Signal converters in 6 mm width Contents Signal converters in 6 mm width Signal converters in 6 mm width 2028820000 Universal signal converter in 6 mm width – Overview C.2 ACT20M – Overview C.4 CH20M rail bus C.26 MCZ-SERIES – Overview C.30 MCZ SERIES – DC/DC passive isolator C.32 MCZ-SERIES – PT100 /RTD signal converter C.33 MCZ-SERIES – Frequency signal converter C.34 MCZ-SERIES – Threshold monitoring C.35 C C.1 Signal converters in 6 mm width Universal signal converter in 6 mm width – Overview Analogue signal converter in 6 mm width The thinnest signal converter for isolating, converting and monitoring analogue signals The signal converters and the signal separators in the product family ACT20M, MICROSERIES and the MCZ enables the user to integrate many signal channels within a compact space. In addition to galvanic separation, these products offer the conversion and conditioning of DC and C C.2 temperature signals (TC and RTD) to standard norm signals (e.g. 4…20 mA, 0…10 V). The pluggable cross-connections option for MAS/MAZ and MCZ ranges, or the Weidmüller rail bus option for the ACT20M ensure a quick installation. 2028820000 Signal converters in 6 mm width Universal signal converter in 6 mm width – Overview C =RQH &ODVV'LY ACT20M MCZ-SERIES 2028820000 C.3 Signal converters in 6 mm width ACT20M – Overview ACT20M – a narrow 6 mm signal converter The new dimension for converting and isolating – housed in a 6 mm width The new ACT20M range combines innovative technologies with the highest levels of functionality in an electronics housing measuring just 6 mm in width. Up to two channels per module result in space savings in the electrical cabinet. The high electrical isolation of 2.5 kV and an accuracy of up to 0.05 % both help to ensure a high degree of process reliability. C C.4 The product line consists of Input Loop Powered, Output Loop Powered and Auxiliary Powered analog isolators and converters, including a universal input converter. The eight-connection housing allows additional functionality such as 2 channel ILP, 2 channel OLP isolation and signal splitting with input powering option. The configuration is carried out via DIP switches or the FDT/ DTM software. The ACT20M modules are supplied via direct wiring or a rail bus. 2028820000 Signal converters in 6 mm width ACT20M – Overview The DIP switch can be configured simply on the module In the “ACT20M Tool” software, simply select the type of input and output, and set the DIP switch configuration as displayed. C Easy configuration DIP switches on the side are used to configure the input and output parameters, as well as the response time. Signal splitter Signal converter High level of galvanic isolation U, I, R, T U,I PS 2.5 kV of electrical isolation (300 V rated voltage) ensures excellent process reliability. Universal measurement and signal converter Installation is simple and quick The power supply is simply snapped onto the rail bus for fast and easy installation. The supply can be through any ACT20M module or a separate power-feed unit. \ ; Passive isolator Temperature transducer Approvals Fulfils the strict standards and requirements of the process industry. Can be used worldwide due to international and local approvals ATEX, IECEX, CULUS, FM, GL and DNV. CH20M rail bus Power-feed modules 2028820000 C.5 Signal converters in 6 mm width ACT20M - Overview ACT20M – Selection table Current Power supply C 0 … 20 mA 24 V DC and rail bus Function 0 … 20 mA 1-channel 4 … 20 mA 1-channel universal ACT20M-UI-AO-S ACT20M-UI-AO-S 2 x 0 … 20 mA 2-channel / splitter 2 x 4 … 20 mA 2-channel / splitter U/I ACT20M-AI-2AO-S ACT20M-AI-2AO-S Current ACT20M-CI-2CO-S ACT20M-CI-2CO-S U/I ACT20M-AI-AO-E-S ACT20M-AI-AO-E-S U/I ACT20M-AI-AO-S ACT20M-AI-AO-S Current ACT20M-CI-CO-S ACT20M-CI-CO-S U/I Input Loop Powered Current Output Loop Powered Current ACT20M-CI-CO-OLP-S Current 2 x 0 … 20 mA Current Current 24 V DC Current 24 V DC and rail bus Current 4 … 20 mA Output Loop Powered Input Loop Powered universal ACT20M-2CI-2CO-OLP-S ACT20M-UI-AO-S ACT20M-UI-AO-S U/I ACT20M-AI-2AO-S ACT20M-AI-2AO-S Current ACT20M-CI-2CO-S ACT20M-CI-2CO-S U/I ACT20M-AI-AO-E-S ACT20M-AI-AO-E-S U/I ACT20M-AI-AO-S ACT20M-AI-AO-S Current ACT20M-CI-CO-S ACT20M-CI-CO-S U/I 1 x 4 … 20 mA Output Loop Powered Current ACT20M-CI-CO-OLP-S Input Current 2 x 4 … 20 mA Output Loop Powered Current 24 V DC Current Input Loop Powered Current ACT20M-2CI-2CO-OLP-S Current ACT20M-2CI-2CO-ILP-S ACT20M-2CI-2CO-ILP-S 1 x 4 … 20 mA Input Loop Powered Current ACT20M-CI-CO-ILP-S –10 mA…0…10 mA 24 V DC and rail bus bipolar ACT20M-BAI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S –20 mA…0…20 mA 24 V DC and rail bus bipolar ACT20M-BAI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S with sensor power supply 24 V DC and rail bus 0…5V 1…5V 24 V DC and rail bus Current ACT20M-CI-CO-ILP-S universal ACT20M-UI-AO-S ACT20M-UI-AO-S U/I ACT20M-AI-AO-S ACT20M-AI-AO-S universal ACT20M-UI-AO-S ACT20M-UI-AO-S U/I ACT20M-AI-AO-E-S ACT20M-AI-AO-E-S U/I ACT20M-AI-AO-S ACT20M-AI-AO-S U/I Voltage Output Loop Powered 0 …10 V 2 … 10 V 24 V DC and rail bus U/I universal ACT20M-UI-AO-S ACT20M-UI-AO-S U/I ACT20M-AI-AO-E-S ACT20M-AI-AO-E-S U/I ACT20M-AI-AO-S ACT20M-AI-AO-S U/I Output Loop Powered U/I –5 V … 0 … 5 V 24 V DC and rail bus bipolar ACT20M-BAI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S –10 V… 0 …10 V 24 V DC and rail bus bipolar ACT20M-BAI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S bipolar Note: C.6 *) available from July 2013 2028820000 Signal converters in 6 mm width ACT20M - Overview Output Voltage –10 mA … 0 … 10 mA 1-channel bipolar –20 mA … 0 … 20 mA 1-channel bipolar 0…5V/1…5V 1-channel 0 … 10 V / 2 … 10 V 1-channel ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-AI-AO-E-S ACT20M-AI-AO-E-S ACT20M-AI-AO-S ACT20M-AI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-AI-AO-E-S ACT20M-AI-AO-E-S ACT20M-AI-AO-S ACT20M-AI-AO-S 2x0…5V/2x1…5V 2-channel / splitter 2 x 0 … 10 V / 2 x 2 … 10 V -10 V… 0 … 10 V 2-channel / splitter 1-channel ACT20M-AI-2AO-S ACT20M-AI-2AO-S ACT20M-AI-2AO-S ACT20M-AI-2AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S ACT20M-BAI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S ACT20M-BAI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-AI-AO-S ACT20M-AI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-AI-AO-E-S ACT20M-AI-AO-E-S ACT20M-AI-AO-S ACT20M-AI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-AI-AO-E-S ACT20M-AI-AO-E-S ACT20M-AI-AO-S ACT20M-AI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S ACT20M-BAI-AO-S ACT20M-BAI-AO-S ACT20M-BAI-2AO-S ACT20M-BAI-2AO-S 2028820000 C C.7 Signal converters in 6 mm width ACT20M - Overview ACT20M – Selection table Current C PT100 Power supply Function Output Loop Powered Temp. 0 … 20 mA 1-channel 2-, 3-, 4-conductor Input 24 V DC and rail bus C.8 universal ACT20M-UI-AO-S ACT20M-UI-AO-S Temp. ACT20M-RTI-AO-S ACT20M-RTI-AO-S Temp. PT1000 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S Ni100 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S NI1000 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S B 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S E 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S J Output Loop Powered Temp. 24 V DC Temp. ACT20M-TCI-AO-E-S ACT20M-TCI-AO-E-S 