15W DC-DC Converter P15B-Series ● ● ● ● ● ● ● ● Output current up to 4A 15 W maximum output power 2:1 wide input voltage range International safety approval Six-Sided continuous shield High efficiency up to 88% Standard 2" x 1" x 0.4" package Fixed switching frequency Model selection guide Typ Input nominal Input current voltage full-load [VDC] [mA] Single output P15B12S33 9 ... 18 1467 P15B12S05 9 ... 18 1603 P15B12S12 9 ... 18 1524 P15B12S15 9 ... 18 1524 P15B24S33 18 ... 36 724 P15B24S05 18 ... 36 781 P15B24S12 18 ... 36 772 P15B24S15 18 ... 36 772 P15B48S33 36 ... 75 357 P15B48S05 36 ... 75 396 P15B48S12 36 ... 75 377 P15B48S15 36 ... 75 381 Dual output P15B12D05 9 ... 18 1582 P15B12D12 9 ... 18 1524 P15B12D15 9 ... 18 1524 P15B24D05 18 ... 36 781 P15B24D12 18 ... 36 762 P15B24D15 18 ... 36 762 P15B48D05 36 ... 75 386 P15B48D12 36 ... 75 372 P15B48D15 36 ... 75 377 Output voltage [VDC] Output current [mA] Efficiency typ. [%] Capacitor load max. [uF] 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 4000 3000 1250 1000 4000 3000 1250 1000 4000 3000 1250 1000 79 82 86 86 80 84 85 85 81 83 87 86 10200 7050 1035 705 10200 7050 1035 705 10200 7050 1035 705 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 ±1500 ±625 ±500 ±1500 ±625 ±500 ±1500 ±625 ±500 83 86 84 84 85 86 85 88 87 2 x 1020 2 x 495 2 x 165 2 x 1020 2 x 495 2 x 165 2 x 1020 2 x 495 2 x 165 Page 1 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstraße 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 15W DC-DC Converter P15B-Series Specifications Input Voltage range Filter Input surge voltage for 100mS max. General Efficiency Switching frequency 9..18, 18..36, 36..75VDC π Pi type 12V type : 36 VDC max. 24V type : 50 VDC max. 48V type : 100 VDC max. Remote CTRL (Option) Positive logic Suffix “P” Negative logic Suffix “N” On: open or 3.5..12 VDC Off : 0...1.2 VDC On : 0...1.2 VDC Off: open or 3.5..12 VDC Remote CTRL input current Remote CTRL input reference Output Power Voltage accuracy Ripple and noise (at 20 MHz BW) Short circuit protection Line voltage regulation Load voltage regulation 10% to full load Transient response recovery time Temperature coefficient Minimum load -2.5mA -Input Isolation voltage Isolation Resistance Isolation Capacitance Environmental Operating temperature Storage temperature Maximum case temp. Thermal impedance Vibration Humidity Cooling Physical Dimensions 15W max ± 1% Single type: 50mVp-p Dual type: 75mVp-p Hiccup, automatics recovery ± 1% single: ± 1% dual: ±2% 500µs at 25% load chance Weight Case material See table Single output 500 kHz, typ Dual output 300 kHz, typ. 1600 VDC 9 10 Ω 300 pF, typ. -40 °C to +85 °C (with derating) -55 °C to +105 °C +100 °C 12°C/W 2G, 10-55Hz, 30 min., XYZ-axis 5% to 95% RH Free-air convection 1 x 2 inches 50.8x10.2x25.4 mm 27 g Nickel-coated copper ± 0.02% / °C 10% to maintain the specified regulation Dimensions Derating All dimensions in inches (mm) Pin Pitch tolerance ±0.014 (0.35) Pin connections Pin 1 2 3 4 5 6 Single + Input - Input + Output No pin - Output CTRL (Option) Dual + Input - Input + Output Common - Output CTRL (Option) Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 01 / 2005 f Page 2 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstraße 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]