Configuration Guide - Consolidated PSU

NEC Express5800/E120b-1
Configuration Guide
Consolidated Power
Supply model
Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC Express5800 server.
November 8, 2012
Revision 9.0
NEC Corporation
CONFIGURATION GUIDE – NEC EXPRESS5800/E120b-1 / Consolidated Power Supply Model
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 5
Front and Rear Views ........................................................................................................................... 5
Dimensions (mm) .................................................................................................................................. 6
CONFIGURATION DIAGRAM ......................................................................................... 7
SERVER CONFIGURATION ........................................................................................... 8
1
2
3
4
5
6
7
8
Base Models ................................................................................................................................... 8
2nd Processor ................................................................................................................................ 8
Memory ........................................................................................................................................... 8
Internal Hard Disk Drives ............................................................................................................ 10
4.1 RAID Configuration .............................................................................................................. 10
4.2 Internal Drive Configuration ................................................................................................. 11
PCI Card ........................................................................................................................................ 16
5.1 Network Interface Controller ................................................................................................ 16
5.2 External RAID Controller ..................................................................................................... 17
5.3 Fibre Channel / SAS Controller ........................................................................................... 17
5.4 Serial Port Adapter .............................................................................................................. 17
Other Add-in Components .......................................................................................................... 17
6.1 VMware ESXi Pre-install Kit ................................................................................................ 17
Add-on Components ................................................................................................................... 18
7.1 17-inch LCD Console Drawer .............................................................................................. 18
7.2 KVM Switch ......................................................................................................................... 18
7.3 Server Management License............................................................................................... 19
7.4 Flash FDD............................................................................................................................ 19
7.5 Optical Drive ........................................................................................................................ 19
Support Service ........................................................................................................................... 19
8.1 Software............................................................................................................................... 19
REFERENCES............................................................................................................... 20
Note for Ordering ................................................................................................................................ 20
Server Management ............................................................................................................................ 20
OS Support Matrix for PCI Cards ...................................................................................................... 21
Tested Operating System List............................................................................................................ 21
Supporting PCI Cards and Installable Slots ..................................................................................... 22
Copyright Notice and Liability Disclaimer ........................................................................................ 23
REVISION HISTORY ..................................................................................................... 24
NEC Corporation
Revision 9.0, November 8, 2012
2
CONFIGURATION GUIDE – NEC EXPRESS5800/E120b-1 / Consolidated Power Supply Model
Technical Specification
Key Features




