
175155
175155
175156
175156
2
.5
1
2
3
4
5
6
7
10
3
9
6
2.5
A
B
C
D2
E
5
1.5
8
7
4
1
3
3.5
11
HEIGHT IN FEET
10
HEIGHT IN METERS
11
12
175053
3.5
175057
12
4
13
175055
13
HEIGHT IN METERS
HEIGHT IN FEET
10
4
13
3.5
11
HEIGHT IN FEET
2
HEIGHT IN METERS
12
1
1.5
14
4
13
1
1
15
I = 1.277 (53.15 x 104)
S = 0.639 (10.47 x 103)
2
1
8
WIDTH IN FEET
1
3
.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
(960 Pa)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1.5
B = 20 PSF
D = 30 PSF (1440 Pa)
WIDTH IN METERS
1
(720 Pa)
C = 25 PSF (1200 Pa)
WITH HORIZONTALS
.5
A = 15 PSF
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
34
EnCORETM
FEBRUARY, 2014
EC 97911-055
WINDLOAD CHARTS
B = 20 PSF
(960 Pa)
WITHOUT HORIZONTALS
2
WIDTH IN METERS
.5
E = 40 PSF (1920 Pa)
15
12
2.5
8
A
B2
C
D
E 1.5
7
6
5
2
3
4
5
6
7
8
7
A
B
C
6
D
E
2
1
8
.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
WIDTH IN FEET
WITH HORIZONTALS
WITHOUT HORIZONTALS
.5
1
1.5
WIDTH IN METERS
2
.5
15
1
1.5
2
175077
14
12
3
9
2.5
A
B
2
C
D
E 1.5
8
7
6
5
3.5
11
175155
175155
175156
175156
175054
175073
HEIGHT IN FEET
10
HEIGHT IN METERS
3.5
11
4
13
10
3
9
A
2.5
B
C
D
2
E
8
7
6
5
4
1.5
4
1
3
2
2
.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
1
3
175155
175156
175155
175156
I = 1.747 (72.72 x 104)
S = 0.877 (14.37 x 103)
ADMC080
1
.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
12
175075
4
13
175057
175056
15
14
HEIGHT IN FEET
1
1.5
WIDTH IN METERS
© Kawneer Company, Inc., 2014
2.5
2
3
.5
1
3
9
4
I = 1.511 (62.89 x 104)
S = 0.745 (12.21 x 103)
1
2
10
5
4
3
3.5
11
175078
HEIGHT IN FEET
3
9
175058
HEIGHT IN METERS
10
4
13
3.5
11
kawneer.com
2
HEIGHT IN METERS
12
1
1.5
14
4
13
1
1
15
14
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1.5
(720 Pa)
D = 30 PSF (1440 Pa)
WIDTH IN METERS
1
A = 15 PSF
C = 25 PSF (1200 Pa)
WITH HORIZONTALS
.5
35
EnCORETM
FEBRUARY, 2014
WINDLOAD CHARTS
EC 97911-055
WIDTH IN METERS
D = 30 PSF (1440 Pa)
2
15
.5
12
C
D2
7
6
E
5
HEIGHT IN FEET
B 2.5
8
175103
175107
9
3
1
2
8
7
2
6
1.5
.5
4
5
6
7
1.5
2
1
.5
1
2
I = 3.229 (134.40 x 104)
S = 1.094 (17.93 x 103)
175106
WIDTH IN METERS
1
175156
8
WITH HORIZONTALS
.5
175156
2
3
4
5
6
7
8
WIDTH IN FEET
WITHOUT HORIZONTALS
WIDTH IN METERS
175127
3
175155
175125
2
175155
175107
1
1
3
WIDTH IN FEET
.5
15
1
1.5
2
15
14
4
13
12
12
7
E
9
6
5
2
175155
175155
175156
175156
175104
175123
HEIGHT IN FEET
8
A
3
B
C
2.5
D
10
HEIGHT IN METERS
3.5
11
4
13
A
10
B3
C
D
E 2.5
9
8
7
2
6
5
1.5
4
3.5
11
HEIGHT IN METERS
14
HEIGHT IN FEET
9
4
3
1.5
4
1
3
2
1
A3
B
C
2.5
D
E
10
5
1.5
4
1
3.5
11
175105
A
4
12
HEIGHT IN METERS