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S Temp. ACT20M-TCI-AO-S ACT20M-TCI-AO-S ACT20M-RTI-AO-S ACT20M-RTI-AO-S ACT20M-RTCI-CO-OLP-S Temp. Temp. K ACT20M-RTCI-CO-OLP-S Output Loop Powered Temp. 24 V DC and rail bus Temp. ACT20M-TCI-AO-E-S ACT20M-TCI-AO-E-S universal ACT20M-UI-AO-S ACT20M-UI-AO-S Temp. ACT20M-TCI-AO-S ACT20M-TCI-AO-S Temp. ACT20M-RTI-AO-S ACT20M-RTI-AO-S TC Note: ACT20M-RTI-AO-E-S Temp. 24 V DC Poti R 2 x 4 … 20 mA 2-channel / splitter ACT20M-RTI-CO-EOLP-S ACT20M-RTI-AO-E-S Temp. 2 x 0 … 20 mA 2-channel / splitter ACT20M-RTCI-CO-OLP-S Temp. 24 V DC 4 … 20 mA 1-channel Temp. L 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S LR 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S N 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S R 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S S 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S T 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S U 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S W3 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S W5 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S 10R …100k 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S 10R …100k 24 V DC and rail bus universal ACT20M-UI-AO-S ACT20M-UI-AO-S *) available from July 2013 2028820000 Signal converters in 6 mm width ACT20M - Overview Output Voltage –10 mA … 0 … 10 mA 1-channel bipolar 2028820000 –20 mA … 0 … 20 mA 1-channel bipolar 0…5V/1…5V 1-channel 0 … 10 V / 2 … 10 V 1-channel ACT20M-RTI-AO-E-S ACT20M-RTI-AO-E-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-RTI-AO-S ACT20M-RTI-AO-S ACT20M-RTCI-AO-S ACT20M-RTCI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-TCI-AO-E-S ACT20M-TCI-AO-E-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-TCI-AO-S ACT20M-TCI-AO-S ACT20M-RTI-AO-S ACT20M-RTI-AO-S ACT20M-TCI-AO-E-S ACT20M-TCI-AO-E-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-TCI-AO-S ACT20M-TCI-AO-S ACT20M-RTI-AO-S ACT20M-RTI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S ACT20M-UI-AO-S 2x0…5V/2x1…5V 2-channel / splitter 2 x 0 … 10 V / 2 x 2 … 10 V -10 V… 0 … 10 V 2-channel / splitter 1-channel C C.9 Signal converters in 6 mm width ACT20M Signal splitter ACT20M-CI-2CO-S • Isolation and doubling of DC signals • Power supply via the mounting rail bus • 4-way isolation + - Input Output ch. 1 + mA - Output ch. 2 Supply + mA - + - Supply I IN C I OUT 2 4 5 3 6 2 7 1 82 83 I OUT 1 Supply 8 PLC 24 V DC 230 V AC Supply Technical data Electrical connections ACT20M-CI-2CO-S Input Input current Voltage drop, current input Output Output current load impedance current General data Configuration Supply voltage Ambient temperature Accuracy Temperature coefficient Cut-off frequency (-3 dB) Power consumption, typ. Power consumption, max. Step response time Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals 0...20 mA, 4…20mA < 1.5 V Terminal Input mA 0...20 mA, 4...20 mA < 300 Ω, per channel, @ max 23mA 1 2 3 4 5 6 7 8 ◼=+ ◻=– none 24 V DC ± 30 % -25 °C...70 °C < 0.05 % of measuring range ≤ 0.01 % / °C 100 Hz 400 mW 0.8 W ≤ 7 ms Power Supply Output 1 mA Output 2 mA ◻ ◼ ◻ ◼ ◼ ◻ ◼ ◻ 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II CE; cULus; DETNORVER; EAC; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Power supply optionally over the DIN mounting rail CH20M Ordering data Screw connection Type ACT20M-CI-2CO-S Qty. 1 Order No. 1175990000 Note Accessories Note C.10 DIN mounting rail, see Accessories 2028820000 Signal splitter Signal converters in 6 mm width ACT20M ACT20M-AI-2AO-S • Isolation, conversion and doubling of DC signals • Configuration via DIP switches • Power supply via the mounting rail bus • 4-way isolation • Support for adjustment by ACT20M Tool software, download link at www.weidmueller.com + - + + - Tx + mA - - Output ch. 1 + V Input Output ch. 2 Supply + + - - V mA + - Supply I, U 4 5 I, U IN 3 6 OUT 1 I, U 2 7 OUT 2 1 82 83 Supply 8 PLC 24 V DC C 230 V AC Supply Technical data Electrical connections ACT20M-AI-2AO-S Input Input current Input voltage Sensor supply Input resistance, voltage Voltage drop, current input Output Output current Output voltage load impedance current load impedance voltage General data Configuration Supply voltage Ambient temperature Accuracy Temperature coefficient Cut-off frequency (-3 dB) Power consumption, typ. Power consumption, max. Step response time Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals 0...20 mA, 4…20mA 0…10 V, 0…5 V > 17 V DC at 20 mA 500 kΩ < 1.5 V Input Terminal V 1 2 3 4 5 6 7 8 ◼=+ ◻=– adjustable, 0...20 mA, 4...20 mA adjustable, 0...10 V, 0...5 V < 300 Ω, per channel, @ max 23mA ≥ 10 kΩ DIP switch 24 V DC ± 30 % -25 °C...70 °C < 0.05 % of measuring range ≤ 0.01 % / °C 100 Hz 400 mW 1.2 W ≤ 7 ms ◼ ◻ mA mA Loop ◻ ◼ Output 1 Power supply V mA Output 2 V mA ◻ ◼ ◻ ◼ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ DIP switch settings Input Range 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II CE; cULus; DETNORVER; EAC; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX Output 1 Output 2 1 2 3 4 5 6 7 8 9 10 0 … 20 mA 4 … 20 mA 0 … 10 V 2 … 10 V 0…5V 1 …5 V 0 ... 20 mA loop ◼ 4 ... 20 mA loop ◼ ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◻ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◼ = on ◻ = off Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Power supply optionally over the DIN mounting rail CH20M Ordering data Screw connection Type ACT20M-AI-2AO-S Qty. 1 Order No. 1176020000 Note Accessories Note 2028820000 DIN mounting rail, see Accessories C.11 Signal converters in 6 mm width ACT20M Signal splitter ACT20M-BAI-2AO-S • Isolation and conversion of bipolar DC signals • Splitting into standard signal or bipolar output • Configuration via DIP switches • Power supply via the mounting rail bus • 4-way isolation • Support for adjustment by ACT20M Tool software, download link at www.weidmueller.com - + (±) + (±) - + V - Input + mA - Output ch. 1 Output ch. 2 Supply + + - - V mA + - Supply C I, U 4 5 I, U IN 3 6 OUT 1 I, U 2 7 OUT 2 1 82 83 Supply PLC 24 V DC 8 230 V AC Supply Technical data Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Electrical connections ACT20M-BAI-2AO-S -10 mA…0…+10 mA, -20 mA…0…+20 mA -5 V…0…+5 V, -10 V…0…+10 V Input Terminal V adjustable, 0...20 mA, 4...20 mA, ± 10mA, ± 20mA adjustable, 0...10 V, 0...5 V < 300 Ω, per channel ≥ 10 kΩ 1 2 3 4 5 6 7 8 ◼=+ ◻=– 24 V DC ± 30 % -25 °C...70 °C -40 °C...85 °C < 0.05 % of measuring range < 0.01% of span/°C (TU) ≥ 100 Hz, 10 Hz mA ◼ ◻ Output 1 Power supply V Output 2 mA V mA ◻ ◼ ◻ ◼ ◻ ◼ ◼ ◻ ◼ ◻ ◼ ◻ DIP switch settings 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II Range Bandwidth Input Input current Input voltage Output Output current Output voltage load impedance current load impedance voltage General data Supply voltage Ambient temperature Storage temperature Accuracy Temperature coefficient Cut-off frequency (-3 dB) Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals Approvals 1 cULus; DETNORVER; EAC; FMEX; GL; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 10 Hz 100 Hz -10...+10 mA -20...+20 mA -5...+5 V -10...+10 V 0 … 20 mA 4 … 20 mA 0 … 10 V 2 … 10 V 0…5V 1 …5 V ±20 mA set-up ±10 mA set-up Input Output 1 2 3 4 ◼ ◼ ◻ ◻ ◼ ◼ ◻ ◻ ◼ ◻ ◼ ◻ Output 2 5 6 7 8 9 10 ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◻ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◻ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◼ ◼ ◼ ◻ ◼ = on ◻ = off Ordering data Type ACT20M-BAI-2AO-S Qty. 1 Order No. 1375470000 Note Accessories Note C.12 DIN mounting rail, see accessories 2028820000 Signal isolator Signal converters in 6 mm width ACT20M ACT20M-CI-CO-S • Isolation of DC signals • Power supply via the mounting rail bus • 3-way isolation + - Input + mA - Output ch. 2 Output ch. 1 Supply + mA - + - Supply I IN 4 5 3 6 2 7 1 82 83 8 I OUT Supply PLC 24 V DC C 230 V AC Supply Technical data Electrical connections ACT20M-CI-CO-S Input Input current Voltage drop, current input Output Output current load impedance current General data Configuration Supply voltage Ambient temperature Accuracy Temperature coefficient Cut-off frequency (-3 dB) Power consumption, typ. Power consumption, max. Step response time Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals 0...20 mA, 4…20mA < 1.5 V Terminal Input mA 0...20 mA, 4...20 mA ≤ 600 Ω, @ max 23mA 1 2 3 4 5 6 7 8 ◼=+ ◻=– none 24 V DC ± 30 % -25 °C...70 °C < 0.05 % of measuring range ≤ 0.01 % / °C 100 Hz 400 mW 0.8 ≤ 7 ms Power Supply Output 1 mA ◻ ◼ ◼ ◻ ◼ ◻ 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II CE; cULus; DETNORVER; EAC; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Power supply optionally over the DIN mounting rail CH20M Ordering data Screw connection Type ACT20M-CI-CO-S Qty. 1 Order No. 1175980000 Note Accessories Note 2028820000 DIN mounting rail, see Accessories C.13 Signal converters in 6 mm width ACT20M Signal converter ACT20M-AI-AO-S • Isolation and conversion of DC signals • Configuration via DIP switches • Power supply via the mounting rail bus • 3-way isolation • Support for adjustment by ACT20M Tool software, download link at www.weidmueller.com + - + + - Tx + mA - Output ch. 1 + V Input - Output ch. 2 Supply + + - - V mA + - Supply I, U 4 5 I, U IN 3 6 OUT 2 7 C 1 82 83 PLC Supply 8 24 V DC 230 V AC Supply Technical data Electrical connections ACT20M-AI-AO-S Input Input current Input voltage Sensor supply Input resistance, voltage Voltage drop, current input Output Output current Output voltage load impedance current load impedance voltage General data Configuration Supply voltage Ambient temperature Accuracy Temperature coefficient Cut-off frequency (-3 dB) Power consumption, typ. Power consumption, max. Step response time Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals 0...20 mA, 4…20mA 0…10 V, 0…5 V > 17 V DC at 20 mA >500 kΩ <1,5 V Input Terminal 1 2 3 4 5 6 7 8 ◼=+ ◻=– adjustable, 0...20 mA, 4...20 mA adjustable, 0...10 V, 0...5 V ≤ 600 Ω, @ max 23mA ≥ 10 kΩ DIP switch 24 V DC ± 30 % -25 °C...70 °C < 0.05 % of measuring range ≤ 0.01 % / °C 100 Hz 400 mW 1.2 W ≤ 7 ms V mA mA Loop ◼ ◻ ◻ ◼ ◼ ◻ Output 1 Power supply V mA ◼ ◻ ◼ ◻ ◼ ◻ DIP switch settings Input Range 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II CE; cULus; DETNORVER; EAC; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX Output 1 2 3 4 5 6 7 0 … 20 mA 4 … 20 mA 0 … 10 V 2 … 10 V 0…5V 1 …5 V 0 ... 20 mA loop ◼ 4 ... 20 mA loop ◼ ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◻ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ 8 9 10 ◼ = on ◻ = off Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Power supply optionally over the DIN mounting rail CH20M Ordering data Screw connection Type ACT20M-AI-AO-S Qty. 1 Order No. 1176000000 Note Accessories Note C.14 DIN mounting rail, see Accessories 2028820000 Signal converter Signal converters in 6 mm width ACT20M ACT20M-AI-AO-E-S • Isolation and conversion of DC signals • Configuration via DIP switches • Power supply via the mounting rail bus • 3-way isolation • Support for adjustment by ACT20M Tool software, download link at www.weidmueller.com - + + - Input Output ch. 1 + + - - Supply V mA + - Supply I, U 4 5 I, U IN 3 6 OUT 2 7 1 82 83 PLC Supply 8 24 V DC C 230 V AC Supply Technical data Electrical connections ACT20M-AI-AO-E-S Input Input current Input voltage Input resistance, voltage Voltage drop, current input Output Output current Output voltage load impedance current load impedance voltage General data Configuration Supply voltage Ambient temperature Accuracy Temperature coefficient Cut-off frequency (-3 dB) Power consumption, typ. Power consumption, max. Step response time Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals 0...20 mA, 4…20mA 0…10 V, 0…5 V >500 kΩ <1,5 V Input Terminal 1 2 3 4 5 6 7 8 ◼=+ ◻=– adjustable, 0...20 mA, 4...20 mA adjustable, 0...10 V, 0...5 V ≤ 600 Ω, @ max 23mA ≥ 10 kΩ DIP switch 24 V DC ± 30 % 0 °C...70 °C < 0.2 % of measuring range ≤ 0.015 % / °C 100 Hz 400 mW 1.2 W ≤ 7 ms V mA ◼ ◻ ◻ ◼ Output 1 Power supply V mA ◼ ◻ ◼ ◻ ◼ ◻ DIP switch settings Input Range 1 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II CE; cULus; DETNORVER; EAC; GL; GOSTME25 0 … 20 mA 4 … 20 mA 0 … 10 V 2 … 10 V 0…5V 1 …5 V Output 2 3 4 5 6 7 ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ 8 9 10 ◼ = on ◻ = off Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Power supply optionally over the DIN mounting rail CH20M Ordering data Screw connection Type ACT20M-AI-AO-E-S Qty. 1 Order No. 1176010000 Note Accessories Note 2028820000 DIN mounting rail, see Accessories C.15 Signal converters in 6 mm width ACT20M Signal converter ACT20M-BAI-AO-S • Isolation and conversion of bipolar DC signals into standard signals • Configuration via DIP switches • Power supply via the mounting rail bus • 3-way isolation • Support for adjustment by ACT20M Tool software, download link at www.weidmueller.com - + (±) + (±) - + V - Input + mA - Output ch. 1 Output ch. 2 Supply + + - - mA V + - Supply I, U 4 5 I, U IN 3 6 OUT 2 7 C 1 82 83 PLC Supply 24 V DC 8 230 V AC Supply Technical data Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Electrical connections ACT20M-BAI-AO-S -10 mA…0…+10 mA, -20 mA…0…+20 mA -5 V…0…+5 V, -10 V…0…+10 V Input Terminal 0...20 mA, 4...20 mA adjustable, 0...10 V, 0...5 V ≤ 600 Ω ≥ 10 kΩ 1 2 3 4 5 6 7 8 ◼=+ ◻=– DIP switch 24 V DC ± 30 % -25 °C...70 °C -40 °C...85 °C < 0.05 % of measuring range < 0.01% of span/°C (TU) ≥ 100 Hz, 10 Hz V mA ◼ ◻ ◻ ◼ Output 1 Power supply V mA ◼ ◻ ◼ ◻ ◼ ◻ DIP switch settings 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II Range Bandwidth Input Input current Input voltage Output Output current Output voltage load impedance current load impedance voltage General data Configuration Supply voltage Ambient temperature Storage temperature Accuracy Temperature coefficient Cut-off frequency (-3 dB) Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals Approvals 1 cULus; DETNORVER; EAC; FMEX; GL; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 10 Hz 100 Hz -10...+10 mA -20...+20 mA -5...+5 V -10...+10 V 0 … 20 mA 4 … 20 mA 0 … 10 V 2 … 10 V 0…5V 1 …5 V ±20 mA set-up ±10 mA set-up Input Output 2 3 4 ◼ ◼ ◻ ◻ ◼ ◼ ◻ ◻ ◼ ◻ ◼ ◻ 5 6 7 ◻ ◻ ◼ ◼ ◼ ◼ ◻ ◼ ◻ ◼ ◻ ◼ ◻ ◻ ◻ ◻ ◼ ◼ 8 9 10 ◼ ◻ ◼ = on ◻ = off Power supply optionally via mounting rail bus CH20M Ordering data Type ACT20M-BAI-AO-S Qty. 1 Order No. 1375450000 Note Accessories Note C.16 Mounting rail bus, see accessories 2028820000 Universal measurement and signal converter ACT20M-UI-AO-S • Isolation and conversion of temperature signals and DC signals • Configuration using FDT/DTM software • Power supply via the mounting rail bus • 3-way isolation + + Tx - + - - - Output Input + Supply + - V + mA - + - Signal converters in 6 mm width ACT20M Supply + Tx I, U, R IN - 4 5 I, U 3 6 OUT 2 1 7 82 83 Supply PLC 24 V DC 8 + - Output Input Supply 230 V AC Supply + - V + mA - + - C Supply Technical data Electrical connections Input Sensor Thermocouples: B, E, J, K, L, LR, N, R, N, R, S, T, U, W3, W5, RTD: PT100, PT1000, Ni100, Ni1000, 2-/3-/4-wire 10 Ω…10 kΩ 10 Ω…10 kΩ 0...20 mA, 4…20mA 0…10 V, 0…5 V > 10 MΩ <3V > 15 V DC at 20 mA Potentiometer Resistance Input current Input voltage Input resistance, voltage Voltage drop, current input Sensor supply Output Output current Output voltage load impedance current load impedance voltage General data Configuration Supply voltage Ambient temperature Accuracy Temperature coefficient Power consumption, typ. Power consumption, max. Step response time Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals adjustable, 0...20 mA, 4...20 mA adjustable, 0...10 V, 0...5 V ≤ 600 Ω, @ max 28mA ≥ 10 kΩ ACT20M-UI-AO-S Input Terminal RTD mA V mA POT TC Loop 2 wire 3 wire 4 wire 1 2 ◻ ◻ 3 ◼ 4 ◼ 5 6 7 8 ◼=+ ◻=– R R Power supply Sense- Sense◼ RR- R ◻ R+ R+ R Sense+ R Output V mA ◻ ◻ ◼ ◼ ◻ ◻ ◼ ◻ With FDT/DTM software 24 V DC ± 30 % -25 °C...70 °C < 0.1 % of measuring range ≤ 0.01 % / °C 400 mW 1.2 W 400 ms (10...90%) @ U/I, 1 s @ temp 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II cULus; DETNORVER; EAC; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Power supply optionally over the DIN mounting rail CH20M Ordering data Screw connection Type ACT20M-UI-AO-S Qty. 1 Order No. 1176030000 Note Accessories Note 2028820000 CBX200 USB configuration adapter - 8978580000 DIN mounting rail, see Accessories C.17 Signal converters in 6 mm width ACT20M Passive isolator ACT20M-CI-CO-ILP-S • Isolation of DC signals without additional voltage supply • Supply from the input measuring circuit • Optionally available as a 1-channel / 2-channel version • 2-way isolation + - + - I IN 1 C I IN 2 24 V DC 4 5 3 6 2 7 1 8 I OUT 1 PLC I OUT 2 PLC Input ch. 1 Output ch. 1 Input ch. 2 Output ch. 2 + 0-20mA RLoad - + 0-20mA RLoad - 230 V AC Technical data Electrical connections ACT20M-CI-2CO-S Input Voltage drop, current input Input current Output Output current load impedance current General data Configuration Ambient temperature Accuracy Temperature coefficient Cut-off frequency (-3 dB) Power consumption, max. Supply voltage Step response time Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals 1.25 V + 0.015 Vout @25°C 0...20 mA, 4…20mA Terminal 0...20 mA, 4...20 mA ≤ 600 Ω, @ max 23mA 1 2 3 4 5 6 7 8 none -25 °C...70 °C < 0.1 % of measuring range ≤ 0.01 % / °C 100 Hz 30 mW per channel Loop powered, via 4...20 mA input ≤ 5 ms Input 1 Output 1 mA mA Input 2 Output 2 mA mA ◻ ◼ ◻ ◼ ◼ ◻ ◼ ◻ Electrical connections ACT20M-CI-CO-ILP-S 2.5 kVeff 300 Veff IEC 61326-1, NE 21 2 II cULus; DETNORVER; EAC; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX Terminal 1 2 3 4 5 6 7 8 ◼=+ ◻=– Input 1 Output 1 mA mA ◻ ◼ ◼ ◻ Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Power supply optionally over the DIN mounting rail CH20M Ordering data 1-channel version 2-channel version Type ACT20M-CI-CO-ILP-S ACT20M-2CI-2CO-ILP-S Qty. 1 1 Order No. 1176070000 1176080000 Note Accessories Note C.18 DIN mounting rail, see Accessories 2028820000 Passive isolator Signal converters in 6 mm width ACT20M ACT20M-CI-CO-OLP-S • Isolation of DC signals without additional voltage supply • Supply from the output measurement circuit • Optionally available as a 1-channel / 2-channel version • 2-way isolation + - + Tx Tx - I IN 1 I IN 2 4 5 3 6 2 7 1 8 I OUT 1 Input ch. 1 Output ch. 1 Input ch. 2 Output ch. 2 +24VDC + 4-20mA - +24VDC + 4-20mA - PLC C I OUT 2 24 V DC 230 V AC Technical data Electrical connections ACT20M-2CI-2CO-OLP-S Input Voltage drop, current input Input current Output Output current General data Configuration Ambient temperature Accuracy Temperature coefficient Typical 2.5 V 4...20 mA Terminal 4...20 mA 1 2 3 4 5 6 7 8 none -25 °C...70 °C < 0.05 % of measuring range ≤± 0.07 µA x (Δ °C x V supply) @ Tamb < 25 °C , ≤±0.02 µA x (Δ °C x V supply) @ Tamb > 25 °C 100 Hz 30 mW per channel Output loop powered ≤ 5 ms Cut-off frequency (-3 dB) Power consumption, max. Supply voltage Step response time Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals Input 1 Output 1 mA mA Input 2 Output 2 mA mA ◻ ◼ ◻ ◼ ◼ ◻ ◼ ◻ Electrical connections ACT20M-CI-CO-OLP-S 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II cULus; DETNORVER; EAC; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX Terminal 1 2 3 4 5 6 7 8 ◼=+ ◻=– Input 1 Output 1 mA mA ◻ ◼ ◼ ◻ Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Power supply optionally over the DIN mounting rail CH20M Ordering data 1-channel version 2-channel version Type ACT20M-CI-CO-OLP-S ACT20M-2CI-2CO-OLP-S Qty. 1 1 Order No. 1176040000 1176050000 Note Accessories Note 2028820000 DIN mounting rail, see Accessories C.19 Signal converters in 6 mm width ACT20M Temperature transducer ACT20M-RTCI-CO-OLP-S • Isolation and conversion of temperature signals, (RTD and thermocouple) • Configuration via DIP switches • Power supply via the output circuit • 2-way isolation 4 3 + +24VDC 4-20mA * * optional external Cold Junction Compensation (CJC) 4 5 I, U 3 6 OUT - 6 Input - IN 2 7 1 8 PLC 2 C 1 24 V DC 230 V AC Technical data Input Sensor Input measurement range Temperature input range Output Output current Sensor error detection General data Configuration Supply voltage Power consumption Storage temperature Accuracy Galvanic isolation Step response time Ambient temperature Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Electrical connections PT100 / 2-/3-/4-wire, Thermocouple acc. to IEC 584, type: J, Thermocouple acc. to IEC 584, type: K PT100 -200…+850 °C, Thermocouple type J -100…+1200°C, Thermocouple type K -200…+1370°C Configurable, min. measurement range 10°C (RTD), min. measurement range 50°C (TC) adjustable, 4...20 mA, 20…4 mA 3.5 mA ⁄ 23 mA ⁄ none DIP switch Output loop powered, 6…35 V ca. 1 W -40 °C...85 °C absolute accuracy: < ±0.05 % of the measurement range, RTD (PT100) Basic accuracy: < ±0.1 °C of the measurement range, TC (J,K) Basic accuracy: < ±0.5 °C of the measurement range 2-way isolator ≤ 30 ms, < 300 ms -25 °C...+70 °C 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II cULus; DETNORVER; EAC; FMEX; GL; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Ordering data Type ACT20M-RTCI-CO-OLP-S Note Accessories Note C.20 + 5 Output DIN mounting rail, see accessories Qty. 1 Order No. 1435590000 ACT20M-RTCI-CO-OPL-S Input Terminal RTD 2 wire 3 wire 4 wire R R SenseRR+ SenseRR+ Sense+ 1 2 3 4 5 6 7 8 * optional ◼=+ ◻=– Configuration Output 1 TC mA CJC+* TC-/CJC-* TC+ CJC-* ◼ ◻ Temperature range [°C] Pt100: -200...+850 °C // TC J: -100...+1200°C // TC K: -180...