LU01 Catalog Specification Sheet

© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02
■ Overview
■ Overview
4
The SITRANS LU01 is an ultrasonic long-range level controller
for liquids and solids in a single vessel up to 60 m (200 ft).
Handheld programmer shown is an accessory and must be
ordered separately.
■ Benefits
■ Benefits
• Single point, long-range level monitoring
• Easy to install; easy to program using removable infrared
keypad (optional)
• Compatible with all EchoMax transducers
• Backlit LCD display with reading in standard engineering units
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus compatible
• High/low alarms
■ Application
The system consists of a SITRANS LU01 monitor linked to a noncontacting ultrasonic transducer that can be mounted up to
365 m (1 200 ft) away. The SITRANS LU01 will measure distance, level or volume, and it features Sonic Intelligence echo
processing software for superior reliability.
Readings are displayed in user-selectable linear engineering
units on the backlit LCD.
Modules for popular industrial buses can be factory installed or
added later to meet changing needs. No external gateway is required, reducing hardware and cabling costs.
• Key Applications: chemical storage, liquid storage, bulk
solids storage (gravel, flour bins, grains, cereals), plastic
pellets
4/160
The SITRANS LU02 is a dual point ultrasonic long-range level
controller for liquids and solids in one or two vessels up to 60 m
(200 ft). Handheld programmer shown is an accessory and must
be ordered separately.
Siemens FI 01 · June 2015
• Dual point, long-range level monitoring
• Easy to install; easy to program using removable infrared
keypad (optional)
• Compatible with all EchoMax transducers
• Backlit LCD display with reading in standard engineering units
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus compatible
• High/low alarms
■ Application
SITRANS LU02 will measure liquids, solids or a combination of
both in one or two vessels of different sizes, shapes and configurations up to 60 m (200 ft).
The system uses ultrasonic technology to measure level, space,
distance, volume or average/differential. It features Sonic Intelligence echo processing software for superior reliability. Transducers can be mounted up to 365 m (1 200 ft) from the monitor.
Readings are displayed in user-selectable linear engineering
units on the backlit LCD.
• Key Applications: chemical storage, liquid storage, bulk
solids storage (gravel, flour bins, grains, cereals), plastic
pellets, tripper car
© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 60 m (1 ... 200 ft)
Measuring points
SITRANS LU01: Max. one point;
SITRANS LU02: Max. two points
Output signal
Ultrasonic transducer
EchoMax series, ST-H transducers
Relays
4 SPDT Form C relays, rated at 5 A at
250 V AC, resistive load
mA output
• Max. load
• Resolution
• Outputs
0/4 ... 20 mA, optically isolated
750 Ω, isolated, 30 V
0.1 % of range
SITRANS LU01: Max. one mA output
SITRANS LU02: Max. two mA outputs
Accuracy
Selection and Ordering data
Article No.
SITRANS LU01/LU02
Single or dual point ultrasonic long-range level
monitoring system for liquids and solids,
and ranges up to 60 m (200 ft).
7ML5004-
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Number of measuring points
LU01 version, 1 point
LU02 version, 2 points
1
2
Input voltage
100/115/200/230 V AC, voltage selector switch
18 ... 30 V DC
Feature software
Standard
A
0.25 % of range or 6 mm (0.24 inch),
whichever is greater
Resolution
0.1 % of measuring range or 2 mm
(0.08 inch), whichever is greater
Temperature compensation
-50 ... +150 ºC (-58 ... +302 ºF)
• Integral temperature sensor
• External TS-3 temperature sensor
(optional)
• Programmable fixed temperature
Enclosure
Wall mount
Wall mount, drilled, 6 x M20
Note: Cable glands are not included and should be
-20 ... +50 ºC (-4 ... +122 ºF)
Design
Weight
2.7 kg (6 lb)
Material (enclosure)
Polycarbonate
Degree of protection (wall mount)
IP65
4
1
Error in measurement
Ambient conditions
• Ambient temperature for enclosure
A
B
Application software
Standard
Data communications
No module (SmartLinx ready)
Rated operating conditions
777 77 77
0
1
3
ordered as a separate line on the order.
Approvals
CE, CSAUS/C, FM1)
CE
ATEX II 3D2)
A
B
C
1)
Available with enclosure option 1 only
2)
Available with enclosure option 3 only
Electrical connection
Ultrasonic transducer cable extension RG62-A/U coaxial cable with low
capacitance
mA output signal
2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8 760 or
equivalent is acceptable
Electrical connection and relay connection
Copper conductor according to local
requirements, rated 250 V
5A
Synchronization
Up to 16 LU01/LU02 units can be
synchronized together
Power supply
AC model
100/115/200/230 V AC ± 15 %,
50/60 Hz, 31 VA
DC model
18 ... 30 V DC, 25 W
Displays and controls
51 x 127 mm (2 x 5 inch) graphics
LCD with backlighting
Memory
EEPROM (non-volatile), no backup
battery required
Programming
Using removable programmer
(ordered separately) or
Dolphin Plus (option)
Certificates and approvals
CE, CSAUS/C, FM, ATEX II 3D
Lloyd's register of Shipping
(Categories ENV1, ENV2, ENV3 and
ENV5)
Options
External temperature sensor
TS-3
Communications
Dolphin Plus: Siemens Windowscompatible interface and ComVerter
link (infrared)
Siemens FI 01 · June 2015
4/161
© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Accessories
Handheld programmer
7ML1830-2AN
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosures
7ML1930-1AC
M20 cable gland kit (6 M20 cable glands,
6 M20 nuts, 3 stop plugs)
7ML1830-1GM
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Operating Instructions
SITRANS LU01
Article No.
English
7ML1998-5BE02
TS-3 Temperature Sensor - see TS-3 on page 4/189
7ML1830-2AN
French
7ML1998-5BE12
Sunshield kit, 304 stainless steel
7ML1930-1GA
German
7ML1998-5BE32
Spare parts
Card, LU01 mother main, AC, comm ready
7ML1830-1KX
English
7ML1998-5BD02
Card, LU02 mother main, AC, comm ready
7ML1830-1MA
French
7ML1998-5BD12
Card, LU02 daughter, comm ready
7ML1830-1LP
German
Note: The Operating Instructions should be
ordered as a separate line item.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5BD32
Card, LU01 daughter, comm ready
7ML1830-1LN
Card, display
See SmartLinx product page 4/362 for
more information.
7ML1830-1LQ
SITRANS LU02
■ Dimensional drawings
106
(4.2)
92
(3.6)
285 (11.2)
267 (10.5)
2
3
267 (10.5)
100
%
209 (8.2)
1
4
0
1
2
3
4
5
6
7
8
mA
9
C
0
P
P
XX
1
2
3
1
2
3
5
6
7
8
9
0
P
P
mA
4
XX
%
SITRANS LU 02
Mounting hole
4.3 (0.17) diameter
access under lid
(4 places)
Suitable location for conduit entrances. Use
water-tight conduit hubs to maintain enclosure
rating.
Dimensional drawings for SITRANS LU01 (left) and SITRANS LU02 (right), dimensions in mm (inch)
Siemens FI 01 · June 2015
0
C
SITRANS LU 01
4/162
100
4
%
Suitable location for conduit entrances. Use
water-tight conduit hubs to maintain enclosure
rating.
106
(4.2)
92
(3.6)
285 (11.2)
172 (6.8)
209 (8.2)
%
172 (6.8)
4
Article No.
Selection and Ordering data
Mounting hole
4.3 (0.17) diameter
access under lid
(4 places)
© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02
■ Schematics
AC model
16
17
1
1
2
Temp. Temp.
sensor sensor
2
15
18
19
20
21
22
23
24
25
26
2
3
4
Relays
Note 3
27
1
28
2
TX
Note 2
RS 485
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
RS 232
B A
32
33
SYNC
14
SHLD
13
COM
12
SHLD
11
COM
1
Note 1
10
SHLD
mA
outputs
9
SHLD
2
8
SHLD
7
SHLD
6
BLK
1
5
WHT/SHLD
4
–
BLK
3
+
BLK
WHT/SHLD
2
–
WHT/SHLD
BLK
1
+
WHT/SHLD
Note 4
34
35
36
37
L2/N L1
Position SW1
for 100/115/
200/230 V AC
Operation
(50/60 Hz
31 VA)
RS 485
DC model
16
17
1
1
2
Temp. Temp.
sensor sensor
2
15
18
19
20
21
22
23
24
25
26
2
3
4
Relays
Note 3
27
1
28
2
TX
Note 2
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
RS 232
B A
32
33
SYNC
14
SHLD
13
COM
12
34
35
36
37
–
+
24 V
SHLD
11
SHLD
1
Note 1
10
COM
mA
outputs
9
SHLD
2
8
SHLD
7
SHLD
6
BLK
1
5
WHT/SHLD
4
–
BLK
3
+
BLK
WHT/SHLD
2
–
WHT/SHLD
BLK
1
+
WHT/SHLD
Note 4
Notes:
1. Optically isolated, 750 Ω max. load
2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1 200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated
limiting fuses are installed.
4. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect
all 'SYNC' terminals with a single 18 AWG (0.5 mm 2) wire.
SITRANS LU01 connections
AC model
17
18
19
20
21
22
23
24
25
26
2
3
4
Relays
Note 3
27
1
28
2
TX
Note 2
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
RS-232
B A
32
33
SYNC
16
1
1
2
Temp. Temp.
sensor sensor
2
15
SHLD
14
COM
13
SHLD
1
Note 1
12
COM
mA
outputs
11
SHLD
2
10
SHLD
1
9
SHLD
–
8
SHLD
+
7
BLK
–
6
WHT/SHLD
+
5
BLK
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
WHT/SHLD
Note 4
1
34
35
36
37
L2/N L1
Position SW1
for 100/115/
200/230 V AC
Operation
(50/60 Hz
31 VA)
RS-485
DC model
2
1
2
Temp. Temp.
sensor sensor
16
17
18
19
20
21
22
23
24
25
26
1
2
3
Relays
Note 3
Note 2
4
27
1
28
2
TX
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
32
33
SYNC
15
SHLD
14
COM
1
13
SHLD
Note 1
12
SHLD
mA
outputs
11
COM
2
10
SHLD
1
9
SHLD
–
8
SHLD
+
7
BLK
–
6
WHT/SHLD
+
5
BLK
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
WHT/SHLD
Note 4
1
RS-232
B A
34
35
36
37
–
+
24 V
RS-485
Notes:
1. Optically isolated, 750 Ω max. load
2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1 200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated
limiting fuses are installed.
4. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect
all 'SYNC' terminals with a single 18 AWG (0.5 mm 2) wire.
SITRANS LU02 connections
Siemens FI 01 · June 2015
4/163
4