NEC Express5800/E120b-1 Configuration Guide Consolidated Power Supply model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. November 8, 2012 Revision 9.0 NEC Corporation CONFIGURATION GUIDE – NEC EXPRESS5800/E120b-1 / Consolidated Power Supply Model Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 5 Front and Rear Views ........................................................................................................................... 5 Dimensions (mm) .................................................................................................................................. 6 CONFIGURATION DIAGRAM ......................................................................................... 7 SERVER CONFIGURATION ........................................................................................... 8 1 2 3 4 5 6 7 8 Base Models ................................................................................................................................... 8 2nd Processor ................................................................................................................................ 8 Memory ........................................................................................................................................... 8 Internal Hard Disk Drives ............................................................................................................ 10 4.1 RAID Configuration .............................................................................................................. 10 4.2 Internal Drive Configuration ................................................................................................. 11 PCI Card ........................................................................................................................................ 16 5.1 Network Interface Controller ................................................................................................ 16 5.2 External RAID Controller ..................................................................................................... 17 5.3 Fibre Channel / SAS Controller ........................................................................................... 17 5.4 Serial Port Adapter .............................................................................................................. 17 Other Add-in Components .......................................................................................................... 17 6.1 VMware ESXi Pre-install Kit ................................................................................................ 17 Add-on Components ................................................................................................................... 18 7.1 17-inch LCD Console Drawer .............................................................................................. 18 7.2 KVM Switch ......................................................................................................................... 18 7.3 Server Management License............................................................................................... 19 7.4 Flash FDD............................................................................................................................ 19 7.5 Optical Drive ........................................................................................................................ 19 Support Service ........................................................................................................................... 19 8.1 Software............................................................................................................................... 19 REFERENCES............................................................................................................... 20 Note for Ordering ................................................................................................................................ 20 Server Management ............................................................................................................................ 20 OS Support Matrix for PCI Cards ...................................................................................................... 21 Tested Operating System List............................................................................................................ 21 Supporting PCI Cards and Installable Slots ..................................................................................... 22 Copyright Notice and Liability Disclaimer ........................................................................................ 23 REVISION HISTORY ..................................................................................................... 24 NEC Corporation Revision 9.0, November 8, 2012 2 CONFIGURATION GUIDE – NEC EXPRESS5800/E120b-1 / Consolidated Power Supply Model Technical Specification Key Features High performance with the latest Intel® Xeon® processor 5600 series Up to 64 GB of high speed DDR3-1333 memory High energy efficiency with intelligent fan control, power capping feature and 80PLUS® Gold power supply Full manageability by integrated EXPRESSSCOPE Engine 2 Specification Model E120b-1 Part Number N8100-1627F N8100-1689F Type Intel® Xeon® Processor L5630 Intel® Xeon® Processor L5640 Clock Speed 2.13 GHz 2.26 GHz Number of Processor 1 or 2 Cache 12 MB Cores and Threads 4C-8T Processor Chipset Memory Internal Storage 6C-12T Intel® 5500 chipset Type DDR3-1333 ECC Unbuffered and Registered Low Power DIMM Standard Capacity 0 GB Maximum Capacity 64 GB (8 x 8 GB) Memory protection ECC, x4 SDDC Standard Capacity 0 GB Maximum Capacity SAS : 7.2 TB (8 x 900 GB) SATA : 8 TB (8 x 1 TB) Disk Controller SATA : 3 Gb/s (Integrated) SAS : 6 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard), RAID 5/6/50 (Optional) SAS : RAID 0/1/5/6/10/50 (Optional) Hot Plug Supported Optical Disk Drive Optional (External drive) Optical Drive Bays [free] Disk Drive Bays [free] 0 [0] 1 2 8 [8] Expansion Slots [free] Total: 2 slots available 1 [1] x PCIe 2.0 x8 (x16 connector) 1 [1] x PCIe 2.0 x8 (x8 connector) Video Controller (VRAM) Integrated in Server Management Controller (32MB) Interfaces 2 x VGA (15-pin mini D-sub, 1x front, 1x rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2rear) 8x USB2.0 (2 x front, 4 x rear, 2 x internal) 2x 1000BASE-T LAN connector (1000BASE-T / 100BASE-TX / 10BASE-T, RJ-45, 2 x rear) 1 x Management LAN connector (100BASE-TX / 10BASE-T, RJ-45, 1 x rear) Server Management EXPRESSSCOPE Engine 2 System Fan Standard Power Supply - NEC Corporation Revision 9.0, November 8, 2012 3 CONFIGURATION GUIDE – NEC EXPRESS5800/E120b-1 / Consolidated Power Supply Model Model Power Consumption E120b-1 (Max. Config, Idling) 159 Watt 160 Watt (Max. Config, Operating) Idling 244 Watt 295 Watt Acoustical Noise (Sound Pressure Operating 3 Level) Dimensions (W x D x H ) 51.3 dB Weight (Minimum / Maximum) 11 kg / 16 kg, 24.25 lbs. / 35.27 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE Operating Systems Microsoft® Windows Server® 2003 R2, Standard Edition Microsoft® Windows Server® 2003 R2, Enterprise Edition Microsoft® Windows Server® 2003 R2, Standard x64 Edition Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition Microsoft® Windows Server® 2008 Standard Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise 4 Red Hat Enterprise Linux 4.8 or later 4 Red Hat Enterprise Linux 4.8 or later (EM64T) 4 Red Hat Enterprise Linux 5.5 or later 4 Red Hat Enterprise Linux 5.5 or later (EM64T) 4 Red Hat Enterprise Linux 6.0 or later (x86) 4 Red Hat Enterprise Linux 6.0 or later (x86_64) VMware ESXi 4.1 1 2 3 4 54.9 dB 444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U) x4 SDDC is supported with Registered DIMM only. On-board SATA RAID controller is supported only on Windows operating systems Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html NEC Corporation Revision 9.0, November 8, 2012 4 External Views Front and Rear Views Front View B A H CD E F G I J KLM N Legend A. VGA Connector H. Power Button B. USB Connectors I. Pull-out Tab C. Power LED J. Drive Bays D. Data LAN 1 Activity LED K. Hard Drive Activity LED E. UID LED L. Data LAN 2 Activity LED F. BMC Reset Switch M. System Status LED G. UID LED Button N. Dump (NMI) Switch Rear View A B C G D H E I F J K Legend A. DC Inlet G. VGA Connector B. DC Power LED H. System Power LED C. Serial Port Connector I. USB Connectors Management LAN Connector UID LED / Button D. Data LAN 1 Connector J. E. Data LAN 2 Connector K. F. PCI Slots NEC Corporation Revision 9.0, November 8, 2012 5 Dimensions (mm) 44.3 653.0 615.2 444.0 NEC Corporation Revision 9.0, November 8, 2012 482.0 43.6 6 BBU slot #1 #1 #2 #3 #4 Processor #1 BBU slot #2 Processor #2 DIMM DIMM DIMM DIMM #5 #6 #7 #8 PCIe 2.0 x8 (x16 socket) LP/MD2 PCIe 2.0 x8 (x8 socket) LP/MD2 Legend: NEC Corporation Minimum requirement components Revision 9.0, November 8, 2012 HDD Bay HDD Bay DIMM DIMM DIMM DIMM HDD Bay DC-DC Converter CHASSIS FRONT HDD Bay HDD Bay 2.5-inch HDD Cage HDD Bay CHASSIS REAR HDD Bay HDD Bay Configuration Diagram Standard components 7 Server Configuration 1 Base Models Product Name / Description Part Number NEC EXPRESS5800/E120b-1 Server no RAM, no 2.5-inch HDD Including: 1 x Intel Xeon L5630, 2.5-inch HDD Cage, EXPRESSBUILDER DVD NEC EXPRESS5800/E120b-1 Server no RAM, no 2.5-inch HDD Including: 1 x Intel Xeon L5640, 2.5-inch HDD Cage, EXPRESSBUILDER DVD N8100-1627F N8100-1682F NOTE: N8142-36F Consolidated PSU is required for supplying DC powers. Refer to the configuration guide for Consolidated PSU. 2 2nd Processor Available sockets: 1 Product Name / Description Part Number CPU Kit (4C/L5630) Intel® Xeon® Processor L5630 (2.13 GHz / 4C-8T / 12 MB) CPU Kit (4C/L5640) Intel® Xeon® Processor L5640 (2.26 GHz / 6C-12T / 12 MB) N8101-477 N8101-478 NOTE: The 2nd processor must be the same with what is used in the base model 3 Memory Available slots: 4 per processor Product Name / Description Part Number 2GB Memory Kit 2GB (1x 2 GB) DDR3-1333 ECC Unbuffered DIMM 4GB Memory Kit 4GB (1x 4 GB) DDR3-1333 ECC Unbuffered DIMM 8GB Memory Kit 8GB (1x 8 GB) DDR3-1333 ECC Registered DIMM N8102-413 N8102-414 N8102-411 NOTE: Minimum one memory kit per processor must be installed. It is recommended to install two identical memory kits for dual-channel symmetric configuration to increase memory transfer speed. Mixing unbuffered and registered DIMM in the same system is not supported. Actual DIMM speed is set to 1066 MHz when you choose Xeon L5630 Processor. NEC Corporation Revision 9.0, November 8, 2012 8 Maximum Memory Speed See the table below for the actual maximum memory speed on your system. DDR3 memory speed depends on memory power setting and the native memory bus speed of the memory controller. All memory buses operate at the clock frequency of the DIMM with the lowest frequency. Memory Power Setting Processor Type DIMMs per Channel DIMM Speed L5630 - - 1066 MHz L5640 Normal (1.5V) - 1333 MHz Low (1.35V) 1 1333 MHz 2 1066 MHz Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. 1 Maximum Memory Size Supported by OS Maximum Available Memory 4 GB Microsoft Windows Server 2003 R2, Standard Edition Microsoft Windows Server 2008 Standard 4 GB (HW-DEP enabled) App. 3.3 GB (HW-DEP disabled) 32 GB Microsoft Windows Server 2003 R2, Standard x64 Edition Microsoft Windows Server 2008 Standard (x64) Microsoft Windows Server 2008 R2 Standard (x64) 32 GB 64 GB Microsoft Windows Server 2003 R2, Enterprise Edition Microsoft Windows Server 2008 Enterprise 64 GB 1 TB Microsoft Windows Server 2003 R2, Enterprise x64 Edition 64 GB 2 TB Microsoft Windows Server 2008 Enterprise (x64) Microsoft Windows Server 2008 R2 Enterprise (x64) 64 GB 16 GB Red Hat Enterprise Linux ES4 Red Hat Enterprise Linux ES4 (EM64T) Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 5 Advanced Platform Red Hat Enterprise Linux 6 16 GB 64 GB Red Hat Enterprise Linux AS4 64 GB 256 GB Red Hat Enterprise Linux AS4 (EM64T) Red Hat Enterprise Linux 5 (EM64T) Red Hat Enterprise Linux 5 Advanced Platform (EM64T) 64 GB 256 GB 1 or 1TB VMware ESXi 4.1 64 GB Up to 255 GB of main memory is available to each virtual machine. NEC Corporation Revision 9.0, November 8, 2012 9 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration. Available Disk Non-RAID Refer to 4.2.1 SATA 128MB Cache Refer to 4.2.2 SAS, SATA 256MB Cache Refer to 4.2.3 SAS, SATA 256MB Cache Refer to 4.2.4 SAS, SATA 512MB Cache Refer to 4.2.5 SAS, SATA On-board SATA RAID RAID 0/1 Optional RAID Controller RAID 5/6 NOTE: On-board SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. Hot plug insertion/removal is not supported with the on-board SATA non-RAID controller.. All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate group of HDD Cages. Group #1 Group #2 Group #3 Group #4 An optional RAID controller occupies one PCI slot. NEC Corporation Revision 9.0, November 8, 2012 10 4.2 Internal Drive Configuration 4.2.1 On-board SATA Controller Category Product Name / Description Part Number Storage Controller On-board SATA Controller 6 x SATA ports, RAID 0/1/10 capable Internal SAS/SATA Cable 1x mini-SAS to 4x single SATA, 2set 2.5-inch HDD Cage 8 x 2.5-inch hot plug hard drive bays 160GB HDD 1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm 500GB HDD 1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm 1TB HDD 1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm (Standard) Cable HDD Cage HDD 6 slots available SATA (Standard) (Standard) N8150-276 N8150-277 N8150-334 NOTE On-board SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. Hot plug insertion/removal is not supported with the on-board SATA non-RAID controller.. All hard drives within a RAID array should be of the same capacity and rotation speed. NEC Corporation Revision 9.0, November 8, 2012 11 4.2.2 RAID 0/1 Controller with 128 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (128MB, RAID 0/1) Promise SuperTrak TX8760T-128 RAID 0/1, 128MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s, LP / FH RAID Battery Backup Unit for Promise SuperTrak EX8760T Internal SAS/SATA Cable 1x mini-SAS to 4x single SATA, 2set 2.5-inch HDD Cage 8 x 2.5-inch hot plug hard drive bays 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 450GB HDD 1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 600GB HDD 1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 73.2GB HDD 1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 160GB HDD 1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm 500GB HDD 1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm 1TB HDD 1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm N8103-128 RAID BBU Recommended Cable HDD Cage HDD 8 slots available SAS SATA N8103-140 (Standard) (Standard) N8150-374 N8150-375 N8150-376 N8150-377 N8150-332 N8150-378 N8150-379 N8150-331 N8150-276 N8150-277 N8150-334 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate group of HDD Cages. NEC Corporation Revision 9.0, November 8, 2012 12 4.2.3 RAID 0/1 Controller with 256 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (256MB, RAID 0/1) LSI MegaRAID SAS 9264-8i RAID 0/1, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s, LP / FH RAID Battery Backup Unit for LSI MegaRAID SAS 9264 Internal SAS/SATA Cable 1x mini-SAS to 4x single SATA, 2set 2.5-inch HDD Cage 8 x 2.5-inch hot plug hard drive bays 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 450GB HDD 1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 600GB HDD 1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 73.2GB HDD 1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 160GB HDD 1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm 500GB HDD 1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm 1TB HDD 1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm N8103-129 RAID BBU Recommended Cable HDD Cage HDD 8 slots available SAS SATA N8103-123 (Standard) (Standard) N8150-374 N8150-375 N8150-376 N8150-377 N8150-332 N8150-378 N8150-379 N8150-331 N8150-276 N8150-277 N8150-334 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate group of HDD Cages. NEC Corporation Revision 9.0, November 8, 2012 13 4.2.4 RAID 5/6 Controller with 256 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (256MB, RAID 0/1/5/6) LSI MegaRAID SAS 9264-8i RAID 0/1/5/6, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s, LP / FH RAID Battery Backup Unit for LSI MegaRAID SAS 9264 Internal SAS/SATA Cable 1x mini-SAS to 4x single SATA, 2set 2.5-inch HDD Cage 8 x 2.5-inch hot plug hard drive bays 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 450GB HDD 1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 600GB HDD 1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 73.2GB HDD 1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 160GB HDD 1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm 500GB HDD 1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm 1TB HDD 1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm N8103-130 RAID BBU Recommended Cable HDD Cage HDD 8 slots available SAS SATA N8103-123 (Standard) (Standard) N8150-374 N8150-375 N8150-376 N8150-377 N8150-332 N8150-378 N8150-379 N8150-331 N8150-276 N8150-277 N8150-334 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate group of HDD Cages. NEC Corporation Revision 9.0, November 8, 2012 14 4.2.5 RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller(512MB, RAID0/1/5/6) Promise SuperTrak EX8760T-512 RAID 0/1/5/6, 512MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s, LP / FH RAID Battery Backup Unit for Promise SuperTrak EX8760T Internal SAS/SATA Cable 1x mini-SAS to 4x single SATA, 2set 2.5-inch HDD Cage 8 x 2.5-inch hot plug hard drive bays 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 450GB HDD 1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 600GB HDD 1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm 73.2GB HDD 1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 146.5GB HDD 1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 300GB HDD 1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm 160GB HDD 1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm 500GB HDD 1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm 1TB HDD 1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm N8103-134 RAID BBU Recommended Cable HDD Cage HDD 8 slots available SAS SATA N8103-140 (Standard) (Standard) N8150-374 N8150-375 N8150-376 N8150-377 N8150-332 N8150-378 N8150-379 N8150-331 N8150-276 N8150-277 N8150-334 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. SAS and SATA hard drives must be installed in separate group of HDD Cages. NEC Corporation Revision 9.0, November 8, 2012 15 5 PCI Card 5.1 Network Interface Controller Category Product Name / Description Part Number 1GbE 1000BASE-T Adapter Intel® PRO/1000 PT Server Adapter PCIe x1, LP / FH 1000BASE-T Adapter (2ch) Intel® PRO/1000 PT Dual Port Server Adapter PCIe x4, LP 1000BASE-T Adapter (4ch) Intel® PRO/1000 PT Quad Port Server Adapter PCIe x4, LP / FH NOTE: Network cables with RJ-45 plug covers cannot be used. N8104-126 10GBASE-SR Adapter Chelsio S310E-SR 10GbE Storage Accelerator PCIe x8, LP / FH 10GBASE Adapter (SFP+/2ch) Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8, LP / FH NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to 2 SFP+ Modules can be installed. - On Windows Server 2003R2 /2008 / 2008R2 and Red Hat Linux 5.x(EM64T) and 6.x(x86_64) operating systems, teaming and bonding features across one or two identical adapters are supported. A team can include up to two ports and up to two teams per system are allowed. - On Red Hat Linux 5.x(x86) and 6.x(x86) operating systems, bonding features within one adapter with up to two ports are supported. One team per system is allowed. N8104-123A SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-128 Dual Port 10Gb Converged Network Adapter BROCADE 1020 Dual Port 10Gbps Converged Network Adapter PCIe 2.0 x8, LP / FH, 2 x SFP module N8104-129 10GbE Ctrlr Module Converged Network N8104-122 N8104-125A N8104-128 N8104-131 NOTE: Teaming and bonding features across the standard LAN and optional PCIe based GbE LAN controller (excluding N8104-126) are supported on Windows Server 2003R2 /2008 / 2008R2 and Red Hat Linux 5.x and 6.x operating systems. When installing a 10GBASE-SR Adapter, no other additional 10GbE LAN controllers are allowed. Teaming feature is not supported on iSCSI interfaces. NEC Corporation Revision 9.0, November 8, 2012 16 5.2 External RAID Controller Category Product Name / Description Part Number Controller RAID Controller (512MB, RAID0/1/5/6) Promise SuperTrak EX8768 RAID 0/1/5/6, 512MB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA3Gb/s, LP / FH RAID Battery Backup Unit for Promise SuperTrak EX8760T and EX8768 N8103-135 RAID BBU 5.3 N8103-140 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Fibre Channel Controller (1ch) Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8, LP / FH Fibre Channel Controller (2ch) Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8, LP / FH Fibre Channel Controller (1ch) Emulex LightPulse LPe1150-F4 Host Bus Adapter 4Gb/s, Optical, PCIe x4, LP / FH Fibre Channel Controller (2ch) Emulex LightPulse LPe11002-M4 Host Bus Adapter 4Gb/s, Optical, PCIe 2.0 x4, LP / FH SAS Controller LSI ISAS9212-4i4 Host Bus Adapter 6Gbps SAS, Int. 4, Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8, LP/FH N8190-153 SAS 5.4 N8190-154 N8190-127 N8190-131 N8103-142 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter Serial port fixed to PCI bracket NOTE: Supports up to one adapter N8117-01A 6 Other Add-in Components 6.1 VMware ESXi Pre-install Kit Product Name / Description Part Number VMware ESXi 4.1 Base Kit Including USB flash memory, VMware ESXi 4.1 Recovery CD NOTE: The Base Kit may not be available in some regions. Please contact our sales representative to confirm if it is available in your country. The Base Kit must be ordered with the base model. Installation of VMware ESXi onto hard drives is not supported. N8106-004F NEC Corporation Revision 9.0, November 8, 2012 17 7 Add-on Components 7.1 17-inch LCD Console Drawer Category Drawer Drawer w/ KVM Cable Drawer Drawer w/o KVM Keypad 7.2 Product Name / Description Part Number 17-inch LCD Console Drawer (8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1port) N8143-77F K410-118(1A) K410-118(03) K410-118(05) N8143-76F N8143-84F N8143-85 N8143-87 KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-12F Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 K410-118(1A) Cable KVM Cascading NEC Corporation Revision 9.0, November 8, 2012 K410-118(03) K410-118(05) K410-119(1A) 18 7.3 Server Management License The server integrates the EXPRESSSCOPE Engine 2 as standard. Refer to Server Management (References) for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit N8115-03 License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. 7.4 Flash FDD Choose the Flash FDD if you need to prepare the alternative device for floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-86 NOTE: Up to one drive can be connected. 7.5 Optical Drive Product Name / Description Part Number External DVD-ROM drive Slim DVD-ROM drive, Bus powered, 0.8 A required N8160-85 8 Support Service 8.1 Software Product Name / Description Part Number PP Support Pack (VMware ESXi 4.1 for 1 processor)(1year) Technical Support Service regarding ESXi (for quick solutions to technical issues) NOTE: It is necessary to purchase a PP support pack for each processor installed in the system. ULH1S-SV40-008F NEC Corporation Revision 9.0, November 8, 2012 19 References Note for Ordering Parts number provided may be needed to modify by country/region when you order the products. For example, the operable parts number for N8100-1743F in EMEA is N8100-1743F -O, adding "-O", the country-specific identifier for EMEA, after the parts number. Please consult our sales representative for your country identifier. Server Management The EXPRESSSCOPE Engine 2, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring Temperature/voltage/power/ fan /degeneration (memory/hard drive) Hardware event log collection With Remote KVM and Media License kit 1 Boot monitoring Booting, BIOS/POST stall, OS stall, shutdown Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote console POST/BIOS setup, DOS utility 2 2 Text-based screen (OS console) 2 GUI-based screen (OS console) - Remote reset/power on-off/ dump (via LAN) Remote control Panic screen, Boot screen 1 1 Remote media (CD/DVD/FD) - Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch 1 1 Scheduling (without UPS) 1 1 Others Set automatic IP address via DNS/DHCP Remote wakeup Wake On LAN, Wake On Ring Centralized management Industry standard 1 2 1 OS shutdown (via LAN) 1 Monitoring and control of multiple servers IPMI 2.0 1 2.0 The feature is not supported on VMware ESXi systems. The standard serial port is not available for the feature. NEC Corporation Revision 9.0, November 8, 2012 20 OS Support Matrix for PCI Cards ESXi 4.1 RHEL 4 x64 RHEL 4 RHEL 5 x64 RHEL 5 RHEL 6 x64 RHEL 6 WS 2003R2 x64 2003R2 WS WS 2008 x64 WS 2008 WS 2008R2 Part number Product Name N8104-126 1000BASE-T Adapter N8104-122 1000BASE-T Adapter (2ch) N8104-125A 1000BASE-T Adapter (4ch) N8104-123A 10GBASE-SR Adapter - N8104-128 10GBASE Adapter (SFP+/2ch) - N8103-128 - - - - - - - - RAID Controller - - N8103-129 RAID Controller N8103-130 RAID Controller N8103-134 RAID Controller - - N8103-135 RAID Controller - - N8103-142 SAS Controller, 6 Gb/s - - - - - N8190-153 Fibre Channel Controller - - - - N8190-154 Fibre Channel Controller (2ch) - - - - N8190-127 Fibre Channel Controller - - N8190-131 Fibre Channel Controller (2ch) - - N8104-131 Dual Port 10Gb Converged Network Adapter - - - - - - - - - - - Tested Operating System List Operating System Remark CentOS 4.8 (x86) CentOS 4.8 (x86_64) CentOS 5.6 (x86) CentOS 5.6 (x86_64) FreeBSD 7.3 (i386) Not support Promise SuperTrak FreeBSD 7.3 (amd64) Not support Promise SuperTrak FreeBSD 8.2 (i386) Not support Promise SuperTrak FreeBSD 8.2 (amd64) Not support Promise SuperTrak Debian GNU/Linux 5.0 (x86) Not support Promise SuperTrak Debian GNU/Linux 5.0 (AMD64) Not support Promise SuperTrak Debian GNU/Linux 6.0 (amd64) Ubuntu 10 LTS (amd64) SUSE Linux Enterprise Server 10 SP3 (x86) Not support Promise SuperTrak SUSE Linux Enterprise Server 10 SP3 (x86_64) Not support Promise SuperTrak SUSE Linux Enterprise Server 11 (x86) Not support Promise SuperTrak SUSE Linux Enterprise Server 11 (x86_64) Not support Promise SuperTrak Fedora 13 (x86) Fedora 13 (x86_64) NEC Corporation Revision 9.0, November 8, 2012 21 Supporting PCI Cards and Installable Slots Part Number Product Name Slots Remarks Slot # : #1 #2 PCI Slot: x8 x8 Card height: LP Slot type: x16 Installable card length (mm) : 200 x8 N8103-142 SAS Controller [PCIe 2.0 x8] N8103-128 RAID Controller (128MB, RAID 0/1) [PCIe 2.0 x8] - N8103-129 RAID Controller (256MB, RAID 0/1) [PCIe 2.0 x8] - N8103-130 RAID Controller (256MB, RAID 0/1/5/6) [PCIe 2.0 x8] - N8103-134 RAID Controller (512MB, RAID 0/1/5/6) [PCIe 2.0 x8] - N8103-135 RAID Controller (512MB, RAID 0/1/5/6) [PCIe 2.0 x8] N8190-127 Fibre Channel Controller [PCIe x4] N8190-153 Fibre Channel Controller [PCIe 2.0 x8] N8190-131 Fibre Channel Controller (2ch) [PCIe x4] N8190-154 Fibre Channel Controller (2ch) [PCIe 2.0 x8] N8104-126 1000BASE-T Adapter [PCIe x1] N8104-122 1000BASE-T Adapter(2ch) [PCIe x4] N8104-125A 1000BASE-T Adapter(4ch) [PCIe x4] N8104-123A 10GBASE-SR adapter [PCIe x8] N8104-128 10GBASE Adapter (SFP+/2ch) [PCIe 2.0 x8] N8104-131 Dual Port 10Gb Converged Network Adapter [PCIe 2.0 x8] N8117-01A Serial Port Adapter NEC Corporation Revision 9.0, November 8, 2012 22 Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 9.0, November 8, 2012 23 Revision History Revision Date Description 9.0 November 8, 2012 Discontinued products removed: SAS Controller / N8103-104A 100GB SATA SSD / N8150-707 8.0 August 3, 2012 New products added: 17-inch LCD Console Drawer (1port) / N8143-84F Keyboard Unit (JP) / N8143-85 Keyboard Unit (UK) / N8143-87 Server Switch Unit (8 server) / N8191-12F Switch Unit Connection Cable 1.8 m / K410-119(1A) Discontinued products removed: Server Switch Unit (8 server) / N8191-10F 7.3 February 13, 2012 Part number changed: 146.5GB 2.5-inch SAS HDD / N8150-374 300GB 2.5-inch SAS HDD / N8150-375 450GB 2.5-inch SAS HDD / N8150-376 600GB 2.5-inch SAS HDD / N8150-377 7.2 January 23, 2012 Part number changed: 73.2GB 2.5-inch SAS HDD / N8150-378 146.5GB 2.5-inch SAS HDD / N8150-379 7.1 January 11, 2012 Discontinued products removed: SCSI Controller / N8103-107 7.0 December 14, 2011 Discontinued products removed: 1GB Memory Kit / N8102-412 6.1 October 18th, 2011 Other: Correct incorrect information in Specification, 3 Memory, 4.2 Internal Drive Configuration, 5.1 LAN Controller, 5.3 Fibre Channel / SAS / SCSI Controller, 7.1 17-inch LCD Console Drawer, 7.2 KVM Switch, and References. 6.0 July 29th, 2011 New products added: 300GB 15K 2.5-inch SAS HDD / N8150-331 900GB 10K 2.5-inch SAS HDD / N8150-332 Discontinued products removed: SCSI Controller / N8103-75 100BASE-TX Adapter / N8104-111 5.0 April 8th, 2011 New products added: 1TB 7.2K 2.5-inch SATA HDD / N8150-334 4.0 February 16th, 2011 New products added: SAS Controller / N8103-142 100GB 2.5-inch SSD / N8150-706 Discontinued products removed: 50GB 2.5-inch SSD / N8150-331 3.0 November 30th, 2010 Discontinued products removed: External FDD / N8160-81 2.0 October 25th, 2010 New products added: 17 inch LCD console unit / N8143-76F 640GB RDX Cartridge / N8152-30 1.0 September 16th, 2010 Initial release NEC Corporation Revision 9.0, November 8, 2012 24