Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 36A2211 Art.-Code: 131709 59,6 • Specification 2.11 / Mini-Module 52 • Standard addressing mode as S-slave; up to 31 modules 27,2 14 LED's • Spring loaded terminals (cage clamp) 18 36 3 4 ø 5,2 2 4,4 1 7,6 • Power supply for sensors and actuators via bus max. 50 • Connection for two 3-wire sensors and two actuators - + • Profile S - 3.F.F 2,2 ø 2,8 to 5,0 13,6 ø 13 20,5 • Fault diagnosis LED‘s bus data voltage supply range supply current reverse polarity protection E/A configuration ID-Code / ID-2 code AS-i voltage indicator / error indicator inputs supply voltage for sensors short-circuit protection with feedback total current for sensors -25...+40 °C total current for sensors +40...+70 °C polarity of the inputs input current high / low input voltage high / low input indicator outputs switching element / polarity total current for actuators -25...+40 °C total current for actuators +40...+70 °C switching current per output lmax short-circuit protection with feedback watchdog for bus monitoring output indicator general protection class temperature range / storage temperature housing material mounting EMC certificate no. connection diagram 26,5 - 33,1 VDC ≤ 200 mA yes 3 HEX F HEX / F HEX green LED / red LED AS-i + AS-i AS-i - 18 - 30 VDC yes ≤ 170 mA minus total current actuators ≤ 130 mA minus total current actuators PNP ≥ 1,5 mA / ≤ 0,5 mA > 10 VDC / < 5 VDC yellow LED transistor / sourcing (PNP) ≤ 170 mA minus total current sensors ≤ 130 mA minus total current sensors 100 mA yes yes yellow LED + IN 1 + IN 2 IN D0 D1 D2 D3 0+ 0+ 0+ 0+ 3 OUT 4 general port assignment: D0, D1 input D2, D3 output possible conductor cross-sections: sensor terminals: 0,08...0,5 mm2 actuator terminals: 0,08...0,5 mm2 max. outer cable diameter: ø 2,8...5 mm diagnosis IP 65 (with EPDM cable) -25...+70 °C / -25...+85 °C PBT / PC (UL 94 V-0) screws (2 x M4) refer to the AS-i brochure 60202 ASI Error (green) (red) Status Description POWER OFF Address = 0 No data exchange No ASi power Address = 0 Watchdog activated, Address = 0 ok -Sensor supply overload -Sensor supply shorted -Actuator supply overload -Actuator supply shorted ok External RESET, overload Error actuators LED dark Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 03.12.03/rue Checked: 05.12.03/phw LED light LED flashing Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: 23.08.04/phw Last change: 29.11.04/phw Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 36A2221 Art.-Code: 148300 59,6 • Specification 2.11 / Mini-Module 52 • Extended addressing mode as A/B-slave; up to 62 modules 27,2 14 LED's • Spring loaded terminals (cage clamp) 18 36 3 4 ø 5,2 2 4,4 1 7,6 • Power supply for sensors and actuators via bus max. 50 • Connection for two 3-wire sensors and two actuators - + • Profile S - B.A.E 2,2 ø 2,8 to 5,0 13,6 ø 13 20,5 • Fault diagnosis LED‘s bus data voltage supply range supply current reverse polarity protection E/A configuration ID-Code / ID-2 code AS-i voltage indicator / error indicator inputs supply voltage for sensors short-circuit protection with feedback total current for sensors -25...+70 °C polarity of the inputs input current high / low input voltage high / low input indicator outputs switching element / polarity total current for actuators -25...+70 °C switching current per output Imax short-circuit protection with feedback watchdog for bus monitoring output indicator general protection class temperature range / storage temperature housing material mounting EMC certificate no. connection diagram 26,5 - 33,1 VDC ≤ 170 mA yes B HEX A HEX / E HEX green LED / red LED AS-i + AS-i AS-i - 18 - 30 VDC yes ≤ 125 mA minus total current actuators PNP ≥ 1,5 mA / ≤ 0,5 mA > 10 VDC / < 5 VDC yellow LED transistor / sourcing (PNP) ≤ 125 mA minus total current sensors 100 mA yes yes yellow LED IP 65 (with EPDM cable) -25...+70 °C / -25...+85 °C PBT / PC (UL 94 V-0) screws (2 x M4) refer to the AS-i brochure 60201 1 + IN 2 IN D0 D1 D2 D3 0+ 0+ 0+ 0+ 3 OUT 4 general port assignment: D0, D1 output D2, D3 input possible conductor cross-sections: sensor terminals: 0,08...0,5 mm2 actuator terminals: 0,08...0,5 mm2 max. outer cable diameter: ø 2,8...5 mm diagnosis ASI Error (green) (red) Status Description POWER OFF Address = 0 No data exchange No ASi power Address = 0 Watchdog activated, Adresse = 0 ok -Sensor supply overload -Sensor supply shorted -Actuator supply overload -Actuator supply shorted ok External RESET, overload Error actuators LED dark Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 03.12.03/rue Checked: 20.08.04/phw + IN LED light LED flashing Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: 23.08.04/phw Last change: 16.11.04/phw