INFINEON TLE6220GP_07

Data Sheet TLE 6220 GP
Smart Quad Low-Side Switch
Features
Product Summary
• Short Circuit Protection
Supply voltage
• Overtemperature Protection
Drain source voltage
• Overvoltage Protection
• 8 bit Serial Data Input and DiagOn resistance
nostic Output (SPI protocol)
Output current (all outp. ON equal)
• Direct Parallel Control of Four
(individually)
Channels for PWM Applications
• Cascadable with Other Quad Switches
• Low Quiescent Current
• µC Compatible Input
• Electostatic Discharge (ESD) Protection
• Green Product (RoHS compliant)
• AEC qualified
Application
• µC Compatible Power Switch for 12 V and 24 V Applications
• Switch for Automotive and Industrial System
• Solenoids, Relays and Resistive Loads
• Injectors
• Robotic controls
VS
VDS(AZ) max
RON
ID(NOM)
4.5 – 5.5
60
0.32
1
3
V
V
Ω
A
A
PG-DSO-20-37
General Description
Quad Low-Side Switch in Smart Power Technology (SPT) with a Serial Peripheral Interface (SPI) and
four open drain DMOS output stages. The TLE 6220 GP is protected by embedded protection functions
and designed for automotive and industrial applications. The output stages can be controlled direct in
parallel for PWM applications (injector coils), or through serial control via the SPI. Therefore the TLE
6220 GP is particularly suitable for engine management and powertrain systems.
Block Diagram
PRG
GND
RESET
FAULT
VS
VS
normal function
IN1
SCB / overload
IN2
as Ch. 1
IN3
as Ch. 1
IN4
as Ch. 1
open load
LOGIC
short to ground
Output Stage
8
SCLK
SI
CS
VBB
1
8
Serial Interface
SPI
OUT1
4
Output Control
Buffer
4
OUT4
SO
GND
V2.1
Page
1
2007-05-03
Data Sheet TLE 6220 GP
Pin Description
Pin Configuration (Top view)
Pin
Symbol
Function
1
2
3
4
5
GND
IN2
OUT1
VS
Ground
Input Channel 2
Power Output Channel 1
Supply Voltage
Reset
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
RESET
CS
PRG
OUT2
IN1
GND
GND
IN4
OUT3
FAULT
SO
SCLK
SI
OUT4
IN3
GND
Chip Select
Program (inputs high or low active)
Power Output Channel 2
Input Channel 1
Ground
Ground
Input Channel 4
Power Output Channel 3
General Fault Flag
GND
IN2
OUT1
VS
RESET
CS
PRG
OUT2
IN1
GND
1•
2
3
4
5
6
7
8
9
10
20 GND
19
IN3
18 OUT4
17
SI
16 SCLK
15
SO
14 FAULT
13 OUT3
12
IN4
11 GND
Power SO-20
Serial Data Output
Serial Clock
Serial Data Input
Power Output Channel 4
Input Channel 3
Ground
Heat slug internally connected to ground pins
V2.1
Page
2
2007-05-03
Data Sheet TLE 6220 GP
Maximum Ratings for Tj = – 40°C to 150°C
Parameter
Supply Voltage
Continuous Drain Source Voltage (OUT1...OUT4)
Input Voltage, All Inputs and Data Lines
Load Dump Protection VLoad Dump = UP+US; UP=13.5 V
With Automotive Injector Valve RL = 14 Ω
RI1)=2 Ω ; td=400ms; IN = low or high
With RL= 6.8 Ω (ID = 2A)
RI=2 Ω ; td=400ms; IN = low or high
Operating Temperature Range
Storage Temperature Range
Output Current per Channel (see el. characteristics)
Output Current per Channel @ TA = 25°C
(All 4 Channels ON; Mounted on PCB )3)
Output Clamping Energy
ID = 1A
Power Dissipation (DC, mounted on PCB) @ TA = 25°C
Electrostatic Discharge Voltage (human body model)
according to MIL STD 883D, method 3015.7 and EOS/ESD
assn. standard S5.1 - 1993
DIN Humidity Category, DIN 40 040
IEC Climatic Category, DIN IEC 68-1
Thermal resistance
junction – case (die soldered on the frame)
junction - ambient @ min. footprint
junction - ambient @ 6 cm2 cooling area
Minimum footprint
Symbol
VS
VDS
VIN
VLoad
Dump
2)
Values
-0.3 ... +7
45
- 0.3 ... + 7
Unit
V
V
V
V
62
52
Tj
Tstg
ID(lim)
ID
- 40 ... + 150
- 55 ... + 150
ID(lim) min
1
EAS
50
Ptot
VESD
3
2000
°C
A
A
mJ
W
V
E
40/150/56
K/W
RthJC
RthJA
2
50
38
PCB with heat pipes,
backside 6 cm2 cooling area
1)
RI=internal resistance of the load dump test pulse generator LD200
VLoadDump is setup without DUT connected to the generator per ISO 7637-1 and DIN 40 839.
