SUPERTEX HV574PG

HV574
100 MHz, 80-Channel Serial To Parallel Converter
With Push-Pull Outputs
Ordering Information
Package Options
Device
100 Lead Quad
Plastic Gullwing
Die
HV574PG
HV574X
HV574
Features
General Description
❏ Processed with HVCMOS® technology
❏ Low power level shifting
The HV574 is a low-voltage serial to high-voltage parallel converter with push-pull outputs. This device has been designed for
use as a driver for printer applications. It can also be used in any
application requiring multiple output high-voltage current sourcing and sinking capability such as driving plasma panels, vacuum fluorescent displays, or large matrix LCD displays.
❏ 100MHz equivalent data rate using four dynamic
shift registers
The device has 4 parallel 20-bit dynamic shift registers, permitting
data rates 4X the speed of one ( they are clocked together).
❏ 5V CMOS logic
❏ Output voltages up to 80V
❏ Static latched data outputs
There are 80 static latches and control logic to perform the polarity
select and blanking of the outputs. HVOUT1 is connected to the first
stage of the first shift register through the polarity and blanking
logic. Data is shifted through the shift registers on the logic low to
high transition of the clock. The DIR pin causes CCW shifting
when connected to GND, and CW shifting when connected to
VDD. A data output buffer is provided for cascading devices. This
output reflects the current status of the last bit of the shift register
(HVOUT80). Operation of the shift register is not affected by the LE
(latch enable), BL (blanking), or the POL (polarity) inputs. Transfer of data from the shift registers to the latches occurs when the
LE (latch enable) input is high. The data in the latches is stored
when LE is low.
❏ Forward and reverse shifting options (DIR pin)
❏ Diode to VPP allows efficient power recovery
❏ Outputs may be hot switched
❏ Hi-Rel processing available
Absolute Maximum Ratings
Supply voltage, VDD1
-0.5V to +7.5V
Output voltage, VPP1
-0.5V to +90V
Logic input levels1
Ground
-0.3V to VDD +0.3V
current 2
Continuous total power dissipation 3
Operating temperature range
Storage temperature range
Lead temperature 1.6mm (1/16 inch)
from case for 10 seconds
1.5A
1200mW
-40 to 85°C
-65°C to +150°C
260°C
Notes:
1. All voltages are referenced to GND.
2. Limited by the total power dissipated in the package.
3. For operation above 25°C ambient derate linearly to 85°C at 20mW/°C.
11/12/01
Supertex Inc. does not recommend the use of its products in life support applications and will not knowingly sell its products for use in such applications unless it receives an adequate "products liability
indemnification insurance agreement." Supertex does not assume responsibility for use of devices described and limits its liability to the replacement of devices determined to be defective due to
workmanship. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest product specifications, refer to the
Supertex website: http://www.supertex.com. For complete liability information on all Supertex products,
1 refer to the most current databook or to the Legal/Disclaimer page on the Supertex website.
HV574
Electrical Characteristics (over recommended commercial operating conditions unless noted)
DC Characteristics
Symbol
Parameter
IDD
VDD supply current
IPP
Quiescent VPP supply current
IDDQ
Quiescent VDD supply current
VOH
High-level output
VOL
Low-level output
Min
Max
Units
Conditions
30
mA
VDD = VDD max
fCLK = 25MHz
100
µA
Outputs high
100
µA
Outputs low
100
µA
All VIN = VDD
HVOUT
VPP - 9V
V
IO= -30mA, VPP = 80V
Data out
VDD - 0.5
V
IO= -100µA
3.75
V
IO = 15mA, VDD = 5V
0.5
V
IO= 100µA
HVOUT
Data out
IIH
High-level logic input current
1.0
µA
VIH = VDD
IIL
Low-level logic input current
-1.0
µA
VIL = 0V
AC Characteristics (TA = 85°C max. Logic signal inputs and Data inputs have tr, tf ≤ 5ns [10% and 90% points])
Symbol
Parameter
fCLK
Clock frequency
Min
Max
0.001
25
0.001
Units
MHz
20
Conditions
VDD = 4.5V, TJ = 25°C
VDD = 4.5V, TJ = 125°C
tWL,tWH
Clock width high or low
20
ns
tSU
Data set-up time before clock rises
0
ns
tH
Data hold time after clock rises
15
ns
tON, tOFF
Time from latch enable to HVOUT
500
ns
CL = 15pF
tDHL
Delay time clock to data high to low
38
ns
CL = 15pF, VDD = 5.0V
tDLH
Delay time clock to data low to high
38
ns
CL = 15pF, VDD = 5.0V
tDLE*
Delay time clock to LE low to high
25
ns
tWLE
Width of LE pulse
25
ns
tSLE
LE set-up time before clock rises
0
ns
tr, tf
Output rise/fall time
1.0
µs
CL = 600pF,
HVOUT from 0 to 60V
* tDLE is not required but is recommended to produce stable HV outputs and thus minimize power dissipation and current spikes (allows internal SR output to stabilize).
