ISO-CMOS ST-BUS FAMILY MT8940 T1/CEPT Digital Trunk PLL Features ISSUE 7 July 1993 Ordering Information • Provides T1 clock at 1.544 MHz locked to input frame pulse • Sources CEPT (30+2) Digital Trunk/ST-BUS clock and timing signals locked to internal or external 8 kHz signal • TTL compatible logic inputs and outputs • Uncommitted 2-input NAND gate • Single 5 volt power supply • Low power ISO-CMOS technology MT8940AC MT8940AE 24 Pin Ceramic DIP 24 Pin Plastic DIP -40°C to +85°C Description Applications • Synchronization and timing control for T1 and CEPT digital trunk transmission links • ST- BUS clock and frame pulse source The MT8940 is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT transmission link and the ST-BUS are provided by the second PLL locked to an internal or an external 8 kHz frame pulse signal. The MT8940 is fabricated in MITEL’s ISO-CMOS technology. CVb F0i Variable Clock Control DPLL #1 2:1 MUX C12i CV ENCV MS0 MS1 MS2 Frame Pulse Control Mode Selection Logic Input Selector MS3 F0b C4b 4.096 MHz Clock Control C8Kb C4o ENC4o C16i DPLL #2 C2o Clock Generator 2.048 MHz Clock Control Ai C2o ENC2o Bi Yo VDD VSS RST Figure 1 - Functional Block Diagram 3-27 27 MT8940 ISO-CMOS ENVC MS0 C12i MS1 F0i F0b MS2 C16i ENC4o C8Kb C4o VSS 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 13 VDD RST CV CVb Yo Bi Ai MS3 ENC2o C2o C2o C4b Figure 2 - Pin Connections Pin Description Pin # Name Description 1 EN CV Variable clock enable (TTL compatible input) - This input (pulled internally to VDD) directly controls the three states of CV (pin 22) under all modes of operation. When HIGH, enables CV and when LOW, puts it in high impedance condition. It also controls the three states of CVb signal (pin 21) if MS1 is LOW. When ENCV is HIGH, the pin CVb is an output and when LOW, it is in high impedance state. However, if MS1 is HIGH, CVb is always an input. 2 MS0 Mode select ‘0’ input (TTL compatible) - This input (pulled internally to VSS) in conjunction with MS1 (pin 4) selects the major mode of operation for both DPLLs. (Refer to Tables 1 and 2). 3 C12i Clock 12.355 MHz input (TTL compatible) - Master clock input at 12.355 MHz ±100ppm for DPLL #1. 4 MS1 Mode select-1 input (TTL compatible) - This input (pulled internally to VSS) in conjunction with MS0 (pin 2) selects the major mode of operation for both DPLLs. (Refer to Tables 1 and 2) 5 F0i Frame pulse input (TTL compatible) - This is the frame pulse input (pulled internally to VDD) at 8 kHz. The DPLL #1 locks to the falling edge of this input to generate T1 (1.544 MHz) clock. 6 F0b Frame pulse Bidirectional (TTL compatible input and Totem-pole output) - Depending on the minor mode selected for the DPLL #2, it provides the 8 kHz frame pulse output or acts as an input (pulled internally to VDD) to an external frame pulse. 7 MS2 Mode select-2 input (TTL compatible) - This input (pulled internally to VDD) in conjunction with MS3 (pin 17) selects the minor mode of operation for the DPLL #2. (Refer to Table 3.) 8 C16i Clock 16.388 MHz input (TTL compatible) - Master clock input at 16.388 MHz±32 ppm for DPLL #2. 9 ENC4o Enable 4.096 MHz clock (TTL compatible input) - This active high input (pulled internally to VDD) enables C4o (pin 11) output. When LOW, the output C4o is in high impedance condition. 3-28 ISO-CMOS MT8940 Pin Description (continued) Pin # Name Description 10 C8Kb Clock 8 kHz- Bidirectional (TTL compatible input and open drain output with 100K internal resistor to VDD) - This is the 8 kHz input signal on the rising edge of which DPLL #2 locks during its NORMAL mode. When DPLL #2 is in SINGLE CLOCK mode, this pin outputs an 8 kHz signal provided by DPLL #1, which is also connected internally to DPLL #2. 11 C4o Clock 4.096 MHz (Three state output) - This is the inverse of the signal appearing on pin 13 (C4b) at 4.096 MHz and has a rising edge in the frame pulse (F0b) window. The high impedance state of this output is controlled by ENC4o (pin 9). 