Filename: tfs 45c.doc Version 1.1 VI TELEFILTER 13.07.2006 Filter specification TFS 45C 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 1410 Ω || -25,7 pF 1660 Ω || -22,4 pF Characteristics Remark: The nominal frequency fN is fixed at 45,0 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation arel of the TFS 45C is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range. Data typ. value Insertion loss (reference level) ae 5,2 Nominal frequency fN - Centre frequency fC 45,00 Passband - Pass band ripple 0,1 dB dB ± ± ± ± ± 100 475 1 3 10 max. MHz 7,0 dB 45,00 MHz max. ± 20,0 kHz fC ± 100,0 kHz dB max. kHz min. max. 0,5 1,5 27 44 49 80 dB dB dB dB dB dB max. max. min. min. min. min. 1,5 3 20 30 35 44 dB dB dB dB dB dB 2 µs max. 2,7 µs 150 ns max. 761 1,5 dB kHz kHz MHz MHz MHz 340 950 kHz kHz arel Relative attenuation fC fC fC fC fC fC dB BW Bandwidth 3 20 tolerance / limit … fC fC ... fC ... fC ... fC ... fC ± ± ± ± ± ± 100 170 1 3 10 25 Group delay kHz kHz MHz MHz MHz MHz mean value in PB Group delay ripple within PB Operating temperature range OTR Storage temperature range Frequency inversion temperature Temperature coefficient of frequency TCf ** 300 - - 30 °C ... + 85°C - - 45 °C ... + 95°C 30 °C -0,04 ppm/K ns 2 - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K) x (T-T0)2 x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 45c.doc Version 1.1 VI TELEFILTER 13.07.2006 Filter specification TFS 45C 2/5 0 4.16 -1 3.92 -20 -2 3.68 -30 -3 3.44 -40 -4 3.2 -5 2.96 -6 2.72 -70 -7 2.48 -80 -8 2.24 -90 -9 2 -50 -60 -100 30.42 33.336 36.252 39.168 42.084 45 47.916 frequency in MHz 50.832 53.748 56.664 -10 44.75 59.58 44.8 44.85 44.9 44.95 45 45.05 frequency in MHz 45.1 45.15 45.2 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 1.76 45.25 Construction and pin connection (All dimensions in mm) TFS 45C ● U28 9 ±0,2 24,64 ±0,2 1 2,31 3,53X4,83 1 2 3 4 5 2,6 Max. Date code 10 9 8 7 6 1,02 1,91 ±0,2 1 2 3 4 5 6 7 8 9 10 Input Ground Ground Ground Output RF Return Output Ground Ground Ground Input RF Return Date code: U V W ... Year + week 2006 2007 2008 50 Ohm Test circuit 1 L1 10 6 SAW L2 L3 5 L4 2, 3, 4, 7, 8, 9 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 45c.doc Version 1.1 VI TELEFILTER 13.07.2006 Filter specification TFS 45C 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: Pull Off Direction Ko Date Code P1 P2 Ao Bo Po Ct So Do E t W Tape (all dimensions in mm) W : 44,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 20,20 ± 0,15 P2 : 2,00 ± 0,15 P1 : 16,00 ± 0,1 D1(min) : 2,00 Ao : 9,30 ± 0,1 Bo : 24,90 ± 0,1 So : 40,40 ± 0,1 Ct : 38,0 ± 0,1 1000 min. 300 mm min. 500 mm min. 300 mm Type PIN Marker D1 W2 Reel (all dimensions in mm) A : 330 W1 : 44,4 +2/-0 W2(max) : 50,4 N(min) : 100 C : 13,0 +0,5/-0,2 C A N W1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 45c.doc Version 1.1 VI TELEFILTER 13.07.2006 Filter specification TFS 45C 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 45c.doc VI TELEFILTER Version 1.1 Filter specification 13.07.2006 TFS 45C 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 22.05.2006 1.1 - terminating impedance, typical values, filter characteristic and matching configuration added Pfeiffer 13.07.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.