MCP19110/11 MCP19110/11 Flash Memory Programming Specification This document includes the programming specification for the following devices: 1.1 This family of devices requires one power supply for VIN, see Table 6-1. The VDD that is used to bias all internal circuitry is internally generated and regulated to 5V. A 1 µF ceramic capacitor must be placed between the VDD and PGND pins. • MCP19110 • MCP19111 1.0 PROGRAMMING THE MCP19110/11 DEVICES 1.2 Program/Verify Mode The Program/Verify mode for this family of devices allows programming of user program memory, user ID locations, the Calibration Word and the Configuration Word. The MCP19110/11 devices are programmed using a serial method. The Serial mode will allow these devices to be programmed while in the user’s system. These programming specifications apply to all of the above devices in all packages. GPB2 GPB1 -VSEN +VSEN +ISEN -ISEN 23 22 21 20 19 PIN DIAGRAM – 24-PIN QFN (MCP19110) 24 FIGURE 1-1: Hardware Requirements GPA0 1 18 VDD GPA1 2 17 BOOT GPA2 3 16 HDRV 15 PHASE 14 VDR 13 LDRV MCP19110 GPA3 4 GPA7/ICSPCLK 5 EXP-25 2013 Microchip Technology Inc. 7 8 9 10 11 12 GPA4 GPB0 GND VIN PGND 6 GPA5/MCLR GPA6/ICSPDAT DS20002336B-page 1 MCP19110/11 TABLE 1-1: PIN DESCRIPTIONS IN PROGRAM/VERIFY MODE: MCP19110 During Programming Pin Name Function Pin Type GPA7 ICSPCLK I GPA6 ICSPDAT I/O MCLR Program/Verify mode Pin Description Clock Input – Schmitt Trigger Input Data Input/Output – Schmitt Trigger Input (1) Program Mode Select P VIN VIN P Device Power Supply Input VDD VDD P Power Supply Output GND VSS P Ground Legend: I = Input, O = Output, P = Power Note 1: In the MCP19110, the programming high voltage is internally generated. To activate the Program/Verify mode, voltage of VIHH and a current of IIHH (see Table 6-1) need to be applied to the MCLR input. 22 -ISEN 23 +ISEN GPB1 26 24 +VSEN GPB5/ICSPCLK/ICDCLK 27 QFN 25 -VSEN GPB2 28-PIN DIAGRAM FOR MCP19111 28 FIGURE 1-2: GPA0 1 21 GPB6 GPA1 2 20 VDD GPA2 3 19 BOOT GPB4/ICSPDAT/ICDDAT 4 18 HDRV GPA3 5 17 PHASE GPA7 6 16 VDR 15 LDRV MCP19111 EXP-29 DS20002336B-page 2 8 9 10 11 12 13 14 GPA4 GPB0 GPB7 GND VIN PGND 7 GPA5/MCLR GPA6 2013 Microchip Technology Inc. MCP19110/11 TABLE 1-2: PIN DESCRIPTIONS IN PROGRAM/VERIFY MODE: MCP19111 During Programming Pin Name Function Pin Type GPB5 ICSPCLK I GPB4 ICSPDAT I/O MCLR Program/Verify mode Pin Description Clock Input – Schmitt Trigger Input Data Input/Output – Schmitt Trigger Input (1) Program Mode Select P VIN VIN P Device Power Supply Input VDD VDD P Power Supply Output GND VSS P Ground Legend: I = Input, O = Output, P = Power Note 1: In the MCP19111, the programming high voltage is internally generated. To activate the Program/Verify mode, voltage of VIHH and a current of IIHH (see Table 6-1) need to be applied to the MCLR input. 2013 Microchip Technology Inc. DS20002336B-page 3 MCP19110/11 NOTES: DS20002336B-page 4 2013 Microchip Technology Inc. MCP19110/11 2.0 MEMORY DESCRIPTION 2.1 Program Memory Map The user memory space extends from 0x0000 to 0x1FFF. In Program/Verify mode, the program memory space extends from 0x0000 to 0x3FFF, with the first half (0x0000-0x1FFF) being user program memory and the second half (0x2000-0x3FFF) being configuration memory. The Program Counter (PC) will increment from 0x0000 to 0x1FFF and wrap to 0x0000. If the PC is between 0x2000 to 0x3FFF, it will wrap-around to 0x2000 (not to 0x0000). Once in configuration memory, the highest bit of the PC stays a ‘1’, thus always pointing to the configuration memory. The only way to point to user program memory is to reset the part and re-enter Program/Verify mode as described in Section 3.0 “Program/Verify Mode”. 2.3 Calibration Word For all of the devices covered in this document, Calibration Words are included to allow for storing the trim values for various analog peripherals (i.e., INTOSC module) at final test. These values are stored in the Calibration Words 0x2080, 0x2081, 0x2082 and 0x2083. See the applicable device data sheet for more information. The Calibration Words do not necessarily participate in the erase operation, unless a specific procedure is executed. Therefore, the device can be erased without affecting the Calibration Words. This simplifies the erase procedure, since these values do not need to be read and restored after the device is erased. For all of the devices covered in this document, the configuration memory space, 0x2000 to 0x208F, is physically implemented. However, only locations 0x2000 to 0x2003, 0x2007 and 0x2080 to 0x2083 are available. Other locations are reserved. 2.2 User ID Locations A user may store identification information (user ID) in four designated locations. The user ID locations are mapped in 0x2000 to 0x2003. It is recommended that the user use only the seven Least Significant bits (LSbs) of each user ID location. The user ID locations read out normally, even after code protection is enabled. It is recommended that ID locations are written as ‘xx xxxx xbbb bbbb’, where ‘bbb bbbb’ is the user ID information. The 14 bits may be programmed, but only the seven LSbs are read and displayed by the MPLAB® Integrated Development Environment (IDE). 2013 Microchip Technology Inc. DS20002336B-page 5 MCP19110/11 FIGURE 2-1: MCP19110/11 PROGRAM MEMORY MAPPING 4 kW Implemented 0FFF 2000 User ID Location 2001 User ID Location 2002 User ID Location 2003 User ID Location 2004 ICD Instruction 2005 Manufacturing Codes 2006 Device ID 2007 Configuration Word 2008-207F Reserved 2080-208F Calibration Words DS20002336B-page 6 Program Memory Maps to 0-FFF 1FFF 2000 Implemented 208F 2090 Unimplemented 2100 Maps to 2000-20FF Configuration Memory 3FFF 2013 Microchip Technology Inc. MCP19110/11 3.0 PROGRAM/VERIFY MODE FIGURE 3-2: Two methods are available to enter the Program/Verify mode. “VPP-first” is entered by holding ICSPDAT and ICSPCLK low while raising the MCLR pin from VIL to VIHH (high voltage), then applying VDD and data. This method can be used for any Configuration Word selection and must be used if the internal MCLR option is selected (MCLRE = 0). The VPP-first entry prevents the device from executing code prior to entering the Program/Verify mode. See the timing diagram in Figure 3-1. The second entry method, “VDD-first”, is entered by applying VDD, holding ICSPDAT and ICSPCLK low, then raising the MCLR pin from VIL to VIHH (high voltage), followed by data. This method can be used for any Configuration Word selection, except when the internal MCLR option is selected (MCLRE = 0). This programming technique is also useful when programming the device with VDD already applied, for it is not necessary to disconnect the VDD to enter the Program/Verify mode. See the timing diagram in Figure 3-2. THLD0 VDD ICSPDAT ICSPCLK Note: FIGURE 3-3: FIGURE 3-1: VPP-FIRST PROGRAM/ VERIFY MODE ENTRY TPPDP THLD0 This method of entry is valid if the internal MCLR is not selected. PROGRAM/VERIFY MODE EXIT THLD0 VPP VDD The sequence that enters the device into the Program/Verify mode places all other logic into the Reset state (the MCLR pin was initially at VIL). Therefore, all I/Os are in the Reset state (high-impedance inputs) and the PC is cleared. The MCP19110/11’s VDD is internally generated by applying voltage to the VIN pin. See Table 6-1 for the appropriate range for VIN. To remove VDD, VIN must be removed. TPPDP VPP Once in Program/Verify mode, the program memory and configuration memory can be accessed and programmed in a serial fashion. ICSPDAT and ICSPCLK are Schmitt Trigger inputs in this mode. To prevent a device configured with internal MCLR from executing after exiting Program/Verify mode, the VDD needs to power-down before VPP. See Figure 3-3 for the timing. VDD-FIRST PROGRAM/ VERIFY MODE ENTRY ICSPDAT ICSPCLK 3.1 Program/Erase Algorithms The MCP19110/11 program memory may be written in two ways. The fastest method writes four words at a time. However, one-word writes are also supported. The four-word algorithm is used to program the program memory only. The one-word algorithm can write any available memory location (i.e., program memory, configuration memory and calibration memory). After writing the array, the PC may be reset and read back to verify the write. It is not possible to verify immediately following the write because the PC can only increment, not decrement. A device Reset will clear the PC and set the address to ‘0’. The Increment Address command will increment the PC. The Load Configuration command will set the PC to 0x2000. The available commands are shown in Table 3-1. VPP VDD ICSPDAT ICSPCLK Note: This method of entry is regardless of Configuration selected. 2013 Microchip Technology Inc. valid, Word DS20002336B-page 7 MCP19110/11 3.1.1 FOUR-WORD PROGRAMMING The MCP19110/11 program memory can be written four words at a time using the four-word algorithm. Configuration memory (addresses >0x2000) and non-aligned (addresses modulo 4 not equal to zero) starting addresses must use the one-word programming algorithm. This algorithm writes four sequential addresses in program memory. The four addresses must point to a four-word block which address modulo 4 of 0, 1, 2 and 3. For example, programming addresses 4 through 7 can be programmed together. Programming addresses 2 through 5 will create an unexpected result. 