10 F006PPA020SB01 M685B10 P1 19

10-F006PPA020SB01-M685B10
preliminary datasheet
Output Inverter Application
flowPIM0+PFC 2nd
600V/20A
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 16 Ω
Rgoff = 16 Ω
IGBT
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
25
Ploss (W)
30
Ploss (W)
FWD
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
Mi*cosfi = 1
25
Mi*cosf i= -1
20
20
15
15
10
10
5
5
Mi*cosfi = -1
Mi*cosfi = 1
0
0
0
5
10
15
20
25
30
35
0
5
10
15
20
25
30
At
Tj =
126
35
Iout (A)
Iout (A)
At
Tj =
°C
Mi*cosφ from -1 to 1 in steps of 0,2
126
°C
Mi*cosφ from -1 to 1 in steps of 0,2
IGBT
Figure 3
Typical average switching loss
as a function of output current
FWD
Figure 4
Typical average switching loss
as a function of output current
Ploss = f(Iout)
20
Ploss = f(Iout)
Ploss (W)
Ploss (W)
6
fsw = 16kHz
5
fsw = 16kHz
15
4
3
10
2
5
1
fsw = 2kHz
fsw = 2kHz
0
0
0
5
10
15
20
At
Tj =
126
DC link =
fsw from
400
V
2 kHz to 16 kHz in steps of factor 2
copyright by Vincotech
25
30 Iout (A)
0
35
5
10
15
20
25
30
35
Iout (A)
°C
1
At
Tj =
126
DC link =
fsw from
400
V
2 kHz to 16 kHz in steps of factor 2
°C
Revision: 1
10-F006PPA020SB01-M685B10
preliminary datasheet
Output Inverter Application
flowPIM0+PFC 2nd
Phase
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
600V/20A
Phase
Figure 6
Typical available 50Hz output current
as a function of switching frequency
Iout = f(Mi*cos φ)
30
Iout = f(fsw)
30
Iout (A)
Iout (A)
Th = 60°C
25
Th = 60°C
25
Th = 100°C
20
20
15
15
Th = 100°C
10
10
5
5
0
0
-1,0
-0,5
0,0
0,5
At
Tj =
126
DC link =
fsw =
Th from
400
V
4
kHz
60 °C to 100 °C in steps of 5 °C
Mi*cos φ
1
1,0
At
Tj =
°C
10
126
fsw (kHz)
100
°C
DC link = 400
V
Mi*cos φ = 0,8
Th from
60 °C to 100 °C in steps of 5 °C
Phase
Figure 7
Typical available 0Hz output current as a function
Ioutpeak = f(fsw)
of switching frequency
-1,0
28,0-30,0
30
Iout (Apeak)
-0,8
Mi*cosfi
Iout (A)
Phase
Figure 8
Typical available 50Hz output current as a function of
Iout = f(fsw, Mi*cos φ)
Mi*cos φ and switching frequency
-0,6
25
Th = 60°C
26,0-28,0
-0,4
24,0-26,0
20
-0,2
22,0-24,0
20,0-22,0
0,0
18,0-20,0
0,2
16,0-18,0
15
10
0,4
14,0-16,0
Th = 100°C
0,6
12,0-14,0
5
0,8
10,0-12,0
1,0
1
2
4
8
16
32
0
64
fsw (kHz)
1
10
At
Tj =
126
°C
At
Tj =
126
DC link =
Th =
400
80
V
°C
DC link =
Th from
400
V
60 °C to 100 °C in steps of 5 °C
Mi =
0
copyright by Vincotech
2
fsw (kHz)
100
°C
Revision: 1
10-F006PPA020SB01-M685B10
preliminary datasheet
Output Inverter Application
flowPIM0+PFC 2nd
Inverter
Figure 9
Inverter
Figure 10
Typical available peak output power as a function of
Pout=f(Th)
heatsink temperature
Typical efficiency as a function of output power
efficiency=f(Pout)
efficiency (%)
10
Pout (kW)
600V/20A
2kHz
100
8
99
2kHz
16kHz
6
98
4
16kHz
97
2
0
96
60
80
70
90
At
Tj =
126
DC link =
Mi =
cos φ=
fsw from
400
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
Th ( o C)
100
0
°C
2
4
6
At
Tj =
126
DC link =
Mi =
cos φ=
fsw from
400
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
8
10
Pout (kW)
12
°C
Inverter
Figure 11
Overload (%)
Typical available overload factor as a function of
Ppeak / Pnom=f(Pnom,fsw)
motor power and switching frequency
500
450
400
350
300
250
200
Switching frequency (kHz)
150
Motor nominal power (HP/kW)
100
2,00 / 1,47
3,00 / 2,21
5,00 / 3,68
7,50 / 5,52
10,00 / 7,36
15,00 / 11,03
1
499
333
200
133
0
0
2
499
333
200
133
0
0
4
499
333
200
133
0
0
8
469
313
188
125
0
0
16
395
263
158
0
0
0
At
Tj =
126
°C
DC link =
Mi =
400
1
V
cos φ=
fsw from
Th =
0,8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0,85
copyright by Vincotech
3
Revision: 1
V23990-P562-F10-PM
preliminary datasheet
Boost PFC Application
flowPIM0+PFC 2nd
600V/20A
General conditions
Boost PFC
VGEon
VGEoff
Rgon
Rgoff
Vin
=
=
=
=
=
10 V
0V
8Ω
8Ω
Vinpk*sinωt
MOSFET
Figure 1
FWD
Figure 2
Typical average static loss as a function of input current
Ploss = f(Iin)
Typical average static loss as a function of input current
Ploss = f(Iin)
Ploss (W)
40
Ploss (W)
125
Vinpk/Vout
=0.1
Vinpk/Vout=1
100
30
75
20
50
10
25
Vinpk/Vout
=0.1
Vinpk/Vout=1
0
0
0
At
Tj =
5
125
10
15
20
25
30
Iin (A)
35
0
At
Tj =
°C
Vinpk / Vout from 0,1 to 1 in steps of 0,1
5
125
10
15
20
25
30
Iin (A)
35
°C
Vinpk / Vout from 0,1 to 1 in steps of 0,1
MOSFET
Figure 3
Typical average switching loss
as a function of input current
FWD
Figure 4
Typical average switching loss
as a function of input current
Ploss = f(Iin)
Ploss = f(Iin)
Ploss (W)
2,5
Ploss (W)
80
fsw=160kHz
fsw=160kHz
2,0
60
1,5
40
1,0
20
0,5
fsw=20kHz
fsw=20kHz
0
0,0
0
At
Tj =
5
125
10
15
20
25
30
Iin (A)
35
0
At
Tj =
°C
DC link = 400
V
fsw from 20 kHz to 160 kHz in steps of factor 2
copyright by Vincotech
5
125
10
15
20
25
30
Iin (A)
35
°C
DC link = 400
V
fsw from 20 kHz to 160 kHz in steps of factor 2
4
Revision: 1
V23990-P562-F10-PM
preliminary datasheet
Boost PFC Application
flowPIM0+PFC 2nd
PFC
Figure 5
Typical available input current
as a function of Vinpk / Vout
600V/20A
PFC
Figure 6
Typical available input current
as a function of switching frequency
Iin = f(Vinpk/Vout)
30
Iin = f(fsw)
Iin (A)
30
Iin(A)
Th=60°C
Th=60°C
25
25
20
20
15
15
Th=100°C
10
10
5
5
Th=100°C
0
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
Vinpk/Vout
10
100
At
Tj =
125
°C
At
Tj =
125
°C
DC link =
fsw =
400
20
V
kHz
DC link = 400
Vinpk/Vout = 0,8
V
Th from 60 °C to 100 °C in steps of 5 °C
fsw (kHz)
1000
Th from 60 °C to 100 °C in steps of 5 °C
PFC
Figure 7
Typical available input current
as a function of switching frequency
0,1
0,3
22,0-24,0
Iin(A)
0,2
Iin = f(fsw)
25
Vinpk/Vout
Iin (A)
24,0-26,0
PFC
Figure 8
Typical available input current as a function of
of Vinpk / Vout and switching frequency
Iin = f(fsw, Vinpk/Vout)
20
Th=60°C
20,0-22,0
0,4
18,0-20,0
15
0,5
16,0-18,0
14,0-16,0
0,6
12,0-14,0
10
0,7
10,0-12,0
8,0-10,0
0,8
6,0-8,0
Th=100°C
5
0,9
10
20
40
80
160
1,0
320
0
10
fsw (kHz)
100
At
Tj =
125
°C
At
Tj =
125
°C
DC link =
Th =
400
80
V
°C
DC link = 400
Vinpk/Vout = 0,4
V
fsw (kHz)
1000
Th from 60 °C to 100 °C in steps of 5 °C
copyright by Vincotech
5
Revision: 1
V23990-P562-F10-PM
preliminary datasheet
Boost PFC Application
flowPIM0+PFC 2nd
PFC
Figure 9
600V/20A
PFC
Figure 10
Typical available electric input power as a function of
Pin = f(Th)
heatsink temperature
Typical efficiency as a function of input power
efficiency = f(Pin)
100,0
efficiency (%)
Pin (kW)
7
6
99,5
20kHz
5
99,0
20kHz
4
98,5
3
160kHz
98,0
2
160kHz
97,5
1
97,0
0
60
At
Tj =
65
70
125
DC link = 400
Vinpk/Vout = 0,8
75
80
85
90
0
95Th ( o C) 100
2
°C
At
Tj =
V
kHz
DC link = 400
Vinpk/Vout = 0,8
fsw from 20 kHz to 160 kHz in steps of factor 2
125
4
6
8
Pin (kW)
°C
V
kHz
fsw from 20 kHz to 160 kHz in steps of factor 2
PFC
Figure 11
PFC
Figure 12
Typical available electric input power as a function of
Pin = f(Th)
heatsink temperature
Typical efficiency as a function of input power
efficiency = f(Pin)
100
efficiency (%)
Pin (kW)
3,0
2,5
99
20kHz
20kHz
2,0
98
1,5
97
160kHz
1,0
96
0,5
95
160kHz
94
0,0
60
At
Tj =
70
80
125
°C
DC link = 400
Vinpk/Vout = 0,4
V
90
Th ( o C)
0,0
100
At
Tj =
fsw from 20 kHz to 160 kHz in steps of factor 2
copyright by Vincotech
0,5
1,0
125
°C
DC link = 400
Vinpk/Vout = 0,4
V
1,5
2,0
2,5
3,0
Pin (kW)
3,5
fsw from 20 kHz to 160 kHz in steps of factor 2
6
Revision: 1
V23990-P562-F10-PM
preliminary datasheet
Boost PFC Application
flowPIM0+PFC 2nd
Rectifier
Figure 13
Rectifier Bridge
Figure 14
Typical average static loss as a function of input current
Ploss = f(Iin)
Typical efficiency as a function of input power
efficiency = f(Pin)
100,0
efficiency (%)
20
Ploss (W)
600V/20A
18
16
99,5
Vinpk/Vout=
0,8
14
99,0
12
10
98,5
8
98,0
6
Vinpk/Vout=
0,4
4
97,5
2
0
97,0
0
At
Tj =
5
10
15
20
25
30
Iin (A)
35
0
At
Tj =
°C
125
Overall
Figure 15
125
4
6
8
°C
Overall
Typical efficiency as a function of input power
efficiency = f(Pin)
100
efficiency (%)
100
99
98
96
98
20kHz
160kHz
94
97
20kHz
160kHz
92
96
90
95
0
At
Tj =
Pin (kW)
Figure 16
Typical efficiency as a function of input power
efficiency = f(Pin)
efficiency (%)
2
2
125
DC link = 400
Vinpk/Vout = 0,8
4
6
Pin (kW)
0,0
8
1,0
°C
At
Tj =
°C
V
kHz
DC link = 400
Vinpk/Vout = 0,4
V
kHz
fsw from 20 kHz to 160 kHz in steps of factor 2
copyright by Vincotech
0,5
1,5
2,0
2,5
3,0
Pin (kW)
3,5
fsw from 20 kHz to 160 kHz in steps of factor 2
7
Revision: 1