CDC329A 1-LINE TO 6-LINE CLOCK DRIVER WITH SELECTABLE POLARITY SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998 D D D D D D D D D PACKAGE (TOP VIEW) Low Output Skew for Clock-Distribution and Clock-Generation Applications TTL-Compatible Inputs and CMOS-Compatible Outputs Distributes One Clock Input to Six Clock Outputs Polarity Control Selects True or Complementary Outputs Distributed VCC and GND Pins Reduce Switching Noise High-Drive Outputs (– 32-mA IOH, 32-mA IOL) State-of-the-Art EPIC-ΙΙB BiCMOS Design Significantly Reduces Power Dissipation Package Options Include Plastic Small-Outline (D) GND 1Y2 2Y1 GND 2Y2 3Y GND 4Y 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 1Y1 1T/C VCC 2T/C A VCC 3T/C 4T/C description The CDC329A contains a clock-driver circuit that distributes one input signal to six outputs with minimum skew for clock distribution. Through the use of the polarity-control inputs (T/C), various combinations of true and complementary outputs can be obtained. The CDC329A is characterized for operation from – 40°C to 85°C. FUNCTION TABLE INPUTS T/C A OUTPUT Y L L L L H H H L H H H L logic symbol† A 1T/C 2T/C 3T/C 4T/C 12 1 15 13 N1 1 N2 2 2 10 N3 9 N4 3 4 16 2 3 5 6 8 1Y1 1Y2 2Y1 2Y2 3Y 4Y † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. EPIC-ΙΙB is a trademark of Texas Instruments Incorporated. Copyright 1998, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 CDC329A 1-LINE TO 6-LINE CLOCK DRIVER WITH SELECTABLE POLARITY SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998 logic diagram (positive logic) 1T/C 15 16 2 2T/C A 4T/C 1Y2 13 3 2Y1 12 5 3T/C 1Y1 10 9 6 8 2Y2 3Y 4Y absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Voltage range applied to any output in the high state or power-off state, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 mA Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –18 mA Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 50 mA Maximum power dissipation at TA = 55°C (in still air) (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.77 W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed. 2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 300 mils. For more information, refer to the Package Thermal Considerations application note in the 1994 ABT Advanced BiCMOS Technology Data Book, literature number SCBD002B. 2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 CDC329A 1-LINE TO 6-LINE CLOCK DRIVER WITH SELECTABLE POLARITY SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998 recommended operating conditions (see Note 3) MIN NOM MAX UNIT 4.75 5 5.25 V VCC VIH Supply voltage VIL VI Low-level input voltage IOH IOL High-level output current VCC – 32 mA Low-level output current 32 mA ∆t / ∆v Input transition rise or fall rate fclock TA Input clock frequency High-level input voltage 2 V 0.8 Input voltage 0 Operating free-air temperature – 40 V V 5 ns / V 80 MHz 85 °C NOTE 3: Unused inputs must be held high or low to prevent them from floating. electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VIK VOH VCC = 4.75 V, VCC = 4.75 V, II = –18 mA IOH = – 32 mA VOL II VCC = 4.75 V, VCC = 5.25 V, IOL = 32 mA VI = VCC or GND ICC VCC = 5 5.25 25 V V, VI = VCC or GND GND, MIN TYP† MAX UNIT –1.2 V 3.85 IO = 0 0, V 0.55 V ±1 µA Outputs high 10 Outputs low 40 Ci VI = 2.5 V or 0.5 V † All typical values are at VCC = 5 V, TA = 25°C 3 mA pF switching characteristics over recommended ranges of supply voltage and operating free-air temperature (see Figures 1 and 2) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A Any Y tPLH tPHL T/C Any Y tsk(o) k( ) A TYP MAX 2 5.9 1.7 5.9 1.5 5 1.5 5 Any Y (same phase) 0.6 Any Y (any phase) 1.5 tr tf POST OFFICE BOX 655303 MIN • DALLAS, TEXAS 75265 UNIT ns ns ns 1.3 ns 0.85 ns 3 CDC329A 1-LINE TO 6-LINE CLOCK DRIVER WITH SELECTABLE POLARITY SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998 PARAMETER MEASUREMENT INFORMATION From Output Under Test CL = 50 pF (see Note A) 500 Ω LOAD CIRCUIT FOR OUTPUTS 3V Input (see Note B) 1.5 V 1.5 V 0V tPHL tPLH Output 70% 30% 50% VCC tr 70% 30% VOH VOL tf VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES NOTES: A. CL includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns. Figure 1. Load Circuit and Voltage Waveforms 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 CDC329A 1-LINE TO 6-LINE CLOCK DRIVER WITH SELECTABLE POLARITY SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998 PARAMETER MEASUREMENT INFORMATION A 1T/C 1Y1 tPLH1 tPHL1 tPLH5 tPHL5 tPLH2 tPHL2 tPLH6 tPHL6 tPLH3 tPHL3 tPHL7 tPLH7 tPLH4 tPHL4 tPHL8 tPLH8 1Y2 2T/C 2Y1 2Y2 NOTES: A. Output skew, tsk(o), from A to any Y (same phase), can be measured only between outputs for which the respective polarity-control inputs (T/C) are at the same logic level. It is calculated as the greater of: – The difference between the fastest and slowest of tPHL from A↓ to any Y (e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6) – The difference between the fastest and slowest of tPHL from A↓ to any Y (e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6) – The difference between the fastest and slowest of tPLH from A↓ to any Y (e.g., tPLHn, n = 7 to 8) – The difference between the fastest and slowest of tPHL from A↑ to any Y (e.g., tPHLn, n = 7 to 8) B. Output skew, tsk(o), from A to any Y (any phase), can be measured between outputs for which the respective polarity-control inputs (T/C) are at the same or different logic levels. It is calculated as the greater of: – The difference between the fastest and slowest of tPLH from A↑ to any Y or tPHL from A↑ to any Y (e.g., tPLHn, n = 1 to 4; or tPLHn, n = 5 to 6, and tPHLn, n = 7 to 8) – The difference between the fastest and slowest of tPHL from A↓ to any Y or tPLH from A↓ to any Y (e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6, and tPLHn, n = 7 to 8) Figure 2. Waveforms for Calculation of tsk(o) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5 CDC329A 1-LINE TO 6-LINE CLOCK DRIVER WITH SELECTABLE POLARITY SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998 MECHANICAL INFORMATION D (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PIN SHOWN 0.050 (1,27) 0.020 (0,51) 0.014 (0,35) 14 0.010 (0,25) M 8 0.008 (0,20) NOM 0.244 (6,20) 0.228 (5,80) 0.157 (4,00) 0.150 (3,81) Gage Plane 0.010 (0,25) 1 7 0°– 8° A 0.044 (1,12) 0.016 (0,40) Seating Plane 0.069 (1,75) MAX 0.010 (0,25) 0.004 (0,10) PINS ** 0.004 (0,10) 8 14 16 A MAX 0.197 (5,00) 0.344 (8,75) 0.394 (10,00) A MIN 0.189 (4,80) 0.337 (8,55) 0.386 (9,80) DIM 4040047 / D 10/96 NOTES: A. B. C. D. 6 All linear dimensions are in inches (millimeters). This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion, not to exceed 0.006 (0,15). Falls within JEDEC MS-012 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated