DATA SHEET
ZENER DIODES
RD4.7UJ to RD39UJ
LOW NOISE SHARP BREAKDOWN CHARACTERISTICS
ZENER DIODES
2PIN ULTRA SUPER MINI MOLD
DESCRIPTION
Type RD4.7UJ to RD39UJ Series are 2PIN Ultra Super Mini
PACKAGE DIMENSIONS
(Unit: mm)
Mold Package zener diodes possessing an allowable power
dissipation of 150 mW featuring low noise and sharp breakdown characteristic. They are intended for use in audio equip-
0.3±0.05
0.8±0.1
2.1±0.1
ment, instrument equipment.
1.3±0.1
FEATURES
• Low Noise
• Sharp Breakdown characteristics
• Vz; Applied E24 standard
Circuits for Constant Voltage, Constant Current, Waveform
Cathode
Indication
0.15
APPLICATIONS
0.7±0.1
clipper, Surge absorber, etc.
P
150 mW
Forward Current
IF
100 mA
Reverse Surge Power
PRSM
2.2 W
(at t = 10 µs/1 pulse)
0.11+0.05
–0.01
Power Dissipation
0±0.05
MAXIMUM RATINGS (TA = 25 °C)
Show Fig. 6
Junction Temperature
Tj
150 °C
Storage Temperature
Tstg
–55 to +150 °C
The information in this document is subject to change without notice. Before using this document, please
confirm that this is the latest version.
Not all devices/types available in every country. Please check with local NEC representative for availability
and additional information.
Document No. D13938EJ3V0DS00 (3rd edition)
(Previous No. DC-2135)
Date Published March 1999 N CP(K)
Printed in Japan
©
1993
RD4.7UJ to RD39UJ
ELECTRICAL CHARACTERISTICS (TA = 25 ± 2 °C)
Dynamic
Impedance
Zz (Ω)Note 2
Zener Voltage
Type Number
Class
N
RD4.7UJ
RD5.1UJ
RD5.6UJ
RD6.2UJ
RD6.8UJ
RD7.5UJ
RD8.2UJ
RD9.1UJ
RD10UJ
RD11UJ
RD12UJ
RD13UJ
2
Vz (V)Note 1
MIN.
MAX.
4.39
4.91
N1
4.39
4.62
N2
4.52
4.76
N3
4.66
4.91
N
4.81
5.36
N1
4.81
5.05
N2
4.95
5.20
N3
5.10
5.36
N
5.26
5.91
N1
5.26
5.54
N2
5.44
5.73
N3
5.63
5.91
N
5.81
6.53
N1
5.81
6.11
N2
6.01
6.32
N3
6.21
6.53
N
6.41
7.14
N1
6.41
6.74
N2
6.60
6.94
N3
6.80
7.14
N
7.00
7.83
N1
7.00
7.35
N2
7.21
7.60
N3
7.46
7.83
N
7.69
8.61
N1
7.69
8.08
N2
7.94
8.34
N3
8.20
8.61
N
8.47
9.51
N1
8.47
8.91
N2
8.76
9.21
N3
9.06
9.51
N
9.35
10.51
N1
9.35
9.82
N2
9.66
10.16
N3
10.00
10.51
N
10.32
11.50
N1
10.32
10.84
N2
10.64
11.17
N3
10.97
11.50
N
11.28
12.52
N1
11.28
11.83
N2
11.59
12.17
N3
11.93
12.52
N
12.29
13.86
N1
12.29
12.95
N2
12.72
13.40
N3
13.17
13.86
Reverse Current
IR (µA)
Iz (mA)
MAX.
Iz (mA)
MAX.
VR (V)
0.5
800
0.5
2
1.0
0.5
500
0.5
2
1.5
0.5
200
0.5
1
2.5
0.5
100
0.5
1
3.0
0.5
60
0.5
0.5
3.5
0.5
60
0.5
0.5
4.0
0.5
60
0.5
0.5
5.0
0.5
60
0.5
0.5
6.0
0.5
60
0.5
0.1
7.0
0.5
60
0.5
0.1
8.0
0.5
80
0.5
0.1
9.0
0.5
80
0.5
0.1
10.0
Data Sheet D13938EJ3V0DS00
RD4.7UJ to RD39UJ
Dynamic
Impedance
Zz (Ω)Note 2
Zener Voltage
Type Number
Class
Vz (V)Note 1
MIN.
RD15UJ
RD16UJ
RD18UJ
RD20UJ
RD22UJ
RD24UJ
RD27UJ
RD30UJ
RD33UJ
RD36UJ
RD39UJ
MAX.
N
13.63
15.38
N1
13.63
14.35
N2
14.12
14.85
N3
14.62
15.38
N
15.13
16.91
N1
15.13
15.87
N2
15.58
16.36
N3
16.07
16.91
N
16.63
18.81
N1
16.63
17.52
N2
17.24
18.15
N3
17.87
18.81
N
18.51
20.79
N1
18.51
19.42
N2
19.14
20.12
N3
19.80
20.79
N
20.46
22.82
N1
20.46
21.47
N2
21.09
22.15
N3
21.76
22.82
N
22.42
25.17
N1
22.42
23.59
N2
23.19
24.38
N3
23.98
25.17
N
24.75
27.95
N1
24.75
26.04
N2
25.56
26.96
N3
26.46
27.95
N
27.38
31.04
N1
27.38
29.00
N2
28.35
30.04
N3
29.37
31.04
N
30.30
33.97
N1
30.30
32.02
N2
31.21
32.98
N3
32.14
33.97
N
33.08
36.83
N1
33.08
34.92
N2
33.95
36.85
N3
34.87
36.83
N
35.78
39.67
N1
35.78
37.75
N2
36.63
38.69
N3
37.56
39.67
Reverse Current
IR (µA)
Iz (mA)
MAX.