Recommended Operating Conditions
Symbol
Parameter
Min
Max
Units
VDD
Logic supply voltage
4.5
5.5
V
VPP
Output voltage
12
80
V
VIH
High-level input voltage
VDD -0.5V
VIL
Low-level input voltage
0
0.5
V
fCLK
Clock frequency per register
0.001
25
MHz
TA
Operating free-air temperature
-40
+85
°C
Notes: Power-up sequence should be the following:
1. Connect ground.
2. Apply VDD.
3. Set all inputs (Data, CLK, Enable, etc.) to a known state.
4. Apply VPP.
5. The VPP should not drop below VDD or float during operation.
Power-down sequence should be the reverse of the above.
The VPP should not drop below VDD during operation.
2
V
HV574
Input and Output Equivalent Circuits
VDD
VDD
VPP
Data Out
Input
HVOUT
GND
GND
GND
Logic Data Output
Logic Inputs
High Voltage Outputs
Switching Waveforms
VIH
Data Input
50%
Data Valid
Data Valid
VIL
tSU
tH
VIH
Clock
50%
50%
50%
tWL
50%
tWH
VIL
VOH
50%
VOL
tDLH
Data Out
VOH
50%
VOL
tDHL
Latch Enable
VIH
50%
50%
VOL
tDLE
tWLE
tSLE
90%
10%
HVOUT
w/ S/R LOW
VOH
VOL
tf
tOFF
HVOUT
w/ S/R HIGH
90%
10%
tr
tON
3
VOH
VOL
HV574
Functional Block Diagram
VDD
LE
BL
DIR
DINA
DOUTA
POL
VPP
HVOUT1
20-bit
shift
register
HVOUT20
CLK
HVOUT21
DINB
DOUTB
20-bit
shift
register
HVOUT40
HVOUT41
DINC
DOUTC
20-bit
shift
register
HVOUT60
HVOUT61
DIND
DOUTD
20-bit
shift
register
HVOUT80
GND
4
HV574
Function Table
Inputs
Outputs
Function
Data
CLK
LE
BL
POL
DIR
Shift Reg
HV Outputs
All O/P High
X
X
X
L
L
X
H
All O/P Low
X
X
X
L
H
X
L
O/P Normal
X
X
X
H
H
X
No inversion
O/P Inverted
X
X
X
H
L
X
Inversion
L
↑
H
H
H
X
L
L
H
↑
H
H
H
X
H
H
Data Falls
Through
(Latches
Transparent)
L
↑
H
H
L
X
L
H
H
↑
H
H
L
X
H
L
X
X
L
H
H
X
*
Stored Data
X
X
L
H
L
X
*
Inversion of
Stored Data
DINX
↑
H
H
H
H
Qn→ Qn +1
New H or L
DOUTX
DINX
↑
L
H
H
H
Qn→ Qn +1
Previous
H or L
DOUTX
DOUTX
↑
L
H
H
L
Qn→ Qn -1
Previous
H or L
DINX
DOUTX
↑
H
H
H
L
Qn→ Qn -1
New H or L
DINX
Data Stored/
Latches Loaded
I/O Relation
Notes:
Data Out
* = dependent on previous stage’s state. See Pin configuration for DIN and DOUT pin designation for CW and CCW shift.
Pin Configuration
100-Pin PG Package
Pin Function
Pin
1
HVOUT30
26
2
HVOUT29
27
3
HVOUT28
28
4
HVOUT27
29
5
HVOUT26
30
6
HVOUT25
31
7
HVOUT24
32
8
HVOUT23
33
9
HVOUT22
34
10
HVOUT21
35
11
HVOUT20
36
12
HVOUT19
37
13
HVOUT18
38
14
HVOUT17
39
15
HVOUT 16
40
16
HVOUT15
41
17
HVOUT14
42
18
HVOUT13
43
19
HVOUT12
44
20
HVOUT11
45
21
HVOUT10
46
22
HVOUT9
47
23 HVOUT8
48
24 HVOUT7
49
25 HVOUT6
50
Function
HVOUT5
HVOUT4
HVOUT3
HVOUT2
HVOUT1
N/C
VPP
HVGND
DINA
DINB
DINC
DIND
VDD
POL
LE
CLK
DIR
BL
GND
DOUTD
DOUTC
DOUTB
DOUTA
HVGND
VPP
Package Outlines
Pin
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
Function
HVOUT80
HVOUT79
HVOUT78
HVOUT77
HVOUT76
HVOUT75
HVOUT74
HVOUT73
HVOUT72
HVOUT71
HVOUT70
HVOUT69
HVOUT68
HVOUT67
HVOUT66
HVOUT65
HVOUT64
HVOUT63
HVOUT62
HVOUT61
HVOUT60
HVOUT59
HVOUT58
HVOUT57
HVOUT56
Pin
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Function
HVOUT55
HVOUT54
HVOUT53
HVout52
HVOUT51
HVOUT50
HVOUT49
HVOUT48
HVOUT47
HVOUT46
HVOUT45
HVOUT44
HVOUT43
HVOUT42
HVOUT41
HVOUT40
HVOUT39
HVOUT38
HVOUT37
HVOUT36
HVOUT35
HVOUT34
HVOUT33
HVOUT32
HVOUT31
81
100
1
80
30
51
31
50
top view
100-Lead Plastic Quad Flat Package
("Gullwing" Package)
11/12/01
©2001 Supertex Inc. All rights reserved. Unauthorized use or reproduction prohibited.