+1372 °C Min. S2 Max. S2 Max. S2 Temp. 1 2 3 4 Temp. 5 6 7 8 9 10 Temp. 5 6 7 8 9 10 -200 0 170 ◼ -180 ◼ 5 ◼ 180 ◼ ◼ -150 ◼ 10 ◼ 190 ◼ ◼ -100 ◼ ◼ 15 ◼ ◼ 200 ◼ ◼◼ -50 ◼ 20 ◼ 225 ◼ ◼ -25 ◼ ◼ 25 ◼ ◼ 250 ◼ ◼ ◼ -10 ◼◼ 30 ◼◼ 275 ◼ ◼◼ -5 ◼ ◼ ◼ 35 ◼ ◼ ◼ 300 ◼ ◼◼◼ 0 ◼ 40 ◼ 325 ◼ ◼ 5 ◼ ◼ 45 ◼ ◼ 350 ◼ ◼ ◼ 10 ◼ ◼ 50 ◼ ◼ 375 ◼ ◼ ◼ 20 ◼ ◼ ◼ 55 ◼ ◼ ◼ 400 ◼ ◼ ◼ ◼ 25 ◼ ◼ 60 ◼◼ 450 ◼ ◼ ◼ 50 ◼ ◼ ◼ 65 ◼ ◼ ◼ 500 ◼ ◼ ◼ ◼ 100 ◼ ◼ ◼ 70 ◼◼◼ 550 ◼ ◼ ◼ ◼ 200 ◼ ◼ ◼ ◼ 75 ◼ ◼ ◼ ◼ 600 ◼ ◼ ◼ ◼ ◼ 80 ◼ 650 ◼ ◼ 85 ◼ ◼ 700 ◼ ◼ ◼ 90 ◼ ◼ 750 ◼ ◼ ◼ 95 ◼ ◼ ◼ 800 ◼ ◼ ◼◼ 100 ◼ ◼ 850 ◼ ◼ ◼ 105 ◼ ◼ ◼ 900 ◼ ◼ ◼ ◼ 110 ◼ ◼◼ 950 ◼ ◼ ◼ ◼ 115 ◼ ◼ ◼ ◼ 1000 ◼ ◼ ◼ ◼ ◼ 120 ◼◼ 1050 ◼ ◼ ◼ 125 ◼◼ ◼ 1100 ◼ ◼ ◼ ◼ 130 ◼ ◼ ◼ 1150 ◼ ◼ ◼ ◼ 135 ◼ ◼ ◼ ◼ 1200 ◼ ◼ ◼ ◼ ◼ 140 ◼◼◼ 1250 ◼ ◼ ◼ ◼ 145 ◼ ◼ ◼ ◼ 1300 ◼ ◼ ◼ ◼ ◼ 150 ◼ ◼ ◼ ◼ 1350 ◼ ◼ ◼ ◼ ◼ 160 ◼ ◼ ◼ ◼ ◼ 1372 ◼ ◼ ◼ ◼ ◼ ◼ ◼ = On 2028820000 Temperature transducer ACT20M-RTI-CO-EOLP-S • Conversion of temperature signals, RTD • Configuration via DIP switches • Power supply via the output circuit 4 5 + +24VDC 4-20mA Output 3 6 - Input IN 4 5 I, U 3 6 OUT 2 7 1 8 PLC 2 C 1 24 V DC 230 V AC Technical data Input Sensor Input measurement range Temperature input range Output Output current Sensor error detection General data Configuration Supply voltage Power consumption Storage temperature Accuracy Galvanic isolation Step response time Ambient temperature EMC standards Approvals Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Electrical connections PT100 / 2-/3-/4-wire PT100 -200…+850 °C Configurable, min. measurement range 10°C (RTD) adjustable, 4...20 mA, 20…4 mA 3.5 mA ⁄ 23 mA ⁄ none DIP switch Output loop powered, 6…35 V ca. 1 W -40 °C...85 °C absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±0.2°C Without isolation ≤ 30 ms, < 300 ms -25 °C...+70 °C IEC 61326-1, NE 21 cULus; DETNORVER; EAC; FMEX; GL; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Type ACT20M-RTI-CO-EOLP-S Note Accessories 2028820000 DIN mounting rail, see accessories Qty. 1 ACT20M-RTCI-CO-OPL-S Input RTD Terminal Ordering data Note Signal converters in 6 mm width ACT20M Order No. 1435610000 1 2 3 4 5 6 7 8 * optional ◼=+ ◻=– Configuration 2 wire 3 wire 4 wire R R SenseRR+ SenseRR+ Sense+ Output 1 mA ◼ ◻ Temperature range [°C] Pt100: -200...+850 °C // TC J: -100...+1200°C // TC K: -180...+1372 °C Min. S2 Max. S2 Max. S2 Temp. 1 2 3 4 Temp. 5 6 7 8 9 10 Temp. 5 6 7 8 9 10 -200 0 170 ◼ -180 ◼ 5 ◼ 180 ◼ ◼ -150 ◼ 10 ◼ 190 ◼ ◼ -100 ◼ ◼ 15 ◼ ◼ 200 ◼ ◼◼ -50 ◼ 20 ◼ 225 ◼ ◼ -25 ◼ ◼ 25 ◼ ◼ 250 ◼ ◼ ◼ -10 ◼◼ 30 ◼◼ 275 ◼ ◼◼ -5 ◼ ◼ ◼ 35 ◼ ◼ ◼ 300 ◼ ◼◼◼ 0 ◼ 40 ◼ 325 ◼ ◼ 5 ◼ ◼ 45 ◼ ◼ 350 ◼ ◼ ◼ 10 ◼ ◼ 50 ◼ ◼ 375 ◼ ◼ ◼ 20 ◼ ◼ ◼ 55 ◼ ◼ ◼ 400 ◼ ◼ ◼ ◼ 25 ◼ ◼ 60 ◼◼ 450 ◼ ◼ ◼ 50 ◼ ◼ ◼ 65 ◼ ◼ ◼ 500 ◼ ◼ ◼ ◼ 100 ◼ ◼ ◼ 70 ◼◼◼ 550 ◼ ◼ ◼ ◼ 200 ◼ ◼ ◼ ◼ 75 ◼ ◼ ◼ ◼ 600 ◼ ◼ ◼ ◼ ◼ 80 ◼ 650 ◼ ◼ 85 ◼ ◼ 700 ◼ ◼ ◼ 90 ◼ ◼ 750 ◼ ◼ ◼ 95 ◼ ◼ ◼ 800 ◼ ◼ ◼◼ 100 ◼ ◼ 850 ◼ ◼ ◼ 105 ◼ ◼ ◼ 900 ◼ ◼ ◼ ◼ 110 ◼ ◼◼ 950 ◼ ◼ ◼ ◼ 115 ◼ ◼ ◼ ◼ 1000 ◼ ◼ ◼ ◼ ◼ 120 ◼◼ 1050 ◼ ◼ ◼ 125 ◼◼ ◼ 1100 ◼ ◼ ◼ ◼ 130 ◼ ◼ ◼ 1150 ◼ ◼ ◼ ◼ 135 ◼ ◼ ◼ ◼ 1200 ◼ ◼ ◼ ◼ ◼ 140 ◼◼◼ 1250 ◼ ◼ ◼ ◼ 145 ◼ ◼ ◼ ◼ 1300 ◼ ◼ ◼ ◼ ◼ 150 ◼ ◼ ◼ ◼ 1350 ◼ ◼ ◼ ◼ ◼ 160 ◼ ◼ ◼ ◼ ◼ 1372 ◼ ◼ ◼ ◼ ◼ ◼ ◼ = On C.21 Signal converters in 6 mm width ACT20M Temperature transducer ACT20M-RTI-AO-S • Isolation and conversion of temperature signals, RTD (PT100) • Configuration via DIP switches • Power supply via the mounting rail bus • 3-way isolation 4 5 Output 3 6 + + V mA - - Input 2 7 + 8 - Supply 1 Supply 4 IN C 3 2 5 I, U 6 OUT 7 1 82 83 Supply 8 PLC 24 V DC 230 V AC Supply Technical data Input Sensor Input measurement range Temperature input range Output Output current Output voltage load impedance current load impedance voltage Sensor error detection General data Configuration Supply voltage Power consumption Accuracy Galvanic isolation Temperature coefficient Step response time Ambient temperature Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Electrical connections ACT20M-RTI-AO-S PT100 / 2-/3-/4-wire PT100 -200…+850 °C Configurable, min. measurement range 10°C (RTD) 2 wire adjustable, 0...20 mA, 4...20 mA adjustable, 0...5 V, 0...10 V ≤ 600 Ω ≥ 10 kΩ 3.5 mA ⁄ 23 mA ⁄ none DIP switch 24 V DC ± 30 % 0.7 W absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.1°C 3-way isolator ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C ≤ 30 ms, < 300 ms -25 °C...+70 °C 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II cULus; DETNORVER; EAC; FMEX; GL; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Ordering data Type ACT20M-RTI-AO-S Note Accessories Note C.22 DIN mounting rail, see accessories Qty. 1 Input RTD Terminal Order No. 1375510000 1 2 3 4 5 6 7 8 ◼=+ ◻=– Configuration R R 3 wire 4 wire Power supply Output 1 V mA ◼ ◻ ◼ ◻ Sense- SenseRRR+ R+ Sense+ ◼ ◻ Temperature range [°C] Pt100: -200...+850 °C Min. S2 Max. S2 Max. S2 Temp. 1 2 3 4 Temp. 5 6 7 8 9 10 Temp. 5 6 7 8 9 10 -200 0 170 ◼ -180 ◼ 5 ◼ 180 ◼ ◼ -150 ◼ 10 ◼ 190 ◼ ◼ -100 ◼ ◼ 15 ◼ ◼ 200 ◼ ◼◼ -50 ◼ 20 ◼ 225 ◼ ◼ -25 ◼ ◼ 25 ◼ ◼ 250 ◼ ◼ ◼ -10 ◼◼ 30 ◼◼ 275 ◼ ◼◼ -5 ◼ ◼ ◼ 35 ◼ ◼ ◼ 300 ◼ ◼◼◼ 0 ◼ 40 ◼ 325 ◼ ◼ 5 ◼ ◼ 45 ◼ ◼ 350 ◼ ◼ ◼ 10 ◼ ◼ 50 ◼ ◼ 375 ◼ ◼ ◼ 20 ◼ ◼ ◼ 55 ◼ ◼ ◼ 400 ◼ ◼ ◼ ◼ 25 ◼ ◼ 60 ◼◼ 450 ◼ ◼ ◼ 50 ◼ ◼ ◼ 65 ◼ ◼ ◼ 500 ◼ ◼ ◼ ◼ 100 ◼ ◼ ◼ 70 ◼◼◼ 550 ◼ ◼ ◼ ◼ 200 ◼ ◼ ◼ ◼ 75 ◼ ◼ ◼ ◼ 600 ◼ ◼ ◼ ◼ ◼ 80 ◼ 650 ◼ ◼ 85 ◼ ◼ 700 ◼ ◼ ◼ 90 ◼ ◼ 750 ◼ ◼ ◼ 95 ◼ ◼ ◼ 800 ◼ ◼ ◼◼ 100 ◼ ◼ 850 ◼ ◼ ◼ 105 ◼ ◼ ◼ 900 ◼ ◼ ◼ ◼ 110 ◼ ◼◼ 950 ◼ ◼ ◼ ◼ 115 ◼ ◼ ◼ ◼ 1000 ◼ ◼ ◼ ◼ ◼ 120 ◼◼ 1050 ◼ ◼ ◼ 125 ◼◼ ◼ 1100 ◼ ◼ ◼ ◼ 130 ◼ ◼ ◼ 1150 ◼ ◼ ◼ ◼ 135 ◼ ◼ ◼ ◼ 1200 ◼ ◼ ◼ ◼ ◼ 140 ◼◼◼ 1250 ◼ ◼ ◼ ◼ 145 ◼ ◼ ◼ ◼ 1300 ◼ ◼ ◼ ◼ ◼ 150 ◼ ◼ ◼ ◼ 1350 ◼ ◼ ◼ ◼ ◼ 160 ◼ ◼ ◼ ◼ ◼ 1372 ◼ ◼ ◼ ◼ ◼ ◼ ◼ = On 2028820000 Temperature transducer Signal converters in 6 mm width ACT20M ACT-20M-RTI-AO-E-S • Conversion of temperature signals, RTD (PT100) • Configuration via DIP switches 4 5 Output 3 6 + + V mA - - Input 2 7 + 8 - Supply 1 4 IN 3 2 1 5 I, U 6 OUT 7 PLC 24 V DC Supply 8 Technical data Input Sensor Input measurement range Temperature input range Output Output current Output voltage load impedance current load impedance voltage Sensor error detection General data Configuration Supply voltage Power consumption Accuracy Galvanic isolation Temperature coefficient Step response time Ambient temperature EMC standards Approvals Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Electrical connections ACT20M-RTI-AO-E-S PT100 / 2-/3-/4-wire PT100 -200…+850 °C Configurable, min. measurement range 10°C (RTD) 2 wire adjustable, 0...20 mA, 4...20 mA adjustable, 0...5 V, 0...10 V ≤ 600 Ω ≥ 10 kΩ 3.5 mA ⁄ 23 mA ⁄ none DIP switch 24 V DC ± 30 % 0.7 W absolute accuracy: < ±0.1 % of the measurement range Without isolation ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C ≤ 30 ms, < 300 ms -25 °C...+70 °C IEC 61326-1, NE 21 cULus; DETNORVER; EAC; FMEX; GL; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Type ACT20M-RTI-AO-E-S Note Accessories 2028820000 DIN mounting rail, see accessories Qty. 1 Input RTD Terminal Ordering data Note C 230 V AC Order No. 1375520000 1 2 3 4 5 6 7 8 ◼=+ ◻=– Configuration R R 3 wire 4 wire Power supply Output 1 V mA ◼ ◻ ◼ ◻ Sense- SenseRRR+ R+ Sense+ ◼ ◻ Temperature range [°C] Pt100: -200...+850 °C Min. S2 Max. S2 Max. S2 Temp. 1 2 3 4 Temp. 5 6 7 8 9 10 Temp. 5 6 7 8 9 10 -200 0 170 ◼ -180 ◼ 5 ◼ 180 ◼ ◼ -150 ◼ 10 ◼ 190 ◼ ◼ -100 ◼ ◼ 15 ◼ ◼ 200 ◼ ◼◼ -50 ◼ 20 ◼ 225 ◼ ◼ -25 ◼ ◼ 25 ◼ ◼ 250 ◼ ◼ ◼ -10 ◼◼ 30 ◼◼ 275 ◼ ◼◼ -5 ◼ ◼ ◼ 35 ◼ ◼ ◼ 300 ◼ ◼◼◼ 0 ◼ 40 ◼ 325 ◼ ◼ 5 ◼ ◼ 45 ◼ ◼ 350 ◼ ◼ ◼ 10 ◼ ◼ 50 ◼ ◼ 375 ◼ ◼ ◼ 20 ◼ ◼ ◼ 55 ◼ ◼ ◼ 400 ◼ ◼ ◼ ◼ 25 ◼ ◼ 60 ◼◼ 450 ◼ ◼ ◼ 50 ◼ ◼ ◼ 65 ◼ ◼ ◼ 500 ◼ ◼ ◼ ◼ 100 ◼ ◼ ◼ 70 ◼◼◼ 550 ◼ ◼ ◼ ◼ 200 ◼ ◼ ◼ ◼ 75 ◼ ◼ ◼ ◼ 600 ◼ ◼ ◼ ◼ ◼ 80 ◼ 650 ◼ ◼ 85 ◼ ◼ 700 ◼ ◼ ◼ 90 ◼ ◼ 750 ◼ ◼ ◼ 95 ◼ ◼ ◼ 800 ◼ ◼ ◼◼ 100 ◼ ◼ 850 ◼ ◼ ◼ 105 ◼ ◼ ◼ 900 ◼ ◼ ◼ ◼ 110 ◼ ◼◼ 950 ◼ ◼ ◼ ◼ 115 ◼ ◼ ◼ ◼ 1000 ◼ ◼ ◼ ◼ ◼ 120 ◼◼ 1050 ◼ ◼ ◼ 125 ◼◼ ◼ 1100 ◼ ◼ ◼ ◼ 130 ◼ ◼ ◼ 1150 ◼ ◼ ◼ ◼ 135 ◼ ◼ ◼ ◼ 1200 ◼ ◼ ◼ ◼ ◼ 140 ◼◼◼ 1250 ◼ ◼ ◼ ◼ 145 ◼ ◼ ◼ ◼ 1300 ◼ ◼ ◼ ◼ ◼ 150 ◼ ◼ ◼ ◼ 1350 ◼ ◼ ◼ ◼ ◼ 160 ◼ ◼ ◼ ◼ ◼ 1372 ◼ ◼ ◼ ◼ ◼ ◼ ◼ = On C.23 Signal converters in 6 mm width ACT20M Temperature transducer ACT20M-TCI-AO-S • Isolation and conversion of temperature signals, (thermocouple) • Configuration via DIP switches • Power supply via the mounting rail bus • 3-way isolation 4 5 Output 3 + 6 + + V mA - - Input - 2 7 + 8 - Supply * 1 * optional external Cold Junction Compensation (CJC) Supply IN 4 5 I, U 3 6 OUT 2 C 7 1 82 83 8 Supply PLC 24 V DC 230 V AC Supply Technical data Input Sensor Input measurement range Temperature input range Output Output current Output voltage load impedance current load impedance voltage Sensor error detection General data Configuration Supply voltage Power consumption Accuracy Galvanic isolation Temperature coefficient Step response time Ambient temperature Insulation coordination Insulation voltage Rated voltage EMC standards Pollution degree Overvoltage category Approvals Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Electrical connections Thermocouple (type J, K) Thermocouple type J -100…+1200°C, Thermocouple type K -200…+1370°C Configurable, min. measurement range 50°C (TC) adjustable, 0...20 mA, 4...20 mA adjustable, 0...5 V, 0...10 V ≤ 600 Ω ≥ 10 kΩ 3.5 mA ⁄ 23 mA ⁄ none DIP switch 24 V DC ± 30 % 0.7 W absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.5° 3-way isolator 0,1 °C ⁄ °C, or, ≤0,01% des Messbereichs⁄°C ≤ 30 ms, < 300 ms, Configurable -25 °C...+70 °C 2.5 kVeff / 1 min. 300 Veff IEC 61326-1, NE 21 2 II cULus; DETNORVER; EAC; FMEX; GL; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Ordering data Type ACT20M-TCI-AO-S Note Accessories Note C.24 DIN mounting rail, see accessories Qty. 1 Order No. 1375480000 Terminal ACT20M-TCI-AO-S Power Output 1 supply V mA Input TC 1 2 3 4 5 6 7 8 CJC+ 1,2) TC-/CJC- 1,2) TC+ CJC- 1,2) 1) only 2) optional ◼ ◻ ◼ ◻ ◼ ◻ ◼=+ ◻=– Configuration Temperature range [°C] TC J: -100...+1200 °C // TC K: -180...+1372 °C Min. S2 Max. S2 Max. S2 Temp. 1 2 3 4 Temp. 5 6 7 8 9 10 Temp. 5 6 7 8 9 10 -200 0 170 ◼ -180 ◼ 5 ◼ 180 ◼ ◼ -150 ◼ 10 ◼ 190 ◼ ◼ -100 ◼ ◼ 15 ◼ ◼ 200 ◼ ◼◼ -50 ◼ 20 ◼ 225 ◼ ◼ -25 ◼ ◼ 25 ◼ ◼ 250 ◼ ◼ ◼ -10 ◼◼ 30 ◼◼ 275 ◼ ◼◼ -5 ◼ ◼ ◼ 35 ◼ ◼ ◼ 300 ◼ ◼◼◼ 0 ◼ 40 ◼ 325 ◼ ◼ 5 ◼ ◼ 45 ◼ ◼ 350 ◼ ◼ ◼ 10 ◼ ◼ 50 ◼ ◼ 375 ◼ ◼ ◼ 20 ◼ ◼ ◼ 55 ◼ ◼ ◼ 400 ◼ ◼ ◼ ◼ 25 ◼ ◼ 60 ◼◼ 450 ◼ ◼ ◼ 50 ◼ ◼ ◼ 65 ◼ ◼ ◼ 500 ◼ ◼ ◼ ◼ 100 ◼ ◼ ◼ 70 ◼◼◼ 550 ◼ ◼ ◼ ◼ 200 ◼ ◼ ◼ ◼ 75 ◼ ◼ ◼ ◼ 600 ◼ ◼ ◼ ◼ ◼ 80 ◼ 650 ◼ ◼ 85 ◼ ◼ 700 ◼ ◼ ◼ 90 ◼ ◼ 750 ◼ ◼ ◼ 95 ◼ ◼ ◼ 800 ◼ ◼ ◼◼ 100 ◼ ◼ 850 ◼ ◼ ◼ 105 ◼ ◼ ◼ 900 ◼ ◼ ◼ ◼ 110 ◼ ◼◼ 950 ◼ ◼ ◼ ◼ 115 ◼ ◼ ◼ ◼ 1000 ◼ ◼ ◼ ◼ ◼ 120 ◼◼ 1050 ◼ ◼ ◼ 125 ◼◼ ◼ 1100 ◼ ◼ ◼ ◼ 130 ◼ ◼ ◼ 1150 ◼ ◼ ◼ ◼ 135 ◼ ◼ ◼ ◼ 1200 ◼ ◼ ◼ ◼ ◼ 140 ◼◼◼ 1250 ◼ ◼ ◼ ◼ 145 ◼ ◼ ◼ ◼ 1300 ◼ ◼ ◼ ◼ ◼ 150 ◼ ◼ ◼ ◼ 1350 ◼ ◼ ◼ ◼ ◼ 160 ◼ ◼ ◼ ◼ ◼ 1372 ◼ ◼ ◼ ◼ ◼ ◼ ◼ = On 2028820000 Temperature transducer Signal converters in 6 mm width ACT20M ACT-20M-TCI-AO-E-S • Conversion of temperature signals, (thermocouple) • Configuration via DIP switches 4 5 Output 3 + 6 + + V mA - - Input - 2 7 + 8 - Supply 1 IN 4 3 2 1 5 I, U 6 OUT 7 Supply PLC 24 V DC 8 Technical data Input Sensor Input measurement range Temperature input range Output Output current Output voltage load impedance current load impedance voltage Sensor error detection General data Configuration Supply voltage Power consumption Accuracy Galvanic isolation Temperature coefficient Step response time Ambient temperature EMC standards Approvals Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Electrical connections Thermocouple (type J, K) Thermocouple type J -100…+1200°C, Thermocouple type K -200…+1370°C Configurable, min. measurement range 50°C (TC) adjustable, 0...20 mA, 4...20 mA adjustable, 0...5 V, 0...10 V ≤ 600 Ω ≥ 10 kΩ 3.5 mA ⁄ 23 mA ⁄ none DIP switch 24 V DC ± 30 % 0.7 W absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±1 °C Without isolation 0,1 °C ⁄ °C, or, ≤0,01% des Messbereichs⁄°C ≤ 30 ms, < 300 ms, Configurable -25 °C...+70 °C IEC 61326-1, NE 21 cULus; DETNORVER; EAC; FMEX; GL; IECEXKEM; KEMAATEX Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Ordering data Type ACT20M-TCI-AO-E-S Note Accessories Note 2028820000 C 230 V AC DIN mounting rail, see accessories Qty. 1 Order No. 1375500000 Terminal ACT20M-TCI-AO-E-S Power Output 1 supply V mA Input TC 1 2 3 4 5 6 7 8 CJC+ 1,2) TC-/CJC- 1,2) TC+ CJC- 1,2) 1) only 2) optional ◼ ◻ ◼ ◻ ◼ ◻ ◼=+ ◻=– Configuration Temperature range [°C] TC J: -100...+1200 °C // TC K: -180...+1372 °C Min. S2 Max. S2 Max. S2 Temp. 1 2 3 4 Temp. 5 6 7 8 9 10 Temp. 5 6 7 8 9 10 -200 0 170 ◼ -180 ◼ 5 ◼ 180 ◼ ◼ -150 ◼ 10 ◼ 190 ◼ ◼ -100 ◼ ◼ 15 ◼ ◼ 200 ◼ ◼◼ -50 ◼ 20 ◼ 225 ◼ ◼ -25 ◼ ◼ 25 ◼ ◼ 250 ◼ ◼ ◼ -10 ◼◼ 30 ◼◼ 275 ◼ ◼◼ -5 ◼ ◼ ◼ 35 ◼ ◼ ◼ 300 ◼ ◼◼◼ 0 ◼ 40 ◼ 325 ◼ ◼ 5 ◼ ◼ 45 ◼ ◼ 350 ◼ ◼ ◼ 10 ◼ ◼ 50 ◼ ◼ 375 ◼ ◼ ◼ 20 ◼ ◼ ◼ 55 ◼ ◼ ◼ 400 ◼ ◼ ◼ ◼ 25 ◼ ◼ 60 ◼◼ 450 ◼ ◼ ◼ 50 ◼ ◼ ◼ 65 ◼ ◼ ◼ 500 ◼ ◼ ◼ ◼ 100 ◼ ◼ ◼ 70 ◼◼◼ 550 ◼ ◼ ◼ ◼ 200 ◼ ◼ ◼ ◼ 75 ◼ ◼ ◼ ◼ 600 ◼ ◼ ◼ ◼ ◼ 80 ◼ 650 ◼ ◼ 85 ◼ ◼ 700 ◼ ◼ ◼ 90 ◼ ◼ 750 ◼ ◼ ◼ 95 ◼ ◼ ◼ 800 ◼ ◼ ◼◼ 100 ◼ ◼ 850 ◼ ◼ ◼ 105 ◼ ◼ ◼ 900 ◼ ◼ ◼ ◼ 110 ◼ ◼◼ 950 ◼ ◼ ◼ ◼ 115 ◼ ◼ ◼ ◼ 1000 ◼ ◼ ◼ ◼ ◼ 120 ◼◼ 1050 ◼ ◼ ◼ 125 ◼◼ ◼ 1100 ◼ ◼ ◼ ◼ 130 ◼ ◼ ◼ 1150 ◼ ◼ ◼ ◼ 135 ◼ ◼ ◼ ◼ 1200 ◼ ◼ ◼ ◼ ◼ 140 ◼◼◼ 1250 ◼ ◼ ◼ ◼ 145 ◼ ◼ ◼ ◼ 1300 ◼ ◼ ◼ ◼ ◼ 150 ◼ ◼ ◼ ◼ 1350 ◼ ◼ ◼ ◼ ◼ 160 ◼ ◼ ◼ ◼ ◼ 1372 ◼ ◼ ◼ ◼ ◼ ◼ ◼ = On C.25 Signal converters in 6 mm width CH20M rail bus CH20M rail bus Quick and safe power supply through the DIN rail. C This customer-friendly infrastructure solution brings power, signals and data to the rail in a quick and reliable manner. The rail bus can replace the tedious individual wiring process with a flexible and uninterrupted system solution. As a result, the customer saves time and cost-especially if any module changes are needed later, as other adjacent modules are not disturbed. The uninterrupted system bus is securely integrated within the 35 mm standard mounting rail. Whether 7.5 mm or 15 mm high, the custom-fit rail profiles are easy to install on all TS 35 standard rails in accordance with DIN EN 60715. The supply of 24 V DC to the power rail can be from any one of the auxiliary powered ACT20M modules, when that module is itself externally supplied. This allows the rail to power up to 8 other modules (approximately 400 mA). For powering additional ACT20Ms, a separate Feed-In module can be used. The ACT20-Feed-In-Basic provides a simple and compact (6 mm width) power supply interface to the rail, for supplying up to 2.5 A (up to 50 x ACT20M modules). The resistant gold-plated contacts ensure a permanent and reliable contact. The ACT20M modules are simply snapped onto the mounting rail and are automatically in contact with the DIN rail bus. The ACT20-Feed-In-Pro is a more powerful 22.5 mm wide solution. This takes 2 external 24 V DC inputs, and via internal diodes provides a redundant supply to the rail, and an alarm output in the case of input failure. C.26 2028820000 Signal converters in 6 mm width CH20M rail bus Rail bus accessories CH20M BUS-PROFIL TS35x7.5/1000 CH20M BUS-PROFIL TS35x15/1000 CH20M BUS 4.50/05 AU/1000 Support section for bus circuit board Support section for bus circuit board Bus PCB • Support section for TS 35 x 7.5 • Length: 250, 500 or 750 mm • Support section for TS 35 x 15 • Length: 250, 500 or 750 mm • Bus circuit board for use on TS 35 x 7.5 and TS 35 x 15 • Length: 250, 500 or 750 mm • Five conductor paths, gold-plated • Electrical rating: 63 V AC, 5 A/conductor path Ordering data Type CH20M BUS-PROFIL TS35x7.5/250 CH20M BUS-PROFIL TS35x7.5/500 CH20M BUS-PROFIL TS35x7.5/750 Qty. 10 10 5 Order No. 1248150000 1248160000 1248170000 Ordering data Type CH20M BUS-PROFIL TS35x15/250 CH20M BUS-PROFIL TS35x15/500 CH20M BUS-PROFIL TS35x15/750 Qty. 5 5 5 Order No. 1248180000 1248190000 1248210000 Ordering data Type CH20M BUS 4.50/05 AU/250 CH20M BUS 4.50/05 AU/500 CH20M BUS 4.50/05 AU/750 Qty. 10 10 5 CH20M BUS-ADP TS35/1000 CH20M BUS-AP LI TS35x7.5 & 15 CH20M BUS-AP RE TS35x7.5 & 15 Cover plate End plate End plate • Cover plate for DIN rail bus • Length: 250, 500 or 750 mm • End plate for DIN rail bus • Fits on TS 35 x 7.5 and TS 35 x 15 • left • End plate for DIN rail bus • Fits on TS 35 x 7.5 and TS 35 x 15 • right Ordering data Type CH20M BUS-ADP TS35/250 CH20M BUS-ADP TS35/500 CH20M BUS-ADP TS35/750 Qty. 10 10 5 Order No. 1248250000 1248260000 1248270000 Ordering data Type CH20M BUS-AP LI TS35x7.5 & 15 Qty. 50 Order No. 1193160000 Ordering data Type CH20M BUS-AP RE TS35x7.5 & 15 SET CH20M BUS 250MM TS 35X15 SET CH20M BUS 250MM TS 35X7.5 TS 35x7.5 / TS 35x15 Set Set DIN rail • SET consists of one each of CH20M BUS 4.50/05 AU/250 CH20M BUS-ADP TS 35/250 CH20M BUS-AP LI TS 35X7.5 & 15 CH20M BUS-AP RE TS 35X7.5 & 15 CH20M BUS-PROFIL TS 35X15/250 • SET consists of one each of CH20M BUS 4.50/05 AU/250 CH20M BUS-ADP TS 35/250 CH20M BUS-AP LI TS 35X7.5 & 15 CH20M BUS-AP RE TS 35X7.5 & 15 CH20M BUS-PROFIL TS 35X7.5/250 • DIN rail with slot • Passivated galvanised steel Ordering data Type SET CH20M BUS 250MM TS 35X15 2028820000 Qty. 1 Order No. 1335150000 Ordering data Type SET CH20M BUS 250MM TS 35X7.5 Qty. 1 Order No. 1335140000 Ordering data Type TS 35X7.5/LL 1M/ST/ZN TS 35X15/LL 1M/ST/ZN C Order No. 1248220000 1248230000 1248240000 Qty. 50 Order No. 1193170000 Qty. 10 10 Order No. 0514510000 0236510000 C.27 Signal converters in 6 mm width CH20M rail bus Power-feed module for the CH20M DIN rail bus 4 A supply with backup supply and error analysis C The power-feed unit ACT20-FEED-IN-PRO-S supplies the devices on the CH20M DIN rail bus with 24 V DC. At the same time, the FEED-IN device reads the group error contact – optionally provided by the installed devices – from the CH20M rail bus and sends a message through the status relay to the external controller. Optionally, two power supplies can be connected as a primary and back-up, to create a redundant 24 V DC source. An installation in Zone 2 / Division 2 is also possible. Three LEDs show the status of the power supply and the error status. The FEED-IN-PRO can supply a maximum of 4 A to feed up to 120 devices mounted on a CH20M rail bus. Quick identification of errors on the DIN rail bus is through the internal status relay. The FEED-IN-PRO device immediately recognises and displays when a power supply has failed. The supply is then switched automatically to the redundant power supply. C.28 Weidmüller offers a compact and narrow 6 mm feed-in module as an alternative. This feeds the 24 V DC from it‘s field terminals directly to the to the DIN rail bus. Up to 80 modules can be fed with a maximum available current of 2.5 A. 2028820000 ACT20 power-feed module ACT20-Feed-In-PRO-S Signal converters in 6 mm width ACT20 power-feed unit ACT20-Feed-In-BASIC-S • Distributes the supply onto the busbar • Compatible with Weidmüller CH20 DIN rail bus • Optional connection for backup supply • Approved for use in Ex-Zone 2 /Div. 2 • Monitoring of the supply voltage • Alarm alerts via the status relay Alarm Power supply, 0 V 51 44 NC Power supply,+24V 52 Power supply, +24 V 43 Status relay, N.C. Backup, +24 V 53 42 Status relay, shared Backup, 0 V 54 41 Status relay, N.O. C NC 0V NC +24 V 81 NC 82 Status 83 0V 84 +24 V NC NC 85 Power supply, 0 V Technical data Input Supply voltage Input current Trigger level for the power supply Output, power supply Output voltage Output power Output current Output, status relay in safe zone Max. switching voltage, AC / Max. switching voltage, DC Continuous current AC power, max. General data Degree of efficiency Ambient temperature Power consumption Protection degree Weight Humidity EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) Length x width x height Note 21.6...26.4 V DC Max. 4 A 21.6...26.4 V DC Fault < 21 V DC 21.6...26.4 V DC 0.5...2.5 A DC Input voltage -0.5 V DC / 4 A 96 W Max. 4 A Corresponds to the input voltage 250 V / 30 V 2 A AC / DC 500 VA / 60 W 250 V / 30 V 0,976 -20 °C...+60 °C <2W IP 20 140 95 %, no condensation IEC 61326-1, NE 21 cULus; DEKRAATEX; DETNORVER; EAC; FMEX; GOSTME25; IECEXDEK 100 % -25 °C...+70 °C Screw connection 2.5 / 0.5 / 2.5 / 22.5 / 117.2 Screw connection 2.5 / 0.5 / 2.5 / 6.1 / 112.5 Equivalent to input current IP 20 70 95 %, no condensation IEC 61326-1, NE 21 cULus; DETNORVER; EAC; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX Ordering data Screw connection Type ACT20-FEED-IN-PRO-S Qty. 1 Order No. 8965500000 Type ACT20-FEED-IN-BASIC-S Qty. 1 Order No. 1282490000 Note Accessories Note 2028820000 DIN mounting rail, see Accessories DIN mounting rail, see Accessories C.29 The MCZ-SERIES signal converters have a slim terminal design and convert, isolate and monitor analogue signals. They have five tension clamp connections. The open side of the housing can be closed using a standard cover plate accessory. The housing has a low height of just 6.3 cm. It also accommodates a cross-connector for reducing the wiring of multiple module‘s 24 V and 0 V connections. Two WS10/6 markers can be used for labelling. These are available in MultiCard format and can be printed using Weidmüller‘s professional printing system. Output Miscellaneous 8425720000 8483680000 8604420000 8473010000 8473020000 8473000000 8604430000 8411190000 8260280000 8227350000 8461480000 8461470000 C.30 Selection table for analog signal converter MCZ series MCZ PT100/3 CLP 0...100C 1 X MCZ PT100/3 CLP 0...120C 1 X MCZ PT100/3 CLP 0...150C 1 X MCZ PT100/3 CLP 0...200C 1 X MCZ PT100/3 CLP 0...300C 1 X MCZ PT100/3 CLP -50C...+150C 1 X MCZ PT100/3 CLP -40C...100C 1 X MCZ CCC 0-20mA/0-20mA 1 X X MCZ SC 0-10V 1 X MCZ SC 0-20MA 1 X MCZ CFC 0-20MA 1 X MCZ VFC 0-10V 1 X 6 6 6 6 6 6 6 6 6 6 6 6 1 1 1 1 1 1 1 1 X 2 2 1 1 X X X X X X X X Special characteristics output loop output loop output loop output loop output loop output loop output loop output loop Limit value transistor output potentiometer 24 V DC Limit value transistor output potentiometer 24 V DC 24 V DC Frequency: 0...1/ 4/ 8/ 16 kHz DIP switch 24 V DC Frequency: 0...1/ 4/ 8/ 16 kHz DIP switch 2-way 2-way 2-way 2-way 2-way 2-way 2-way 2-way 100 2-way 100 2-way Connection system Input Isolation Product Amount 0…20mA 4…20mA 0…10V RTD Frequency Sensor feed Width (mm) Amount 0…20mA 4…20mA Order No. Rated voltage (V) Selection table Auxiliary power C Signal converter in a terminal format Configuration Signal converters in 6 mm width MCZ-SERIES – Overview Z Z Z Z Z Z Z Z Z Z Z Z Passive converter OLP Passive converter OLP Passive converter OLP Passive converter OLP Passive converter OLP Passive converter OLP Passive converter OLP Passive converter OLP Frequency output configurable Frequency output configurable 2028820000 Signal converters in 6 mm width MCZ-SERIES – Overview Security U/I U/I VC m 6m Electrical isolation increases the safety of operations and reduces the risk of