Filename: tfs 70h29a.doc Version 1.1 28.06.2004 VI TELEFILTER Filter specification TFS 70H29A 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 25 0 °C dBm 1500 Ω || -6,7 pF 1700 Ω || -7,1 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 70H29A is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme. Data typ. value tolerance / limit Insertion loss (reference level) ae 24,5 dB Centre frequency fC 70,01 MHz max. fC ± 1,75 MHz BW Bandwidth 1 dB 3 dB 40 dB Relative attenuation ± ± dB 70,0 ± 0,09 MHz Passband fC fC fC 26 1,4 1,5 2,8 fC ± 5 fC ± 10 fC ± Group delay 3,20 3,60 5,22 MHz MHz MHz min. min. max. 3,0 3,5 5,6 MHz MHz MHz 0,4 0,6 2,5 dB dB dB max. max. max. 0,8 1 3 dB dB dB 50 48 56 2,45 dB dB dB µs min. min. min max. min. 40 45 50 3 2 dB dB dB µs µs 40 ns max. 90 ns ° max. 4 arel … fC MHz … fC MHz … fC ± ± ± MHz … fC MHz … fC MHz … fC ± ± ± 1,4 1,5 1,75 5 10 30 MHz MHz MHz MHz MHz MHz mean value in PB Group delay ripple within PB 2,2 Deviation from linear phase within PB Triple transit response suppression 54 dB - Crosstalk attenuation compared to main signal 55 dB - Operating temperature range Storage temperature range Frequency inversion temperature OTR - - 40 °C ... + 85°C - - 55 °C ... + 85°C 30 °C ° 2 TCf ** - 0,04 ppm/K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference Temperature coefficient of frequency values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K) x (T-T0)² x fTo(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70h29a.doc Version 1.1 28.06.2004 VI TELEFILTER Filter specification TFS 70H29A 2/5 Filter characteristic 0 -8 -16 -24 B d ni e d ut i n g a m -32 B d ni e d ut i n g a m -40 -48 -56 -64 -72 -80 58 60.4 62.8 65.2 67.6 70 72.4 frequency in MHz 74.8 77.2 79.6 82 0 3.115 -1 3.04 -2 2.965 -3 2.89 -4 -7 2.815 s µ 2.74 ni y a 2.665el d 2.59 -8 2.515 -9 2.44 -5 -6 -10 68 68.4 68.8 69.2 69.6 70 70.4 frequency in MHz 70.8 71.2 71.6 2.365 72 Construction and pin connection (All dimensions in mm) TFS 70H29A 246-800124-001 ● S35 13 Max. 22,5 Max. 1 2 7 8 9 14 Input RF Return Ground Output RF Return Output Ground Input Date code: S T U ... Year + week 2004 2005 2006 Date code 7 1 6 Max. 4,5 Min. 7,62+/-0,2 5 Max. 1Dia.0,45+/-0,05 10,16+/-0,2 14 15,24+/-0,2 8 50 Ohm Test circuit 14 L1 8 L2 C1 C2 1 7 Stability characteristics : Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70h29a.doc Version 1.1 VI TELEFILTER Filter specification 28.06.2004 TFS 70H29A 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 30g, 11 ms, sawtooth, 3 shocks each plane; MIL-STD-202, Method 213 test condition K 2. Vibration: 10 Hz to 2000 Hz, 15g, 20min per cycle, 12 cycles per plan, 3 plans; MIL-STD 202, Method 204, test condition B 3. Thermal shock -40°C to 85°C, 5 cycles MIL-STD 202, Method 107, test condition A Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70h29a.doc Version 1.1 28.06.2004 VI TELEFILTER Filter specification TFS 70H29A 4/5 Air reflow temperature conditions : 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70h29a.doc Version 1.1 VI TELEFILTER Filter specification 28.06.2004 TFS 70H29A 5/5 History Version Reason of changes Name Date 1.0 filter specification created Pfeiffer 17.06.2004 1.1 operating and storage temperature range extended Pfeiffer 26.08.2004 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.