10
2
13
3.5
11
1.5
14
4
13
1
15
E = 40 PSF (1920 Pa)
14
HEIGHT IN FEET
WITHOUT HORIZONTALS
2
.5
1
2
3
4
5
6
WIDTH IN FEET
7
1
3
1
8
175155
175155
175156
175156
.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
I = 4.325 (180.02 x 104)
S = 1.626 (26.65 x 103)
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
1.5
(960 Pa)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1
B = 20 PSF
C = 25 PSF (1200 Pa)
WIDTH IN METERS
.5
(720 Pa)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
WITH HORIZONTALS
A = 15 PSF
HEIGHT IN METERS
36
EnCORETM
FEBRUARY, 2014
EC 97911-055
WINDLOAD CHARTS
(960 Pa)
WITHOUT HORIZONTALS
WIDTH IN METERS
.5
12
2.5
8
7
C
6
D
5
E
4
2
175108
175128
2
2
3
4
5
6
7
10
9
2.5
8
7
C
6
D
E
4
2
1
8
1
2
1.5
.5
175641
175642
8
1
1.5
2
12
3
9
A
B 2.5
8
C
D
7
E
6
5
2
3.5
11
175231
175232
HEIGHT IN FEET
10
HEIGHT IN METERS
3.5
11
4
13
A3
B
C 2.5
D
E
10
9
8
7
2
6
5
1.5
4
1.5
4
1
3
2
2
.5
1
2
3
4
5
6
WIDTH IN FEET
7
1
3
1
8
I = 2.919 (121.50 x 104)
S = 1.297 (21.25 x 103)
ADMC080
.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
12
HEIGHT IN FEET
7
14
4
13
© Kawneer Company, Inc., 2014
6
15
14
kawneer.com
5
WIDTH IN METERS
2
15
1
4
WITHOUT HORIZONTALS
WIDTH IN METERS
1
3
WIDTH IN FEET
WITH HORIZONTALS
.5
1.5
.5
I = 4.005 (166.70 x 104)
S = 1.533 (25.12 x 103)
WIDTH IN FEET
2
1
3
.5
1
A
B3
5
1.5
1
3
3.5
11
HEIGHT IN FEET
B
9
4
12
HEIGHT IN METERS
A3
10
2
13
3.5
11
1.5
14
4
13
1
15
E = 40 PSF (1920 Pa)
14
1
B = 20 PSF
D = 30 PSF (1440 Pa)
2
15
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1.5
(720 Pa)
C = 25 PSF (1200 Pa)
WIDTH IN METERS
1
A = 15 PSF
HEIGHT IN METERS
WITH HORIZONTALS
.5
37
1
1
2
1
3
1.5
4
5
2
15
14
13
12
11
10
9
3
A
8
7
B
C
D
6
E
5
3
2
WIDTH IN FEET
6
7
2.5
2
(720 Pa)
B = 20 PSF
(960 Pa)
C = 25 PSF (1200 Pa)
D = 30 PSF (1440 Pa)
175640
4
1.5
1
.5
8
I = 2.799 (116.50 x 104)
S = 1.233 (20.21 x 103)
ADMC080
.5
E = 40 PSF (1920 Pa)
15
4
3.5
1
1
2
1
3
1.5
4
5
2
14
13
4
12
11
3.5
10
9
8
7
3
A
B
C 2.5
D
E
6
2
5
4
1.5
3
1
2
.5
6
7
8
WIDTH IN FEET
kawneer.com
© Kawneer Company, Inc., 2014
WINDLOAD CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EnCORETM
HEIGHT IN METERS
WIDTH IN METERS
A = 15 PSF
HEIGHT IN FEET
.5
HEIGHT IN METERS
WITH HORIZONTALS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
HEIGHT IN FEET
38
FEBRUARY, 2014
EC 97911-055
WITHOUT HORIZONTALS
WIDTH IN METERS
EnCORETM
FEBRUARY, 2014
EC 97911-055
WINDLOAD CHARTS
B = 20 PSF
(960 Pa)
2
WITHOUT HORIZONTALS
WIDTH IN METERS
.5
E = 40 PSF (1920 Pa)
15
D
9
8
E
7
2.5
2
6
5
1.5
4
1
3
175155
175156
175155
175156
2
.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
A
12
B
3.5
C
D
3
E
10
9
2.5
8
7
2
6
5
1.5
4
1
3
I = 4.005 (166.70 x 10 )
S = 1.533 (25.12 x 103)
4
WITH 1/2" x 3-1/4" STEEL BAR
I = 1.430 (59.49 x 104)
S = 0.880 (14.43 x 103)
ADMC080
4
13
11
HEIGHT IN FEET
C3
10
175105
11
3.5
HEIGHT IN METERS
B
175107
A
12
HEIGHT IN FEET
2
14
175103
4
13
kawneer.com
1.5
2
1
.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
14
1
1
15
© Kawneer Company, Inc., 2014
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1.5
(720 Pa)
D = 30 PSF (1440 Pa)
WIDTH IN METERS
1
A = 15 PSF
C = 25 PSF (1200 Pa)
WITH HORIZONTALS
.5
39
EnCORETM
40
FEBRUARY, 2014
WINDLOAD CHARTS
EC 97911-055
1.5
WIDTH IN METERS
2
.5
15
1.5
2
14
A
13
A
12
B 3.5
12
B 3.5
9
E
8
7
2.5
2
6
5
175155
175155
175156
175156
4
C
D3
10
9
E
8
7
2.5
2
6
5
1.5
4
1.5
4
1
2
2
.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
1
3
1
175155
175155
175156
175156
.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
I = 4.325 (180.02 x 104)
S = 1.626 (26.65 x 103)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3
1
11
HEIGHT IN FEET
10
175123
C
D3
175104
11
HEIGHT IN METERS
13
4
HEIGHT IN METERS
14
HEIGHT IN FEET
1
15
WITH 1/2" x 3-1/4" STEEL BAR
I = 1.430 (59.49 x 104)
S = 0.880 (14.43 x 103)
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
1
WITHOUT HORIZONTALS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
.5
175127
WIDTH IN METERS
175125
WITH HORIZONTALS
175107
175106
A = 15 PSF (720 Pa)
B = 20 PSF (960 Pa)
C = 25 PSF (1200 Pa)
D = 30 PSF (1440 Pa)
E = 40 PSF (1920 Pa)
EnCORETM
FEBRUARY, 2014
EC 97911-055
41
WINDLOAD CHARTS
A = 15 PSF
(720 Pa)
B = 20 PSF
(960 Pa)
C = 25 PSF (1200 Pa)
E = 40 PSF (1920 Pa)
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
.5
1
1.5
WIDTH IN METERS
2
.5
15
2
14
175128
A
13
A4
12
B 3.5
12
B
3
9
2.5
8
7
C
6
D
5
E
4
1.5
1
3
1
2
I = 4.005 (166.70 x 104)
S = 1.533 (25.12 x 103)
WITH 1/2" x 3-1/4" STEEL BAR
I = 1.430 (59.49 x 104)
S = 0.880 (14.43 x 103)
.5
1
2
3
4
5
6
7
3.5
11
HEIGHT IN FEET
10
HEIGHT IN METERS
13
10
8
2.5
8
7
C
6
D
5
E
4
2
© Kawneer Company, Inc., 2014
1.5
.5
1
2
3
4
5
6
WIDTH IN FEET
ADMC080
2
1
3
1
WIDTH IN FEET
3
9
7
8
HEIGHT IN METERS
175108
2
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1.5
4
11
kawneer.com
1
15
14
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
D = 30 PSF (1440 Pa)
EnCORETM
42
FEBRUARY, 2014
DEADLOAD CHARTS
EC 97911-055
Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member.
The accompanying charts are calculated for 1/4" (6.4) and 1" (25.4) thick glass supported on two setting blocks placed at the loading points shown.
A = 1/4 POINT LOADING
175003
175005
B = 1/6 POINT LOADING
175006
175004
WIDTH IN METERS
1.5
WIDTH IN METERS
1
2
10
3
2.5
8
7
2
6
5
1.5
4
HEIGHT IN FEET
9
1
3
2
C
B
A
1
2
3
4
5
6
7
3
9
2.5
8
7
2
6
5
1.5
4
1
3
2
.5
.5
1
0
8
1
2
WIDTH IN FEET
3
4
WIDTH IN METERS
2
1
1.5
2
13
12
12
3.5
11
10
10
7
2
6
5
1.5
4
HEIGHT IN FEET
2.5
8
HEIGHT IN METERS
3
9
1
3
1
1
2
3
4
5
6
7
3
9
2.5
8
7
2
6
5
1.5
4
1
3
C
B
A .5
2
3.5
11
2
C
.5
B
A
1
0
8
WIDTH IN FEET
HEIGHT IN METERS
13
HEIGHT IN FEET
7
175025
WIDTH IN METERS
1.5
6
WIDTH IN FEET
175023
1
5
C
B
A
8
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
3.5
11
HEIGHT IN METERS
HEIGHT IN FEET
12
3.5
10
0
2
HEIGHT IN METERS
12
11
0
1.5
13
13
1
2
3
4
5
6
7
8
WIDTH IN FEET
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
C = 1/8 POINT LOADING
EnCORETM
FEBRUARY, 2014
EC 97911-055
43
DEADLOAD CHARTS
Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member.
The accompanying charts are calculated for 1/4" (6.4) and 1" (25.4) thick glass supported on two setting blocks placed at the loading points shown.
A = 1/4 POINT LOADING
175053
175055
B = 1/6 POINT LOADING
175056
WIDTH IN METERS
WIDTH IN METERS
1
1.5
2
1
12
10
3
2.5
8
7
2
6
5
1.5
4
HEIGHT IN FEET
9
1
3
2
1
2
3
4
5
6
7
3
9
2.5
8
7
2
6
5
1.5
4
1
3
2
C .5
B
A
1
3.5
11
HEIGHT IN METERS
HEIGHT IN FEET
10
.5
1
0
8
1
2
4
175073
1
1.5
2
7
1
1.5
2
13
12
12
3.5
11
10
10
3
2.5
8
7
2
6
5
1.5
4
C
3
B
A
2
1
1
2
3
4
5
6
7
HEIGHT IN FEET
9
3.5
11
HEIGHT IN METERS
HEIGHT IN FEET
6
WIDTH IN METERS
13
1
3
9
2.5
8
7
2
6
5
1.5
4
1
3
2
.5
C
.5
B
A
1
0
8
WIDTH IN FEET
kawneer.com
5
175075
WIDTH IN METERS
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3
C
B
A
8
WIDTH IN FEET
WIDTH IN FEET
0
2
12
3.5
11
0
1.5
13
HEIGHT IN METERS
13
1
2
3
4
5
6
WIDTH IN FEET
ADMC080
7
8
HEIGHT IN METERS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
C = 1/8 POINT LOADING
175054
EnCORETM
44
FEBRUARY, 2014
DEADLOAD CHARTS
EC 97911-055
Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member.
The accompanying charts are calculated for 1/4" (6.4) and 1" (25.4) thick glass supported on two setting blocks placed at the loading points shown.
A = 1/4 POINT LOADING
175103
175105
B = 1/6 POINT LOADING
WIDTH IN METERS
2
1
13
12
10
2
6
5
1.5
4
HEIGHT IN FEET
7
HEIGHT IN METERS
2.5
8
1
3
2
2
3
4
5
6
7
2.5
8
7
2
6
5
1.5
4
1
2
1
0
8
1
2
WIDTH IN FEET
3
4
WIDTH IN METERS
2
1
13
1.5
2
13
12
12
3.5
11
10
10
3
2.5
8
7
2
6
5
C
4
B
3
1.5
HEIGHT IN FEET
9
1
1
2
3
4
5
6
7
2.5
8
7
2
6
5
1.5
4
1
2
.5
1
3
9
3
A
2
3.5
11
HEIGHT IN METERS
HEIGHT IN FEET
7
175125
WIDTH IN METERS
1.5
6
.5
WIDTH IN FEET
175123
1
5
C
B
A
8
C
B .5
A
1
0
8
WIDTH IN FEET
1
2
3
4
5
6
7
8
WIDTH IN FEET
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
1
3
9
3
C
B .5
A
1
3.5
11
3
9
0
2
12
3.5
10
HEIGHT IN FEET
1.5
13
11
0
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1.5
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175106
WIDTH IN METERS
1
HEIGHT IN METERS
175104
HEIGHT IN METERS
C = 1/8 POINT LOADING
EnCORETM
FEBRUARY, 2014
EC 97911-055
45
DEADLOAD CHARTS
DEADLOADS ON ENTRANCE TRANSOM BARS
Height limitations for transom glass over a doorway are based on a maximum 1/16" (1.6) mid-point deflection of a transom bar supporting glass
bearing on two setting blocks placed at the loading points shown.
B = 1/6 POINT LOADING
175221
WITH 1/4" GLASS
175653
175653
WIDTH IN METERS
1
1.5
WIDTH IN METERS
2
1
12
10
10
2
6
5
1.5
4
HEIGHT IN FEET
7
HEIGHT IN METERS
2.5
8
1
2
1
2
3
4
5
6
7
2
6
5
1.5
4
C
B
A
2
0
8
1
2
3
4
5
6
7
WIDTH IN FEET
175206
175206
WIDTH IN METERS
WIDTH IN METERS
1
1.5
2
1
1
.5
8
WITH 1/4" GLASS
1.5
2
13
12
3.5
10
10
7
2
6
5
1.5
4
HEIGHT IN FEET
2.5
8
HEIGHT IN METERS
3
9
1
3
2
1
2
3
4
5
6
7
3
9
2.5
8
7
2
6
5
1.5
4
1
3
2
.5
1
3.5
11
C
B
A
1
C
B
A
8
0
WIDTH IN FEET
1
2
3
4
5
6
WIDTH IN FEET
ADMC080
7
8
.5
HEIGHT IN METERS
12
11
HEIGHT IN FEET
7
1
13
© Kawneer Company, Inc., 2014
2.5
8
WIDTH IN FEET
WITH 1" GLASS
kawneer.com
3
9
3
C
.5
B
A
1
3.5
11
3
9
0
2
12
3.5
11
0
1.5
13
HEIGHT IN METERS
13
3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
175221
C = 1/8 POINT LOADING
WITH 1" GLASS
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
A = 1/4 POINT LOADING
46
EnCORETM
FEBRUARY, 2014
DEADLOAD CHARTS
EC 97911-055
DEADLOADS ON ENTRANCE TRANSOM BARS
Height limitations for transom glass over a doorway are based on a maximum 1/16" (1.6) mid-point deflection of a transom bar supporting glass
bearing on two setting blocks placed at the loading points shown.
175222
C = 1/8 POINT LOADING
WITH 1/4" GLASS
WITH 1" GLASS
175654
WIDTH IN METERS
WIDTH IN METERS
1
1.5
2
1
12
10
10
2
6
5
1.5
4
HEIGHT IN FEET
7
HEIGHT IN METERS
1
3
2
C
B .5
A
1
1
2
3
4
5
6
7
2.5
8
7
2
6
5
1.5
4
C
3
B
2
A
1
0
8
1
2
3
4
5
6
7
WIDTH IN FEET
WIDTH IN FEET
175207
175207
WIDTH IN METERS
WIDTH IN METERS
WITH 1" GLASS
1
1.5
2
1
13
1
.5
8
WITH 1/4" GLASS
1.5
2
13
12
12
3.5
11
10
10
3
2.5
8
7
2
6
5
1.5
4
HEIGHT IN FEET
9
1
3
2
C
B
A
1
1
2
3
4
5
6
7
3.5
11
HEIGHT IN METERS
HEIGHT IN FEET
3
9
3
9
2.5
8
7
2
6
5
1.5
4
1
3
C
B .5
A
2
.5
1
0
8
WIDTH IN FEET
HEIGHT IN METERS
HEIGHT IN FEET
2.5
8
3.5
11
3
9
0
2
12
3.5
11
0
1.5
13
HEIGHT IN METERS
13
1
2
3
4
5
6
7
8
WIDTH IN FEET
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
175654
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
B = 1/6 POINT LOADING
175222
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
A = 1/4 POINT LOADING
EnCORETM
FEBRUARY, 2014
EC 97911-055
THERMAL CHARTS
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
15'-8" F.W.
2'-0"
D.L.O.
9'-6" F.H.
7'-0"
D.L.O.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
5'-0" D.L.O.
Example Glass U-value =
0.42 Btu/hr·ft2·°F
Total Daylight Opening =
3(5' x 7') + 3(5'x2') = 135 ft2
Total Projected Area =
(Total Daylight Opening + Total Area of Framing System)
= 15'-8" x 9'-6" = 148.83 ft2
Percent of Glass =
(Total Daylight Opening ÷ Total Projected Area)
= (135 ÷ 148.83)100 = 91%
System U-factor vs Percent of Glass Area
0.40
0.30
Percent of Glass
Based on 91% glass and center of glass U-factor of 0.42,
System U-factor is equal to 0.49 Btu/hr·ft2·°F
kawneer.com
ADMC080
70
75
80
85
0.20
90
91%
95
0.50
0.49
E
PL
© Kawneer Company, Inc., 2014
M
A
COG
U-factor
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.60
System U-factor Btu/hr·ft2·°F
0.70
EX
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.80
47
COG
U-factor
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
System U-factor vs Percent of Glass Area
Vision Area / Total Area (%)
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EnCORETM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System U-Factor (Btu/h·ft2·°F)
48
FEBRUARY, 2014
EC 97911-055
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.45
0.40
0.35
kawneer.com
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FEBRUARY, 2014
EnCORETM
EC 97911-055
0.30
0.25
0.20
0.15
0.10
0.05
Charts are generated per AAMA 507.
ADMC080
49
THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
COG
SHGC
0.75
0.70
0.65
0.60
0.55
0.50
0.30
0.25
0.20
0.15
0.10
0.05
Charts are generated per AAMA 507.
THERMAL CHARTS
Vision Ares / Total Area (%)
COG
VT
0.75
0.70
0.65
0.60
0.55
0.50
0.40
0.35
ADMC080
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EnCORETM
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.45
System VT
50
FEBRUARY, 2014
EC 97911-055
System Visible Transmittance (VT) vs Percent of Vision Area
EnCORETM
FEBRUARY, 2014
EC 97911-055
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.61
0.46
0.59
0.44
0.58
0.42
0.56
0.40
0.55
0.38
0.53
0.36
0.51
0.34
0.50
0.32
0.48
0.30
0.46
0.28
0.45
0.26
0.43
0.24
0.42
0.22
0.40
0.20
0.38
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.68
0.75
0.67
0.70
0.64
0.70
0.63
0.65
0.59
0.65
0.58
0.60
0.55
0.60
0.54
0.55
0.50
0.55
0.49
0.50
0.46
0.50
0.45
0.45
0.41
0.45
0.40
0.40
0.37
0.40
0.36
0.35
0.33
0.35
0.31
0.30
0.28
0.30
0.27
0.25
0.24
0.25
0.22
0.20
0.19
0.20
0.18
0.15
0.15
0.15
0.13
0.10
0.10
0.10
0.09
0.05
0.06
0.05
0.04
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
SHGC Matrix 2
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Glass properties are based on center of glass values and are obtained from your glass supplier.
4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of
2000mm wide by 2000mm high (78-3/4" by 78-3/4").
kawneer.com
ADMC080
51
52
EnCORETM
FEBRUARY, 2014
GLAZING CLIP CHART
EC 97911-055
Locate the largest lite of glass on each ELEVATION.
Determine the width and height for the largest glass lite.
Use the smallest of the two dimensions for the MODULE (FT) spacing.
Match that Module (ft) spacing with the required wind load on the chart below.
SAMPLE CALCULATION
Lite "W"
3'-0" x 5'-3-1/2"
3'-0"
12" O.C. for 30 PSF
10" O.C. for 35 PSF
60
55
50
45
A = 6" O.C.
B = 7" O.C.
C = 8" O.C.
D = 9" O.C.
E = 10" O.C.
F = 12" O.C.
40
35
30
15
2
3
4
5
F
6
E7
D
A
B
C
8
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
20
MODULE (FT)
3'-0"
Y
Y
W
Y
Y
X
SAMPLE ELEVATION
ADMC080
kawneer.com
© Kawneer Company, Inc., 2014
25
5'-3-1/2"
WIND LOAD (PSF)
STEP 1:
STEP 2:
STEP 3:
STEP 4:
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Clip spacing of each elevation must be checked to meet wind load requirements.
Glazing clips should be located 3" from each end of member and subsequently spaced per formula below: