TFS45C

Filename: tfs 45c.doc
Version 1.1
VI TELEFILTER
13.07.2006
Filter specification
TFS 45C
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
1410 Ω || -25,7 pF
1660 Ω || -22,4 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 45,0 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation
arel of the TFS 45C is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter
attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
Insertion loss
(reference level)
ae
5,2
Nominal frequency
fN
-
Centre frequency
fC
45,00
Passband
-
Pass band ripple
0,1
dB
dB
±
±
±
±
±
100
475
1
3
10
max.
MHz
7,0
dB
45,00
MHz
max.
±
20,0
kHz
fC
± 100,0
kHz
dB
max.
kHz
min.
max.
0,5
1,5
27
44
49
80
dB
dB
dB
dB
dB
dB
max.
max.
min.
min.
min.
min.
1,5
3
20
30
35
44
dB
dB
dB
dB
dB
dB
2
µs
max.
2,7
µs
150
ns
max.
761
1,5
dB
kHz
kHz
MHz
MHz
MHz
340
950
kHz
kHz
arel
Relative attenuation
fC
fC
fC
fC
fC
fC
dB
BW
Bandwidth
3
20
tolerance / limit
… fC
fC
... fC
... fC
... fC
... fC
±
±
±
±
±
±
100
170
1
3
10
25
Group delay
kHz
kHz
MHz
MHz
MHz
MHz
mean value in PB
Group delay ripple within PB
Operating temperature range
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
TCf **
300
-
- 30 °C ... + 85°C
-
- 45 °C ... + 95°C
30
°C
-0,04
ppm/K
ns
2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0)2 x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 45c.doc
Version 1.1
VI TELEFILTER
13.07.2006
Filter specification
TFS 45C
2/5
0
4.16
-1
3.92
-20
-2
3.68
-30
-3
3.44
-40
-4
3.2
-5
2.96
-6
2.72
-70
-7
2.48
-80
-8
2.24
-90
-9
2
-50
-60
-100
30.42
33.336
36.252
39.168
42.084
45
47.916
frequency in MHz
50.832
53.748
56.664
-10
44.75
59.58
44.8
44.85
44.9
44.95
45
45.05
frequency in MHz
45.1
45.15
45.2
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
1.76
45.25
Construction and pin connection
(All dimensions in mm)
TFS 45C
●
U28
9 ±0,2
24,64 ±0,2
1
2,31
3,53X4,83
1 2 3 4 5
2,6 Max.
Date code
10 9 8 7 6
1,02
1,91 ±0,2
1
2
3
4
5
6
7
8
9
10
Input
Ground
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Input RF Return
Date code:
U
V
W
...
Year + week
2006
2007
2008
50 Ohm Test circuit
1
L1
10
6
SAW
L2
L3
5
L4
2, 3, 4, 7, 8, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 45c.doc
Version 1.1
VI TELEFILTER
13.07.2006
Filter specification
TFS 45C
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
Pull Off Direction
Ko
Date Code
P1
P2
Ao
Bo
Po
Ct
So
Do
E
t
W
Tape (all dimensions in mm)
W
: 44,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 20,20 ± 0,15
P2
: 2,00 ± 0,15
P1
: 16,00 ± 0,1
D1(min)
: 2,00
Ao
: 9,30 ± 0,1
Bo
: 24,90 ± 0,1
So
: 40,40 ± 0,1
Ct
: 38,0 ± 0,1
1000
min. 300 mm
min. 500 mm
min. 300 mm
Type
PIN Marker
D1
W2
Reel (all dimensions in mm)
A
: 330
W1
: 44,4 +2/-0
W2(max) : 50,4
N(min)
: 100
C
: 13,0 +0,5/-0,2
C
A
N
W1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 45c.doc
Version 1.1
VI TELEFILTER
13.07.2006
Filter specification
TFS 45C
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 45c.doc
VI TELEFILTER
Version 1.1
Filter specification
13.07.2006
TFS 45C
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
22.05.2006
1.1
- terminating impedance, typical values, filter characteristic and matching configuration added
Pfeiffer
13.07.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.