High performance with the latest Intel® Xeon® processor 5600 series
Up to 64 GB of high speed DDR3-1333 memory
High energy efficiency with intelligent fan control, power capping feature and 80PLUS® Gold power
supply
Full manageability by integrated EXPRESSSCOPE Engine 2
Specification
Model
E120b-1
Part Number
N8100-1627F
N8100-1689F
Type
Intel® Xeon® Processor L5630
Intel® Xeon® Processor L5640
Clock Speed
2.13 GHz
2.26 GHz
Number of Processor
1 or 2
Cache
12 MB
Cores and Threads
4C-8T
Processor
Chipset
Memory
Internal Storage
6C-12T
Intel® 5500 chipset
Type
DDR3-1333 ECC Unbuffered and Registered Low Power DIMM
Standard Capacity
0 GB
Maximum Capacity
64 GB (8 x 8 GB)
Memory protection
ECC, x4 SDDC
Standard Capacity
0 GB
Maximum Capacity
SAS : 7.2 TB (8 x 900 GB)
SATA : 8 TB (8 x 1 TB)
Disk Controller
SATA : 3 Gb/s (Integrated)
SAS : 6 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard), RAID 5/6/50 (Optional)
SAS : RAID 0/1/5/6/10/50 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional (External drive)
Optical Drive Bays
[free]
Disk Drive Bays [free]
0 [0]
1
2
8 [8]
Expansion Slots [free]
Total: 2 slots available
1 [1] x PCIe 2.0 x8 (x16 connector)
1 [1] x PCIe 2.0 x8 (x8 connector)
Video Controller (VRAM)
Integrated in Server Management Controller (32MB)
Interfaces
2 x VGA (15-pin mini D-sub, 1x front, 1x rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2rear)
8x USB2.0 (2 x front, 4 x rear, 2 x internal)
2x 1000BASE-T LAN connector (1000BASE-T / 100BASE-TX /
10BASE-T, RJ-45, 2 x rear)
1 x Management LAN connector (100BASE-TX / 10BASE-T,
RJ-45, 1 x rear)
Server Management
EXPRESSSCOPE Engine 2
System Fan
Standard
Power Supply
-
NEC Corporation
Revision 9.0, November 8, 2012
3
CONFIGURATION GUIDE – NEC EXPRESS5800/E120b-1 / Consolidated Power Supply Model
Model
Power
Consumption
E120b-1
(Max. Config, Idling)
159 Watt
160 Watt
(Max. Config,
Operating)
Idling
244 Watt
295 Watt
Acoustical Noise
(Sound Pressure
Operating
3
Level)
Dimensions (W x D x H )
51.3 dB
Weight (Minimum / Maximum)
11 kg / 16 kg, 24.25 lbs. / 35.27 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 35° C / 50° to 95° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE
Operating Systems
Microsoft® Windows Server® 2003 R2, Standard Edition
Microsoft® Windows Server® 2003 R2, Enterprise Edition
Microsoft® Windows Server® 2003 R2, Standard x64 Edition
Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition
Microsoft® Windows Server® 2008 Standard
Microsoft® Windows Server® 2008 Standard (x64)
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 Enterprise (x64)
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
4
Red Hat Enterprise Linux 4.8 or later
4
Red Hat Enterprise Linux 4.8 or later (EM64T)
4
Red Hat Enterprise Linux 5.5 or later
4
Red Hat Enterprise Linux 5.5 or later (EM64T)
4
Red Hat Enterprise Linux 6.0 or later (x86)
4
Red Hat Enterprise Linux 6.0 or later (x86_64)
VMware ESXi 4.1
1
2
3
4
54.9 dB
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
x4 SDDC is supported with Registered DIMM only.
On-board SATA RAID controller is supported only on Windows operating systems
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating
environment.
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
NEC Corporation
Revision 9.0, November 8, 2012
4
External Views
Front and Rear Views
Front View
B
A
H
CD E F G
I
J
KLM N
Legend
A.
VGA Connector
H.
Power Button
B.
USB Connectors
I.
Pull-out Tab
C.
Power LED
J.
Drive Bays
D.
Data LAN 1 Activity LED
K.
Hard Drive Activity LED
E.
UID LED
L.
Data LAN 2 Activity LED
F.
BMC Reset Switch
M.
System Status LED
G.
UID LED Button
N.
Dump (NMI) Switch
Rear View
A
B
C
G
D
H
E
I
F
J K
Legend
A.
DC Inlet
G.
VGA Connector
B.
DC Power LED
H.
System Power LED
C.
Serial Port Connector
I.
USB Connectors
Management LAN Connector
UID LED / Button
D.
Data LAN 1 Connector
J.
E.
Data LAN 2 Connector
K.
F.
PCI Slots
NEC Corporation
Revision 9.0, November 8, 2012
5
Dimensions (mm)
44.3
653.0
615.2
444.0
NEC Corporation
Revision 9.0, November 8, 2012
482.0
43.6
6
BBU
slot #1
#1
#2
#3
#4
Processor
#1
BBU
slot #2
Processor
#2
DIMM
DIMM
DIMM
DIMM
#5
#6
#7
#8
PCIe 2.0 x8 (x16 socket)
LP/MD2
PCIe 2.0 x8 (x8 socket)
LP/MD2
Legend:
NEC Corporation
Minimum requirement components
Revision 9.0, November 8, 2012
HDD Bay
HDD Bay
DIMM
DIMM
DIMM
DIMM
HDD Bay
DC-DC Converter
CHASSIS
FRONT
HDD Bay
HDD Bay
2.5-inch
HDD Cage
HDD Bay
CHASSIS
REAR
HDD Bay
HDD Bay
Configuration Diagram
Standard components
7
Server Configuration
1 Base Models
Product Name / Description
Part Number
NEC EXPRESS5800/E120b-1 Server
no RAM, no 2.5-inch HDD
Including:
1 x Intel Xeon L5630, 2.5-inch HDD Cage, EXPRESSBUILDER DVD
NEC EXPRESS5800/E120b-1 Server
no RAM, no 2.5-inch HDD
Including:
1 x Intel Xeon L5640, 2.5-inch HDD Cage, EXPRESSBUILDER DVD
N8100-1627F
N8100-1682F
NOTE:

N8142-36F Consolidated PSU is required for supplying DC powers. Refer to the configuration guide
for Consolidated PSU.
2 2nd Processor
Available sockets: 1
Product Name / Description
Part Number
CPU Kit (4C/L5630)
Intel® Xeon® Processor L5630 (2.13 GHz / 4C-8T / 12 MB)
CPU Kit (4C/L5640)
Intel® Xeon® Processor L5640 (2.26 GHz / 6C-12T / 12 MB)
N8101-477
N8101-478
NOTE:

The 2nd processor must be the same with what is used in the base model
3 Memory
Available slots: 4 per processor
Product Name / Description
Part Number
2GB Memory Kit
2GB (1x 2 GB) DDR3-1333 ECC Unbuffered DIMM
4GB Memory Kit
4GB (1x 4 GB) DDR3-1333 ECC Unbuffered DIMM
8GB Memory Kit
8GB (1x 8 GB) DDR3-1333 ECC Registered DIMM
N8102-413
N8102-414
N8102-411
NOTE:




Minimum one memory kit per processor must be installed.
It is recommended to install two identical memory kits for dual-channel symmetric configuration to
increase memory transfer speed.
Mixing unbuffered and registered DIMM in the same system is not supported.
Actual DIMM speed is set to 1066 MHz when you choose Xeon L5630 Processor.
NEC Corporation
Revision 9.0, November 8, 2012
8
Maximum Memory Speed
See the table below for the actual maximum memory speed on your system.
DDR3 memory speed depends on memory power setting and the native memory bus speed of the memory
controller. All memory buses operate at the clock frequency of the DIMM with the lowest frequency.
Memory Power
Setting
Processor Type
DIMMs per
Channel
DIMM Speed
L5630
-
-
1066 MHz
L5640
Normal (1.5V)
-
1333 MHz
Low (1.35V)
1
1333 MHz
2
1066 MHz
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
The maximum available memory is less than the maximum physical memory supported by your system
because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary
depending on the type and the number of PCI cards you are using.
1
Maximum Memory Size Supported by OS
Maximum Available Memory
4 GB
Microsoft Windows Server 2003 R2, Standard Edition
Microsoft Windows Server 2008 Standard
4 GB (HW-DEP enabled)
App. 3.3 GB (HW-DEP disabled)
32 GB
Microsoft Windows Server 2003 R2, Standard x64 Edition
Microsoft Windows Server 2008 Standard (x64)
Microsoft Windows Server 2008 R2 Standard (x64)
32 GB
64 GB
Microsoft Windows Server 2003 R2, Enterprise Edition
Microsoft Windows Server 2008 Enterprise
64 GB
1 TB
Microsoft Windows Server 2003 R2, Enterprise x64 Edition
64 GB
2 TB
Microsoft Windows Server 2008 Enterprise (x64)
Microsoft Windows Server 2008 R2 Enterprise (x64)
64 GB
16 GB
Red Hat Enterprise Linux ES4
Red Hat Enterprise Linux ES4 (EM64T)
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 5 Advanced Platform
Red Hat Enterprise Linux 6
16 GB
64 GB
Red Hat Enterprise Linux AS4
64 GB
256 GB
Red Hat Enterprise Linux AS4 (EM64T)
Red Hat Enterprise Linux 5 (EM64T)
Red Hat Enterprise Linux 5 Advanced Platform (EM64T)
64 GB
256 GB
1
or 1TB
VMware ESXi 4.1
64 GB
Up to 255 GB of main memory is available to each virtual machine.
NEC Corporation
Revision 9.0, November 8, 2012
9
4 Internal Hard Disk Drives
4.1
RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration.
Available Disk
Non-RAID
Refer to 4.2.1
SATA
128MB Cache
Refer to 4.2.2
SAS, SATA
256MB Cache
Refer to 4.2.3
SAS, SATA
256MB Cache
Refer to 4.2.4
SAS, SATA
512MB Cache
Refer to 4.2.5
SAS, SATA
On-board SATA
RAID
RAID 0/1
Optional RAID
Controller
RAID 5/6
NOTE:




