Filename: tfs 153c.doc Version 1.2 VI TELEFILTER 23.09.2005 Filter specification TFS 153C 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 63 Ω || -34 pF 55 Ω || -44 pF Characteristics Remark: The nominal frequency fN is fixed at 153,6. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation arel of the TFS153C is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range. Data typ. value Insertion loss (reference level) ae Nominal frequency fN Ripple within PB p-p Relative attenuation arel + + + 152,6 15 138,6 168,6 MHz MHz MHz MHz ... ... ... ... fN fN fN fN + + + 15 138,6 168,6 346,4 MHz MHz MHz MHz MHz ... fN + 10 MHz fN 10 MHz ... fN + 10 MHz fN 10 fN Triple transit response suppression Input power level IP3** Third order intercept - 4 10 dB 153,6 MHz 10 MHz dB max. 1 dB 45 40 70 70 dB dB dB dB min. min. min. min. 35 35 20 35 dB dB dB dB 45 ns max. 60 ns 4 deg max. 5 deg 70 dB min. 35 dB - max. 17 dBm - min. 35 dBm 10 8 dB dB . Input /Output return loss fN fN ± 12.5 p-p Phase linearity - 0,2 max. p-p Group delay ripple - dB - Passband PB fN fN fN fN 11.5 tolerance / limit MHz ... fN MHz ... fN + + 4 10 Operating temperature range MHz MHz OTR Storage temperature range Temperature coefficient of frequency TCf *** 12 9 dB dB min. min. - -25 °C..... +85 °C - -40 °C..... +85 °C -95 ppm/K - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) Measured with tones spaced at 5 MHz and 10 MHz above and below fC ***) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 153c.doc Version 1.2 VI TELEFILTER 23.09.2005 Filter specification TFS 153C 2/5 Filter characteristic 1.27 -0.6 1.225 -0.9 1.18 -1.2 1.135 -1.5 1.09 -1.8 1.045 -2.1 1 -2.4 0.955 -2.7 0.91 -18 magnitude in dB -24 -30 -36 -42 -48 -54 -60 delay in µs 0 -0.3 -12 magnitude in dB 1.315 0 -6 0.865 -3 141.6 144 146.4 148.8 151.2 153.6 156 158.4 160.8 163.2 165.6 frequency in MHz 128.6 133.6 138.6 143.6 148.6 153.6 158.6 163.6 168.6 173.6 178.6 frequency in MHz Construction and pin connection (All dimensions in mm) TFS 153C ● S25 6,8Max. 13,6Max. 2,54 ±0,15 1,5 2,54 ±0,15 1 2 3 4 2,0Max. 1 12 5 11 6 Date code 10 9 8 7 0,8 0,1 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return Date code: S T U ... Year + week 2004 2005 2006 50 Ohm Test circuit L2 L1 11 Input 50 Ohm 5 Output 50 Ohm SAW C2 C1 1,2,3,4,6,7,8,9,10,12 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 153c.doc Version 1.2 VI TELEFILTER 23.09.2005 Filter specification TFS 153C 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 1700 min. 300 mm min. 500 mm min. 300 mm EMBOSSED CARRIER TAPE Tape (all dimensions in mm) W : 24,00 +0,30/-0,10 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 11,50 ± 0,10 G(min) : 0,60 Ct P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 Ao : 7,10 ± 0,10 Bo : 13,90 ± 0,10 Ct : 21,5 ± 0,1 Do Po P2 E Ao F D1 W Bo G P1 COVER TAPE W 2 Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Marking of the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on the right. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 153c.doc Version 1.2 VI TELEFILTER 23.09.2005 Filter specification TFS 153C 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile pre-heating periods main-heating periods 150 °C - 170 °C over 200 °C 60 sec. - 90 sec. 20 sec. - 25 sec. Name: Temperature: Time: peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 153c.doc VI TELEFILTER Version 1.2 Filter specification 23.09.2005 TFS 153C 5/5 History Version Reason of Changes Name Date 1.0 - generation of specification according to customer requirements Roizengaft 02.02.2004 1.1 - generated filter specification - added termination impedances - added typical values - changed insertion loss - changed group delay ripple - changed phase linearity - changed input/output return loss - changed IP3 description - changed storage temperature range - deleted description for power level - added filter characteristic - changed construction and pin connection - added test circuit - changed packing Chilla 15.06.2004 1.2 - added temperature coefficient of frequency Chilla 23.09.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.