LPS-100 100W Single Output without PFC Function series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fix switching frequency at 134KHz 3 years warranty SPECIFICATION MODEL OUTPUT LPS-100-3.3 LPS-100-5 LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48 DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 20A 20A 13.3A 8.4A 7.5A 6.7A 4.2A 3.8A 2.1A CURRENT RANGE 0 ~ 20A 0 ~ 20A 0 ~ 13.3A 0 ~ 8.4A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 4.2A(6A 10s) 0 ~ 3.8A 0 ~ 2.1A RATED POWER 66W 100W 99.75W 100.8W 101.25W 100.5W 100.8W(144W 10s) 102.6W 100.8W RIPPLE & NOISE (max.) Note.2 150mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE 4.5 ~ 5.7V 3.0% 6 ~ 9V 2.0% 10 ~ 13.2V 2.0% 12 ~ 15V 2.0% 13.5 ~ 18V 2.0% 20 ~ 26.4V 1.0% 26 ~ 32V 1.0% 41 ~ 56V 1.0% 3 ~ 3.6V VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION INPUT 0.5% 0.5% 0.5% 1.5% 0.5% 0.5% 0.5% 88 ~ 132VAC / 176 ~ 264VAC auto switch FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 69% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.3A/115VAC 0.5% 20ms/115VAC at full load 77% 248 ~ 370VDC 77% 79% 79% 80% COLD START 30A/115VAC <1mA / 240VAC OVERLOAD 105 ~ 140% (+24V: above 6.5A) rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 80% 81% 81% 1.5A/230VAC LEAKAGE CURRENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 60A/230VAC 5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A MTBF 203.6Khrs min. MIL-HDBK-217F (25 222*62*32mm (L*W*H) 0.45Kg; 24pcs/12.5Kg/1.39CUFT DIMENSION PACKING NOTE 0.5% 20ms/230VAC ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT OTHERS 0.5% 1.5% 1.5% 1.5% 1200ms, 50ms/115VAC at full load VOLTAGE RANGE WORKING TEMP. WORKING HUMIDITY (Note 4) 0.5% HOLD UP TIME (Typ.) OVER VOLTAGE EMC 0.5% 2.0% 2.0% 800ms, 50ms/230VAC PROTECTION SAFETY & 0.5% LOAD REGULATION SETUP, RISE TIME ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24). 6. Mounting holes M1 and M2 should be grounded for EMI purposes. File Name:LPS-100-SPEC 2008-03-25 LPS-100 100W Single Output without PFC Function Mechanical Specification series Unit:mm 222 212 5 5 FG CN2 8 7 6 5 4 3 2 1 AC FUSE F4A/250V 1 2 3 4 5 52 62 CN1 4- +V ADJ. 3max. 32 3.5 AC Input Connector (CN1) : JST B5P-VH or equivalent Assignment FG No pin AC/N AC/L Pin No. 1 2,4 3 5 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B8P-VH or equivalent Pin No. 1,2,3,4 5,6,7,8 Assignment +V -V Terminal JST SVH-21T-P1.1 or equivalent Mating Housing JST VHR or equivalent Block Diagram fosc : 135KHz RECTIFIERS & FILTER 115/230VAC AUTO SWITCH EMI FILTER I/P FG O.L.P. Derating Curve RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT PWM CONTROL O.V.P. Static Characteristics (12V) Ta=25 100 300 +12V OUTPUT VOLTAGE (V) 12 80 LPS-100-5V LOAD (%) 60 Convection (3.3V,7.5V~48V) 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 250 11 200 10 150 9 100 +12V 8 50 7 25 60 80 100 120 140 160 180 200 220 240 OUTPUT RIPPLE (mVp-p) 13 18 CFM min Forced Air 260 INPUT VOLTAGE (V) 60Hz File Name:LPS-100-SPEC 2008-03-25