VECTRON TFS70H13A

Filename: tfs 70h13a.doc
Version 1.1
VI TELEFILTER
Filter specification
0
Measurement
condition
-10
Ambient temperature:
Input-20power level:
Terminating
impedance:
-30
Input:
B
-40
Output:
d
25
0
°C
dBm
50 Ω || 0 pF
50 Ω || 0 pF
ni
-50
e
d
ut
i
-60
n
g
Characteristics
a
m
-70
B
d
ni
e
d
ut
i
n
g
a
m
Remark:
26.08.2004
TFS 70H13A
1/5
0
2.215
-1
2.17
-2
2.125
-3
2.08
-4
2.035
s
µ
1.99 ni
y
a
1.945el
d
-5
-6
1.9
-7
-8
-80
The reference
level for the relative attenuation arel of the TFS 70H13A is the minimum
of the pass band attenuation amin. The minimum of the1.855
pass band
attenuation
amin is defined as the insertion loss ae. The centre frequency fc is the -9
arithmetic mean value of the upper and lower frequencies at1.81
the 40 dB
-90
filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the
frequency
response of the filter in the operating temperature range. The frequency-10
shift of the filter in the operating temperature range is not included
1.765 in the
-100
66
67
68
69
70
71
72
73
74
75
58
60.4 62.8 65.2 67.6
70
72.4 74.8 77.2 79.6
82
65
production tolerance scheme. frequency in MHz
frequency in MHz
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae
22,7
dB
Centre frequency
fC
70,0
MHz
max.
fC ± 4,0 MHz
BW
Bandwidth
1
dB
3
dB
40
dB
Relative attenuation
±
±
dB
70,0 ± 0,1 MHz
Passband
fC
fC
fC
24
3,6
3,8
5,3
fC ±
6,0
fC ±
15,0
fC ±
Group delay
7,83
8,39
10,62
… fC
MHz … fC
MHz … fC
±
±
±
3,6
3,8
4,0
MHz … fC
MHz … fC
MHz … fC
±
±
±
6,0
15,0
50,0
arel
MHz
MHz
MHz
MHz
MHz
MHz
mean value in PB
Group delay ripple within PB
MHz
MHz
MHz
min.
min.
max.
7,6
8,0
10,6
0,45
0,6
1,5
dB
dB
dB
max.
max.
max.
0,8
1
3
dB
dB
dB
45
50
60
1,83
dB
dB
dB
µs
min.
min.
min
max.
min.
40
45
50
2,5
1,5
dB
dB
dB
µs
µs
40
ns
max.
60
ns
°
max.
4
2,4
Deviation from linear phase within PB
Triple transit response suppression
54
dB
-
Crosstalk attenuation compared to main signal
60
dB
-
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf *
-
- 40 °C ... + 85°C
-
- 55 °C ... + 85°C
- 87
ppm/K
MHz
MHz
MHz
°
-
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
Generated:
Checked / Approved:
Filter characteristic
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70h13a.doc
Version 1.1
26.08.2004
VI TELEFILTER
Filter specification
TFS 70H13A
2/5
Construction and pin connection
(All dimensions in mm)
TFS 70H13A
246-800123-001
●
S35
13 Max.
22,5 Max.
Date code
1
2
7
8
9
14
Input RF Return
Ground
Output RF Return
Output
Ground
Input
Date code:
S
T
U
...
Year + week
2004
2005
2006
7
1
6 Max.
4,5 Min.
7,62+/-0,2
5 Max.
1Dia.0,45+/-0,05
10,16+/-0,2
14 15,24+/-0,2 8
50 Ohm Test circuit
14
8
L1
L2
1, 2, 7, 9
Stability characteristics :
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70h13a.doc
Version 1.1
VI TELEFILTER
Filter specification
26.08.2004
TFS 70H13A
3/5
After the following tests the filter shall meet the whole specification:
1. Shock:
30g, 11 ms, sawtooth, 3 shocks each plane;
MIL-STD-202, Method 213 test condition K
2. Vibration:
10 Hz to 2000 Hz, 15g, 20min per cycle, 12 cycles per plan, 3 plans;
MIL-STD 202, Method 204, test condition B
3. Thermal
shock
-40°C to 85°C, 5 cycles
MIL-STD 202, Method 107, test condition A
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70h13a.doc
Version 1.1
26.08.2004
VI TELEFILTER
Filter specification
TFS 70H13A
4/5
Air reflow temperature conditions :
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70h13a.doc
Version 1.1
VI TELEFILTER
Filter specification
26.08.2004
TFS 70H13A
5/5
History
Version
Reason of changes
Name
Date
1.0
filter specification created
Pfeiffer
17.06.2004
1.1
operating and storage temperature range extended
Pfeiffer
26.08.2004
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.