3)
Output current rating so long as maximum junction temperature is not exceeded. At TA = 125 °C the output
current has to be calculated using RthJA according mounting conditions.
2)
V2.1
Page
3
2007-05-03
Data Sheet TLE 6220 GP
Electrical Characteristics
Parameter and Conditions
VS = 4.5 to 5.5 V ; Tj = - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
Symbol
Values
min
Unit
typ
max
1. Power Supply, Reset
Supply Voltage4
Supply Current
5
VS
4.5
IS
--
Minimum Reset Duration
tReset,min
(After a reset all parallel inputs are ORed with the SPI data
bits)
2. Power Outputs
ON Resistance VS = 5 V; ID = 1 A
Output Clamping Voltage
Output Leakage Current
1
2
V
mA
10
µs
Ω
--
45
53
60
V
ID(lim)
3
4.5
6
A
ID(lkg)
--
--
10
µA
RDS(ON)
output OFF
VRESET = L
5.5
0.4
0.7
TJ = 25°C
TJ = 150°C
Current Limit
--
--
0.32
-VDS(AZ)
Turn-On Time
ID = 1 A, resistive load
tON
--
5
10
µs
Turn-Off Time
ID = 1 A, resistive load
tOFF
--
5
10
µs
3. Digital Inputs
Input Low Voltage
VINL
- 0.3
--
1.0
V
Input High Voltage
VINH
2.0
--
VS+0.
3
V
Input Voltage Hysteresis
VINHys
50
100
200
mV
Input Pull Down/Up Current (IN1 ... IN4)
PRG, RESET Pull Up Current
Input Pull Down Current (SI, SCLK)
Input Pull Up Current (CS )
IIN(1..4)
IIN(PRG,Res)
IIN(SI,SCLK)
IIN(CS)
20
20
10
10
50
50
20
20
100
100
50
50
µA
µA
µA
µA
4. Digital Outputs (SO, FAULT )
SO High State Output Voltage
SO Low State Output Voltage
Output Tri-state Leakage Current
FAULT Output Low Voltage
VSOH
VSOL
ISOlkg
VFAULTL
ISOH = 2 mA
ISOL = 2.5 mA
CS = H, 0 ≤ VSO ≤ VS
IFAULT = 1.6 mA
Current Limitation; Overload Threshold Current
Overtemperature Shutdown Threshold
Hysteresis6
ID(lim) 1...4
Tth(sd)
Thys
VS - 0.4 ----10
0
--
--
-0.4
10
0.4
3
170
--
4.5
-10
6
200
--
V
V
µA
V
A
°C
K
4
For VS < 4.5V the power stages are switched according the input signals and data bits or are definitely
switched off. This undervoltage reset gets active at VS = 3V (typ. value) and is guaranteed by design.
5
If Reset = L the supply current is reduced to typ. 20µA
6
This parameter will not be tested but guaranteed by design
V2.1
Page
4
2007-05-03
Data Sheet TLE 6220 GP
Electrical Characteristics cont.