12 VSS Ground (0 Volt) 13 C4b Clock 4.096 MHz- Bidirectional (TTL compatible input and Totem-pole output) - When the mode select bit MS3 (pin 17) is HIGH, it provides the 4.096 MHz clock output with the falling edge in the frame pulse (F0b) window. When pin 17 is LOW, C4b is an input (pulled internally to VDD) to an external clock at 4.096 MHz. 14 C2o Clock 2.048 MHz (Three state output) - This is the divide by two output of C4b (pin 13) and has a falling edge in the frame pulse (F0b) window. The high impedance state of this output is controlled by ENC2o (pin 16). 15 C2o Clock 2.048 MHz (Three state output) - This is the divide by two output of C4b (pin 13) and has a rising edge in the frame pulse (F0b) window. The high impedance state of this output is controlled by ENC2o (pin 16). 16 ENC2o Enable 2.048 MHz clock (TTL compatible input) - This active high input (pulled internally to VDD) enables both C2o and C2o outputs (pins 14 and 15). When LOW, these outputs are in high impedance condition. 17 MS3 Mode select 3 input (TTL compatible) - This input (pulled internally to VDD) in conjunction with MS2 (pin 7) selects the minor mode of operation for DPLL #2. (Refer to Table 3.) 18,19 Ai, Bi Inputs A and B (TTL compatible) -These are the two inputs (pulled internally to VSS) of the uncommitted NAND gate. 20 Yo 21 CVb Variable clock Bidirectional (TTL compatible input and Totem-pole output) - When acting as an output (MS1-LOW) during the NORMAL mode of DPLL #1, this pin provides the 1.544 MHz clock locked to the input frame pulse F0i (pin 5). When MS1 is HIGH, it is an input (pulled internally to VDD) to an external clock at 1.544 MHz or 2.048 MHz to provide the internal signal at 8 kHz to DPLL #2. 22 CV Variable clock (Three state output) - This is the inverse output of the signal appearing on pin 21, the high impedance state of which is controlled ENCV (pin 1). 23 RST Reset (Schmitt trigger input) -This input (active LOW) evokes reset condition for the device. 24 VDD VDD (+5V) Power supply. Output Y (Totem pole output) - Output of the uncommitted NAND gate. 3-29 MT8940 ISO-CMOS Functional Description The MT8940 is a dual digital phase-locked loop providing the timing and synchronization signals to the interface circuits for T1 and CEPT (30+2) Primary Multiplex Digital Transmission links. As shown in Figure 1, it has two digital phase-locked loops (DPLLs), associated output controls and the mode selection logic circuits. The two DPLLs, although similar in principle, operate independently to provide T1 (1.544 MHz) and CEPT (2.048 MHz) transmission clocks, and ST-BUS timing signals. The principle of operation behind the two DPLLs is shown in Figure 3. A master clock is divided down to 8 kHz where it is compared with the 8 kHz input, and depending on the output of the phase comparison, the master clock frequency is corrected. The MT8940 achieves the frequency correction in both directions by using the master clock at a slightly higher frequency and dividing it unaltered or stretching its period (at two discrete instants in a frame) before the division depending on the phase comparison output. When the input frequency is Master Clock (12.355 MHz/ 16.388 MHz) Frequency Correction The phase sampling is done once in a frame (8 kHz) and the divisions are set at 8 and 193 for DPLL #1, which locks on to the falling edge of the input at 8 kHz to generate T1 (1.544 MHz) clock. Although the phase sampling duration is the same for DPLL #2, the divisions are set at 8 and 256 to provide the CEPT/ST-BUS clock at 2.048 MHz synchronized to the rising edge of the input signal (8 kHz). The master clock source is specified to be at 12.355 MHz ±100 ppm for DPLL #1 and 16.388 MHz ±32 ppm for DPLL #2 over the entire temperature range of operation. The inputs MS0 to MS3 are used to select the operating mode of the MT8940, see Tables 1 to 4. All the outputs are individually controlled to the high impedance condition by their respective enable controls. The uncommitted NAND gate is available for use in applications involving MITEL’s MT8976/MH89760 (T1 interfaces) and MT8979/MH89790 (CEPT interfaces). Modes of Operation The operation of the MT8940 is categorized into