TI PTD08A210WAC

PTD08A210W
www.ti.com
SLTS300 – SEPTEMBER 2010
SINGLE 10-A OUTPUT, 4.75-V to 14-V INPUT, NON-ISOLATED,
DIGITAL POWERTRAIN™ MODULE
Check for Samples: PTD08A210W
FEATURES
DESCRIPTION
•
•
•
The PTD08A210W is a high-performance single 10-A
output, non-isolated digital PowerTrain module. This
module is the power conversion section of a digital
power system which incorporates TI's UCD7242
MOSFET/driver IC. The PTD08A210W must be used
in conjunction with a digital power controller such as
the UCD9240, UCD9220 or UCD9110 family. The
PTD08A210W receives control signals from the
digital controller and provides parametric and status
information back to the digital controller. Together,
PowerTrain modules and a digital power controller
form a sophisticated, robust, and easily configured
power management solution.
1
2
•
•
•
•
•
Single 10-A Output
4.75-V to 14-V Input Voltage
Programmable Wide-Output Voltage
(0.7 V to 3.6 V)
Efficiencies up to 96%
Digital I/O
– PWM signal
– Fault Flag (FF)
– Sychronous Rectifier Enable (SRE)
Analog I/O
– Temperature
– Output currrent
Safety Agency Approvals:
– UL/IEC/CSA-C22.2 60950-1
Operating Temperature: –40°C to 85°C
APPLICATIONS
•
Digital Power Systems
using UCD9XXX Digital Controllers
Operating from an input voltage range of 4.75 V to
14 V, the PTD08A210W provides step-down power
conversion to a wide range of output voltages from,
0.7 V to 3.6 V. The wide input voltage range makes
the PTD08A210W particularly suitable for advanced
computing and server applications that utilize a
loosely regulated 8-V, 9.6-V or 12-V intermediate
distribution bus. Additionally, the wide input voltage
range increases design flexibility by supporting
operation with tightly regulated 5-V or 12-V
intermediate bus architectures.
The module incorporates output over-current and
temperature monitoring which protects against most
load faults. Output current and module temperature
signals are provided for the digital controller to permit
user defined over-current and over-temperature
warning and fault scerarios.
The module uses single-sided, pin-less surface
mount construction to provide a low profile and
compact footprint. The package is lead (Pb) - free
and RoHS compatible.
1
2
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
POWERTRAIN is a trademark of Texas Instruments.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2010, Texas Instruments Incorporated
PTD08A210W
SLTS300 – SEPTEMBER 2010
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
Standard PTD08A210W Application
Digital Lines
to/from
Digital Controller
VI
4
5
6
PWM
SRE
FF
VOUT
1
VIN
VOUT 16
2
VIN
VOUT 15
PTD08A210W
PGND 14
+
PGND 13
CIN1
330 mF
(Recommended)
CIN2
22 mF
(Required)
PGND
3
TSENSE ISENSE
12
11
CO1
+
47 mF
(Required)
CO2
330 mF
(Recommended)
AGND AGND PGND PGND
10
9
8
7
GND
GND
Analog
Lines
to
Digital
Controller
UDG-10063
2
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
PTD08A210W
www.ti.com
SLTS300 – SEPTEMBER 2010
ORDERING INFORMATION
For the most current package and ordering information, see the Package Option Addendum at the end of this datasheet, or see
the TI website at www.ti.com.
DATASHEET TABLE OF CONTENTS
DATASHEET SECTION
PAGE NUMBER
ENVIRONMENTAL AND ABSOLUTE MAXIMUM RATINGS
3
ELECTRICAL CHARACTERISTICS TABLE
4
TERMINAL FUNCTIONS
5
TYPICAL CHARACTERISTICS (VI = 12V)
6
TYPICAL CHARACTERISTICS (VI = 5V)
7
TYPICAL APPLICATION SCHEMATIC
9
GRAPHICAL USER INTERFACE VALUES
10
TAPE & REEL AND TRAY DRAWINGS
11
ENVIRONMENTAL AND ABSOLUTE MAXIMUM RATINGS
(Voltages are with respect to GND)
UNIT
VI
Input voltage
TA
Operating temperature range
Over VI range
16
Treflow
Solder reflow temperature
Surface temperature of module body
Tstg
Storage temperature
260 (1)
(1)
°C
–55 to 125
Mechanical shock
Per Mil-STD-883D, Method 2002.3, 1 msec, 1/2 sine, mounted
275
Mechanical vibration
Mil-STD-883D, Method 2007.2, 20-2000 Hz
10
Weight
MTBF
V
–40 to 85
Reliability
Per Telcordia SR-332, 50% stress, TA = 40°C, ground benign
Flammability
Meets UL94V-O
G
3.9
grams
13.3
106 Hr
During reflow do not elevate peak temperature of the module or internal components above the stated maximum.
