Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 56A2220 Art.-Code: 156038 82 • Specification 2.11 41 44,5 • Standard addressing mode as S-slave; up to 31 modules mounting module base ø 4,4 (2x) 13,3 • Fault diagnosis LED‘s ø 2,8 to 6,0 BUS EXT 38 ø 16 20 • Output diagnosis feedback 35 (DIN rail) 56 44 • External power supply with flat cables for two actuators bus data voltage supply range supply current reverse polarity protection E/A configuration ID-code / ID-2 code AS-i voltage indicator / error indicator inputs potential free inputs cage clamps isolation voltage AS-i <> isolated inputs input current high / low input voltage high / low input indicator outputs switching element / polarity galvanic separation AS-i <> load circuit switching current per output Imax total current for outputs short-circuit protection / with feedback watchdog for bus monitoring output indicator external power supply for outputs voltage range external feed max. load inductivity (mH) @ 3,3 A general protection class temperature range / storage temperature housing material specification power supply unit for external feed mounting EMC certificate no. bus cable energy cable 6 • Two potential free inputs 24 VDC add. cable nut max. 75 • Address programming via jack EXT • Profile S - 3.F.F 20 25,5 20 connection diagram 26,5 - 33,1 VDC ≤ 25 mA yes 3 HEX F HEX / F HEX green LED / red LED yes, 24 VDC -; IN1...IN2 2000 VDC ≥ 1,5 mA / ≤ 0,5 mA > 10 VDC / < 5 VDC yellow LED FET / plus switching (PNP) 2000 VDC 3,3 A 4A yes / peripheral error diagnosis LED yes yellow LED via separate AS-i flat cable, black 12 - 30 VDC ≤ 25 mH IP 65 (with EPDM cable) -25...+70 °C / -25...+85 °C PBT / PC (UL 94 V-0) according to PELV DIN rail / screws refer to the AS-i brochure 60307 AS-i + AS-i AS-i - D0 . . . D3 + IN 1 + IN 2 0+ 0EX+ 0+ 0EX+ EXT+ EXT - 3 4 general port assignment: D0, D1 input D2, D3 output possible conductor cross-sections: sensor terminals: 0,08...2,5 mm2, actuator terminals: 0,08...2,5 mm2 max. outer cable diameter: ø 2,8...6 mm diagnosis ASI Error (green) (red) Status Description POWER OFF Address = 0 no data exchange no AS-i power Address = 0 Watchdog activated, Address = 0 ok outputs: - overload / shorted ok peripheral error LED dark LED light LED flashing - A periperal error at the outputs does not activate a master config. error - Break of output cables not monitored Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 02.05.05/meo Checked: 04.05.05/phw Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: 04.05.05/phw Last change: 23.12.05/phw Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 56A2223 Art.-Code: 147629 82 • Specification 2.11 41 44,5 • Extended addressing mode as A/B-slave; up to 62 modules mounting module base ø 4,4 (2x) 13,3 • Fault diagnosis LED‘s ø 2,8 to 6,0 BUS EXT ø 16 20 • Output diagnosis feedback 35 (DIN rail) 38 56 44 • External power supply with flat cables for two actuators bus data voltage supply range supply current reverse polarity protection E/A configuration ID-code / ID-2 code AS-i voltage indicator / error indicator inputs potential free inputs cage clamps isolation voltage AS-i <> isolated inputs input current high / low input voltage high / low input indicator outputs switching element / polarity galvanic separation AS-i <> load circuit switching current per output Imax total current for outputs short-circuit protection / with feedback watchdog for bus monitoring output indicator external power supply for outputs voltage range external feed max. load inductivity (mH) @ 3,3 A general protection class temperature range / storage temperature housing material specification power supply unit for external feed mounting EMC certificate no. bus cable energy cable 6 • Two potential free inputs 24 VDC add. cable nut max. 75 • Address programming via jack EXT • Profile S - B.A.E 20 25,5 20 connection diagram 26,5 - 33,1 VDC ≤ 25 mA yes B HEX A HEX / E HEX green LED / red LED yes, 24 VDC -; IN1...IN2 2000 VDC ≥ 1,5 mA / ≤ 0,5 mA > 10 VDC / < 5 VDC yellow LED FET / plus switching (PNP) 2000 VDC 3,3 A 4A yes / peripheral error LPF yes yellow LED via separate AS-i flat cable, black 12 - 30 VDC ≤ 25 mH IP 65 (with EPDM cable) -25...+70 °C / -25...+85 °C PBT / PC (UL 94 V-0) according to PELV DIN rail / screws refer to the AS-i brochure 60303 AS-i + AS-i AS-i - D0 . . . D3 + IN 1 + IN 2 0+ 0EX+ 0+ 0EX+ EXT+ EXT - 3 4 general port assignment: D0, D1 output D2, D3 input possible conductor cross-sections: sensor terminals: 0,08...2,5 mm2, actuator terminals: 0,08...2,5 mm2 max. outer cable diameter: ø 2,8...6 mm diagnosis ASI Error (green) (red) Status Description POWER OFF Address = 0 no data exchange no AS-i power Address = 0 Watchdog activated, Address = 0 ok outputs: - overload / shorted ok peripheral error LED dark LED light LED flashing - A periperal error at the outputs does not activate a master config. error - Break of output cables not monitored Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 03.12.03/rue Checked: 12.03.04/phw Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: 20.04.04/phw Last change: 06.06.05/phw