File name: Tfs140M.doc version 1.3 VI TELEFILTER 1. Filter specification 28.06.2002 TFS 140 M 1/5 Measurement condition : 45 °C 0 dBm for input: for output: Ambient temperature TA: Input power level: Terminating impedances in fc : 2. 50 50 0 pF. 0 pF. Characteristics : Remark: Reference level for the relative attenuation arel of the TFS 140 M is the minimum of the pass band attenuation a min. The minimum of the pass band attenuation amin is defined as the insertion loss a e. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 6 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value Insertion loss : (Reference level) Centre frequency at ambient temperature : 28,5 dB fc 140,00 MHz 140,00 ± 0,25 MHz 140,23 MHz 140,23 ± 0,25 MHz Centre frequency at room temperature T=23°C: 1) Pass band : ( see theoretical frequency response) Pass band tilt : Deviation from theoretical frequency response 1) (p-p) : fC .... fC ± fY Deviation from theoretical phase response fC .... fC ± fY 2) 0,0 dB max. 0,01 dB/MHz ± 0,15 dB ± max. 0,4 dB ±1° ± max. 2 degree dB min. 40 dB 1,467 µs 60 dB 60 dB min. min. 45 45 dB dB 50 C fY a p p5 = 0,6524 p11 = - 0,110 Input power level - Temperature coefficient of frequency : Frequency deviation of f c over temperature : Operating temperature range ( OgTR ) : Operable temperature range ( OTR ) : Storage temperature range ( STR ) : Tcf 13,805 MHz 0,25 0,5 p7 = - 0,6715 p13 = 0,01421 p15 = - 0,0006794 max. 15 dBm - 75 ppm / K fc(Hz) = Tcf(ppm/K) x (T - TA) x fC (MHz) + 45 °C - 40 °C ... + 85 °C - 40 °C ... + 85 °C H (x) ( S ( x )) p ; 1 S (x) 1 2 where f x , 1 cos 2 fC fY for (x 1 a) 2a , for for 0 2) dB arel p3 = 0,009987 p9 = 0,3920 Theoretical frequency response : 30,5 (p-p): Group delay at fc : Reflected attenuation compared to main signal Crosstalk attenuation compared to main signal 1) max. PB Relative attenuation at ambient temperature : fC ± 18 MHz .... fC ± 100 MHz Nyquist frequency Roll-off factor Partitioning factor Phase coefficients : tolerance / limit ae x (1 (1 a) a) (1 x a) (1 a ), f fC x Theoretical phase response : Ph ( y ) [ p3 y 3 p5 y 5 p7 y 7 p9 y 9 p 11 y 11 p 13 y 13 Generated: W. Dunzow Checked / approved: Dr. Bert Wall p 15 y 15 ]( 180 ) [deg] where y 10 [ MHz ] VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: Tfs140M.doc version 1.3 VI TELEFILTER Filter specification TFS 1 Date-code: M N P ... 140 M P55 25,0 Max. 0,50Max. 6 7 8 16 15 14 11 10 9 2/5 pin grid 2,54 mm Year+week 2000 2001 2002 ... Pin 3 Pin 2 Pin 11 Pin 10 Pin 1, 8, 9, 16 Pin 6, 7, 14, 15 7,62 1 2 3 28.06.2002 Date-code 5,0 Max. 6,7 Max. 13,0 Max. 3. Construction and pin connection : (All dimensions in mm) TFS 140 M input input RF Return output output RF Return package ground not connected 7X2,54=17,78 4. 50 - Matching network : 8 9 7 10 6 11 50 50 3 14 2 15 1 16 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: Tfs140M.doc version 1.3 VI TELEFILTER Filter specification 28.06.2002 TFS 140 M 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: Tfs140M.doc version 1.3 VI TELEFILTER Filter specification 28.06.2002 TFS 140 M 4/5 6. Soldering temperature conditions : 1st and 2nd soldering temperature profile Name: Temperature: Time: pre-heating periods main-heating periods 150 °C - 170 °C over 200 °C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Soldering temperature profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the soldering process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: Tfs140M.doc VI TELEFILTER version 1.3 Filter specification 28.06.2002 TFS 140 M 5/5 7. History : Version Reason of Changes Name Date 1.0 Generation of development specification according to customer requirements. Dunzow W. 06.11.2001 1.1 Correct theoretical phase response according to customer requirements. Dunzow W. 13.11.2001 1.2 Generate filter specification. Add typical measured values. Dunzow W. 28.05.2002 1.3 Package drawing correction. Dunzow W. 28.06.2002 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.