major and minor modes. The major modes are defined for both DPLLs by the mode select pins MS0 and MS1. The minor modes are selected by MS2 and MS3, and are applicable only to DPLL #2. There are no minor modes for DPLL #1. ÷8 Output (1.544 MHz / 2.048 MHz) Input (8 kHz) Phase Comparison ÷193 / ÷256 Figure 3 - DPLL Principle higher, the unchanged master clock is divided, thus effectively speeding-up the locally generated clock and eventually pulling it in synchronization with the input. If the input frequency is lower than the divided master clock, the period of the master clock is stretched by half a cycle, at two discrete instants in a phase sampling period. This introduces a total delay of one master clock period over the sampling duration, which is then divided to generate the local signal synchronous with the input. Once the output is phase-locked to the active edge of the input, the circuit will maintain the locked condition as long as the input frequency is within the lock-in range (±1.04 Hz) of the DPLLs. The lock-in range is wide enough to meet the CCITT line rate specification (1.544 MHz±130ppm and 2.048 MHz ±50ppm) for the High Capacity Terrestrial Digital Service. 3-30 Major modes of the DPLL #1 DPLL #1 can be operated in three major modes as selected by MS0 and MS1 (Table 1). When MS1 is LOW, it is in NORMAL mode, which provides a T1 (1.544 MHz) clock signal locked to the falling edge of the input frame pulse F0i (8 kHz). DPLL#1 requires a master clock input of 12.355 MHz±100 ppm (C12i). In the second and third major modes (MS1 is HIGH), DPLL #1 is set to DIVIDE an external 1.544 MHz or 2.048 MHz signal applied at CVb (pin 21). The division can be set by MS0 to be either 193 (LOW) or 256 (HIGH). In these modes, the 8 kHz output is connected internally to DPLL #2, which operates in SINGLE CLOCK mode. Major modes of the DPLL #2 There are four major modes for DPLL #2 selectable by MS0 and MS1, as shown in Table 2. In all these modes DPLL #2 provides the CEPT PCM 30 timing, and the ST-BUS clock and framing signals. In NORMAL mode, DPLL #2 provides the CEPT and ST-BUS compatible timing signals locked to the rising edge of the 8 kHz input signal (C8Kb). These ISO-CMOS signals are the 4.096 MHz (C4o and C4b) and the 2.048 MHz (C2o and C2o) clocks, and the 8 kHz MS0 MS1 Mode of operation X 0 NORMAL 0 1 Note: 1 1 DIVIDE-1 DIVIDE-2 Function Provides the T1 (1.544 MHz) clock synchronized to the falling edge of the input frame pulse (F0i). DPLL #1 divides the CVb input by 193. The divided output is connected to DPLL #2. DPLL #1 divides the CVb input by 256. The divided output is connected to DPLL #2. X: indicates don’t care MS0 MS1 Mode of operation 0 0 NORMAL 1 0 0 1 1 1 Table 1. Major Modes of the DPLL #1 frame pulse (F0b), which are derived from the 16.388 MHz master clock. This mode can also provide the ST-BUS timing and framing signals with the input (C8Kb) tied HIGH and the master clock set at 16.384 MHz. The DPLL makes no correction in this configuration and provides the timing signals compatible to the ST-BUS format without any jitter. In FREE-RUN mode, DPLL #2 generates CEPT and ST-BUS timing and framing signals with no external inputs except the master clock set at 16.388 MHz. Since the master clock source is set at a higher frequency than the nominal value, the DPLL makes the necessary corrections to deliver the averaged timing signals compatible to the ST-BUS format. The operation of DPLL #2 in SINGLE CLOCK-1 mode is identical to SINGLE CLOCK-2 mode, providing the CEPT and ST-BUS compatible timing signals synchronized to the internal 8 kHz signal obtained from DPLL#1 in DIVIDE mode. When SINGLE CLOCK-1 mode is selected for DPLL #2, it automatically selects the DIVIDE-1 mode for DPLL #1, and thus, an external 1.544 MHz clock signal applied at CVb (pin 21) is divided by DPLL #1 to generate the internal signal at 8 kHz onto which DPLL #2 locks. Similarly when SINGLE CLOCK-2 mode is selected, DPLL #1 is in DIVIDE-2 mode, with an external signal of 2.048 MHz providing the internal 8 kHz signal to DPLL #2. In both these modes, this internal signal is available on C8Kb (pin 10) and DPLL #2 locks to its falling edge to provide the CEPT and ST-BUS compatible timing signals. This is in contrast to the Normal mode where these timing signals are synchronized with the rising edge of the 8 kHz signal on C8Kb. Minor modes of the DPLL #2 The minor modes for DPLL #2 depends upon the status of the mode select bits MS2 and MS3 (pins 7 and 17). MT8940 Function Provides ST-BUS/CEPT timing signals locked to the rising edge of the 8kHz input signal at C8Kb. FREE-RUN Provides ST-BUS timing and framing signals with no external inputs, except the master clock. SINGLE Provides the CEPT/STCLOCK-1 BUS compatible timing signals locked to the falling edge of the 8kHz internal signal provided by DPLL #1. SINGLE Provides CEPT/ST-BUS CLOCK-2 timing signals locked to the falling edge of the 8kHz internal signal provided by DPLL #1. Table 2. Major Modes of the DPLL #2 When MS3 is HIGH, DPLL #2 operates in any of the major modes as selected by MS0 and MS1. When MS3 is LOW, it overrides the major mode selected and DPLL #2 accepts an external clock of 4.096 MHz on C4b (pin 13) to provide the 2.048 MHz clocks (C2o and C2o) and the 8 kHz frame pulse (F0b) compatible with the ST-BUS format. The mode select bit MS2, controls the signal direction of F0b (pin 6). When MS2 is LOW, F0b is an input for an external frame pulse at 8 kHz. This MS2 MS3 Functional Description 1 1 0 1 0 0 1 0 Provides ST-BUS 4.096 MHz and 2.048 MHz clocks and 8kHz frame pulse depending on the major mode selected. Provides ST-BUS 4.096 MHz & 2.048 MHz clocks depending on the major mode selected while F0b acts as an input. However, the input on F0b has no effect on the operation of DPLL #2 unless it is in FREE-RUN mode. Overrides the major mode selected and accepts properly phase related external 4.096 MHz clock and 8 kHz frame pulse to provide the ST-BUS compatible clock at 2.048MHz. Overrides the major mode selected and accepts a 4.096 MHz external clock to provide the ST-BUS clock and frame pulse at 2.048 MHz and 8 kHz, respectively. Table 3. Minor Modes of the DPLL #2 input is effective only if MS3 is also LOW and C4b is accepting a 4.096 MHz external clock, which has a proper phase relationship with the external input on 3-31 MT8940 ISO-CMOS F0b (refer to Figure 15). Otherwise, the input on pin F0b will have no bearing on the operation of DPLL #2, unless it is in FREE-RUN mode as selected by MS0 and MS1. In FREE-RUN mode, the input on F0b is treated the same way as the C8Kb input in NORMAL mode. The frequency of the input signal on F0b should be 16 kHz for DPLL #2 to provide the STBUS compatible clocks at 4.096 MHz and 2.048 MHz. When MS2 is HIGH, the F0b pin provides the STBUS frame pulse output locked to the 8kHz internal or external signal as determined by the other mode select pins MS0, MS1 and MS3. Table 4 summarizes the modes of the two DPLLs. It should be noted that each of the major modes selected for DPLL #2 can have any of the minor modes, although some of the combinations are functionally similar. The required operation of both DPLL#1 and DPLL#2 must be considered when determining MS0-MS3. M O D E # MS 0 MS 1 MS 2 MS 3 0 0 0 0 0 NORMAL MODE Properly phase related External 4.096 MHz clock and 8 kHz frame pulse provide the STBUS clock at 2.048 MHz. 1 0 0 0 1 NORMAL MODE NORMAL MODE F0b is an input but has no function in this mode. 2 0 0 1 0 NORMAL MODE External 4.096 MHz provides the ST-BUS clock and Frame Pulse at 2.048 MHz and 8 kHz, respectively. Operating Modes DPLL #1 DPLL #2 NORMAL MODE: Provides the CEPT/ST-BUS compatible timing signals locked to the 8 kHz input signal (C8Kb). 3 0 0 1 1 NORMAL MODE: Provides the T1 (1.544 MHz) clock synchronized to the falling edge of the input frame pulse (F0i). 4 0 1 0 0 DIVIDE-1 MODE Same as mode ‘0’. 