TI CDC329AD

CDC329A
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998
D
D
D
D
D
D
D
D
D PACKAGE
(TOP VIEW)
Low Output Skew for Clock-Distribution
and Clock-Generation Applications
TTL-Compatible Inputs and
CMOS-Compatible Outputs
Distributes One Clock Input to Six Clock
Outputs
Polarity Control Selects True or
Complementary Outputs
Distributed VCC and GND Pins Reduce
Switching Noise
High-Drive Outputs (– 32-mA IOH,
32-mA IOL)
State-of-the-Art EPIC-ΙΙB  BiCMOS Design
Significantly Reduces Power Dissipation
Package Options Include Plastic
Small-Outline (D)
GND
1Y2
2Y1
GND
2Y2
3Y
GND
4Y
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
1Y1
1T/C
VCC
2T/C
A
VCC
3T/C
4T/C
description
The CDC329A contains a clock-driver circuit that distributes one input signal to six outputs with minimum skew
for clock distribution. Through the use of the polarity-control inputs (T/C), various combinations of true and
complementary outputs can be obtained.
The CDC329A is characterized for operation from – 40°C to 85°C.
FUNCTION TABLE
INPUTS
T/C
A
OUTPUT
Y
L
L
L
L
H
H
H
L
H
H
H
L
logic symbol†
A
1T/C
2T/C
3T/C
4T/C
12
1
15
13
N1
1
N2
2
2
10
N3
9
N4
3
4
16
2
3
5
6
8
1Y1
1Y2
2Y1
2Y2
3Y
4Y
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC-ΙΙB is a trademark of Texas Instruments Incorporated.
Copyright  1998, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
CDC329A
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998
logic diagram (positive logic)
1T/C
15
16
2
2T/C
A
4T/C
1Y2
13
3
2Y1
12
5
3T/C
1Y1
10
9
6
8
2Y2
3Y
4Y
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Voltage range applied to any output in the high state or power-off state,
VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 mA
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –18 mA
Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 50 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.77 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 300 mils.
For more information, refer to the Package Thermal Considerations application note in the 1994 ABT Advanced BiCMOS Technology
Data Book, literature number SCBD002B.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CDC329A
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998
recommended operating conditions (see Note 3)
MIN
NOM
MAX
UNIT
4.75
5
5.25
V
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
IOH
IOL
High-level output current
VCC
– 32
mA
Low-level output current
32
mA
∆t / ∆v
Input transition rise or fall rate
fclock
TA
Input clock frequency
High-level input voltage
2
V
0.8
Input voltage
0
Operating free-air temperature
– 40
V
V
5
ns / V
80
MHz
85
°C
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VIK
VOH
VCC = 4.75 V,
VCC = 4.75 V,
II = –18 mA
IOH = – 32 mA
VOL
II
VCC = 4.75 V,
VCC = 5.25 V,
IOL = 32 mA
VI = VCC or GND
ICC
VCC = 5
5.25
25 V
V,
VI = VCC or GND
GND,
MIN
TYP†
MAX
UNIT
–1.2
V
3.85
IO = 0
0,
V
0.55
V
±1
µA
Outputs high
10
Outputs low
40
Ci
VI = 2.5 V or 0.5 V
† All typical values are at VCC = 5 V, TA = 25°C
3
mA
pF
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (see Figures 1 and 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A
Any Y
tPLH
tPHL
T/C
Any Y
tsk(o)
k( )
A
TYP
MAX
2
5.9
1.7
5.9
1.5
5
1.5
5
Any Y (same phase)
0.6
Any Y (any phase)
1.5
tr
tf
POST OFFICE BOX 655303
MIN
• DALLAS, TEXAS 75265
UNIT
ns
ns
ns
1.3
ns
0.85
ns
3
CDC329A
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
CL = 50 pF
(see Note A)
500 Ω
LOAD CIRCUIT FOR OUTPUTS
3V
Input
(see Note B)
1.5 V
1.5 V
0V
tPHL
tPLH
Output
70%
30%
50% VCC
tr
70%
30%
VOH
VOL
tf
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns.
Figure 1. Load Circuit and Voltage Waveforms
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CDC329A
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998
PARAMETER MEASUREMENT INFORMATION
A
1T/C
1Y1
tPLH1
tPHL1
tPLH5
tPHL5
tPLH2
tPHL2
tPLH6
tPHL6
tPLH3
tPHL3
tPHL7
tPLH7
tPLH4
tPHL4
tPHL8
tPLH8
1Y2
2T/C
2Y1
2Y2
NOTES: A. Output skew, tsk(o), from A to any Y (same phase), can be measured only between outputs for which the respective polarity-control
inputs (T/C) are at the same logic level. It is calculated as the greater of:
– The difference between the fastest and slowest of tPHL from A↓ to any Y (e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6)
– The difference between the fastest and slowest of tPHL from A↓ to any Y (e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6)
– The difference between the fastest and slowest of tPLH from A↓ to any Y (e.g., tPLHn, n = 7 to 8)
– The difference between the fastest and slowest of tPHL from A↑ to any Y (e.g., tPHLn, n = 7 to 8)
B. Output skew, tsk(o), from A to any Y (any phase), can be measured between outputs for which the respective polarity-control inputs
(T/C) are at the same or different logic levels. It is calculated as the greater of:
– The difference between the fastest and slowest of tPLH from A↑ to any Y or tPHL from A↑ to any Y (e.g., tPLHn, n = 1 to 4;
or tPLHn, n = 5 to 6, and tPHLn, n = 7 to 8)
– The difference between the fastest and slowest of tPHL from A↓ to any Y or tPLH from A↓ to any Y (e.g., tPHLn, n = 1 to 4;
or tPHLn, n = 5 to 6, and tPLHn, n = 7 to 8)
Figure 2. Waveforms for Calculation of tsk(o)
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
CDC329A
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998
MECHANICAL INFORMATION
D (R-PDSO-G**)
PLASTIC SMALL-OUTLINE PACKAGE
14 PIN SHOWN
0.050 (1,27)
0.020 (0,51)
0.014 (0,35)
14
0.010 (0,25) M
8
0.008 (0,20) NOM
0.244 (6,20)
0.228 (5,80)
0.157 (4,00)
0.150 (3,81)
Gage Plane
0.010 (0,25)
1
7
0°– 8°
A
0.044 (1,12)
0.016 (0,40)
Seating Plane
0.069 (1,75) MAX
0.010 (0,25)
0.004 (0,10)
PINS **
0.004 (0,10)
8
14
16
A MAX
0.197
(5,00)
0.344
(8,75)
0.394
(10,00)
A MIN
0.189
(4,80)
0.337
(8,55)
0.386
(9,80)
DIM
4040047 / D 10/96
NOTES: A.
B.
C.
D.
6
All linear dimensions are in inches (millimeters).
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion, not to exceed 0.006 (0,15).
Falls within JEDEC MS-012
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated