data sheet - family

Baumer electric
Actuator-Sensor-Interface
AS-Interface module
ASIA 56A2220
Art.-Code: 156038
82
• Specification 2.11
41
44,5
• Standard addressing mode as
S-slave; up to 31 modules
mounting module base
ø 4,4 (2x)
13,3
• Fault diagnosis LED‘s
ø 2,8 to 6,0
BUS
EXT
38
ø 16
20
• Output diagnosis feedback
35 (DIN rail)
56
44
• External power supply with flat
cables for two actuators
bus data
voltage supply range
supply current
reverse polarity protection
E/A configuration
ID-code / ID-2 code
AS-i voltage indicator / error indicator
inputs
potential free inputs
cage clamps
isolation voltage AS-i <> isolated inputs
input current high / low
input voltage high / low
input indicator
outputs
switching element / polarity
galvanic separation AS-i <> load circuit
switching current per output Imax
total current for outputs
short-circuit protection / with feedback
watchdog for bus monitoring
output indicator
external power supply for outputs
voltage range external feed
max. load inductivity (mH) @ 3,3 A
general
protection class
temperature range / storage temperature
housing material
specification power supply unit for external feed
mounting
EMC
certificate no.
bus cable
energy cable
6
• Two potential free inputs 24 VDC
add. cable nut
max. 75
• Address programming via jack
EXT
• Profile S - 3.F.F
20
25,5
20
connection diagram
26,5 - 33,1 VDC
≤ 25 mA
yes
3 HEX
F HEX / F HEX
green LED / red LED
yes, 24 VDC
-; IN1...IN2
2000 VDC
≥ 1,5 mA / ≤ 0,5 mA
> 10 VDC / < 5 VDC
yellow LED
FET / plus switching (PNP)
2000 VDC
3,3 A
4A
yes / peripheral error diagnosis LED
yes
yellow LED
via separate AS-i flat cable, black
12 - 30 VDC
≤ 25 mH
IP 65 (with EPDM cable)
-25...+70 °C / -25...+85 °C
PBT / PC (UL 94 V-0)
according to PELV
DIN rail / screws
refer to the AS-i brochure
60307
AS-i
+
AS-i
AS-i
-
D0
.
.
.
D3
+
IN
1
+
IN
2
0+
0EX+
0+
0EX+
EXT+
EXT -
3
4
general
port assignment:
D0, D1
input
D2, D3
output
possible conductor cross-sections:
sensor terminals:
0,08...2,5 mm2,
actuator terminals:
0,08...2,5 mm2
max. outer cable diameter: ø 2,8...6 mm
diagnosis
ASI
Error
(green) (red)
Status
Description
POWER OFF
Address = 0
no data exchange
no AS-i power
Address = 0
Watchdog activated,
Address = 0
ok
outputs:
- overload / shorted
ok
peripheral error
LED dark
LED light
LED flashing
- A periperal error at the outputs does not
activate a master config. error
- Break of output cables not monitored
Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld
Drawn: 02.05.05/meo
Checked: 04.05.05/phw
Technical specifications subject to change
Tel. +41 52 728 11 22 Fax +41 52 728 11 44
Released: 04.05.05/phw
Last change: 23.12.05/phw
Baumer electric
Actuator-Sensor-Interface
AS-Interface module
ASIA 56A2223
Art.-Code: 147629
82
• Specification 2.11
41
44,5
• Extended addressing mode as
A/B-slave; up to 62 modules
mounting module base
ø 4,4 (2x)
13,3
• Fault diagnosis LED‘s
ø 2,8 to 6,0
BUS
EXT
ø 16
20
• Output diagnosis feedback
35 (DIN rail)
38
56
44
• External power supply with flat
cables for two actuators
bus data
voltage supply range
supply current
reverse polarity protection
E/A configuration
ID-code / ID-2 code
AS-i voltage indicator / error indicator
inputs
potential free inputs
cage clamps
isolation voltage AS-i <> isolated inputs
input current high / low
input voltage high / low
input indicator
outputs
switching element / polarity
galvanic separation AS-i <> load circuit
switching current per output Imax
total current for outputs
short-circuit protection / with feedback
watchdog for bus monitoring
output indicator
external power supply for outputs
voltage range external feed
max. load inductivity (mH) @ 3,3 A
general
protection class
temperature range / storage temperature
housing material
specification power supply unit for external feed
mounting
EMC
certificate no.
bus cable
energy cable
6
• Two potential free inputs 24 VDC
add. cable nut
max. 75
• Address programming via jack
EXT
• Profile S - B.A.E
20
25,5
20
connection diagram
26,5 - 33,1 VDC
≤ 25 mA
yes
B HEX
A HEX / E HEX
green LED / red LED
yes, 24 VDC
-; IN1...IN2
2000 VDC
≥ 1,5 mA / ≤ 0,5 mA
> 10 VDC / < 5 VDC
yellow LED
FET / plus switching (PNP)
2000 VDC
3,3 A
4A
yes / peripheral error LPF
yes
yellow LED
via separate AS-i flat cable, black
12 - 30 VDC
≤ 25 mH
IP 65 (with EPDM cable)
-25...+70 °C / -25...+85 °C
PBT / PC (UL 94 V-0)
according to PELV
DIN rail / screws
refer to the AS-i brochure
60303
AS-i
+
AS-i
AS-i
-
D0
.
.
.
D3
+
IN
1
+
IN
2
0+
0EX+
0+
0EX+
EXT+
EXT -
3
4
general
port assignment:
D0, D1
output
D2, D3
input
possible conductor cross-sections:
sensor terminals:
0,08...2,5 mm2,
actuator terminals:
0,08...2,5 mm2
max. outer cable diameter: ø 2,8...6 mm
diagnosis
ASI
Error
(green) (red)
Status
Description
POWER OFF
Address = 0
no data exchange
no AS-i power
Address = 0
Watchdog activated,
Address = 0
ok
outputs:
- overload / shorted
ok
peripheral error
LED dark
LED light
LED flashing
- A periperal error at the outputs does not
activate a master config. error
- Break of output cables not monitored
Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld
Drawn: 03.12.03/rue
Checked: 12.03.04/phw
Technical specifications subject to change
Tel. +41 52 728 11 22 Fax +41 52 728 11 44
Released: 20.04.04/phw
Last change: 06.06.05/phw