VECTRON TFS140M

File name: Tfs140M.doc
version 1.3
VI TELEFILTER
1.
Filter specification
28.06.2002
TFS 140 M
1/5
Measurement condition :
45
°C
0
dBm
for input:
for output:
Ambient temperature TA:
Input power level:
Terminating impedances in fc :
2.
50
50
0 pF.
0 pF.
Characteristics :
Remark: Reference level for the relative attenuation arel of the TFS 140 M is the minimum of the pass band attenuation a min. The minimum of
the pass band attenuation amin is defined as the insertion loss a e. The centre frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 6 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tcf is valid both for the
reference frequency fc and the frequency response of the filter in the operating temperature range.
Data
typ. value
Insertion loss :
(Reference level)
Centre frequency at ambient temperature :
28,5 dB
fc
140,00 MHz
140,00 ± 0,25 MHz
140,23 MHz
140,23 ± 0,25 MHz
Centre frequency at room temperature T=23°C:
1)
Pass band : ( see theoretical frequency response)
Pass band tilt :
Deviation from theoretical frequency response 1) (p-p) :
fC .... fC ± fY
Deviation from theoretical phase response
fC .... fC ± fY
2)
0,0 dB
max.
0,01 dB/MHz
± 0,15 dB
± max. 0,4
dB
±1°
± max. 2
degree
dB
min.
40
dB
1,467 µs
60
dB
60
dB
min.
min.
45
45
dB
dB
50
C
fY
a
p
p5 = 0,6524
p11 = - 0,110
Input power level
-
Temperature coefficient of frequency :
Frequency deviation of f c over temperature :
Operating temperature range ( OgTR ) :
Operable temperature range ( OTR ) :
Storage temperature range ( STR ) :
Tcf
13,805 MHz
0,25
0,5
p7 = - 0,6715
p13 = 0,01421
p15 = - 0,0006794
max.
15
dBm
- 75
ppm / K
fc(Hz) = Tcf(ppm/K) x (T - TA) x fC (MHz)
+ 45 °C
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
H (x)
( S ( x ))
p
;
1
S (x)
1
2
where
f
x
,
1
cos
2
fC
fY
for
(x
1
a)
2a
, for
for
0
2)
dB
arel
p3 = 0,009987
p9 = 0,3920
Theoretical frequency response :
30,5
(p-p):
Group delay at fc :
Reflected attenuation compared to main signal
Crosstalk attenuation compared to main signal
1)
max.
PB
Relative attenuation at ambient temperature :
fC ± 18
MHz .... fC ± 100
MHz
Nyquist frequency
Roll-off factor
Partitioning factor
Phase coefficients :
tolerance / limit
ae
x
(1
(1
a)
a)
(1
x
a)
(1
a ),
f
fC
x
Theoretical phase response :
Ph ( y )
[ p3 y 3
p5 y 5
p7 y 7
p9 y 9
p 11 y 11
p 13 y 13
Generated:
W. Dunzow
Checked / approved:
Dr. Bert Wall
p 15 y 15 ](
180
) [deg]
where
y
10
[ MHz ]
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs140M.doc
version 1.3
VI TELEFILTER
Filter specification
TFS
1
Date-code:
M
N
P
...
140 M
P55
25,0 Max.
0,50Max.
6 7 8
16 15 14
11 10 9
2/5
pin grid 2,54 mm
Year+week
2000
2001
2002
...
Pin 3
Pin 2
Pin 11
Pin 10
Pin 1, 8, 9, 16
Pin 6, 7, 14, 15
7,62
1 2 3
28.06.2002
Date-code
5,0 Max. 6,7 Max.
13,0 Max.
3. Construction and pin connection : (All dimensions in mm)
TFS 140 M
input
input RF Return
output
output RF Return
package ground
not connected
7X2,54=17,78
4. 50
- Matching network :
8
9
7
10
6
11
50
50
3
14
2
15
1
16
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs140M.doc
version 1.3
VI TELEFILTER
Filter specification
28.06.2002
TFS 140 M
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow): reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs140M.doc
version 1.3
VI TELEFILTER
Filter specification
28.06.2002
TFS 140 M
4/5
6. Soldering temperature conditions :
1st and 2nd soldering temperature profile
Name:
Temperature:
Time:
pre-heating periods main-heating periods
150 °C - 170 °C
over 200 °C
60 sec. - 90 sec.
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Soldering temperature profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the soldering process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs140M.doc
VI TELEFILTER
version 1.3
Filter specification
28.06.2002
TFS 140 M
5/5
7. History :
Version
Reason of Changes
Name
Date
1.0
Generation of development specification according to customer requirements.
Dunzow W.
06.11.2001
1.1
Correct theoretical phase response according to customer requirements.
Dunzow W.
13.11.2001
1.2
Generate filter specification.
Add typical measured values.
Dunzow W.
28.05.2002
1.3
Package drawing correction.
Dunzow W.
28.06.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.