5 0 1 0 1 DIVIDE-1 MODE SINGLE CLOCK-1 MODE F0b is an input, but has no function in this mode. 6 0 1 1 0 DIVIDE-1 MODE Same as mode 2. DIVIDE-1 MODE: Divides the CVb input by 193. The divided output is connected to DPLL #2. SINGLE CLOCK-1 MODE: Provides the CEPT/ST-BUS compatible timing signals locked to the 8 kHz internal signal provided by DPLL #1. NORMAL MODE Same as mode ‘0’. NORMAL MODE F0b is an input and DPLL #2 locks on to it only if it is at 16 kHz to provide the ST-BUS control signals. 7 0 1 1 1 8 1 0 0 0 9 1 0 0 1 10 1 0 1 0 NORMAL MODE Same as mode 2. FREE-RUN MODE: Provides the ST-BUS timing signals with no external inputs except the master clock. 11 1 0 1 1 NORMAL MODE Provides the T1 (1.544 MHz) clock synchronized to the falling edge of input frame pulse (F0i). 12 1 1 0 0 DIVIDE-2 MODE Same as mode ‘0’. DIVIDE-2 MODE 13 1 1 0 1 SINGLE CLOCK-2 MODE: F0b is an input, but has no function in this mode. 14 1 1 1 0 15 1 1 1 1 DIVIDE-2 MODE Same as mode 2. DIVIDE-2 MODE: Divides the CVb input by 256. The divided output is connected to DPLL#2. SINGLE CLOCK-2 MODE: Provides the CEPT/ST-BUS compatible timing signals locked to the 8 kHz internal signal provided by DPLL #1. Table 4. Summary of Modes of Operation - DPLL #1 and #2 3-32 ISO-CMOS Applications The following figures illustrate how the MT8940 can be used in a minimum component count approach to providing the timing and synchronization signals for the Mitel T1 and CEPT interfaces, and the ST-BUS. The hardware selectable modes and the independent control over each PLL adds flexibility to the interface circuits. It can be easily reconfigured to provide the timing and control signals for both at the master and slave ends of the link. Synchronization and Timing Signals for the T1 Transmission Link Figures 4 and 5 show examples of how to generate the timing signals for the master and slave ends of a T1 link. At the master end of the link (Figure 4), DPLL #2 is the source of the ST-BUS signals derived from the 4.096 MHz system clock. The frame pulse output is looped back to DPLL #1 (in NORMAL mode), which locks to it to generate the T1 line clock. The timing relationship between the 1.544 MHz T1 clock and the 2.048 MHz ST-BUS clock meets the requirements of the MH89760/760B. The crystal clock at 12.355 MHz is used by DPLL #1 to generate the 1.544 MHz clock, while DPLL #2 uses the 4.096 MHz system clock to provide the ST-BUS timing signals. The ST-BUS signals can also be obtained from DPLL #2 in FREE-RUN mode, using a crystal clock at 16.388 MHz instead of 4.096 MHz system Synchronization and Timing Signals for the CEPT Transmission Link The MT8940 can be used to provide the timing and synchronization signals for the MH89790/790B, MITEL’s CEPT(30+2) digital trunk interface hybrid. Since the operational frequencies of the ST-BUS and the CEPT primary multiplex digital trunk are same, only DPLL #2 is required to achieve synchronization between the two. Figures 6 and 7 show how the MT8940 can be used to synchronize the ST-BUS and the CEPT transmission link at the master and slave ends, respectively. VDD MS0 CV F0i C12i (ST-BUS compatible) At the slave end of the link (Figure 5) both the DPLLs are in NORMAL mode with DPLL #2 providing the ST-BUS timing signals locked to the 8 kHz frame pulse (E8Ko) extracted from the received signal on the T1 line. The regenerated frame pulse is looped back to DPLL #1 to provide the T1 line clock as at the master end. The 12.355 MHz and 16.388 MHz crystal clock sources are necessary for DPLL #1 and #2. MT8940 MS1 MS2 MS3 4.096 MHz System Clock clock. The uncommitted NAND gate converts the received signals, RxA and RxB of the MH89760 to a single Return to Zero (RZ) input for the clock extraction circuits of the MH89760. This is not required for the MH89760B. The generated ST-BUS signals can be used to synchronize the system and the switching equipment at the master end. MT8980/81 Crystal Clock (12.355 MHz ±100 ppm) MT8940 C4b ENCV C8Kb C16i ENC4o ENC2o Ai Bi VSS ST-BUS SWITCH MH89760 C1.5i DSTi C2i DSTo F0i CSTi CSTo C2o TxT F0b Yo TRANSMIT RxA TxR RxB RxT RxD RxR T1 LINK (1.544 Mbps) RECEIVE RST MODE OF OPERATION FOR THE MT8940 DPLL #1 - NORMAL (MS0 = X; MS1 = 0) DPLL #2 - OVERRIDE THE MAJOR MODES (MS2 = 1; MS3 = 0) Figure 4 - Synchronization at the Master End of the T1 