3.1.2 ERASE ALGORITHMS The MCP19110/11 devices will erase different memory locations depending on the PC and CP. The following sequences can be used to erase noted memory locations. To erase the program memory and Configuration Word (0x2007), the following sequence must be performed. Note the Calibration Words (0x2080 to 0x208F) and user ID (0x2000-0x2003) will not be erased. 1. 2. Do a Bulk Erase Program Memory command. Wait TERA to complete erase. The sequence for programming four words of program memory at a time is: To erase the user ID (0x2000-0x2003), Configuration Word (0x2007) and program memory, use the following sequence. Note that the Calibration Words (0x2080 to 0x208F) will not be erased. 1. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Load a word at the current program memory address using the Load Data For Program Memory command. This location must be address modulo 4 equal to 0. Issue an Increment Address command to point to the next address in the block. Load a word at the current program memory address using the Load Data For Program Memory command. Issue an Increment Address command to point to the next address in the block. Load a word at the current program memory address using the Load Data For Programming Memory command. Issue and Increment Address command to point to the next address in the book. Load a word at the current program memory address using the Load Data For Programming Memory command. Issue a Begin Programming command externally timed. Wait TPROG1. Issue End Programming. Wait TDIS. Issue an Increment Address command to point to the start of the next block of addresses. Repeat steps 1 through 12 as required to write the desired range of program memory. See Table 3-12 for more information. 2. 3. Perform Load Configuration with dummy data to point the PC to 0x2000. Perform a Bulk Erase Program Memory command. Wait TERA to complete erase. 3.1.3 SERIAL PROGRAM/VERIFY OPERATION The ICSPCLK pin is used as a clock input, and the ICSPDAT pin is used for entering command bits and data input/output during serial operation. To input a command, ICSPCLK is cycled six times. Each command bit is latched on the falling edge of the clock with the LSb of the command being input first. The data input onto the ICSPDAT pin is required to have a minimum setup and hold time (see Table 6-1), with respect to the falling edge of the clock. Commands that have data associated with them (Read and Load) are specified to have a minimum delay of 1 µs between the command and the data. After this delay, the clock pin is cycled 16 times with the first cycle being a Start bit and the last cycle being a Stop bit. During a read operation, the LSb will be transmitted onto the ICSPDAT pin on the rising edge of the second cycle. For a load operation, the LSb will be latched on the falling edge of the second cycle. A minimum 1 µs delay is also specified between consecutive commands, except for the End Programming command, which requires a 100 µs (TDIS). All commands and data words are transmitted LSb first. Data is transmitted on the rising edge and latched on the falling edge of the ICSPCLK. To allow for decoding of commands and reversal of data pin configuration, a time separation of at least 1 µs (TDLY1) is required between a command and a data word. The commands that are available are described in Table 3-1. DS20002336B-page 8 2013 Microchip Technology Inc. MCP19110/11 TABLE 3-1: COMMAND MAPPING FOR MCP19110/11 Command Mapping (MSb … LSb) Load Configuration x x 0 0 Data 0 0, data (14), 0 0 Load Data for Program Memory x x 0 0 1 0 0, data (14), 0 Read Data from Program Memory x x 0 1 0 0 0, data (14), 0 Increment Address x x 0 1 1 0 Begin Programming x 1 1 0 0 0 End Programming x 0 1 0 1 0 Bulk Erase Program Memory x x 1 0 0 1 Internally Timed Row Erase Program Memory x 1 0 0 0 1 Internally Timed 3.1.3.1 Externally Timed Load Configuration The Load Configuration command is used to access the Configuration Word (0x2007), user ID (0x2000-0x2003) and Calibration Words (0x2080 to 0x208F). This command sets the PC to address 0x2000 and loads the data latches with one word of data. To access the configuration memory, send the Load Configuration command. Individual words within the configuration memory can be accessed by sending Increment Address commands and using load or read data for program memory. After the 6-bit command is input, the ICSPCLK pin is cycled an additional 16 times for the Start bit, 14 bits of data and the Stop bit (see Figure 3-4). After the configuration memory is entered, the only way to get back to the program memory is to exit the Program/Verify mode by taking MCLR low (VIL). FIGURE 