Parameter and Conditions
VS = 4.5 to 5.5 V ; Tj = - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
Symbol
5. Diagnostic Functions
Open Load Detection Voltage
Output Pull Down Current
Fault Delay Time
Short to Ground Detection Voltage
Short to Ground Detection Current
VDS(OL)
IPD(OL)
td(fault)
VDS(SHG)
ISHG
6. SPI-Timing
Serial Clock Frequency (depending on SO load)
Serial Clock Period (1/fclk)
Serial Clock High Time
Serial Clock Low Time
Enable Lead Time (falling edge of CS to rising edge of CLK)
Enable Lag Time (falling edge of CLK to rising edge ofCS )
Data Setup Time (required time SI to falling of CLK)
Data Hold Time (falling edge of CLK to SI)
Disable Time @ CL = 50 pF8
Transfer Delay Time7
( CS high time between two accesses)
Data Valid Time
CL = 50 pF
CL = 100 pF8
CL = 220 pF8
fSCK
tp(SCK)
tSCKH
tSCKL
tlead
tlag
tSU
tH
tDIS
tdt
tvalid
Values
min
Unit
typ
max
VS -2.5
50
50
VS –3.3
-50
VS -2
90
110
VS -2.9
-100
VS -1.3
150
200
VS -2.5
-150
V
µA
µs
V
µA
DC
200
50
50
250
250
20
20
-200
------------
5
-------150
--
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
----
----
110
120
150
ns
7
This time is necessary between two write accesses. To get the correct diagnostic information, the transfer
delay time has to be extended to the maximum fault delay time td(fault)max = 200µs.
8
This parameter will not be tested but guaranteed by design
V2.1
Page
5
2007-05-03
Data Sheet TLE 6220 GP
Functional Description
The TLE 6220 GP is an quad-low-side power switch which provides a serial peripheral interface
(SPI) to control the 4 power DMOS switches, as well as diagnostic feedback. The power transistors are protected against short to VBB, overload, overtemperature and against overvoltage by
an active zener clamp.
The diagnostic logic recognises a fault condition which can be read out via the serial diagnostic
output (SO).
Circuit Description
9)
Power Transistor Protection Functions
Each of the four output stages has its own zener clamp, which causes a voltage limitation at the
power transistor when solenoid loads are switched off. The outputs are provided with a current
limitation set to a minimum of 3 A. The continuous current for each channel is 1A (all channels
ON; depending on cooling).
Each output is protected by embedded protection functions. In the event of an overload or
short to supply, the current is internally limited and the corresponding bit combination is set
(early warning). If this operation leads to an overtemperature condition, a second protection
level (about 170 °C) will change the output into a low duty cycle PWM (selective thermal shutdown with restart) to prevent critical chip temperatures.
SPI Signal Description
CS - Chip Select. The system microcontroller selects the TLE 6220 GP by means of the CS
pin. Whenever the pin is in a logic low state, data can be transferred from the µC and vice
versa.
CS High to Low transition: - Diagnostic status information is transferred from the power
outputs into the shift register.
- Serial input data can be clocked in from then on.
- SO changes from high impedance state to logic high or low
state corresponding to the SO bits.
CS Low to High transition: - Transfer of SI bits from shift register into output buffers
- Reset of diagnosis register.
To avoid any false clocking the serial clock input pin SCLK should be logic low state during high
to low transition of CS . When CS is in a logic high state, any signals at the SCLK and SI pins
are ignored and SO is forced into a high impedance state.
9)
The integrated protection functions prevent an IC destruction under fault conditions and may not be used in normal operation
or permanently.
V2.1
Page
6
2007-05-03
Data Sheet TLE 6220 GP
SCLK - Serial Clock. The system clock pin clocks the internal shift register of the TLE 6220 GP.
The serial input (SI) accepts data into the input shift register on the falling edge of SCLK while
the serial output (SO) shifts diagnostic information out of the shift register on the rising edge of
serial clock. It is essential that the SCLK pin is in a logic low state whenever chip select CS
makes any transition.