On-board SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
Hot plug insertion/removal is not supported with the on-board SATA non-RAID controller..
All hard drives within a RAID array should be of the same capacity and rotation speed.
SAS and SATA hard drives must be installed in separate group of HDD Cages.
Group #1

Group #2
Group #3
Group #4
An optional RAID controller occupies one PCI slot.
NEC Corporation
Revision 9.0, November 8, 2012
10
4.2
Internal Drive Configuration
4.2.1
On-board SATA Controller
Category
Product Name / Description
Part Number
Storage Controller
On-board SATA Controller
6 x SATA ports, RAID 0/1/10 capable
Internal SAS/SATA Cable
1x mini-SAS to 4x single SATA, 2set
2.5-inch HDD Cage
8 x 2.5-inch hot plug hard drive bays
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
(Standard)
Cable
HDD Cage
HDD
6 slots
available
SATA
(Standard)
(Standard)
N8150-276
N8150-277
N8150-334
NOTE

On-board SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.

Hot plug insertion/removal is not supported with the on-board SATA non-RAID controller..

All hard drives within a RAID array should be of the same capacity and rotation speed.
NEC Corporation
Revision 9.0, November 8, 2012
11
4.2.2
RAID 0/1 Controller with 128 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (128MB, RAID 0/1)
Promise SuperTrak TX8760T-128
RAID 0/1, 128MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s,
LP / FH
RAID Battery Backup Unit
for Promise SuperTrak EX8760T
Internal SAS/SATA Cable
1x mini-SAS to 4x single SATA, 2set
2.5-inch HDD Cage
8 x 2.5-inch hot plug hard drive bays
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
450GB HDD
1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
600GB HDD
1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
900GB HDD
1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
73.2GB HDD
1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8103-128
RAID BBU
Recommended
Cable
HDD Cage
HDD
8 slots
available
SAS
SATA
N8103-140
(Standard)
(Standard)
N8150-374
N8150-375
N8150-376
N8150-377
N8150-332
N8150-378
N8150-379
N8150-331
N8150-276
N8150-277
N8150-334
NOTE:

All hard drives within a RAID array should be of the same capacity and rotation speed.

SAS and SATA hard drives must be installed in separate group of HDD Cages.
NEC Corporation
Revision 9.0, November 8, 2012
12
4.2.3
RAID 0/1 Controller with 256 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (256MB, RAID 0/1)
LSI MegaRAID SAS 9264-8i
RAID 0/1, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s,
LP / FH
RAID Battery Backup Unit
for LSI MegaRAID SAS 9264
Internal SAS/SATA Cable
1x mini-SAS to 4x single SATA, 2set
2.5-inch HDD Cage
8 x 2.5-inch hot plug hard drive bays
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
450GB HDD
1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
600GB HDD
1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
900GB HDD
1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
73.2GB HDD
1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8103-129
RAID BBU
Recommended
Cable
HDD Cage
HDD
8 slots
available
SAS
SATA
N8103-123
(Standard)
(Standard)
N8150-374
N8150-375
N8150-376
N8150-377
N8150-332
N8150-378
N8150-379
N8150-331
N8150-276
N8150-277
N8150-334
NOTE:

All hard drives within a RAID array should be of the same capacity and rotation speed.

