NEC EXPRESS5800/R140b-4 Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC EXPRESS5800 server. October 2011 Revision 8.2 NEC Corporation CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 5 Front and Rear Views ........................................................................................................................... 5 Dimensions (mm) .................................................................................................................................. 6 CONFIGURATION DIAGRAM ......................................................................................... 7 SERVER CONFIGURATION ........................................................................................... 8 1 2 3 Base Models ................................................................................................................................... 8 Processor ....................................................................................................................................... 8 Memory ........................................................................................................................................... 8 3.1 Memory Board ....................................................................................................................... 8 3.2 Memory Kit............................................................................................................................. 9 4 Internal Hard Disk Drives ............................................................................................................ 10 4.1 RAID Configuration .............................................................................................................. 10 4.2 Internal Drive Configuration ................................................................................................. 11 5 Optical Drive ................................................................................................................................. 14 6 Internal Tape / RDX Drives .......................................................................................................... 14 6.1 Tape / RDX Drive Selection ................................................................................................. 14 6.2 Tape / RDX Configuration .................................................................................................... 15 7 PCI Card ........................................................................................................................................ 16 7.1 LAN Controller ..................................................................................................................... 16 7.2 External RAID Controller ..................................................................................................... 17 7.3 Fibre Channel / SAS / SCSI Controller ................................................................................ 17 7.4 Serial Port Adapter .............................................................................................................. 18 8 Other Add-in Components .......................................................................................................... 18 8.1 Redundant Power Supply .................................................................................................... 18 8.2 VMware ESXi Pre-install Kit ................................................................................................ 18 9 Add-on Components ................................................................................................................... 19 9.1 17-inch LCD Console Drawer .............................................................................................. 19 9.2 KVM Switch ......................................................................................................................... 19 9.3 Server Management License............................................................................................... 19 9.4 Front Bezel .......................................................................................................................... 20 9.5 Flash FDD............................................................................................................................ 20 9.6 Medium and Cartridge ......................................................................................................... 20 10 Support Service .......................................................................................................................... 20 10.1 Software ............................................................................................................................ 20 REFERENCES............................................................................................................... 21 Server Management ............................................................................................................................ 21 OS Support Matrix for PCI Cards ...................................................................................................... 22 Supporting PCI Cards and Installable Slots ..................................................................................... 23 Copyright Notice and Liability Disclaimer ........................................................................................ 24 REVISION HISTORY ..................................................................................................... 25 NEC Corporation Revision 8.2, October 2011 2 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Technical Specification Key Features High performance with the latest Intel® Xeon® processor 7500 series Up to 512 GB of high speed DDR3-1066 memory High energy efficiency with power capping feature and 80 PLUS® Gold power supply Full manageability by integrated EXPRESSSCOPE Engine 2 Specification Model R140b-4 Part Number N8100-1601F Processor Type Intel® Xeon® processor E7520 Intel® Xeon® processor E7530 Intel® Xeon® processor X7560 Clock speed 1.86 GHz 1.86 GHz 2.26 GHz Number of Processors 2 or 4 Cache 18 MB 12 MB 24 MB Cores and Threads 4C-8T 6C-12T 8C-16T Chipset Memory Internal Storage Expansion Slots [free] 2 x Intel® 7500 Chipset Type DDR3-1066 ECC Registered DIMM Standard Capacity 0 GB Maximum Capacity 512 GB (64 x 8 GB) Memory protection ECC, x4 SDDC, x8 SDDC, Memory Mirroring, Memory Sparing Standard Capacity 0 GB Maximum Capacity SAS : 7.2 TB (8 x 900 GB) SATA : 8 TB (8 x 1 TB) SSD : 800 GB (8 x 100 GB) Disk Controller SATA : 3Gb/s (Optional) SAS: 6Gb/s (Optional) RAID SATA : RAID 0/1/5/6/10/50 (Optional) SAS : RAID 0/1/5/6/10/50 (Optional) Hot Plug Supported Optical Disk Drive Optional Optical Drive Bays [free] 5-inch Media Bays [free] Disk Drive Bays [free] 1 [1] Standard Total: 11 slots available 1[1] x PCIe 2.0 x16 (x16 connector) 4[4] x PCIe 2.0 x8 (x8 connector), hot plug 1[1] x PCIe 2.0 x8 (x8 connector) 3[3] x PCIe 2.0 x4 (x8 connector) 2[2] x PCIe x4 (x8 connector) 1 [1] 8 [8] Video Controller (VRAM) Integrated in Server Management Controller (32MB) Interfaces 2 x VGA (15-pin mini D-sub, 1 x front, 1 x rear) 1 x Serial (9-pin mini D-sub, RS232-C, Serial A, 1 x rear) 8 x USB2.0 (3 x front, 2 x rear, 3 x internal) 4 x 1000BASE-T LAN connector (1000BASE-T / 100BASE-TX / 10BASE-T, RJ-45, 4 x rear) 1 x Management LAN connector (1000BASE-T / 100BASE-TX / 10BASE-T, RJ-45, 1 x rear) NEC Corporation Revision 8.2, October 2011 3 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Model R140b-4 Server Management EXPRESSSCOPE Engine 2 Redundant Fan Standard, hot plug Redundant Power Supply Optional, hot plug Power Supply 2-4 x 850 Watt 80 PLUS® Gold certified hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) (Max. Config, Operating) 916 VA / 903 Watt 951 VA / 938 Watt 972 VA / 958 Watt 2,290 VA / 2,240 Watt 2,350 VA / 2,300 Watt 2,430 VA / 2,383 Watt Acoustical Noise Max. Config, Idling (Sound Pressure Max. Config, Operating 3 Level) Dimensions (W x D x H ) 55.8 dB Weight (Minimum / Maximum) 39 kg / 56 kg, 85.98 lbs. / 123.46 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, BSMI, UL, CB, RoHS, WEEE Operating Systems Microsoft® Windows Server® 2003 R2, Standard Edition Microsoft® Windows Server® 2003 R2, Enterprise Edition Microsoft® Windows Server® 2003 R2, Standard x64 Edition Microsoft® Windows Server 2003 R2, Enterprise x64 Edition Microsoft® Windows Server® 2008 Standard Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise 4 Red Hat Enterprise Linux Advanced Platform5.5 or later (x86) 4 Red Hat Enterprise Linux Advanced Platform5.5 or later (EM64T) 4 Red Hat Enterprise Linux 6.0 or later (x86) 4 Red Hat Enterprise Linux 6.0 or later (x86_64) VMware ESXi 4.1 1 2 55.8 dB 483.0 x 757.0 x 176 mm / 19.0 x29.8 x 6.9 in (4U) Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html NEC Corporation Revision 8.2, October 2011 4 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 External Views Front and Rear Views Front View A B C D E F G H I J K LM ID 1 2 3 4 ID N O P Q R Legend A. Data LAN 1 Activity LED J. Power LED B. Data LAN 2 Activity LED K. Power Button System Reset Switch C. Data LAN 3 Activity LED L. D. Data LAN 4 Activity LED M. Dump (NMI) Switch E. UID LED Button N. 5-inch Media Bay F. UID LED O. Optical Drive Bay G. Hard Drive Activity LED P. Drive Bays H. System Status LED Q. VGA Connector I. Fan Status LED R. USB Connectors NEC Corporation Revision 8.2, October 2011 5 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Rear View A D E B C F G H I I Legend A. Management LAN Connector F. VGA Connector B. Data LAN Connectors G. Serial Port Connector C. PCI Slots H. Power Supply D. Additional PS Slots I. AC Inlet E. USB Connectors Dimensions (mm) 445.0 430.0 485.0 783.0 177.0 35.0 50.0 705.0 63.0 818.0 NEC Corporation Revision 8.2, October 2011 6 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Memory Board #4 Memory Board #5 Memory Board #6 Fan Power Supply #1 PCIe 1.1 x4 Processor #3 Fan Power Supply #2 PCIe 2.0 (x16) PCIe 2.0 x8 PCIe 2.0 x4 PCIe 1.1 x4 Processor #4 Memory Board #7 Memory Board #8 HDD Bay Fan PCIe 2.0 x4 ODD Bay #1 HDD Bay Memory Board #3 CHASSIS FRONT Media Bay #1 Processor #2 PCIe 2.0 x4 Fan Power Supply #3 PCIe 2.0 x8 Fan Memory Board #2 Fan Memory Board #1 Fan IO Riser Processor #1 PCIe 2.0 x8 PCIe 2.0 x8 Legend: NEC Corporation PCIe 2.0 RAID Fan Power Supply #4 CHASSIS REAR HDD Bay Configuration Diagram BBU slot #1 / #2 Minimum required components Revision 8.2, October 2011 Standard components 7 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Server Configuration 1 Base Models Product Name / Description Part Number NEC EXPRESS5800/R140b-4 Server no Processor, no RAM, no 2.5-inch HDD, no ODD Including: 2 x Memory Boards, 2x Power Units, 2.5-inch HDD Cage, EXPRESSBUILDER DVD, Slide Rail N8100-1601F 2 Processor Available sockets: 4 Product Name / Description Part Number CPU Kit (4C/E7520) 2 x Intel® Xeon ® Processor E7520 (1.86 GHz / 4C-8T / 18 MB) CPU Kit (6C/E7530) 2 x Intel® Xeon® Processor E7530 (1.86 GHz / 6C-12T / 12 MB) CPU Kit (8C/X7560) 2 x Intel® Xeon® Processor X7560 (2.26 GHz / 8C-16T / 24 MB) N8101-449F N8101-450F N8101-451F NOTE: Minimum one CPU kit must be installed. All processors must be identical. Xeon E7530 and Xeon X7560 are not available in Red Hat Linux 5 operating systems. 3 Memory 3.1 Memory Board Available boards: 8 Product Name / Description Part Number Memory Board 2 x Memory Board, for 1st and 2nd processor Additional Memory Board 2 x Memory Board (Standard) N8102-345F NOTE: Minimum one memory board per processor must be installed and up to two memory boards can be installed per processor. An optional power unit may need to be installed according to the number of memory boards and power supply configuration. Refer to Required Optional Power Units for Redundant Configuration. NEC Corporation Revision 8.2, October 2011 8 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Available DIMM Slots See the table below for the number of DIMM slots available according to the number of processors and memory boards. Number of Processors Number of Memory Boards DIMM Slots Available Ref. Maximum Memory Capacity 2 2 16 128 GB (16 x 8 GB) 4 32 256 GB (32 x 8 GB) 4 32 256 GB (32 x 8 GB) 8 64 512 GB (64 x 8 GB) 4 3.2 Memory Kit Available slots: 8 per memory board Product Name / Description Part Number Additional 2GB Memory Module (2x 1GB) 2 GB (2 x 1 GB) DDR3-1066 ECC Registered DIMM Additional 4GB Memory Module (2x 2GB) 4 GB (2 x 2 GB) DDR3-1066 ECC Registered DIMM Additional 8GB Memory Module (2x 4GB) 8 GB (2 x 4 GB) DDR3-1066 ECC Registered DIMM Additional 16GB Memory Module (2x 8GB) 16 GB (2 x 8 GB) DDR3-1066 ECC Registered DIMM N8102-346F N8102-347F N8102-348F N8102-349F NOTE: Minimum one memory kit per memory board must be installed. Memory Configuration Feature Comparison See the table below for feature comparisons of memory configurations supported. Independent Channel Memory Sparing Memory Mirroring Performance Best Better Good Data Protection No Multiple single bit error protection Multiple single bit and multi bit error protection Data Correction ECC, x4 SDDC, x8 SDDC ECC, x4 SDDC, x8 SDDC ECC, x4 SDDC, x8 SDDC Redundancy No Partly Fully Available Memory Full physical memory Physical memory excluding spare memory Half physical memory Notes - All DIMMs in the system must be identical. Paired DIMMs must be identical. NEC Corporation Revision 8.2, October 2011 9 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. 1 Maximum Memory Size Supported by OS Maximum Available Memory 4 GB Microsoft Windows Server 2003 R2, Standard Edition Microsoft Windows Server 2008 Standard 4 GB (HW-DEP enabled) App. 3.3 GB (HW-DEP disabled) 32 GB Microsoft Windows Server 2003 R2, Standard x64 Edition Microsoft Windows Server 2008 Standard (x64) Microsoft Windows Server 2008 R2 Standard (x64) 32 GB 64 GB Microsoft Windows Server 2003 R2, Enterprise Edition Microsoft Windows Server 2008 Enterprise 64 GB 1 TB Microsoft Windows Server 2003 R2, Enterprise x64 Edition 512 GB 2 TB Microsoft Windows Server 2008 Enterprise (x64) Microsoft Windows Server 2008 R2 Enterprise (x64) 512 GB 16 GB Red Hat Enterprise Linux 5 Advanced Platform 16 GB 256 GB Red Hat Enterprise Linux 5 Advanced Platform (EM64T) 256 GB 256 GB 1 or 1TB VMware ESXi 4.1 256 GB or 512 GB Up to 255 GB of main memory is available to each virtual machine. 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your RAID configuration. Available Disk RAID 0/1/10 256MB Cache Refer to 4.2.1 SAS, SATA, SSD RAID 5/6/50 256MB Cache Refer to 4.2.2 SAS, SATA, SSD 512MB Cache Refer to 4.2.3 SAS, SATA, SSD NOTE: An optional RAID controller occupies one PCI slot. All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate groups of HDD Cages. Group #3 NEC Corporation Group #2 Revision 8.2, October 2011 Group #1 10 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 4.2 Internal Drive Configuration 4.2.1 2.5-inch Drives with RAID 0/1 Controller with 256 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (256MB, RAID 0/1) LSI MegaRAID SAS 9264-8i RAID 0/1, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s, LP / FH RAID Battery Backup Unit for LSI MegaRAID SAS 9264 Internal SAS/SATA Cable 1 x mini-SAS to 1 x mini-SAS, 2 sets 2.5-inch HDD Cage 8 x 2.5-inch hot plug hard drive bays 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 450GB HDD 1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 600GB HDD 1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 73.2GB HDD 1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 300GB HDD 1 x 300GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 160GB HDD 1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm 500GB HDD 1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm 1TB HDD 1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm 100GB SSD 1 x 100 GB, 2.5-inch, SATA2 N8103-129 RAID BBU Recommended Cable HDD Cage HDD 8 slots available SAS SATA SSD N8103-124 (Standard) (Standard) N8150-306 N8150-307 N8150-321 N8150-318 N8150-330 N8150-308 N8150-309 N8150-329 N8150-319 N8150-320 N8150-333 N8150-706 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate groups of HDD Cages. NEC Corporation Revision 8.2, October 2011 11 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 4.2.2 2.5-inch Drives with RAID 5/6 Controller with 256 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (256MB, RAID 0/1/5/6) LSI MegaRAID SAS 9264-8i RAID 0/1/5/6, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s, LP / FH RAID Battery Backup Unit for LSI MegaRAID SAS 9264 Internal SAS/SATA Cable 1 x mini-SAS to 1 x mini-SAS, 2 sets 2.5-inch HDD Cage 8 x 2.5-inch hot plug hard drive bays 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 450GB HDD 1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 600GB HDD 1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 73.2GB HDD 1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 300GB HDD 1 x 300GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 160GB HDD 1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm 500GB HDD 1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm 1TB HDD 1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm 100GB SSD 1 x 100 GB, 2.5-inch, SATA2 N8103-130 RAID BBU Recommended Cable HDD Cage HDD 8 slots available SAS SATA SSD N8103-124 (Standard) (Standard) N8150-306 N8150-307 N8150-321 N8150-318 N8150-330 N8150-308 N8150-309 N8150-329 N8150-319 N8150-320 N8150-333 N8150-706 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate groups of HDD Cages. NEC Corporation Revision 8.2, October 2011 12 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 4.2.3 2.5-inch Drives with RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID0/1/5/6) Promise SuperTrak EX8760T-512 RAID 0/1/5/6, 512MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s, LP / FH RAID Battery Backup Unit for Promise SuperTrak EX8760T and EX8768 Internal SAS/SATA Cable 1 x mini-SAS to 1 x mini-SAS, 2 sets 2.5-inch HDD Cage 8 x 2.5-inch hot plug hard drive bays 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 450GB HDD 1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 600GB HDD 1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 73.2GB HDD 1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 300GB HDD 1 x 300GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 160GB HDD 1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm 500GB HDD 1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm 1TB HDD 1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm 100GB SSD 1 x 100 GB, 2.5-inch, SATA2 N8103-134 RAID BBU Recommended Cable HDD Cage HDD 8 slots available SAS SATA SSD N8103-136 (Standard) (Standard) N8150-306 N8150-307 N8150-321 N8150-318 N8150-330 N8150-308 N8150-309 N8150-329 N8150-319 N8150-320 N8150-333 N8150-706 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate groups of HDD Cages. NEC Corporation Revision 8.2, October 2011 13 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 5 Optical Drive Category Product Name / Description Part Number Internal 1 slot available Internal Slim DVD-ROM drive Slim DVD-ROM drive Internal DVD Super Multi Drive Slim DVD Super Multi drive, not including writing software External DVD-ROM drive Slim DVD-ROM drive, Bus powered, 0.8 A required N8151-100 External N8151-104F N8160-85 NOTE: Up to 1 optical drive can be connected. 6 Internal Tape / RDX Drives 6.1 Tape / RDX Drive Selection Refer to the section in accordance with your type of tape drives. DAT DAT72 USB Refer to 6.2.1 DAT160 USB Refer to 6.2.1 DAT320 USB Refer to 6.2.1 USB Refer to 6.2.2 LTO2 SAS Refer to 6.2.3 LTO3 SAS Refer to 6.2.3 LTO4 SAS Refer to 6.2.3 LTO5 SAS Refer to 6.2.4 RDX LTO NOTE: Tape devices cannot be directly connected to VMware ESXi servers. For an ESXi environment, it is recommended to connect and configure an additional backup server via network. NEC Corporation Revision 8.2, October 2011 14 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 6.2 Tape / RDX Configuration 6.2.1 DAT / USB Category Product Name / Description Part Number Controller Internal USB Controller 1 x USB port Internal USB cable 1 x Internal USB to 1 x USB device (Standard) Internal DAT (USB) DDS3 / DDS4 / DAT72, Native capacity 36 GB NOTE: DDS1 / DDS2 format are not supported. N8151-69 Internal DAT (USB) DDS4 / DAT72 / DAT160, Native capacity 80 GB NOTE: DDS1 / DDS2 / DDS3 format are not supported. N8151-78 Internal DAT (USB) DAT72 / DAT160 / DAT 320, Native capacity 160 GB NOTE: DDS1 / DDS2 / DDS3 / DDS4 / DAT7 2 /DAT160 for WORM format are not supported. N8151-99 Category Product Name / Description Part Number Controller Internal USB Controller 1 x USB port Internal USB cable 1 x Internal USB to 1 x USB device (Standard) Internal RDX (USB) N8151-86 Cable Drive 1 bay available 6.2.2 RDX Cable Drive 1 bay available 6.2.3 K410-161(00) K410-161(00) LTO / SAS (1) Category Product Name / Description Part Number Controller Required SAS Controller LSI SAS3442E-R Host Bus Adapter 3Gbps SAS, Int. 4, Ext. 4, SFF-8484 / SFF8470, PCIe x8, LP/FH N8103-104A Cable Required Drive 1 bay available Internal SAS Cable 1x SFF-8484 SAS to 2x SFF-8482 SAS Internal LTO (SAS) LTO2, Half height, Native capacity 200 GB Internal LTO (SAS) LTO3, Half height, Native capacity 400 GB Internal LTO (SAS) LTO4, Half height, Native capacity 800 GB K410-173(00) N8151-101 N8151-102 N8151-90 NOTE: SAS Controller needs to be installed in PCI slots from #8 to #10 to connect with the LTO4 drive. NEC Corporation Revision 8.2, October 2011 15 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 6.2.4 LTO / SAS (2) Category Product Name / Description Part Number Controller Required SAS Controller LSI ISAS9212-4i4 Host Bus Adapter 6Gbps SAS, Int. 4, Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8, LP/FH Internal SAS Cable N8103-142 Cable Required K410-217(00) 1x 7-pin Single SATA to 1x SFF-8482 SAS Drive 1 bay available Internal LTO (SAS) N8151-103 LTO5, Half height, Native capacity 1.5 TB NOTE: SAS Controller needs to be installed in PCI slots from #8 to #10 to connect with the LTO5 drive. 7 PCI Card 7.1 LAN Controller Category GbE 10GbE PCIe Ctrlr Module Product Name / Description Part Number 1000BASE-T Adapter Intel® PRO/1000 PT Server Adapter PCIe x1, LP / FH 1000BASE-T Adapter (2ch) Intel® PRO/1000 PT Dual Port Server Adapter PCIe x4, FH 1000BASE-T Adapter (4ch) Intel® PRO/1000 PT Quad Port Server Adapter PCIe x8, LP / FH, maximum 5 per system NOTE: - Network cables with RJ-45 plug covers cannot be used. - Installable PCI slots depends on number of N8104-125A installed. Refer to Available PCI Slots with N8104-125A 1000BASE-TX. N8104-126 10GBASE-SR Adapter Chelsio S310E-SR 10GbE Storage Accelerator PCIe x8, LP / FH, maximum 2 per system 10GBASE Adapter (SFP+/2ch) Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8, LP / FH NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to 2 SFP+ Modules can be installed. - On Windows Server 2003R2 /2008 / 2008R2 and Red Hat Linux 5.x(EM64T) and 6.x(x86_64) operating systems, teaming and bonding features across one or two identical adapters are supported. A team can include up to two ports and up to two teams per system are allowed. - On Red Hat Linux 5.x(x86) and 6.x(x86) operating systems, bonding features within one adapter with up to two ports are supported. One team per system is allowed. N8104-123A SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-128 N8104-129 N8104-121 N8104-125A N8104-128 NOTE: Teaming and bonding features across the standard LAN and optional PCIe based GbE LAN controller (excluding N8104-126) are supported on Windows Server 2003R2 /2008 / 2008R2 and Red Hat Linux NEC Corporation Revision 8.2, October 2011 16 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 5.x operating systems. Teaming feature is not supported on iSCSI interfaces. Available PCI Slots with N8104-125A 1000BASE-TX See the table below for the number of PCI slots available according to the number of N8104-125A 4ch 1000BASE-T Adapters installed. Number of Adapters Available PCI Slots excluding RAID Slot 0 10 1 8 2 6 3 4 4 2 5 0 7.2 External RAID Controller Category Product Name / Description Part Number Controller RAID Controller (512MB, RAID0/1/5/6) Promise SuperTrak EX8768 RAID 0/1/5/6, 512MB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s, LP / FH, maximum 3 per system RAID Battery Backup Unit for Promise SuperTrak EX8760T and EX8768 N8103-135 RAID BBU 7.3 N8103-136 Fibre Channel / SAS / SCSI Controller Category Product Name / Description Part Number Fibre Channel Fibre Channel Controller (1ch) Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8, LP / FH Fibre Channel Controller (2ch) Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8, LP / FH Fibre Channel Controller (1ch) Emulex LightPulse LPe1150-F4 Host Bus Adapter 4Gb/s, Optical, PCIe x4, LP / FH Fibre Channel Controller (2ch) Emulex LightPulse LPe11002-M4 Host Bus Adapter 4Gb/s, Optical, PCIe 2.0 x4, LP / FH SCSI Controller Adaptec SCSI Card 29320LPE 1-channel U320, 68-pin D-sub / 68-pin VHDC, PCIe x1, LP/FH, maximum 3 per system SAS Controller LSI SAS3442E-R Host Bus Adapter 3Gb/s SAS, Int. 4 / Ext. 4, SFF-8484 / SFF8470, PCIe x8, LP/FH SAS Controller LSI SAS9212-4i4 Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8, LP/FH N8190-153 SCSI SAS NEC Corporation Revision 8.2, October 2011 N8190-154 N8190-127 N8190-131 N8103-107 N8103-104A N8103-142 17 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 7.4 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter Serial port fixed to PCI bracket N8117-01A 8 Other Add-in Components 8.1 Redundant Power Supply Available Slots: 2 Product Name / Description Part Number Power Unit 1 x 850 Watt 80 PLUS® Gold certified Hot plug Power Supply N8181-68F Required Optional Power Units for Redundant Configuration See the table below for the number of optional power units required according to the number of memory boards and power supply configuration. Number of Memory Boards Power Supply Configuration Number of Optional Power Units 2 Non-redundant 0 2 + 1 redundancy 1 2 + 2 redundancy 2 Non-redundant 0 2 + 1 redundancy 1 2 + 2 redundancy 2 Non-redundant 1 3 + 1 redundancy 2 4 8 8.2 VMware ESXi Pre-install Kit Product Name / Description Part Number VMware ESXi 4.1 Base Kit Including USB flash memory, VMware ESXi 4.1 Recovery CD NOTE: The Base Kit may not be available in some regions. Please contact our sales representative to confirm if it is available in your country. The Base Kit must be ordered with the base model. Installation of VMware ESXi onto hard drives is not supported. N8106-006F NEC Corporation Revision 8.2, October 2011 18 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 9 Add-on Components 9.1 17-inch LCD Console Drawer Category Drawer Drawer w/ KVM Cable Drawer Drawer w/o KVM 9.2 Product Name / Description Part Number 17inch LCD Console Unit (1U/8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-Sub to 1 x 15-pin mini D-Sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-Sub to 1 x 15-pin mini D-Sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-Sub to 1 x 15-pin mini D-Sub / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2m N8143-69F K410-118(1A) K410-118(03) K410-118(05) N8143-76F KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-Sub to 1 x 15-pin mini D-Sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-Sub to 1 x 15-pin mini D-Sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,5m) 5 m, 1 x 15-pin mini D-Sub to 1 x 15-pin mini D-Sub / 1 x 4-pin USB A N8191-10F Cable 9.3 K410-118(1A) K410-118(03) K410-118(05) Server Management License The server integrates the EXPRESSSCOPE Engine 2 as standard. Refer to Server Management (References) for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit N8115-03 License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC / server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC / server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. NEC Corporation Revision 8.2, October 2011 19 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 9.4 Front Bezel Product Name / Description Part Number Front Bezel Front bezel for R140b-4 N8146-15F 9.5 Flash FDD Choose the Flash FDD if you need to prepare an alternative for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-86 9.6 Medium and Cartridge Category Product Name Drive supported Part Number RDX RDX Cartridge (160GB) N8151-86 N8152-20 RDX Cartridge (320GB) N8151-86 N8152-26 RDX Cartridge (500GB) N8151-86 N8152-27 RDX Cartridge (640GB) N8151-86 N8152-30 RDX Cartridge (1TB) N8151-86 N8152-33 10 Support Service 10.1 Software Product Name / Description Part Number PP Support Pack (VMware ESXi 4.1 for 1 processor)(1year) Technical Support Service regarding ESXi (for quick solutions to technical issues) NOTE: It is necessary to purchase a PP support pack for each processor installed in the system. ULH1S-SV40-008F NEC Corporation Revision 8.2, October 2011 20 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 References Server Management The EXPRESSSCOPE Engine 2, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring Temperature/voltage/power/ fan /degeneration (memory/hard drive) Hardware event log collection With Remote KVM and Media License Kit 1 Boot monitoring Booting, BIOS/POST stall, OS stall, shutdown Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote KVM POST/BIOS setup, DOS utility 2 2 Text-based screen (OS console) 2 (via LAN) Panic screen, Boot screen GUI-based screen (OS console) - Remote control Remote reset/power on-off/ dump (via LAN) OS shutdown Remote media (CD/DVD/FD) - Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch 1 1 Scheduling (without UPS) Others Set automatic IP address via DNS/DHCP Remote wakeup Wake On LAN, Wake On Ring Centralized management Industry standard 1 2 1 1 1 1 Monitoring and control of multiple servers IPMI 2.0 1 2.0 The feature is not supported on VMware ESXi systems. The standard serial port is not available for the feature. NEC Corporation Revision 8.2, October 2011 21 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 OS Support Matrix for PCI Cards ESXi 4.1 RHEL 5 RHEL 6 WS 2003R2 x64 WS 2003R2 WS 2008 x64 WS 2008 WS 2008R2 Part Number Product Name N8104-126 1000BASE-T Adapter N8104-121 1000BASE-T Adapter (2ch) N8104-125A 1000BASE-T Adapter (4ch) N8104-123A 10GBASE-SR Adapter - N8104-128 10GBASE Adapter (SFP+/2ch) - N8103-129 RAID Controller N8103-130 RAID Controller N8103-134 RAID Controller N8103-135 RAID Controller N8103-107 SCSI Controller - - N8103-104A SAS Controller, 3 Gb/s - - N8103-142 SAS Controller, 6 Gb/s - - N8190-153 Fibre Channel Controller - N8190-154 Fibre Channel Controller (2ch) - N8190-127 Fibre Channel Controller - N8190-131 Fibre Channel Controller (2ch) - NEC Corporation - - Revision 8.2, October 2011 - - - 22 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Supporting PCI Cards and Installable Slots Part Number Product Name Slots Slot # : #0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 PCI Slot: x8 x8 x8 x4 x4 x16 x8 x8 x4 x4 x4 Card height: FH Slot type: x8 x8 x8 x8 x8 x16 x8 x8 x8 x8 x8 Installable card length (mm) : - 234 234 167 167 234 234 234 234 167 167 N8103-129 RAID Controller (256MB, RAID 0/1) [PCIe 2.0 x8] - - - - - - - - - - N8103-130 RAID Controller (256MB, RAID 0/1/5/6) [PCIe 2.0 x8] - - - - - - - - - - N8103-134 RAID Controller (512MB,RAID 0/1/5/6) [PCIe 2.0 x8] - - - - - - - - - - N8103-135 RAID Controller (512MB,RAID 0/1/5/6) [PCIe 2.0 x8] - - - N8103-107 SCSI Controller [PCIe x1] - - - - - - N8103-104A SAS Controller [PCIe x8] - - - - - - N8103-142 SAS Controller [PCIe 2.0 x8] - - - - - - N8190-127 Fibre Channel Controller [PCIe x4] - - - N8190-131 Fibre Channel Controller (2ch) [PCIe x4] - - - N8190-153 Fibre Channel Controller [PCIe 2.0 x8] - - - N8190-154 Fibre Channel Controller (2ch) [PCIe 2.0 x8] - - - N8104-126 1000BASE-T adapter [PCIe x1] - - - - - - N8104-121 1000BASE-T Adapter (2ch) [PCIe x4] - - - - N8104-125A 1000BASE-T Adapter (4ch) [PCIe x4] - - - N8104-123A 10GBASE-SR Adapter [PCIe x8] - - - - - - N8104-128 10GBASE adapter (SFP+/2ch) [PCIe 2.0 x8] - - - - - - N8117-01A Serial Port Adapter - - - - - - - - - - NEC Corporation Revision 8.2, October 2011 23 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 8.2, October 2011 24 CONFIGURATION GUIDE – NEC EXPRESS5800/R140b-4 Revision History Revision Date Description 8.2 October 18, 2011 Others: Correct incorrect information in Specification, 2 Processor, 9.1 17-inch LCD Console Drawer and 9.2 KVM Switch. 8.1 September 1st, 2011 Others: Correct memory speed description in Key Features section 8.0 July 29th, 2011 New products added: 300GB 15K 2.5-inch SAS HDD / N8150-331 900GB 10K 2.5-inch SAS HDD / N8150-332 Discontinued products removed: SCSI Controller / N8103-75 100BASE-TX Adapter / N8104-111 Others: Change part number for CPU kit and memory options 7.0 June 6th, 2011 New product added: Internal DVD Super Multi Drive / N8151-104F 6.0 April 8th, 2011 New products added: 1TB 7.2K 2.5-inch SATA HDD / N8150-334 5.0 February 16th, 2011 New products added: SAS Controller / N8103-142 100GB 2.5-inch SSD / N8150-706 1TB RDX Cartridge / N8152-33 Discontinued products removed: 50GB 2.5-inch SSD / N8150-331 4.0 November 30th, 2010 Discontinued products removed: External FDD / N8160-81 3.0 October 25th, 2010 New products added: 17 inch LCD console unit / N8143-76F 640GB RDX Cartridge / N8152-30 2.0 September 1st, 2010 New products added: VMware ESXi 4.1 Support Kit / N8106-006F 1.0 April 26th, 2010 Initial release NEC Corporation Revision 8.2, October 2011 25