SI - Serial Input. Serial data bits are shifted in at this pin, the most significant bit first. SI information is read in on the falling edge of SCLK. Input data is latched in the shift register and then
transferred to the control buffer of the output stages.
The input data consists of one byte, made up of four control bits and four data bits. The control
word is used to program the device, to operate it in a certain mode as well as providing diagnostic information (see page 11). The four data bits contain the input information for the four
channels, and are high active.
SO - Serial Output. Diagnostic data bits are shifted out serially at this pin, the most significant
bit first. SO is in a high impedance state until the CS pin goes to a logic low state. New diagnostic data will appear at the SO pin following the rising edge of SCLK.
RESET - Reset pin. If the reset pin is in a logic low state, it clears the SPI shift register and
switches all outputs OFF. An internal pull-up structure is provided on chip. As long as the reset
pin is low the device is in low quiescent current mode and the supply current is reduced to typ.
20µA.
Output Stage Control
The four outputs of the TLE 6220 GP can either be controlled in parallel (IN1...IN4), or via the
Serial Peripheral Interface (SPI).
Parallel Control
A Boolean operation (either AND or OR) is performed on each of the parallel inputs and respective SPI data bits, in order to determine the states of the respective outputs. The type of
Boolean operation performed is programmed via the serial interface.
The parallel inputs are high or low active depending on the PRG pin. If the parallel input pins
are not connected (independent of high or low activity) it is guaranteed that the outputs 1 to 4
are switched OFF. PRG pin itself is internally pulled up when it is not connected.
PRG - Program pin.
V2.1
PRG = High (VS): Parallel inputs Channel 1 to 4 are high active
PRG = Low (GND): Parallel inputs Channel 1 to 4 are low active.
Page
7
2007-05-03
Data Sheet TLE 6220 GP
Serial Control of the Outputs: SPI protocol
Each output is independently controlled by an output latch and a common reset line, which disables all four outputs. The Serial Input (SI) is read on the falling edge of the serial clock. A logic
high input 'data bit' turns the respective output channel ON, a logic low 'data bit' turns it OFF.
CS must be low whilst shifting all the serial data into the device. A low-to-high transition of CS
transfers the serial data input bits to the output control buffer.
As mentioned above, the serial input byte consists of a 4 bit control word and a 4 bit data word.
Via the control word, the specific mode of the device is programmable.
MSB
LSB
CCCC
123 DDDD
123 : Serial input byte
Control Bits Data Bits
Five specific control words are recognised, having the following functions:
No.
1
2
3
4
5
Serial Input Byte
LLLL XXXX
HHLL XXXX
HLHL XXXX
LLHH DDDD
HHHH DDDD
Function
Only 'Full Diagnosis' performed. No change to output states.
State of four parallel inputs and '1-bit Diagnosis' outputted.
Echo-function of SPI; SI direct connected to SO
IN1...4 and serial data bits 'OR'ed. 'Full Diagnosis' performed.
IN1...4 and serial data bits 'AND'ed. 'Full Diagnosis' performed.
Note: 'X' means 'don't care', because this bit will be ignored
'D' represents the data bit, either being H (=ON) or L (=OFF)
1. LLLL XXXX - Diagnosis only
By clocking in this control byte, it is possible to get pure diagnostic information (two bits per
channel) in accordance with Figure 1 (page 11). The data bits are ignored, so that the state of
the outputs are not influenced. This command is only active once unless the next control command is again "Diagnosis only".
2. HHLL XXXX - Reading back of input, and ‘1-bit Diagnosis’
If the TLE 6220 GP is used as bare die in a hybrid application, it is necessary to know if proper
connections exist between the µC-port and parallel inputs. By entering ‘HHLL’ as the control
word, the first four bits of the SO give the state of the parallel inputs, depending on the µC signals. By comparing the four IN-bits with the corresponding µC-port signal, the necessary connection between the µC and the TLE 6220 can be verified - i.e. ‘read back of the inputs’.