Iz (mA)
MAX.
VR (V)
0.5
80
0.5
0.1
11
0.5
80
0.5
0.1
12
0.5
80
0.5
0.1
13
0.5
100
0.5
0.1
15
0.5
100
0.5
0.1
17
0.5
120
0.5
0.1
19
0.5
150
0.5
0.1
21
0.5
200
0.5
0.1
23
0.5
250
0.5
0.1
25
0.5
300
0.5
0.1
27
0.5
360
0.5
0.1
30
Note 1. Tested with pulse (40 ms)
2. Zz is measured at Iz by given a very small A.C. current signal
Data Sheet D13938EJ3V0DS00
3
RD4.7UJ to RD39UJ
TYPICAL CHARACTERISTICS (TA = 25 °C)
Fig. 1 P – TA RATING
200
P - Power Dissipation - mW
30×30×0.75
P.C.B. (Ceramic)
150
20×15×0.75
P.C.B. (Ceramic)
10×7.5×0.75
P.C.B. (Glass Epoxy)
100
10×7.5×0.75
P.C.B. (Ceramic)
50
0
50
100
150
200
TA - Ambient Temperature - °C
10 m
1m
100 µ
10 µ
RD15UJ
RD13UJ
RD12UJ
RD11UJ
RD10UJ
10 m
1m
100 µ
10 µ
3
4
5
6
7
8
9
Vz - Zener Voltage - V
(a)
4
RD9.1UJ
RD8.2UJ
RD7.5UJ
RD6.8UJ
100 m
Iz - Zener Current - A
Iz - Zener Current - A
100 m
RD6.2UJ
RD4.7UJ
RD5.1UJ
RD5.6UJ
Fig. 2 Iz – Vz CHARACTERISTICS (a to d)
9
10
11
12
13
Vz - Zener Voltage - V
(b)
Data Sheet D13938EJ3V0DS00
14
15
Iz - Zener Current - A
1m
100 µ
RD39UJ
RD36UJ
RD33UJ
RD30UJ
RD27UJ
RD24UJ
RD22UJ
RD20UJ
100 m
10 m
10 m
1m
100 µ
10 µ
10 µ
18
20
22
24
26
28
28
30
Vz - Zener Voltage - V
(c)
32
34
36
38
40
42
44
Vz - Zener Voltage - V
(d)
Fig. 3 γ z – Vz CHARACTERISTICS
%/°C
0.08
32
24
0.06
16
0.04
mV/°C
0.02
8
0
0
–0.02
–8
–0.04
–16
4
8
12
16
20
24
28
32
36
γZ -VZ - Temperature Coefficient - mV/°C
16
γZ -VZ - Temperature Coefficient - %/°C
Iz - Zener Current - A
100 m
RD18UJ
RD16UJ
RD4.7UJ to RD39UJ
40
VZ - Zener Voltage - V
Data Sheet D13938EJ3V0DS00
5
RD4.7UJ to RD39UJ
Fig. 4 TRANSIENT THERMAL IMPEDANCE CHARACTERISTIC
Zth – Transient Thermal Impedance – °C/W
1000
833 °C/W
100
10
1
1m
P.C.B. (Glass Epoxy)
(30mm×30 mm×1.6mm)
10 m
100 m
1
10
100
t – Time – s
Fig. 5 SURGE REVERSE POWER RATINGS
1000
TA = 25 °C
PRSM
PRSM – Surge Reverse Power – W
Repetitive
tT
100
10
1
1µ
10 µ
100µ
1m
tT – Pulse Width – s
6
Data Sheet D13938EJ3V0DS00
10 m
100 m
RD4.7UJ to RD39UJ
[MEMO]
Data Sheet D13938EJ3V0DS00
7
RD4.7UJ to RD39UJ
[MEMO]
• The information in this document is subject to change without notice. Before using this document, please
confirm that this is the latest version.
• No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in
this document.
• NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual
property rights of third parties by or arising from use of a device described herein or any other liability arising
from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights
or other intellectual property rights of NEC Corporation or others.
• Descriptions of circuits, software, and other related information in this document are provided for illustrative
purposes in semiconductor product operation and application examples. The incorporation of these circuits,
software, and information in the design of the customer's equipment shall be done under the full responsibility
of the customer. NEC Corporation assumes no responsibility for any losses incurred by the customer or third
parties arising from the use of these circuits, software, and information.
• While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices,
the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or
property arising from a defect in an NEC semiconductor device, customers must incorporate sufficient safety
measures in its design, such as redundancy, fire-containment, and anti-failure features.
• NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a
customer designated “quality assurance program“ for a specific application. The recommended applications of
a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device
before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment,
audio and visual equipment, home electronic appliances, machine tools, personal electronic
equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed
for life support)
Specific: Aircraft, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.
M7 98.8