SAS and SATA hard drives must be installed in separate group of HDD Cages.
NEC Corporation
Revision 9.0, November 8, 2012
13
4.2.4
RAID 5/6 Controller with 256 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (256MB, RAID 0/1/5/6)
LSI MegaRAID SAS 9264-8i
RAID 0/1/5/6, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA
3Gb/s, LP / FH
RAID Battery Backup Unit
for LSI MegaRAID SAS 9264
Internal SAS/SATA Cable
1x mini-SAS to 4x single SATA, 2set
2.5-inch HDD Cage
8 x 2.5-inch hot plug hard drive bays
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
450GB HDD
1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
600GB HDD
1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
900GB HDD
1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
73.2GB HDD
1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8103-130
RAID BBU
Recommended
Cable
HDD Cage
HDD
8 slots
available
SAS
SATA
N8103-123
(Standard)
(Standard)
N8150-374
N8150-375
N8150-376
N8150-377
N8150-332
N8150-378
N8150-379
N8150-331
N8150-276
N8150-277
N8150-334
NOTE:

All hard drives within a RAID array should be of the same capacity and rotation speed.

SAS and SATA hard drives must be installed in separate group of HDD Cages.
NEC Corporation
Revision 9.0, November 8, 2012
14
4.2.5
RAID 5/6 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller(512MB, RAID0/1/5/6)
Promise SuperTrak EX8760T-512
RAID 0/1/5/6, 512MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA
3Gb/s, LP / FH
RAID Battery Backup Unit
for Promise SuperTrak EX8760T
Internal SAS/SATA Cable
1x mini-SAS to 4x single SATA, 2set
2.5-inch HDD Cage
8 x 2.5-inch hot plug hard drive bays
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
450GB HDD
1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
600GB HDD
1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
900GB HDD
1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
73.2GB HDD
1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8103-134
RAID BBU
Recommended
Cable
HDD Cage
HDD
8 slots
available
SAS
SATA
N8103-140
(Standard)
(Standard)
N8150-374
N8150-375
N8150-376
N8150-377
N8150-332
N8150-378
N8150-379
N8150-331
N8150-276
N8150-277
N8150-334
NOTE:

All hard drives within a RAID array should be of the same capacity and rotation speed.

SAS and SATA hard drives must be installed in separate group of HDD Cages.
NEC Corporation
Revision 9.0, November 8, 2012
15
5
PCI Card
5.1
Network Interface Controller
Category
Product Name / Description
Part Number
1GbE
1000BASE-T Adapter
Intel® PRO/1000 PT Server Adapter
PCIe x1, LP / FH
1000BASE-T Adapter (2ch)
Intel® PRO/1000 PT Dual Port Server Adapter
PCIe x4, LP
1000BASE-T Adapter (4ch)
Intel® PRO/1000 PT Quad Port Server Adapter
PCIe x4, LP / FH
NOTE:
Network cables with RJ-45 plug covers cannot be used.
N8104-126
10GBASE-SR Adapter
Chelsio S310E-SR 10GbE Storage Accelerator
PCIe x8, LP / FH
10GBASE Adapter (SFP+/2ch)
Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port
Network Interface Card
PCIe 2.0 x8, LP / FH
NOTE:
- N8104-129 SFP+ Module is required to connect with an
optical cable.
- Up to 2 SFP+ Modules can be installed.
- On Windows Server 2003R2 /2008 / 2008R2 and Red Hat
Linux 5.x(EM64T) and 6.x(x86_64) operating systems,
teaming and bonding features across one or two identical
adapters are supported. A team can include up to two ports
and up to two teams per system are allowed.
- On Red Hat Linux 5.x(x86) and 6.x(x86) operating systems,
bonding features within one adapter with up to two ports are
supported. One team per system is allowed.
N8104-123A
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-128
Dual Port 10Gb Converged Network Adapter
BROCADE 1020 Dual Port 10Gbps Converged Network Adapter
PCIe 2.0 x8, LP / FH, 2 x SFP module
N8104-129
10GbE
Ctrlr
Module
Converged Network
N8104-122
N8104-125A
N8104-128
N8104-131
NOTE:

Teaming and bonding features across the standard LAN and optional PCIe based GbE LAN controller
(excluding N8104-126) are supported on Windows Server 2003R2 /2008 / 2008R2 and Red Hat Linux
5.x and 6.x operating systems.

When installing a 10GBASE-SR Adapter, no other additional 10GbE LAN controllers are allowed.