The second 4-bit word fed out at the serial output contains ‘1-bit’ fault information of the outputs ( H = no fault, L = fault ). In the expression given below for the output byte, ‘FX’ is the fault
bit for channel X.
MSB
LSB
IN4 IN3 IN2 IN1 F4 F3 F2 F1
V2.1
Page
8
: Serial Output byte
2007-05-03
Data Sheet TLE 6220 GP
CS
SI
CS
H H L L X X X X
CS
SI
H H H H L H H L
SI
SO H H H H H H H H
SO
IN4 IN3 IN2 IN1 F4 F3 F2 F1
H H H H L L L L
SO H H H H H H H H
SI command: No change of the
output state; reading back of
inputs and 1bit diagnosis
SO diagnosis : No fault, normal
function
SI command : AND-Operation;
Ch1 and 4 OFF, Ch2 and 3 ON.
SO diagnosis: State of four parallel
inputs and 1 bit diagnosis performed
SI command: AND-Operation and
all channels OFF.
SO diagnosis: No fault, normal
function
3. HLHL XXXX
- Echo-function of SPI
To check the proper function of the serial interface the TLE 6220 GP provides a "SPI Echo
Function". By entering HLHL as control word, SI and SO are connected during the next CS period. By comparing the bits clocked in with the serial output bits, the proper function of the SPI
interface can be verified. This internal loop is only closed once (for one CS period).
CS
SI
CS
H L H L X X X X
SI word
SI
SO
SO H H H H L H H H
SI command: No change of the
output states; Echo function of SPI
SO diagnosis : Open load condition
at channel 2, other channels ok.
Echo-function of SPI, i.e. SI
directly connected to SO.
SI information will be accepted
during this cycle and the
outputs set accordingly after
chip select rising edge
4. LLHH DDDD - OR operation, and ‘full diagnosis’
With LLHH as the control word, each of the input signals IN1...IN4 are 'OR'ed with the corresponding data bits (DDDD).
IN 1...4
≥1
Output
Driver
Serial Input,
data bits 0...3
This OR operation enables the serial interface to switch the channel ON, even though the corresponding parallel input might be in the off state.
⇒ SPI Priority for ON-State
Also parallel control of the outputs is possible without an SPI input.
The OR-function is the default Boolean operation if the device restarts after a Reset, or when
the supply voltage is switched on for the first time.
V2.1
Page
9
2007-05-03
Data Sheet TLE 6220 GP
If the OR operation is programmed it is latched until it is overwritten by the AND operation.
5. HHHH DDDD - AND operation, and ‘full diagnosis’
With HHHH as the control word, each of the input signals IN1...IN4 are 'AND'ed with the corresponding data bits (DDDD).
IN 1...4
&
Output
Driver
Serial Input,
data bits 0...3
The AND operation implies that the output can be switched off by the SPI data bit input, even if
the corresponding parallel input is in the ON state.
⇒ SPI Priority for OFF-state
This also implies that the serial input data bit can only switch the output channel ON if the corresponding parallel input is in the ON state.
If the AND operation is programmed it is latched until it is overwritten by the OR operation.
Control words beside No. 1- 5
All control words except those for Diag Only, Read Back of Inputs, SPI echo, will be accepted as
an OR or an AND command with valid data bits depending on the boolean operation which was
programmed before.
Example 1:
LLHH HLLH: OR operation between parallel inputs and data bits, i.e channel 1 and 4 will be
switched on.
The next command is now: LHHH HHLH
LHHH as command word has no special meaning but it will be accepted as an OR operation and
the data bits will be ORed with the inputs and the outputs 1,3 and 4 will be switched on.
See above: 'If the OR operation is programmed it is latched until it is overwritten by the AND
operation.'
Example 2:
HHHH LLHL means: Data bits will be ANDed with the parallel inputs and the outputs switch accordingly. Then HLLH HHLH is clocked in: AND was latched by the command before and is now
valid again by using the HLLH command word. So the data bits will be accepted and again
ANDed with the parallel input signals.
See above: 'If the AND operation is programmed it is latched until it is overwritten by the OR
operation.'
V2.1
Page
10
2007-05-03
Data Sheet TLE 6220 GP
Diagnostics
FAULT - Fault pin. There is a general fault pin (open drain) which shows a high to low transition as soon as an error occurs for any one of the four channels. This fault indication can be
used to generate a µC interrupt. Therefore a ‘diagnosis’ interrupt routine need only be called
after this fault indication. This saves processor time compared to a cyclic reading of the SO information.
As soon as a fault occurs, the fault information is latched into the diagnosis register. A new error will over-write the old error report. Serial data out pin (SO) is in a high impedance state
when CS is high. If CS receives a LOW signal, all diagnosis bits can be shifted out serially.
The rising edge of CS will reset all error registers.
Full Diagnosis
For full diagnosis there are two diagnostic bits per channel configured as shown in Figure 1.
Diagnostic Serial OUT (SO)
7
6
Ch.4
HH
HL
LH
LL
5
4
Ch.3
3
2
Ch.2
1
0
Ch.1
Normal function
Overload, Shorted Load or Overtemperature
Open Load
Shorted to Ground
Figure 1: Two bits per channel diagnostic feedback
Normal function: The bit combination HH indicates that there is no fault condition, i.e. normal
function.
Overload, Short Circuit to Battery (SCB) or Overtemperature: HL is set when the current
limitation gets active, i.e. there is a overload, short to supply or overtemperature condition.
Open load: An open load condition is detected when the drain voltage decreases below 3 V
(typ.). LH bit combination is set.
Short Circuit to GND: If a drain to ground short circuit exists and the drain to ground current
exceeds 100 µA, short to ground is detected and the LL bit combination is set.
A definite distinction between open load and short to ground is guaranteed by design.
The standard way of obtaining diagnostic information is as follows:
Clock in serial information into SI pin and wait approximately 150 µs to allow the outputs to settle. Clock in the identical serial information once again - during this process the data coming out
at SO contains the bit combinations representing the diagnosis conditions as described in Figure 1.
V2.1
Page
11
2007-05-03
Data Sheet TLE 6220 GP
Timing Diagrams
CS
SCLK
Control
Bits
Data
64444
74444
8 64444
7Bits
44448
SI
7
6
5
4
3
2
1
LSB
MSB
SO
0
7
6
5
4
Outputs
3
2
OLD
1
0
NEW
Figure 2: Serial Interface
Figure 3: Input Timing Diagram
CS
0.7VS
tdt
0.2 VS
tlag
tSCKH
tlead
0.7VS
SCLK
0.2VS
tSCKL
tSU
tH
0.7VS
SI
0.2V S
Figure 4:
0.7 V S
SCLK
CS
0.2 V S
t valid
tD i s
SO
0.7 V S
0.2 V S
SO
SO
0.7 V S
0.2 V S
SO Valid Time Waveforms
V2.1
Enable and Disable Time Waveforms
Page
12
2007-05-03
Data Sheet TLE 6220 GP
VIN
t
tOFF
tON
VDS
80%
20%
t
Figure 5: Power Outputs
Application Circuit
VBB
VS
10k
VS
PRG
OUT1
FAULT
OUT2
RESET
IN1
IN2
IN3
IN4
µC
e.g. C166
MTSR
SI
MRST
SO
CLK
OUT4
TLE
6220
GP
CLK
P xy
GND
V2.1
Page
13
2007-05-03
Data Sheet TLE 6220 GP
Typical electrical Characteristics
Drain-Source on-resistance
RDS(ON) = f (Tj) ; Vs = 5V
Channel 1-4
Typical Drain- Source ON-Resistance
0,58
0,53
RDS(ON) [Ohm]
0,48
0,43
0,38
0,33
0,28
0,23
-50
-25
0
25
50
75
100
125
150
175
Tj[°C]
Figure 6 :
Typical ON Resistance versus Junction-Temperature
Channel 1-4
Output Clamping Voltage
VDS(AZ) = f (Tj) ; Vs = 5V
Channel 1-4
Typical Clamping Voltage
55
54
VDS (AZ) [V]
53
52
51
50
49
48
-50
-25
0
25
50
75
100
125
150
175
Tj[°C]
Figure 7 :
V2.1
Typical Clamp Voltage versus Junction-Temperature
Channel 1-4
Page
14
2007-05-03
Data Sheet TLE 6220 GP
Parallel SPI Configuration
Engine Management Application
TLE 6230 GP in combination with TLE 6240 GP (16-fold switch) for relays and general purpose loads
and TLE 6220 GP (quad switch) to drive the injector valves. This arrangement covers the numerous
loads to be driven in a modern Engine Management/Powertrain system. From 28 channels in sum 16
can be controlled direct in parallel for PWM applications.