Transmission Link 3-33 MT8940 ISO-CMOS Crystal Clock MT8980/81 MT8940 (12.355 MHz ± 100 ppm) VDD MS0 MH89760 ST-BUS SWITCH MS1 MS2 MS3 CV C1.5i C2i F0i C12i C4b ENCV C8Kb C2o F0i DSTi DSTo CSTi CSTo TxT C16i ENC4o ENC2o Ai F0b Yo Bi VSS Crystal Clock RxA TxR RxB RxT RxD RxR TRANSMIT T1 LINK (1.544 Mbps) RECEIVE RST (16.388 MHz ± 32 ppm) Mode of Operation for the MT8940 DPLL #1 - NORMAL (MS1=0) DPLL #2 - NORMAL (MS0=0; MS1=0; MS2=1; MS3=1) Figure 5 - Synchronization at the Slave End of the T1 Transmission Link MT8980/81 MT8940 VDD MS0 ST-BUS SWITCH MH89790 MS1 MS2 MS3 C4b C2i F0i C12i 4.096 MHz System Clock ENCV C8Kb (ST-BUS Compatible) C16i C2o F0i DSTo CSTi0 CSTi1 CSTo F0b ENC4o ENC2o Ai Yo Bi VSS DSTi RST RxA OUTA RxB OUTB RxD TRANSMIT RxT RECEIVE CEPT PRIMARY MULTIPLEX DIGITAL LINK RxR Mode of Operation for the MT8940 DPLL #1 - NOT USED DPLL #2 - OVERRIDE MAJOR MODES (MS0=X; MS1=X MS2=1; MS3=0) Figure 6 - Synchronization at the Master End of the CEPT Digital Transmission Link Generation of ST-BUS Timing Signals The MT8940 can source the properly formatted STBUS timing and control signals with no external inputs except the crystal clock. This can be used as the standard timing source for ST-BUS systems or any other system with similar clock requirements. Figure 8 shows two such applications using only DPLL #2. In one case, the MT8940 is in FREE-RUN 3-34 mode with an oscillator input of 16.388 MHz. This forces the DPLL to correct at a rate of 4 kHz to maintain the ST-BUS clocks, which therefore, will be jittered. In the other case, the oscillator input is 16.384 MHz (exactly eight times the output frequency) and DPLL #2 operates in NORMAL mode with C8Kb input tied HIGH. Since no corrections are necessary, the output is free from jitter. DPLL #1 is completely free in both cases and available for any other purpose. MT8940 ISO-CMOS MT8940 MT8980/81 VDD MS0 MH89790 MS1 MS2 MS3 C4b C2i F0i C12i C2o F0i CSTi1 CSTo C16i (16.388 MHz ± 32 ppm) F0b ENC4o ENC2o Ai Yo Bi VSS DSTo CSTi0 ENCV C8Kb Crystal Clock ST-BUS SWITCH DSTi RxA OUTA RxB OUTB RxD TRANSMIT RxT RECEIVE RST CEPT PRIMARY MULTIPLEX DIGITAL LINK RxR Mode of Operation for the MT8940 DPLL #1 - NOT USED DPLL #2 - NORMAL (MS0=0; MS1=0; MS2=1; MS3=1) Figure 7 - Synchronization at the Slave End of the CEPT Digital Transmission Link MT8940 VDD MS0 DPLL #1 - NOT USED DPLL #2 - NORMAL MODE (MS0=0; MS1=0; MS2=1; MS3=1) (16.388 MHz ± 32 ppm) MS1 MS2 MS3 C4o F0i C12i C4b ST-BUS ENCV C8Kb TIMING C2o Crystal Clock C16i SIGNALS ENC4o ENC2o Ai C2o Bi F0b VSS VDD MS0 MS1 Crystal Clock MT8940 RST (16.388 MHz ± 32 ppm) DPLL #1 - NOT USED DPLL #2 - NORMAL MODE (MS0=0; MS1=0; MS2=1; MS3=1) MS2 MS3 C4o F0i C12i C4b ST-BUS ENCV C8Kb TIMING C2o C16i ENC4o ENC2o Ai C2o Bi F0b VSS SIGNALS RST Figure 8 - Generation of the ST-BUS Timing Signals 3-35 MT8940 ISO-CMOS Absolute Maximum Ratings*- Voltages are with respect to ground (VSS) unless otherwise stated. Parameter Symbol Min Max Units VDD -0.3 7.0 V VI VSS-0.5 VDD+0.5 V IIK/OK ±10 mA 1 Supply Voltage 2 Voltage on any pin 3 Input/Output Diode Current 4 Output Source or Sink Current IO ±25 mA 5 DC Supply or Ground Current IDD/ISS ±50 mA 6 Storage Temperature 150 o 7 Package Power Dissipation TST Ceramic DIP LCC -65 PD PD 1200 600 C mW mW * Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied. Recommended Operating Conditions - Voltages are with respect to ground (VSS) unless otherwise stated. Characteristics Sym Min Typ‡ Max Units 5.0 5.25 V Test Conditions 1 Supply Voltage VDD 4.75 2 Input HIGH Voltage VIH 2.4 VDD V For 400 mV noise margin 3 Input LOW Voltage VIL VSS 0.4 V For 400 mV noise margin 4 Operating Temperature TA -40 85 oC 25 ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. DC Electrical Characteristics - Voltages are with respect to ground (VSS) unless otherwise stated. VDD =5.0 V±5%; VSS=0V; TA=-40 to 85°C. Characteristics 1 S U P Supply Current Sym Min IDD IDDS Typ‡ Max Units Test Conditions 8 15 100 mA Under clocked condition, with the inputs tied to the same supply rail as the corresponding pull-up / down resistors. 2 Input HIGH voltage (For all the inputs except pin 23) VIH 2.0 V 3 Positive-going threshold voltage (For pin 23) V+ 2.8 V Input LOW voltage (For all the inputs except pin 23) VIL 0.8 V 5 Negative-going threshold voltage (For pin 23) V- 1.5 V 6 Output current HIGH (For all the outputs except pin 10) IOH -9.5 mA VOH=2.4 V Output current LOW (For all the outputs except pin 10) IOL 4.5 mA VOL=0.4 V 8 Output current LOW (pin 10) IOL 2.0 mA VOL=0.4 V 9 Leakage current on bidirectional pins and all inputs except C12i, C16i, RST IIZ/OZ ±150 µA VI/O=VSS or VDD 10 Leakage current on all outputs and C12i, C16i, RST inputs IIZ/OZ ±10 µA VI/O=VSS or VDD 4 7 I N O U T ±1 ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. 3-36 ISO-CMOS MT8940 AC Electrical Characteristics† - Voltages are with respect to ground (VSS) unless otherwise stated. (Ref. Figure 9) Characteristics Sym Min 1 Frame pulse input (F0i) to CVb output (1.544 MHz) delay tF15H -40 2 CVb output (1.544 MHz) rise time tr1.5 3 Typ‡ Max Units 75 ns 10 15 ns Test load circuit 1 (Fig. 17). 12 15 ns Test load circuit 1 (Fig. 17). D P L L CVb output (1.544 MHz) fall time tf1.5 CVb output (1.544 MHz) clock period tP15 648 690 ns #1 CVb output (1.544 MHz) clock width (HIGH) tW15H 320 386 ns 6 CVb output (1.544 MHz) clock width (LOW) tW15L 314 327 ns 7 CV delay (HIGH to LOW) t15HL 5 30 ns 8 CV delay (LOW to HIGH) t15LH -12 10 ns 4 5 Test Conditions † Timing is over recommended temperature & power supply voltages. ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. F0i VIH VIL tF15H tP15 tf1.5 tW15H CVb VOH VOL tW15L t15HL tr1.5 t15LH CV VOH VOL Figure 9 - Timing Information for DPLL #1 in NORMAL Mode AC Electrical Characteristics† - Voltages are with respect to ground (VSS) unless otherwise stated. (Ref. Figure 10) Characteristics 1 2 3 4 5 D P L L #1 Sym C8Kb output (8kHz) delay (HIGH to HIGH) tC8HH C8Kb output (8 kHz) delay (LOW to LOW) tC8LL C8Kb output duty cycle Min Typ‡ 50 Max Units Test Conditions 130 ns Test load circuit 2 (Fig. 17). 130 ns Test load circuit 2 (Fig. 17). % % In Divide -1 Mode In Divide - 2 Mode 66 50 Inverted clock output delay (HIGH to LOW) tICHL 40 75 ns Inverted clock output delay (LOW to HIGH) tICLH 35 60 ns † Timing is over recommended temperature & power supply voltages. ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. 3-37 MT8940 ISO-CMOS VIH CVb VIL tICHL tICLH VOH CV VOL tC8HH tC8LL VOH C8Kb VOL Figure 10 - DPLL #1 in DIVIDE Mode tWFP F0b VOH VOL tFPL tFPH tfC4 trC4 VOH C4b VOL t4oLH t4oHL VOH C4o VOL t42LH t42HL tP2o tW2oH tfC2 trC2 VOH C2o VOL tW2oL t2oLH t2oHL VOH C2o VOL Figure 11 - Timing Information on DPLL #2 Outputs 3-38 ISO-CMOS MT8940 AC Electrical Characteristics†-Voltages are with respect to ground (VSS) unless otherwise stated.(Ref. Figures 11&12) Typ‡ Max Units Test Conditions -25 75 ns Test load circuit 2 (Fig. 17) on C8Kb. tP4o 240 282 ns Test load circuit 1 (Fig. 17). C4b output clock width (HIGH) tW4oH 123 165 ns 4 C4b output clock width (LOW) tW4oL 110 123 ns 5 C4b output clock rise time trC4 10 ns Test load circuit 1 (Fig. 17). 6 C4b clock output fall time tfC4 10 ns Test load circuit 1 (Fig. 17). 7 Frame pulse output delay (HIGH to LOW) from C4b tFPL 50 ns 8 Frame pulse output delay (LOW to HIGH) from C4b tFPH 40 ns Frame pulse (F0b) width tWFP 245 ns C4o delay - LOW to HIGH t4oLH 45 ns C4o delay - HIGH to LOW t4oHL 45 ns C4b to C2o delay (LOW to HIGH) t42LH +10 ns 13 C4b to C2o delay (HIGH to LOW) t42HL 20 ns 14 C2o clock period tP2o 486 523 ns 15 C2o clock width (HIGH) tW2oH 244 291 ns 16 C2o clock width (LOW) tW2oL 233 244 ns 17 C2o clock rise time trC2 10 ns Test load circuit 1 (Fig. 10). 18 C2o clock fall time tfC2 10 ns Test load circuit 1 (Fig. 10). 19 C2o delay - LOW to HIGH t2oLH 20 ns 20 C2o delay - HIGH to LOW t2oHL 30 ns Characteristics Sym Min 1 C4b output delay (HIGH to LOW) from C8Kb input/output t84H 2 C4b output clock period 3 9 10 11 12 D P L L #2 200 -10 -5 Test load circuit 1 (Fig. 17). Test load circuit 1 (Fig. 17). Test load circuit 1 (Fig. 10). † Timing is over recommended temperature & power supply voltages. ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. C8Kb as Output VOH C8Kb as Input VIH VOL VIL t84H tW4oH VOH C4b VOL tP4o tFPL tFPH tW4oL VOH F0b VOL Figure 12 - ST-BUS Timings from DPLL #2 and C8Kb Input/Output 3-39 MT8940 ISO-CMOS AC Electrical Characteristics† - Voltages are with respect to ground (VSS) unless otherwise stated. (Ref. Figure 13) Characteristics 1 CV/CVb (1.544 MHz) Setup time Sym Min tS15 25 Typ‡ Max Units Test Conditions ns 2 CV/CVb (1.544 MHz) Hold time tH15 110 ns † Timing is over recommended temperature & power supply voltages. ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. VOH F0b Boundary between ST-BUS channel 2 bit 4 and channel 2 bit 3 VOL 20 CYCLES VOH C2o VOL tH15 tS15 VOH CV VOL tH15 tS15 VOH CVb VOL Figure 13 - F0b from DPLL #2 is Looped Back as Input to DPLL #1 (T1 Line synchronized to ST-BUS) AC Electrical Characteristics† - Voltages are with respect to ground (VSS) unless otherwise stated. (Ref. Figure 14) Characteristics Sym Min Typ‡ Max Units 1 Master clocks input rise time tr 10 ns 2 Master clocks input fall time tf 10 ns 3 C Master clock period L (12.355MHz) O 4 C Master clock period K (16.388MHz) S 5 Duty Cycle of master clocks 6 Lock-in Range (For each PLL) Test Conditions tP12 80.930 80.938 80.946 ns For DPLL #1, while operating to provide the T1 clock signal. tP16 61.018 61.020 61.022 ns For DPLL #2, while operating to provide the CEPT and ST-BUS timing signals. 45 50 55 % +1.04 Hz -1.5 With the Master clocks as shown above. † Timing is over recommended temperature & power supply voltages ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. tr Master clock inputs tf 2.4 V 1.5 V 0.4 V tP12 or tP16 Figure 14 - Master Clock Inputs 3-40 ISO-CMOS MT8940 AC Electrical Characteristics† - Voltages are with respect to ground (VSS) unless otherwise stated. (Ref. Figure 15) Characteristics Sym Min 1 F0b input pulse width (LOW) tWFP 40 2 C4b input clock period tP4o .080 3 Frame pulse (F0b) setup time tFS 25 Typ‡ Max Units Test Conditions ns 50 µs ns 4 Frame pulse (F0b) hold time tFH 5 ns † Timing is over recommended temperature & power supply voltages ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. tWFP VIH F0b VIL tFH VIH C4b VIL tFS tP4o Figure 15 - External Inputs on C4b and F0b for the DPLL #2 AC Electrical Characteristics† - Voltages are with respect to ground (VSS) unless otherwise stated. (Ref. Figure 16) Characteristics 1 2 3 O U T P U T 4 Sym Min Typ‡ Max Units Test Conditions Delay from Enable to Output (HIGH to THREE STATE) tPHZ 15 65 ns Test load circuit 3 (Fig.17) Delay from Enable to Output (LOW to THREE STATE) tPLZ 10 55 ns Test load circuit 3 (Fig.17) Delay from Enable to Output (THREE STATE to HIGH) tPZH 40 ns Test load circuit 3 (Fig.17) Delay from Enable to Output (THREE STATE to LOW) tPZL 50 ns Test load circuit 3 (Fig.17) † Timing is over recommended temperature & power supply voltages ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. 6 ns tf tr 6 ns 3.0 V 2.7 V 1.3 V 0.3 V Enable Input tPZL tPLZ Output LOW to OFF 1.3 V 10% tPHZ tPZH 90% Output HIGH to OFF 1.3 V Outputs Enabled Outputs Disabled Outputs Enabled Figure 16 - Three State Outputs and Enable Timings 3-41 MT8940 ISO-CMOS AC Electrical Characteristics† - Uncommitted NAND Gate Voltages are with respect to ground (VSS) unless otherwise stated. Characteristics Sym Min Typ‡ Max Units Test Conditions 1 Propagation delay (LOW to HIGH), input Ai or Bi to output tPLH 25 40 ns Test load circuit 1 (Fig. 17) 2 Propagation delay (HIGH to LOW), input Ai or Bi to output tPHL 20 40 ns Test load circuit 1 (Fig. 17) † Timing is over recommended temperature & power supply voltages. ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing. VDD VDD RL=1kΩ From output under test Test point From output under test Test point Test point From output under test A RL=1kΩ S1 B VSS CL=50pF Test load circuit- 1 CL=50pF CL=50pF Test load circuit- 2 Test load circuit- 3 Figure 17 - Test Load Circuits 3-42 Note: S1 is in position A when measuring tPLZ and tPZ and in position B when measuring tPHZ and tPZH