OPTOTRONIC® OT EASY 80/220-240/24 Four channels and 24V Constant Voltage LED Power Supply with EASY interface 1 Technical Data Nominal Voltage 220 – 240 Vac Radio interference: Input Voltage Line Current, nominal Mains Frequency Power Factor 198 – 264 Vac Harmonic content: 400 mA @ 230 Vac 50 / 60 Hz > 0,95 Non-load proof: DC voltage operation No Max. module wattage 80 W, split to 4 outputs (80W on one channel is also possible) Power factor PF > 0,95 Max. losses 8W @ 230V Control signal Immunity: Short circuit protection: Overload protection: Overheating protection: Primary: Digital EASY signal (via 4pin RJ11 connector) Wire cross section, primary: EN 55015; (EN 55022 – EASY bus) EN 61000-3-2 EN 61547 Yes Autom. shutoff, reversible Autom. shutoff, reversible Autom. shutoff, reversible Terminal screws 2x NYM (2x1,5) or 2x H05VV-F (2x1,5) or H05VV-F (2x2,5) or NYM-0 (2x2,5) or 2x H05VV-F (3x1,5) Max. number of connectable components - 4 EASY IR sensors - 1 EASY PB CP - 1 EASY USB Adapter external switch same wire type like main connection Dimming modus PWM (300 Hz) EASY interface RJ11 connector with 4 wires Ambient Temperature -20°C to +50°C Secondary: Wire cross section, secondary: Dimming range 0-100 % Synchronisation up to 16 units, 1 master and 15 slaves Max. length of secondary output wiring: Safety: EN 61347 Geometry (l x w x h): Performance: EN 62384 Approvals: RJ -11 connection: - max. 100m connection cable in total - max. 50m to push button coupler - max. 15 slaves connectable - do not run EASY signal connections together with power cables or LED wires OSRAM AG 2012 v0.1 AA371380072 www.osram.com Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany Tel. : (+49) 1803 / 677 - 200 (charges apply) Fax.: (+49) 1803 / 677 - 202 Terminal screws 2x NYM-0 (2x2,5) or 2x NYM (2x1,5) or 2x H05VV-F (2x1,5) or 2x NYM-0 (2x2,5) or 2x H05VV-F (3x1,5) 10 m 245 mm x 46,2 mm x 43,6 mm CE OPTOTRONIC® OT EASY 80/220-240/24 Four channels and 24V Constant Voltage LED Power Supply with EASY interface 2 Wiring preparation 2.1 Input cables (mains and EASY signal) 2 wires cable 16 mm PRI 220 – 240 V 0/50/60 Hz 6 mm Short circuit for slave device 6 mm RJ11 RJ11 cable EASY signal RJ11 cable clamp adapter RJ11 cable Section view of RJ11 cable with adapter Rubber adapter 2.2 Section view of input cable clamp Setup for big wires Setup for small wires RJ11 cable with adapter RJ11 cable with adapter 2.3 For the input wires refer to the following table Input wires diameter 6mm <= D <= 8mm D 8mm < D <= 9 mm 9mm < D <= 9,5 mm Cable Clamp OSRAM AG 2012 v0.1 AA371380072 www.osram.com Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany Tel. : (+49) 1803 / 677 - 200 (charges apply) Fax.: (+49) 1803 / 677 - 202 RJ11 Adapter OPTOTRONIC® OT EASY 80/220-240/24 Four channels and 24V Constant Voltage LED Power Supply with EASY interface 3 Wiring diagram 3.1 Controlling LED modules (principle schema) 3.2 System extension (principle schema) OSRAM AG 2012 v0.1 AA371380072 www.osram.com Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany Tel. : (+49) 1803 / 677 - 200 (charges apply) Fax.: (+49) 1803 / 677 - 202 OPTOTRONIC® OT EASY 80/220-240/24 Four channels and 24V Constant Voltage LED Power Supply with EASY interface 3.3 Wiring limitations 4 General Note • • • Power supplies must be installed by a qualified electrician Disconnected from mains supply before wiring work For further information see also EASY components instruction sheet at www.osram.com OSRAM AG 2012 v0.1 AA371380072 www.osram.com Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany Tel. : (+49) 1803 / 677 - 200 (charges apply) Fax.: (+49) 1803 / 677 - 202