Injector 1
4
P x.1-4
4 PWM
Channels
MTSR
MRST
SI
SO
CLK
P x.y
CS
CS
Injector 3
TLE
6220 GP
Quad
CLK
4
Injector 2
Injector 4
4 PWM
Channels
P x.1-4
µC
SI
SO
C167
CLK
CS
P x.y
TLE
6230 GP
Octal
8
8 PWM
Channels
P x.1-8
SI
SO
CLK
CS
P x.y
TLE
6240 GP
16-fold
Daisy Chain Application TLE 6220 GP
Px.1
Px.2
CS
CLK
CS
CLK
CS
CLK
µC
TLE
SO
6220
GP
CS
Quad
SI
MTSR
SI
TLE
SO
6220 GP
Quad
SI
TLE
SO
6220 GP
Quad
MRST
V2.1
Page
15
2007-05-03
Data Sheet TLE 6220 GP
Package and Ordering Code
(all dimensions in mm)
PG - DSO - 20 - 37
Ordering Code
TLE 6220 GP
Q67006-A9315
15 .7 4
13.7
+ /- 0 .1
-0.2
9 x 1 .2 7 = 1 1.43
1.27
+0 .1 3
1.2
-0.3
0.25 M
A
1
5 .9 + /-0 .1
11
3.2 +/- 0 .1
20
0.4
10
1 x 45°
P IN 1 IN D EX M AR K IN G
A
1 5.9 +/- 0 .1 5
1 .3
0 .1
8°
2.8
8°
8°
8°
6.3
1)
1 1 +/- 0.15
14 .2 +/- 0 .3
V2.1
Page
16
2007-05-03
Data Sheet TLE 6220 GP
Green Product (RoHS compliant)
To meet the world-wide customer requirements for environmentally friendly products and to be compliant
with government regulations the device is available as a green product. Green products are RoHSCompliant (i.e Pb-free finish on leads and suitable for Pb-free soldering according to IPC/JEDEC J-STD020).
V2.1
Page
17
2007-05-03
Data Sheet TLE 6220 GP
Revision History
Version
V2.0 ->
V2.1
Date
20.05.03
Changes
Ordering Code removed
V1.1 ->
V2.0
V2.0
20.04.2007
Green Date sheet Version created
20.04.2007
V2.0 ->
V2.1
05.04.2007
Changes to Green Product Version:
- AEC, RoHS Logo and Feature List content added
- Package Name P-DSO -> PGDSO
- Change History added
- Disclaimer re-newed
Layout Changes, correct green package name implemented P-DSO-3612 à PG-DSO-36-26
V1.1
28.Aug.2007
V2.1
Initial Version of “grey” product
Page
18
2007-05-03
Data Sheet TLE 6220 GP
Edition 2007-04-17
Published by
Infineon Technologies AG
81726 Munich, Germany
© 5/4/07 Infineon Technologies AG
All Rights Reserved.
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties
and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property
rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices, please contact the nearest
Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements, components may contain dangerous substances. For information on the types
in question, please contact the nearest Infineon Technologies Office.
Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause
the failure of that life-support device or system or to affect the safety or effectiveness of that device or system.
Life support devices or systems are intended to be implanted in the human body or to support and/or maintain
and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other
persons may be endangered.
V2.1
Page
19
2007-05-03