MEANWELL LPS-100-13.5

LPS-100
100W Single Output without PFC Function
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fix switching frequency at 134KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
LPS-100-3.3 LPS-100-5
LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
20A
20A
13.3A
8.4A
7.5A
6.7A
4.2A
3.8A
2.1A
CURRENT RANGE
0 ~ 20A
0 ~ 20A
0 ~ 13.3A
0 ~ 8.4A
0 ~ 7.5A
0 ~ 6.7A
0 ~ 4.2A(6A 10s) 0 ~ 3.8A
0 ~ 2.1A
RATED POWER
66W
100W
99.75W
100.8W
101.25W
100.5W
100.8W(144W 10s) 102.6W
100.8W
RIPPLE & NOISE (max.) Note.2 150mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.7V
3.0%
6 ~ 9V
2.0%
10 ~ 13.2V
2.0%
12 ~ 15V
2.0%
13.5 ~ 18V
2.0%
20 ~ 26.4V
1.0%
26 ~ 32V
1.0%
41 ~ 56V
1.0%
3 ~ 3.6V
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION
INPUT
0.5%
0.5%
0.5%
1.5%
0.5%
0.5%
0.5%
88 ~ 132VAC / 176 ~ 264VAC auto switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
69%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.3A/115VAC
0.5%
20ms/115VAC at full load
77%
248 ~ 370VDC
77%
79%
79%
80%
COLD START 30A/115VAC
<1mA / 240VAC
OVERLOAD
105 ~ 140% (+24V: above 6.5A) rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
80%
81%
81%
1.5A/230VAC
LEAKAGE CURRENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
60A/230VAC
5.75 ~ 6.75V 9.4 ~ 10.9V
13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V
27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
MTBF
203.6Khrs min. MIL-HDBK-217F (25
222*62*32mm (L*W*H)
0.45Kg; 24pcs/12.5Kg/1.39CUFT
DIMENSION
PACKING
NOTE
0.5%
20ms/230VAC
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
OTHERS
0.5%
1.5%
1.5%
1.5%
1200ms, 50ms/115VAC at full load
VOLTAGE RANGE
WORKING TEMP.
WORKING HUMIDITY
(Note 4)
0.5%
HOLD UP TIME (Typ.)
OVER VOLTAGE
EMC
0.5%
2.0%
2.0%
800ms, 50ms/230VAC
PROTECTION
SAFETY &
0.5%
LOAD REGULATION
SETUP, RISE TIME
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24).
6. Mounting holes M1 and M2 should be grounded for EMI purposes.
File Name:LPS-100-SPEC 2008-03-25
LPS-100
100W Single Output without PFC Function
Mechanical Specification
series
Unit:mm
222
212
5
5
FG
CN2
8
7
6
5
4
3
2
1
AC FUSE
F4A/250V
1
2
3
4
5
52
62
CN1
4-
+V ADJ.
3max.
32
3.5
AC Input Connector (CN1) : JST B5P-VH or equivalent
Assignment
FG
No pin
AC/N
AC/L
Pin No.
1
2,4
3
5
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
DC Output Connector (CN2) : JST B8P-VH or equivalent
Pin No.
1,2,3,4
5,6,7,8
Assignment
+V
-V
Terminal
JST SVH-21T-P1.1
or equivalent
Mating Housing
JST VHR
or equivalent
Block Diagram
fosc : 135KHz
RECTIFIERS
&
FILTER
115/230VAC
AUTO
SWITCH
EMI
FILTER
I/P
FG
O.L.P.
Derating Curve
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Static Characteristics (12V)
Ta=25
100
300
+12V
OUTPUT VOLTAGE (V)
12
80
LPS-100-5V
LOAD (%)
60
Convection
(3.3V,7.5V~48V)
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
250
11
200
10
150
9
100
+12V
8
50
7
25
60
80
100
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
13
18 CFM min
Forced Air
260
INPUT VOLTAGE (V) 60Hz
File Name:LPS-100-SPEC 2008-03-25