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
3
PTD08A210W
SLTS300 – SEPTEMBER 2010
www.ti.com
ELECTRICAL CHARACTERISTICS
PTD08A210W
TA= 25°C, FSW= 750kHz, VI= 12 V, VO= 1.2 V, CIN1= 330 µF, CIN2= 22 µF ceramic, CO1= 47 µF ceramic, CO2= 330 µF, IO=
IO(max) (unless otherwise stated)
PARAMETER
TEST CONDITIONS
PTD08A210W
MIN
IO
Output current
Over VO range
VI
Input voltage range
VOADJ
Output voltage adjust range
Efficiency
h
25°C, natural convection
10
A
Over IO range
4.75
14
V
Over IO range
0.7
3.6 (1)
V
IO = 10 A,
fs = 750 kHz
VO Ripple (peak-to-peak)
20-MHz bandwidth
IB
Bias current
PWM & SRE to AGND
VIH
High-level input voltage
VIL
Low-level input voltage
VO = 3.3 V
92.0%
VO = 2.5 V
90.4%
VO = 1.8 V
88.4%
VO = 1.2 V
84.7%
VO = 0.8 V
80.0%
11
Standby
SRE & PWM input levels
VOL
0.8
Frequency range
500
Pulse width limits
ILIM
-5
2.7
720
mV
3.3
0
0.15
Gain, 3A ≤ IO ≤ 10A
188
0
Offset, IO = 0A, VO = 1.2V
CO
External output capacitance
Ceramic
Equivalent series resistance (non-ceramic)
(1)
(2)
(3)
(4)
(5)
(6)
4
22
(3)
47
(4)
Nonceramic
Ceramic
1 (6)
V
A
3.5
V
200
212
mV/A
0.3
0.6
10
Nonceramic
Capacitance Value
0.6
15 (2)
Range
°C
mV/°C
Low-level output voltage, IFAULT = 4mA
External input capacitance
°C
10
Output Impedance
CI
125
5
Slope
Overcurrent threshold; Reset, followed by auto-recovery
IOUT output
kHz
ns
-40
Accuracy, -40°C ≤ TA ≤ 85°C
V
1000
20
High-level output voltage, IFAULT = 4mA
FAULT output
mA
5.5
(1)
Offset, TA = 25°C
VOH
mVPP
6
2.0
Range
TEMP output
MAX
0
VOPP
PWM input
TYP
UNIT
330
(3)
330
(4)
V
kΩ
µF
5000 (5)
µF
mΩ
When operating at 12V input and 500kHz, VO is limited to ≤ 2.0V.
The current limit threshold is the sum of IO and the peak inductor ripple current.
A 22 µF ceramic input capacitor is required for proper operation. An additional 330 µF bulk capacitor rated for a minimum of 500mA rms
of ripple current is recommended. When operating at frequencies > 500kHz the 22 µF ceramic capacitor is only recommended. Refer to
the UCD9240 controller datasheet and user interface for application specific capacitor specifications.
A 47 µF ceramic output capacitor is required for basic operation. An additional 330 µF bulk capacitor is recommended for improved
transient response. Refer to the UCD9240 controller datasheet and user interface for application specific capacitor specifications.
5,000 µF is the calculated maximum output capacitance given a 1V/msec output voltage rise time. Additional capacitance or increasing
the output voltage rise rate may trigger the overcurrent threshold at start-up. Refer to the UCD9240 controller datasheet and user
interface for application specific capacitor specifications.
This is the minimum ESR for all non-ceramic output capacitance. Refer to the UCD9240 controller datasheet and user interface for
application specific capacitor specifications.
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
PTD08A210W
www.ti.com
SLTS300 – SEPTEMBER 2010
TERMINAL FUNCTIONS
TERMINAL
NAME
VIN
PGND
NO.
1, 2
DESCRIPTION
The positive input voltage power node to the module, which is referenced to common GND.
3, 7, 8, 13,
The common ground connection for the VI and VO power connections.
14
VOUT
15, 16
ISENSE
11
Current sense output. The voltage level on this pin represents the average output current of the module.
PWM
4
The PWM input pin. It is a high impedance digital input that accepts 3.3-V or 5-V logic level signals up to 1 MHz.
FF
6
Current limit fault flag. The Fault signal is a 3.3-V digital output which is latched high after an over-current condition.
The Fault is reset after a complete PWM cycle without an over-current condition (falling edge of the PWM).
SRE
5
Synchronous Rectifier Enable. This pin is a high impedance digital input. A 3.3 V or 5 V logic level signals is used
to enable the synchronous rectifier switch. When this signal is high, the module will source and sink output current.
When this signal is low, the module will only source current.
AGND
9, 10
TSENSE
12
Thermal
Pad
The regulated positive power output with respect to GND.
Analog ground return. It is the 0 Vdc reference for the control inputs.
Temperature sense output. The voltage level on this pin represents the temperature of the module.
This pad is electrically connected to PGND and is the primary thermal conduction cooling path for the module. This
pad should be soldered to a grounded copper pad on the host board. For optimum cooling performance, the
grounded copper pad should also be tied with multiple vias to the host board internal ground plane. See the Land
Pattern drawing for package ECY for recommended pad dimensions.
1
1
XX
XX
16
VOUT
16
2
15
VOUT
15
PGND
3
14
PGND
14
PWM
4
13
PGND
13
4
SRE
5
12
TSENSE
12
5
FF
6
11
ISENSE
11
6
PGND
7
10
AGND
10
7
PGND
8
9
AGND
9
8
VIN
VIN
TOP VIEW
2
Thermal Pad
3
BOTTOM VIEW
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
5
PTD08A210W
SLTS300 – SEPTEMBER 2010
www.ti.com
TYPICAL CHARACTERISTICS (VI = 12 V)
. (1) (2)
100
100
VIN =12 V
fSW =500 kHZ
100
VIN =12 V
fSW =750 kHZ
95
90
85
85
75
70
Efficiency (%)
90
85
80
80
75
70
65
65
60
55
55
50
2
4
6
8
10
2
Output Current (A)
4
6
8
10
0
1.5
1
1
0.5
2
4
6
8
10
1
0.5
VIN =12 V
fSW =750 kHZ
0
2
4
6
8
10
0
Figure 5. Power Dissipation
80
60
50
40
VIN =12 V
fSW = 500 kHz
VOUT < 2.0 V
Natural Convection
60
50
40
VIN =12 V
fSW = 750 kHz
All VOUTValues
30
20
TA – Ambient Temerature – °C
80
TA – Ambient Temerature – °C
80
70
2
4
6
8
10
8
10
Natural Convection
70
60
50
40
VIN =12 V
fSW = 1 MHz
All VOUTValues
30
20
0
6
Figure 6. Power Dissipation
90
Natural Convection
4
Output Current (A)
90
30
2
Output Current (A)
90
70
VIN =12 V
fSW =1 MHZ
0
Output Current (A)
Figure 4. Power Dissipation
10
1.5
0
2
8
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
2.5
1.5
0
6
3
2
VIN =12 V
fSW =500 kHZ
4
Output Current (A)
Power Dissipation (W)
2
0
2
Figure 3. Efficiency
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
2.5
Power Dissipation (W)
Power Dissipation (W)
55
3
0.5
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
60
Output Current (A)
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
2.5
TA – Ambient Temerature – °C
65
Figure 2. Efficiency
3
6
70
50
0
Figure 1. Efficiency
(2)
75
50
0
(1)
80
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
60
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
VIN =12 V
fSW =1 MHZ
95
90
Efficiency (%)
Efficiency (%)
95
20
0
2
4
6
8
10
0
2
4
6
8
IOUT – Output Current – A
IOUT – