pdf

OPTOTRONIC®
OT EASY 80/220-240/24
Four channels and 24V Constant Voltage LED Power Supply with EASY interface
1 Technical Data
Nominal Voltage
220 – 240 Vac
Radio interference:
Input Voltage
Line Current,
nominal
Mains Frequency
Power Factor
198 – 264 Vac
Harmonic content:
400 mA @ 230 Vac
50 / 60 Hz
> 0,95
Non-load proof:
DC voltage operation
No
Max. module wattage
80 W, split to 4 outputs
(80W on one channel
is also possible)
Power factor
PF > 0,95
Max. losses
8W @ 230V
Control signal
Immunity:
Short circuit protection:
Overload protection:
Overheating protection:
Primary:
Digital EASY signal
(via 4pin RJ11
connector)
Wire cross section,
primary:
EN 55015;
(EN 55022 – EASY bus)
EN 61000-3-2
EN 61547
Yes
Autom. shutoff,
reversible
Autom. shutoff,
reversible
Autom. shutoff,
reversible
Terminal screws
2x NYM (2x1,5) or
2x H05VV-F (2x1,5) or
H05VV-F (2x2,5) or
NYM-0 (2x2,5) or
2x H05VV-F (3x1,5)
Max. number of
connectable
components
- 4 EASY IR sensors
- 1 EASY PB CP
- 1 EASY USB Adapter
external switch
same wire type like main
connection
Dimming modus
PWM (300 Hz)
EASY interface
RJ11 connector with 4
wires
Ambient
Temperature
-20°C to +50°C
Secondary:
Wire cross section,
secondary:
Dimming range
0-100 %
Synchronisation
up to 16 units, 1
master and 15 slaves
Max. length of secondary
output wiring:
Safety:
EN 61347
Geometry (l x w x h):
Performance:
EN 62384
Approvals:
RJ -11 connection:
- max. 100m connection cable in total
- max. 50m to push button coupler
- max. 15 slaves connectable
- do not run EASY signal connections together with power
cables or LED wires
OSRAM AG
2012 v0.1
AA371380072
www.osram.com
Costumer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg, Germany
Tel. : (+49) 1803 / 677 - 200 (charges apply)
Fax.: (+49) 1803 / 677 - 202
Terminal screws
2x NYM-0 (2x2,5) or
2x NYM (2x1,5) or
2x H05VV-F (2x1,5) or
2x NYM-0 (2x2,5) or
2x H05VV-F (3x1,5)
10 m
245 mm x 46,2 mm x 43,6
mm
CE
OPTOTRONIC®
OT EASY 80/220-240/24
Four channels and 24V Constant Voltage LED Power Supply with EASY interface
2 Wiring preparation
2.1 Input cables (mains and EASY signal)
2 wires cable 16 mm
PRI 220 – 240 V
0/50/60 Hz
6 mm
Short circuit
for slave device
6 mm
RJ11
RJ11 cable
EASY signal
RJ11 cable
clamp adapter
RJ11
cable
Section view of RJ11
cable with adapter
Rubber adapter
2.2 Section view of input cable clamp
Setup for big wires
Setup for small wires
RJ11 cable
with adapter
RJ11 cable
with adapter
2.3 For the input wires refer to the following table
Input wires diameter
6mm <= D <= 8mm
D
8mm
< D <= 9 mm
9mm
< D <= 9,5 mm
Cable Clamp
OSRAM AG
2012 v0.1
AA371380072
www.osram.com
Costumer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg, Germany
Tel. : (+49) 1803 / 677 - 200 (charges apply)
Fax.: (+49) 1803 / 677 - 202
RJ11 Adapter
OPTOTRONIC®
OT EASY 80/220-240/24
Four channels and 24V Constant Voltage LED Power Supply with EASY interface
3 Wiring diagram
3.1 Controlling LED modules (principle schema)
3.2 System extension (principle schema)
OSRAM AG
2012 v0.1
AA371380072
www.osram.com
Costumer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg, Germany
Tel. : (+49) 1803 / 677 - 200 (charges apply)
Fax.: (+49) 1803 / 677 - 202
OPTOTRONIC®
OT EASY 80/220-240/24
Four channels and 24V Constant Voltage LED Power Supply with EASY interface
3.3 Wiring limitations
4 General Note
•
•
•
Power supplies must be installed by a qualified electrician
Disconnected from mains supply before wiring work
For further information see also EASY components instruction sheet at www.osram.com
OSRAM AG
2012 v0.1
AA371380072
www.osram.com
Costumer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg, Germany
Tel. : (+49) 1803 / 677 - 200 (charges apply)
Fax.: (+49) 1803 / 677 - 202