Teaming feature is not supported on iSCSI interfaces.
NEC Corporation
Revision 9.0, November 8, 2012
16
5.2
External RAID Controller
Category
Product Name / Description
Part Number
Controller
RAID Controller (512MB, RAID0/1/5/6)
Promise SuperTrak EX8768
RAID 0/1/5/6, 512MB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s,
SATA3Gb/s, LP / FH
RAID Battery Backup Unit
for Promise SuperTrak EX8760T and EX8768
N8103-135
RAID BBU
5.3
N8103-140
Fibre Channel / SAS Controller
Category
Product Name / Description
Part Number
Fibre Channel
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1250-F8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8, LP / FH
Fibre Channel Controller (2ch)
Emulex LightPulse LPe12002-M8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8, LP / FH
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1150-F4 Host Bus Adapter
4Gb/s, Optical, PCIe x4, LP / FH
Fibre Channel Controller (2ch)
Emulex LightPulse LPe11002-M4 Host Bus Adapter
4Gb/s, Optical, PCIe 2.0 x4, LP / FH
SAS Controller
LSI ISAS9212-4i4 Host Bus Adapter
6Gbps SAS, Int. 4, Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8,
LP/FH
N8190-153
SAS
5.4
N8190-154
N8190-127
N8190-131
N8103-142
Serial Port Adapter
Product Name / Description
Part Number
Serial Port Adapter
Serial port fixed to PCI bracket
NOTE:
Supports up to one adapter
N8117-01A
6 Other Add-in Components
6.1
VMware ESXi Pre-install Kit
Product Name / Description
Part Number
VMware ESXi 4.1 Base Kit
Including USB flash memory, VMware ESXi 4.1 Recovery CD
NOTE:
The Base Kit may not be available in some regions. Please contact our sales
representative to confirm if it is available in your country.
The Base Kit must be ordered with the base model.
Installation of VMware ESXi onto hard drives is not supported.
N8106-004F
NEC Corporation
Revision 9.0, November 8, 2012
17
7 Add-on Components
7.1
17-inch LCD Console Drawer
Category
Drawer
Drawer
w/ KVM
Cable
Drawer
Drawer
w/o KVM
Keypad
7.2
Product Name / Description
Part Number
17-inch LCD Console Drawer (8port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port
KVM switch, 1U height
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m,
15-pin mini D-sub VGA cable 2 m
17inch LCD Console Drawer (1port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad
with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8
m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD
Console Drawer (1port)
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD
Console Drawer (1port)
N8143-77F
K410-118(1A)
K410-118(03)
K410-118(05)
N8143-76F
N8143-84F
N8143-85
N8143-87
KVM Switch
Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server)
1U USB 8 port KVM switch
N8191-12F
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-118(1A)
Cable
KVM
Cascading
NEC Corporation
Revision 9.0, November 8, 2012
K410-118(03)
K410-118(05)
K410-119(1A)
18
7.3
Server Management License
The server integrates the EXPRESSSCOPE Engine 2 as standard. Refer to Server Management
(References) for the standard management features. For more extensive remote KVM and remote media
features, choose the following kit.
Product Name / Description
Part Number
Remote KVM and Media License Kit
N8115-03
License for one server.
Remote KVM and remote media are enabled regardless of OS status.
Remote KVM:
Displays a graphics console on the web browser of the remote terminal
(PC/server).
Controls keyboard and mouse via the remote terminals' web browser
Remote media:
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals
(PC/server) as if accessing the local drives.
NOTE: Remote KVM and remote media features are not available for virtual
machines.
7.4
Flash FDD
Choose the Flash FDD if you need to prepare the alternative device for floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-86
NOTE:

Up to one drive can be connected.
7.5
Optical Drive
Product Name / Description
Part Number
External DVD-ROM drive
Slim DVD-ROM drive, Bus powered, 0.8 A required
N8160-85
8 Support Service
8.1
Software
Product Name / Description
Part Number
PP Support Pack (VMware ESXi 4.1 for 1 processor)(1year)
Technical Support Service regarding ESXi (for quick solutions to technical issues)
NOTE: It is necessary to purchase a PP support pack for each processor installed in
the system.
ULH1S-SV40-008F
NEC Corporation
Revision 9.0, November 8, 2012
19
References
Note for Ordering
Parts number provided may be needed to modify by country/region when you order the products.
For example, the operable parts number for N8100-1743F in EMEA is N8100-1743F -O, adding "-O", the
country-specific identifier for EMEA, after the parts number.
Please consult our sales representative for your country identifier.
Server Management
The EXPRESSSCOPE Engine 2, integrated into the server, provides superior remote control and system
management features listed in the table below.
Standard
Hardware
monitoring
Temperature/voltage/power/
fan /degeneration (memory/hard drive)

Hardware event log collection

With Remote KVM
and Media License
kit


1
Boot monitoring
Booting, BIOS/POST stall, OS stall,
shutdown

Alerting
HW error, Boot error and OS panic
(by SNMP, E-Mail)

Remote console
POST/BIOS setup, DOS utility

2


2

Text-based screen (OS console)

2

GUI-based screen (OS console)
-
Remote reset/power on-off/ dump

(via LAN)
Remote control
Panic screen, Boot screen

1



1

Remote media (CD/DVD/FD)
-

Server Management Command Line
Protocol (DMTF compliant)


Remote control via Web browser
(without dedicated app)


Remote batch

1

1
Scheduling (without UPS)

1

1
Others
Set automatic IP address via DNS/DHCP

Remote wakeup
Wake On LAN, Wake On Ring

Centralized
management
Industry standard
1
2

1
OS shutdown
(via LAN)


1
Monitoring and control of multiple servers

IPMI
2.0

1
2.0
The feature is not supported on VMware ESXi systems.
The standard serial port is not available for the feature.
NEC Corporation
Revision 9.0, November 8, 2012
20
OS Support Matrix for PCI Cards
ESXi 4.1
RHEL 4 x64
RHEL 4
RHEL 5 x64
RHEL 5
RHEL 6 x64
RHEL 6
WS 2003R2
x64 2003R2
WS
WS 2008 x64
WS 2008
WS 2008R2
Part number
Product Name
N8104-126
1000BASE-T Adapter

N8104-122
1000BASE-T Adapter (2ch)

N8104-125A
1000BASE-T Adapter (4ch)

N8104-123A
10GBASE-SR Adapter
-
N8104-128
10GBASE Adapter (SFP+/2ch)
-
N8103-128
-
-
-
-
-
-
-
-

RAID Controller
-
-

N8103-129
RAID Controller

N8103-130
RAID Controller

N8103-134
RAID Controller
-
-

N8103-135
RAID Controller
-
-

N8103-142
SAS Controller, 6 Gb/s
-
-
-
-
-
N8190-153
Fibre Channel Controller
-
-
-
-

N8190-154
Fibre Channel Controller (2ch)
-
-
-
-

N8190-127
Fibre Channel Controller
-
-

N8190-131
Fibre Channel Controller (2ch)
-
-

N8104-131
Dual Port 10Gb Converged Network Adapter
-
-
-
-
-
-
-
-
-
-
-
Tested Operating System List
Operating System
Remark
CentOS 4.8 (x86)
CentOS 4.8 (x86_64)
CentOS 5.6 (x86)
CentOS 5.6 (x86_64)
FreeBSD 7.3 (i386)
Not support Promise SuperTrak
FreeBSD 7.3 (amd64)
Not support Promise SuperTrak
FreeBSD 8.2 (i386)
Not support Promise SuperTrak
FreeBSD 8.2 (amd64)
Not support Promise SuperTrak
Debian GNU/Linux 5.0 (x86)
Not support Promise SuperTrak
Debian GNU/Linux 5.0 (AMD64)
Not support Promise SuperTrak
Debian GNU/Linux 6.0 (amd64)
Ubuntu 10 LTS (amd64)
SUSE Linux Enterprise Server 10 SP3 (x86)
Not support Promise SuperTrak
SUSE Linux Enterprise Server 10 SP3 (x86_64)
Not support Promise SuperTrak
SUSE Linux Enterprise Server 11 (x86)
Not support Promise SuperTrak
SUSE Linux Enterprise Server 11 (x86_64)
Not support Promise SuperTrak
Fedora 13 (x86)
Fedora 13 (x86_64)
NEC Corporation
Revision 9.0, November 8, 2012
21
Supporting PCI Cards and Installable Slots
Part Number
Product Name
Slots
Remarks
Slot # :
#1
#2
PCI Slot:
x8
x8
Card height:
LP
Slot type:
x16
Installable card length (mm) :
200
x8
N8103-142
SAS Controller
[PCIe 2.0 x8]


N8103-128
RAID Controller (128MB, RAID 0/1)
[PCIe 2.0 x8]
-

N8103-129
RAID Controller (256MB, RAID 0/1)
[PCIe 2.0 x8]
-

N8103-130
RAID Controller (256MB, RAID 0/1/5/6)
[PCIe 2.0 x8]
-

N8103-134
RAID Controller (512MB, RAID 0/1/5/6)
[PCIe 2.0 x8]
-

N8103-135
RAID Controller (512MB, RAID 0/1/5/6)
[PCIe 2.0 x8]


N8190-127
Fibre Channel Controller
[PCIe x4]


N8190-153
Fibre Channel Controller
[PCIe 2.0 x8]


N8190-131
Fibre Channel Controller (2ch)
[PCIe x4]


N8190-154
Fibre Channel Controller (2ch)
[PCIe 2.0 x8]


N8104-126
1000BASE-T Adapter
[PCIe x1]


N8104-122
1000BASE-T Adapter(2ch)
[PCIe x4]


N8104-125A
1000BASE-T Adapter(4ch)
[PCIe x4]


N8104-123A
10GBASE-SR adapter
[PCIe x8]


N8104-128
10GBASE Adapter (SFP+/2ch)
[PCIe 2.0 x8]


N8104-131
Dual Port 10Gb Converged Network
Adapter [PCIe 2.0 x8]


N8117-01A
Serial Port Adapter


NEC Corporation
Revision 9.0, November 8, 2012
22
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation
Revision 9.0, November 8, 2012
23
Revision History
Revision
Date
Description
9.0
November 8, 2012
Discontinued products removed:
SAS Controller / N8103-104A
100GB SATA SSD / N8150-707
8.0
August 3, 2012
New products added:
17-inch LCD Console Drawer (1port) / N8143-84F
Keyboard Unit (JP) / N8143-85
Keyboard Unit (UK) / N8143-87
Server Switch Unit (8 server) / N8191-12F
Switch Unit Connection Cable 1.8 m / K410-119(1A)
Discontinued products removed:
Server Switch Unit (8 server) / N8191-10F
7.3
February 13, 2012
Part number changed:
146.5GB 2.5-inch SAS HDD / N8150-374
300GB 2.5-inch SAS HDD / N8150-375
450GB 2.5-inch SAS HDD / N8150-376
600GB 2.5-inch SAS HDD / N8150-377
7.2
January 23, 2012
Part number changed:
73.2GB 2.5-inch SAS HDD / N8150-378
146.5GB 2.5-inch SAS HDD / N8150-379
7.1
January 11, 2012
Discontinued products removed:
SCSI Controller / N8103-107
7.0
December 14, 2011
Discontinued products removed:
1GB Memory Kit / N8102-412
6.1
October 18th, 2011
Other:
Correct incorrect information in Specification, 3 Memory, 4.2 Internal Drive
Configuration, 5.1 LAN Controller, 5.3 Fibre Channel / SAS / SCSI
Controller, 7.1 17-inch LCD Console Drawer, 7.2 KVM Switch, and
References.
6.0
July 29th, 2011
New products added:
300GB 15K 2.5-inch SAS HDD / N8150-331
900GB 10K 2.5-inch SAS HDD / N8150-332
Discontinued products removed:
SCSI Controller / N8103-75
100BASE-TX Adapter / N8104-111
5.0
April 8th, 2011
New products added:
1TB 7.2K 2.5-inch SATA HDD / N8150-334
4.0
February 16th, 2011
New products added:
SAS Controller / N8103-142
100GB 2.5-inch SSD / N8150-706
Discontinued products removed:
50GB 2.5-inch SSD / N8150-331
3.0
November 30th, 2010
Discontinued products removed:
External FDD / N8160-81
2.0
October 25th, 2010
New products added:
17 inch LCD console unit / N8143-76F