facility malfunctions. C Saves space in the electrical cabinet High product density (modules only 6 mm wide) reduces space taken on the DIN rail. Simple wiring The power supply can easily be bridged from one module to the next using pluggable cross-connections. DC/DC passive disconnector PT100 /RTD signal converter Frequency signal converter Threshold monitoring 2028820000 C.31 Signal converters in 6 mm width MCZ SERIES - DC/DC passive isolator Input current loop feed MCZ CCC / ILP • Passive isolators for galvanic isolation of 0/4...20 mA standard signals. • The component draws power from the measurement signal and requires no additional auxiliary power • Low energy consumption, pick-up current of < 100 µA. • 2-way isolation I C I Technical data / 0...20 mA current loop < 100 µA 2.5....3 V at 20 mA 15 12 / 0...20 mA, 4...20 mA / ≤ 500 Ω < 0.1 % of end value ≤ 50 ppm/K of measured value at 0 Ω load resistance 100 Hz UE [V] Input Input voltage / Input current Pick-up current Voltage drop Output Output voltage / Output current Load impedance, voltage/current Accuracy Temperature coefficient Cut-off frequency (-3 dB) General data Configuration Ambient temperature Approvals Insulation coordination Standards EMC standards Insulation voltage 9 6 3 0 0 100 200 300 RL [Ω] 400 500 600 none -25 °C...60 °C CE; CSA; cURus; EAC DIN EN 60529, DIN EN 61010-1 EN 61000-6 Tension clamp connection 1.5 / 0.5 / 1.5 63.2 / 6 / Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Ordering data Tension-clamp connection Type MCZ CCC 0-20mA/0-20mA Qty. 10 Order No. 8411190000 Note Accessories Note C.32 Cross-connectors for power supplies and markers: refer to accessories 2028820000 RTD 2-/3-conductor converter Output-loop powered Signal converters in 6 mm width MCZ-SERIES - PT100 / RTD signal converter MCZ PT100/3 CLP / OLP • RTD signal converter for galvanic isolation and conversion of PT100 signals • The component draws power from the output circuit and requires no additional auxiliary power • 2-way isolation • F or 2- or 3-conductor PT100 sensors • O utput current loop feed PT100 J U/I C VC Technical data Input Sensor Sensor supply Output Output current Load impedance, voltage/current General data Configuration Ambient temperature / Storage temperature Accuracy Approvals Standards EMC standards PT100/2-/3-wire (in compliance with IEC 751) 0.8 mA / 9…30 V DC 4…20 mA (current loop) at 9…30V DC / ≤ 600 Ω none / -25 °C...50 °C / -25 °C...85 °C Typical 0.2%, max. 0.5% of FSR CE; CSA; cURus; EAC DIN EN 50178, DIN EN 61000-4-2 EN 61000-6 Tension clamp connection 1.5 / 0.5 / 1.5 63.2 / 6 / Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note Ordering data -40...+100 °C -50...+150 °C 0...100 °C 0...120 °C 0...150 °C 0...200 °C 0...300 °C Note Tension-clamp connection Tension-clamp connection Tension-clamp connection Tension-clamp connection Tension-clamp connection Tension-clamp connection Tension-clamp connection Type MCZ PT100/3 CLP -40C...100C MCZ PT100/3 CLP -50C...+150C MCZ PT100/3 CLP 0...100C MCZ PT100/3 CLP 0...120C MCZ PT100/3 CLP 0...150C MCZ PT100/3 CLP 0...200C MCZ PT100/3 CLP 0...300C Qty. 10 10 10 10 10 10 10 Order No. 8604430000 8473000000 8425720000 8483680000 8604420000 8473010000 8473020000 Accessories Note 2028820000 Cross-connectors for power supplies and markers: refer to accessories C.33 Signal converters in 6 mm width MCZ SERIES - Frequency signal isolator DC/f converter MCZ VFC MCZ CFC The analogue input signal is converted into a configurable frequency signal. Thus analogue signals can be read by the PLC‘s counter inputs. Vcc 4 +24V U/I I C Output 5 3 GND f f f/2f/4f/16 Input f Vcc 5 +24V 1 0...10V OV Output 5 2 U 16kHz 3 GND f f f/2f/4f/16 Input 1 0...20mA OV 2 f I 16kHz Technical data Input Input voltage / Input current Input resistance, voltage/current Voltage drop Output Output frequency Output level Output current Accuracy Temperature coefficient Status indicator General data Configuration Supply voltage Current consumption Current-carrying capacity of cross-connect. Ambient temperature Approvals Insulation coordination Standards EMC standards Rated voltage Impulse withstand voltage Insulation voltage Overvoltage category Pollution degree Clearance & creepage distances Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note 0...10 V / 100 kΩ / / 0...20 mA / 50 Ω 1 V at 20 mA 0...1/ 4/ 8/ 16 kHz PNP, Ub-0.7 V max. 20 mA 0.2% of FSR ≤ 250 ppm/K LED, pulsing 0...1/ 4/ 8/ 16 kHz PNP, Ub-0.7 V max. 20 mA 0.2% of FSR ≤ 250 ppm/K LED, pulsing DIP switch 24 V DC ± 10 % 14 mA without load ≤ 20 A 0 °C...50 °C CE; EAC DIP switch 24 V DC ± 10 % 14 mA without load ≤ 20 A 0 °C...50 °C CE; EAC DIN EN 50178 EN 55011, EN 61000-6 100 V 1.5 kV 1 kV DC III 2 ≥ 1.5 mm DIN EN 50178 EN 55011, EN 61000-6 100 V 1.5 kV 1 kV DC III 2 ≥ 1.5 mm Tension clamp connection 1.5 / 0.5 / 1.5 63.2 / 6 / Tension clamp connection 1.5 / 0.5 / 1.5 63.2 / 6 / Ordering data Tension-clamp connection Type MCZ VFC 0-10V Qty. 10 Order No. 8461470000 Type MCZ CFC 0-20MA Qty. 10 Order No. 8461480000 Note Accessories Note C.34 Cross-connectors for power supplies and markers: refer to accessories Cross-connectors for power supplies and markers: refer to accessories 2028820000 Transistor output MCZ SC 0...10 V Signal converters in 6 mm width MCZ SERIES - Threshold monitoring MCZ SC 0...20 mA • 2 digital outputs • Monitoring of upper and lower limit values • 3 selectable input ranges: 300 mV...10 V, 30 mV...1 V, 10 mV...100 mV 4 U/I Output1 max.50mA 5 VC Output2 max.50mA 3 P1 Th1 P2 Th2 4 2 OV Vcc +24V Output1 max.50mA Input 0-10V 1 5 2 OV 3 Vcc +24V P1 Th1 P2 Th2 Input 0...20mA 1 Output2 max.50mA C Technical data Input Input voltage / Input current Input resistance, voltage/current Voltage drop Output Contact assembly Function Switching thresholds Hysteresis Switching current Step response time Cut-off frequency (-3 dB) Temperature coefficient General data Configuration Supply voltage Ambient temperature Approvals Insulation coordination Standards EMC standards Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note 0...10 V / 60 kΩ / / 0.5...20 mA / 50 Ω 1V double switch output PNP UIN<UTH1: output 1 active / UIN>UTH2: output 2 active Via 2 potentiometers (12 turns) 1% of adjusted final value 50 mA - per channel (voltage drop at transistor: < 1.2 V at 50 mA) < 250 µs (switching threshold at 90% of max. input signal; RI ≤ 1 kΩ) 100 Hz max. 250 ppm/K double switch output PNP IIN<ITH1: Output 1 active / IIN>ITH2: Output 2 active Via 2 potentiometers (12 turns) 1% of adjusted final value 50 mA - per channel (voltage drop at transistor: < 1.2 V at 50 mA) < 250 µs (switching threshold at 90% of max. input signal; RI ≤ 1 kΩ) 100 Hz max. 250 ppm/K Potentiometer 24 V DC ± 20 % 0 °C...50 °C CE; CSA; cURus; EAC Potentiometer 24 V DC ± 20 % 0 °C...50 °C CE; CSA; cURus; EAC DIN EN 50178 EN 55011, EN 61000-6 DIN EN 50178 EN 55011, EN 61000-6 Tension clamp connection 1.5 / 0.5 / 1.5 63.2 / 6 / Tension clamp connection 1.5 / 0.5 / 1.5 63.2 / 6 / Ordering data Tension-clamp connection Type MCZ SC 0-10V Qty. 10 Order No. 8260280000 Type MCZ SC 0-20MA Qty. 10 Order No. 8227350000 Note Accessories Note 2028820000 Cross-connectors for power supplies and markers: refer to accessories Cross-connectors for power supplies and markers: refer to accessories C.35 C C.36 2028820000 Signal converters in 6 mm width