3-4: LOAD CONFIGURATION COMMAND TDLY3 1 2 3 4 5 1 6 2 3 4 5 15 16 ICSPCLK ICSPDAT 0 00 0 0 X X TDLY1 2013 Microchip Technology Inc. strt_bit LSb MSb stp_bit TSET1 THLD1 DS20002336B-page 9 MCP19110/11 3.1.3.2 Load Data For Program Memory After receiving this command, the chip will load in a 14-bit “data word” when 16 cycles are applied, as described in Section 3.1.3.1 “Load Configuration”. A timing diagram of this command is shown in Figure 3-5. FIGURE 3-5: LOAD DATA FOR PROGRAM MEMORY COMMAND 1 2 3 4 5 6 TDLY2 1 2 3 4 5 15 16 ICSPCLK 3.1.3.3 1 0 ICSPDAT 0 0 X TSET1 THLD1 strt_bit LSb X MSb stp_bit TSET1 THLD1 TDLY1 Read Data From Program Memory After receiving this command, the chip will transmit data bits out of the program memory (user or configuration) currently accessed, starting with the second rising edge of the clock input. The data pin will go into Output mode on the second rising clock edge, and it will revert to Input mode (high-impedance) after the 16th rising edge. If the program memory is code-protected (CP = 0), the data is read as zeros. A timing diagram of this command is shown in Figure 3-6. FIGURE 3-6: READ DATA FROM PROGRAM MEMORY COMMAND TDLY3 1 2 3 4 1 0 5 6 1 2 ICSPCLK ICSPDAT 4 5 15 16 TDLY3 10 0 X X strt_bit TSET1 THLD1 input DS20002336B-page 10 3 MSb stp_bit LSb TDLY1 output input 2013 Microchip Technology Inc. MCP19110/11 3.1.3.4 Increment Address The PC is incremented when this command is received. A timing diagram of this command is shown in Figure 3-7. Incrementing past 0x07FF in the program memory rolls the program counter to ‘0’. Incrementing past 203Fh in test memory returns the program counter to 2000h. It is not possible to decrement the address counter. To reset this counter, the user should exit and re-enter Program/Verify mode. FIGURE 3-7: INCREMENT ADDRESS COMMAND (PROGRAM/VERIFY) TDLY2 1 2 3 4 5 1 0 Next Command 2 1 6 ICSPCLK 0 ICSPDAT 1 X X X 0 TSET1 THLD1 3.1.3.5 TDLY1 Begin Programming (Externally Timed) A Load command must be given before every Begin Programming command. Programming of the appropriate memory (program memory, configuration or calibration memory) will begin after this command is received and decoded. Programming requires (TPROG) time and is terminated using an End Programming command. A timing diagram for this command is shown in Figure 3-8. The addressed locations are not erased before programming. FIGURE 3-8: BEGIN PROGRAMMING (EXTERNALLY TIMED) VIHH TPROG MCLR 1 2 3 4 0 0 0 1 5 6 End Programming Command 1 2 ICSPCLK ICSPDAT 1 X X 0 TSET1 THLD1 2013 Microchip Technology Inc. DS20002336B-page 11 MCP19110/11 3.1.3.6 End Programming After this command is performed, the write procedure will stop. A timing diagram of this command is shown in Figure 3-9. FIGURE 3-9: END PROGRAMMING (SERIAL PROGRAM/VERIFY) VIHH MCLR Next Command 1 2 3 0 1 0 4 5 1 6 2 ICSPCLK ICSPDAT 1 0 X X TDIS 0 TSET1 THLD1 3.1.3.7 Bulk Erase Program Memory After this command is performed, the entire program memory and the Configuration Word (0x2007) are erased. The user ID and calibration memory may also be erased, depending on the value of the PC. See Section 3.1.2 “Erase Algorithms” for erase sequences. A timing diagram for this command is shown in Figure 3-10. FIGURE 3-10: BULK ERASE PROGRAM MEMORY COMMAND TERA 1 2 3 0 0 4 5 6 Next Command 2 1 ICSPCLK 1 ICSPDAT X X X 0 TSET1 TSET1 THLD1 DS20002336B-page 12 1 THLD1 2013 Microchip Technology Inc. MCP19110/11 3.1.3.8 Row Erase Program Memory To perform a Row Erase Program Memory, the following sequence must be performed: This command erases the 16-word row of program memory pointed to by PC<11:4>. If the program memory array is protected (CP = 0), the command is ignored. FIGURE 3-11: 1. 2. Execute a Row Erase Program Memory command. Wait TERA to complete a row erase. ROW ERASE PROGRAM MEMORY COMMAND TERA 1 2 3 4 5 1 0 0 0 1 Next Command 2 1 6 ICSPCLK ICSPDAT FIGURE 3-12: x x 0 ONE-WORD PROGRAMMING FLOWCHART Start Bulk Erase Program Memory (1,2) Program Cycle Load Data for Program Memory One-word Program Cycle Begin Programming Command (Externally timed) Read Data from Program Memory Data Correct? No Report Programming Failure Wait TPROG Yes Increment Address Command No All Locations Done? End Programming Yes Program User ID/Config. bits Wait TDIS Done Note 1: This step is optional if the device has already been erased or has not been previously programmed. 2: If the device is code-protected or must be completely erased, then bulk erase the device per Figure 3-15. 2013 Microchip Technology Inc. DS20002336B-page 13 MCP19110/11 FIGURE 3-13: FOUR-WORD PROGRAMMING FLOWCHART Program Cycle Load Data for Program Memory Increment Address Command Start Bulk Erase Program Memory(1,2) Increment Address Command No Load Data for Program Memory Four-word Program Cycle Increment Address Command All Locations Done? Load Data for Program Memory Yes Program User ID/Config. bits Done Increment Address Command Load Data for Program Memory Begin Programming Command (Externally timed) Wait TPROG End Programming Wait TDIS Note 1: This step is optional if the device is erased or not previously programmed. 2: If the device is code-protected or must be completely erased, then bulk erase the device per Figure 3-15. DS20002336B-page 14 2013 Microchip Technology Inc. MCP19110/11 FIGURE 3-14: PROGRAM FLOWCHART – CONFIGURATION MEMORY Start PROGRAM CYCLE Load Configuration Load Data for Program Memory One-word Program Cycle (User ID) Begin Programming Command (Externally timed) Read Data From Program Memory Command Wait TPROG Data Correct? Report Programming Failure No End Programming Yes Increment Address Command Wait TDIS No Address = 0x2004? Yes Increment Address Command Increment Address Command Increment Address Command One-word Program Cycle (Config. bits) Read Data From Program Memory Command Data Correct? No Report Programming Failure Yes Done 2013 Microchip Technology Inc. DS20002336B-page 15 MCP19110/11 FIGURE 3-15: PROGRAM FLOWCHART – ERASE FLASH DEVICE Start Load Configuration Bulk Erase (1) Program Memory Done Note 1: See Section 3.1.3.7 “Bulk Erase Program Memory” for more information on the Bulk Erase procedure. DS20002336B-page 16 2013 Microchip Technology Inc. MCP19110/11 4.0 CONFIGURATION WORD The MCP19110/11 devices have several Configuration bits. These bits can be programmed (reads ‘0’) or left unchanged (reads ‘1’), to select various device configurations. REGISTER 4-1: CONFIG: CONFIGURATION WORD (ADDRESS: 2007h) R/W-1 U-1 R/W-1 R/W-1 U-1 U-1 DBGEN — WRT1 WRT0 — — bit 13 bit 8 U-0 R/W-1 R/W-1 R/W-1 R/W-1 U-1 U-1 U-1 — CP MCLRE PWRTE WDTE — — — bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’ -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bit 13 DBGEN: ICD Debug bit 1 = ICD Debug mode disabled 0 = ICD Debug mode enabled bit 12 Unimplemented: Read as ‘1’ bit 11-10 WRT<1:0>: Flash Program Memory Self-Write Enable bit 11 = Write protection off 10 = 000h to 3FFh write protected, 400h to FFFh may be modified by PMCON1 control 01 = 000h to 7FFh write protected, 800h to FFFh may be modified by PMCON1 control 00 = 000h to FFFh write protected, the entire program memory is write-protected bit 9-7 Unimplemented: Read as ‘1’ bit 6 CP: Code Protection bit 1 = Program memory is not code-protected 0 = Program memory is external read and write-protected bit 5 MCLRE: MCLR Pin Function Select bit 1 = MCLR pin is MCLR function and weak internal pull-up is enabled 0 = MCLR pin is alternate function, MCLR function is internally disabled bit 4 PWRTE: Power-up Timer Enable bit(1) 1 = PWRT disabled 0 = PWRT enabled bit 3 WDTE: Watchdog Timer Enable bit 1 = WDT enabled 0 = WDT disabled bit 2-0 Note 1: Unimplemented: Read as ‘1’ Bit is reserved and not controlled by user. 2013 Microchip Technology Inc. DS20002336B-page 17 MCP19110/11 4.1 Device ID Word The device ID word for the MCP19110/11 is loaded at 2006h. This location cannot be erased. TABLE 4-1: DEVICE ID VALUES Device ID Values Device Dev Rev MCP19110 00 0111 111 0 0010 MCP19111 10 1111 100 0 0010 DS20002336B-page 18 2013 Microchip Technology Inc. MCP19110/11 5.0 CODE PROTECTION 5.3 Checksum Computation For the MCP19110/11, once the CP bit is programmed to ‘0’, all program memory locations read all ‘0’s. The user ID locations and the Configuration Word read out in an unprotected fashion. Further programming is disabled for the entire program memory. The checksum is calculated by two different methods dependent on the setting of the CP Configuration bit. The user ID locations and the Configuration Word can be programmed regardless of the state of the CP bit. With the program code protection disabled, the checksum is computed by reading the contents of the program memory locations and adding up the program memory data starting at address 0x0000h, up to the maximum user addressable location. Any Carry bit exceeding 16 bits is ignored. Additionally, the relevant bits of the Configuration Words are added to the checksum. All unimplemented Configuration bits are masked to ‘0’. 5.1 Disabling Code Protection It is recommended to use the procedure in Figure 3-15 to disable code protection of the device. This sequence will erase the program memory, Configuration Word (0x2007) and user ID locations (0x2000-0x2003). The Calibration Words (0x2080 to 0x2083) will not be erased. 5.2 5.3.1 PROGRAM CODE PROTECTION DISABLED Embedding Configuration Word and User ID Information in the Hex File To allow portability of code, the programmer is required to read the Configuration Word and user ID locations from the hex file when loading it. If Configuration Word information was not present in the hex file, a simple warning message may be issued. Similarly, while saving a hex file, Configuration Word and user ID information must be included. An option to not include this information may be provided. Microchip Technology Inc. feels strongly that this feature is important for the benefit of the end customer. EXAMPLE 5-1: CHECKSUM COMPUTED WITH PROGRAM CODE PROTECTION DISABLED (CP = 1), MCP19110 AND MCP19111 BLANK DEVICES Sum of Memory addresses 000h-0FFFh F000h 1 Configuration Word 3FFFh 2 Configuration Word mask 2C78h 3 Checksum = F000h + (3FFFh and 2C78h) 4 = F000h + 2C78h = 1C78h Note 1: This value is obtained by taking the total number of program memory locations (0x000h to 0x0FFFh, which is 0x1000h) and multiplying it by the blank memory value of 0x3FFF to get the sum of 3FF F000h. Then truncate to 16 bits, thus having a final value of F000h. 2: This value is obtained by making all bits of the Configuration Word a ‘1’, then converting it to hex, thus having a value of 3FFFh. 3: This value is obtained by making all used bits of the Configuration Word a ‘1’, then converting it to hex, thus having a value of 2C78h. 4: This value is obtained by ANDing the Configuration Word value with the Configuration Word Mask value and adding it to the sum of memory addresses (3FFFh and 2C78) + F000h = 11C78h. Then truncate to 16 bits, thus having a final value of 1C78h. 2013 Microchip Technology Inc. DS20002336B-page 19 MCP19110/11 5.3.2 PROGRAM CODE PROTECTION ENABLED With the program code protection enabled, the checksum is computed in the following manner. The Least Significant nibble of each user ID is used to create a 16-bit value. The masked value of user ID location 2000h is the Most Significant nibble. This sum of user IDs is summed with the Configuration Word (all unimplemented Configuration bits are masked to ‘0’). EXAMPLE 5-2: CHECKSUM COMPUTED WITH PROGRAM CODE PROTECTION ENABLED (CP = 0), MCP19110 AND MCP19111 BLANK DEVICES Configuration Word 3FBFh(1) Configuration Word mask 2C38h(2) User ID (2000h) 0006h(3) User ID (2001h) 0007h(3) User ID (2002h) 0001h(3) User ID (2003h) 0002h(3) Sum of User IDs = (0006h and 000Fh) << 12 + (0007h and 000Fh) << 8 + (0001h and 000Fh) << 4 + (0002h and 000Fh)(4) = 6000h + 0700h + 0010h + 0002h = 6712h Checksum = (3FBFh and 2C38h) + Sum of User IDs(5) = 2C38h + 6712h = 934Ah Note 1: This value is obtained by making all bits of the Configuration Word a ‘1’, but the code protection bit is ‘0’ (thus, enabled), then converting it to a hex, thus having a value of 3FBFh. 2: This value is obtained by making all used bits of the Configuration Word a ‘1’, but the code protection bit is ‘0’ (thus, enabled), then converting to hex, thus having a value of 2C38h. 3: These values are picked at random for this example; they can be any 16-bit value. 4: In order to calculate the sum of user IDs, take the 16-bit value of the first user ID location (0006h), AND the address to (000Fh), thus masking the MSB. This gives you the value 0006h, then shift left 12 bits, giving you 6000h. Do the same procedure for the 16-bit value of the second user ID location (0007h), except shift left eight bits. Also do the same for the third user ID location (0001h), except shift left four bits. For the fourth user ID location, do not shift. Finally, add up all four user ID values to get the final sum of user IDs of 6712h. 5: This value is obtained by ANDing the Configuration Word value with the Configuration Mask value and adding it to the sum of user IDs: (3FBFh and 2C38h) + (6712h) = 934Ah. DS20002336B-page 20 2013 Microchip Technology Inc. MCP19110/11 6.0 PROGRAM/VERIFY MODE ELECTRICAL CHARACTERISTICS TABLE 6-1: AC/DC CHARACTERISTICS TIMING REQUIREMENTS FOR PROGRAM/VERIFY MODE AC/DC CHARACTERISTICS Sym. Characteristics Standard Operating Conditions (unless otherwise stated) Operating Temperature: -40°C TA +85°C Operating Voltage: 4.5V VDD 5.5V Min. Typ. Max. Units Conditions/Comments VIN level for read/write operations, program and data memory 4.5 — 32 V VIN level for Bulk Erase operations, program and data memory 4.5 — 32 V VDD + 3.5 — 13 V VDD regulated internally to 5V Current into the MCLR pin General VIN VIHH High voltage on MCLR for Program/Verify mode entry IIHH MCLR current during programming — 300 1000 µA MCLR rise time (VSS to VHH) for Program/Verify mode entry — — 1.0 µs TVHHR Hold time after VPPchanges 5 — — µs (ICSPCLK, ICSPDAT) input high level 0.8 VDD — — V Schmitt Trigger input (ICSPCLK, ICSPDAT) input low level 0.2 VDD — — V Schmitt Trigger input 100 — — ns 5 — — µs Data in setup time before clock 100 — — ns THLD1 Data in hold time after clock 100 — — ns TDLY1 Data input not driven to next clock input (delay required between command/data or command/command) 1.0 — — µs TDLY2 Delay between clockto clockof next command or data 1.0 — — µs TDLY3 Clock to data out valid (during a Read Data command) — — 80 ns TERA Erase cycle time — 5 6 ms Programming cycle time 3 — — ms 100 — — µs TPPDP VIH1 VIL1 TSET0 ICSPCLK, ICSPDAT setup time before MCLR (Program/Verify mode selection pattern setup time) THLD0 Hold time after VDD changes Serial Program/Verify TSET1 TPROG TDIS Time delay from program to compare (HV discharge time) 2013 Microchip Technology Inc. +10°C TA +40°C DS20002336B-page 21 MCP19110/11 NOTES: DS20002336B-page 22 2013 Microchip Technology Inc. MCP19110/11 APPENDIX A: REVISION HISTORY Revision B (July 2013) The following is the list of modifications: 1. 2. 3. 4. 5. Adding new device MCP19110 to the family and the related information throughout the document. Added pinout diagram for MCP19110 device in Figure 1-1. Added Table 1-1 containing the pin descriptions in Program/Verify mode for MCP19110 device. Updated Table 4-1. Fixed minor typographical errors. Revision A (March 2013) • Original release of this document. 2013 Microchip Technology Inc. DS20002336B-page 23 MCP19110/11 NOTES: DS20002336B-page 24 2013 Microchip Technology Inc. Note the following details of the code protection feature on Microchip devices: • Microchip products meet the specification contained in their particular Microchip Data Sheet. • Microchip believes that its family of products is one of the most secure families of its kind on the market today, when used in the intended manner and under normal conditions. • There are dishonest and possibly illegal methods used to breach the code protection feature. All of these methods, to our knowledge, require using the Microchip products in a manner outside the operating specifications contained in Microchip’s Data Sheets. Most likely, the person doing so is engaged in theft of intellectual property. • Microchip is willing to work with the customer who is concerned about the integrity of their code. • Neither Microchip nor any other semiconductor manufacturer can guarantee the security of their code. Code protection does not mean that we are guaranteeing the product as “unbreakable.” Code protection is constantly evolving. We at Microchip are committed to continuously improving the code protection features of our products. Attempts to break Microchip’s code protection feature may be a violation of the Digital Millennium Copyright Act. If such acts allow unauthorized access to your software or other copyrighted work, you may have a right to sue for relief under that Act. Information contained in this publication regarding device applications and the like is provided only for your convenience and may be superseded by updates. It is your responsibility to ensure that your application meets with your specifications. MICROCHIP MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION, INCLUDING BUT NOT LIMITED TO ITS CONDITION, QUALITY, PERFORMANCE, MERCHANTABILITY OR FITNESS FOR PURPOSE. Microchip disclaims all liability arising from this information and its use. Use of Microchip devices in life support and/or safety applications is entirely at the buyer’s risk, and the buyer agrees to defend, indemnify and hold harmless Microchip from any and all damages, claims, suits, or expenses resulting from such use. No licenses are conveyed, implicitly or otherwise, under any Microchip intellectual property rights. Trademarks The Microchip name and logo, the Microchip logo, dsPIC, FlashFlex, KEELOQ, KEELOQ logo, MPLAB, PIC, PICmicro, PICSTART, PIC32 logo, rfPIC, SST, SST Logo, SuperFlash and UNI/O are registered trademarks of Microchip Technology Incorporated in the U.S.A. and other countries. FilterLab, Hampshire, HI-TECH C, Linear Active Thermistor, MTP, SEEVAL and The Embedded Control Solutions Company are registered trademarks of Microchip Technology Incorporated in the U.S.A. Silicon Storage Technology is a registered trademark of Microchip Technology Inc. in other countries. Analog-for-the-Digital Age, Application Maestro, BodyCom, chipKIT, chipKIT logo, CodeGuard, dsPICDEM, dsPICDEM.net, dsPICworks, dsSPEAK, ECAN, ECONOMONITOR, FanSense, HI-TIDE, In-Circuit Serial Programming, ICSP, Mindi, MiWi, MPASM, MPF, MPLAB Certified logo, MPLIB, MPLINK, mTouch, Omniscient Code Generation, PICC, PICC-18, PICDEM, PICDEM.net, PICkit, PICtail, REAL ICE, rfLAB, Select Mode, SQI, Serial Quad I/O, Total Endurance, TSHARC, UniWinDriver, WiperLock, ZENA and Z-Scale are trademarks of Microchip Technology Incorporated in the U.S.A. and other countries. SQTP is a service mark of Microchip Technology Incorporated in the U.S.A. GestIC and ULPP are registered trademarks of Microchip Technology Germany II GmbH & Co. KG, a subsidiary of Microchip Technology Inc., in other countries. All other trademarks mentioned herein are property of their respective companies. © 2013, Microchip Technology Incorporated, Printed in the U.S.A., All Rights Reserved. Printed on recycled paper. ISBN: 978-1-62077-299-7 QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV == ISO/TS 16949 == 2013 Microchip Technology Inc. Microchip received ISO/TS-16949:2009 certification for its worldwide headquarters, design and wafer fabrication facilities in Chandler and Tempe, Arizona; Gresham, Oregon and design centers in California and India. The Company’s quality system processes and procedures are for its PIC® MCUs and dsPIC® DSCs, KEELOQ® code hopping devices, Serial EEPROMs, microperipherals, nonvolatile memory and analog products. In addition, Microchip’s quality system for the design and manufacture of development systems is ISO 9001:2000 certified. DS20002336B-page 25 Worldwide Sales and Service AMERICAS ASIA/PACIFIC ASIA/PACIFIC EUROPE Corporate Office 2355 West Chandler Blvd. Chandler, AZ 85224-6199 Tel: 480-792-7200 Fax: 480-792-7277 Technical Support: http://www.microchip.com/ support Web Address: www.microchip.com Asia Pacific Office Suites 3707-14, 37th Floor Tower 6, The Gateway Harbour City, Kowloon Hong Kong Tel: 852-2401-1200 Fax: 852-2401-3431 India - Bangalore Tel: 91-80-3090-4444 Fax: 91-80-3090-4123 India - New Delhi Tel: 91-11-4160-8631 Fax: 91-11-4160-8632 Austria - Wels Tel: 43-7242-2244-39 Fax: 43-7242-2244-393 Denmark - Copenhagen Tel: 45-4450-2828 Fax: 45-4485-2829 India - Pune Tel: 91-20-2566-1512 Fax: 91-20-2566-1513 France - Paris Tel: 33-1-69-53-63-20 Fax: 33-1-69-30-90-79 Japan - Osaka Tel: 81-6-6152-7160 Fax: 81-6-6152-9310 Germany - Munich Tel: 49-89-627-144-0 Fax: 49-89-627-144-44 Atlanta Duluth, GA Tel: 678-957-9614 Fax: 678-957-1455 Boston Westborough, MA Tel: 774-760-0087 Fax: 774-760-0088 Chicago Itasca, IL Tel: 630-285-0071 Fax: 630-285-0075 Cleveland Independence, OH Tel: 216-447-0464 Fax: 216-447-0643 Dallas Addison, TX Tel: 972-818-7423 Fax: 972-818-2924 Detroit Farmington Hills, MI Tel: 248-538-2250 Fax: 248-538-2260 Indianapolis Noblesville, IN Tel: 317-773-8323 Fax: 317-773-5453 Los Angeles Mission Viejo, CA Tel: 949-462-9523 Fax: 949-462-9608 Santa Clara Santa Clara, CA Tel: 408-961-6444 Fax: 408-961-6445 Toronto Mississauga, Ontario, Canada Tel: 905-673-0699 Fax: 905-673-6509 Australia - Sydney Tel: 61-2-9868-6733 Fax: 61-2-9868-6755 China - Beijing Tel: 86-10-8569-7000 Fax: 86-10-8528-2104 China - Chengdu Tel: 86-28-8665-5511 Fax: 86-28-8665-7889 China - Chongqing Tel: 86-23-8980-9588 Fax: 86-23-8980-9500 Korea - Daegu Tel: 82-53-744-4301 Fax: 82-53-744-4302 China - Hangzhou Tel: 86-571-2819-3187 Fax: 86-571-2819-3189 Korea - Seoul Tel: 82-2-554-7200 Fax: 82-2-558-5932 or 82-2-558-5934 China - Hong Kong SAR Tel: 852-2943-5100 Fax: 852-2401-3431 Malaysia - Kuala Lumpur Tel: 60-3-6201-9857 Fax: 60-3-6201-9859 China - Nanjing Tel: 86-25-8473-2460 Fax: 86-25-8473-2470 Malaysia - Penang Tel: 60-4-227-8870 Fax: 60-4-227-4068 China - Qingdao Tel: 86-532-8502-7355 Fax: 86-532-8502-7205 Philippines - Manila Tel: 63-2-634-9065 Fax: 63-2-634-9069 China - Shanghai Tel: 86-21-5407-5533 Fax: 86-21-5407-5066 Singapore Tel: 65-6334-8870 Fax: 65-6334-8850 China - Shenyang Tel: 86-24-2334-2829 Fax: 86-24-2334-2393 Taiwan - Hsin Chu Tel: 886-3-5778-366 Fax: 886-3-5770-955 China - Shenzhen Tel: 86-755-8864-2200 Fax: 86-755-8203-1760 Taiwan - Kaohsiung Tel: 886-7-213-7828 Fax: 886-7-330-9305 China - Wuhan Tel: 86-27-5980-5300 Fax: 86-27-5980-5118 Taiwan - Taipei Tel: 886-2-2508-8600 Fax: 886-2-2508-0102 China - Xian Tel: 86-29-8833-7252 Fax: 86-29-8833-7256 Thailand - Bangkok Tel: 66-2-694-1351 Fax: 66-2-694-1350 Italy - Milan Tel: 39-0331-742611 Fax: 39-0331-466781 Netherlands - Drunen Tel: 31-416-690399 Fax: 31-416-690340 Spain - Madrid Tel: 34-91-708-08-90 Fax: 34-91-708-08-91 UK - Wokingham Tel: 44-118-921-5869 Fax: 44-118-921-5820 China - Xiamen Tel: 86-592-2388138 Fax: 86-592-2388130 China - Zhuhai Tel: 86-756-3210040 Fax: 86-756-3210049 DS20002336B-page 26 Japan - Tokyo Tel: 81-3-6880- 3770 Fax: 81-3-6880-3771 11/29/12 2013 Microchip Technology Inc.