Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 36A4011 Art.-Code: 127453 59,6 • Specification 2.11 / Mini-Module 52 • Standard addressing mode as S-slave; up to 31 modules 27,2 14 LED's 18 36 3 4 • Spring loaded terminals (cage clamp) • Fault diagnosis LED‘s bus data voltage supply range supply current reverse polarity protection E/A configuration ID-Code / ID-2 AS-i voltage indicator / error indicator inputs supply voltage for sensor short-circuit protection with feedback total current for sensors -25...+40 °C total current for sensors +40...+70 °C polarity of the inputs input current high / low input voltage high / low input indicator general protection class temperature range / storage temperature housing material mounting EMC certificate nr. ø 5,2 2 4,4 1 7,6 • Power supply for sensors via bus max. 50 • Connection for four 3-wire sensors - + • Profile S - 0.F.F 2,2 ø 2,8 to 5,0 13,6 ø 13 20,5 connection diagram 26,5 - 33,1 VDC ≤ 190 mA yes 0 HEX F HEX / F HEX green LED / red LED AS-i + 18 - 30 VDC yes ≤ 170 mA ≤ 130 mA PNP ≥ 1,5 mA / ≤ 0,5 mA > 10 VDC / < 5 VDC yellow LED IP 65 (with EPDM cable) -25...+70 °C / -25...+85 °C PBT / PC (UL 94 V-0) screws (2 x M4) refer to the AS-i brochure 59903 AS-i - D0 . . . AS-i D3 + IN 1 + IN 2 + IN 3 + IN 4 general port assignment: D0, D1, D2, D3 input possible conductor cross-sections: sensor terminals: 0,08...0,5 mm2 max. outer cable diameter: ø 2,8...5 mm diagnosis ASI Error (green) (red) Status Description POWER OFF Address = 0 No data exchange No ASi power Address = 0 Watchdog activated, Address = 0 ok -Sensor supply overload -Sensor supply shorted ok External RESET, overload LED dark Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 03.12.03/rue Checked: LED light LED flashing Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: Last change: 29.11.04/phw Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 36A4021 Art.-Code: 148115 59,6 • Specification 2.11 / Mini-Module 52 • Extended addressing mode as A/B-slave; up to 62 modules 27,2 14 LED's 18 36 3 4 • Spring loaded terminals (cage clamp) • Fault diagnosis LED‘s bus data voltage supply range supply current reverse polarity protection E/A configuration ID-Code / ID-2 code AS-i voltage indicator / error indicator inputs supply voltage for sensors short-circuit protection with feedback total current for sensors -25...+70 °C polarity of the inputs input current high / low input voltage high / low input indicator general protection class temperature range / storage temperature housing material mounting EMC certificate no. ø 5,2 2 4,4 1 7,6 • Power supply for sensors via bus max. 50 • Connection for four 3-wire sensors - + • Profile S - 0.A.E 2,2 ø 2,8 to 5,0 13,6 ø 13 20,5 connection diagram 26,5 - 33,1 VDC ≤ 170 mA yes 0 HEX A HEX / E HEX green LED / red LED AS-i + 18 - 30 VDC yes ≤ 125 mA PNP ≥ 1,5 mA / ≤ 0,5 mA > 10 VDC / < 5 VDC yellow LED IP 65 (with EPDM cable) -25...+70 °C / -25...+85 °C PBT / PC (UL 94 V-0) screws (2 x M4) refer to the AS-i brochure 59901 AS-i 1 + IN 2 + IN 3 D0 D3 + IN 4 . . . AS-i - + IN general port assignment: D0, D1, D2, D3 input possible conductor cross-sections: sensor terminals: 0,08...0,5 mm2 max. outer cable diameter: ø 2,8...5 mm diagnosis ASI Error (green) (red) Status Description POWER OFF Address = 0 No data exchange No ASi power Address = 0 Watchdog activated, Address = 0 ok -Sensor supply overload -Sensor supply shorted ok External RESET, overload LED dark Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 03.12.03/rue Checked: 12.03.04/phw LED light LED flashing Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: 11.08.04/phw Last change: 29.11.04/phw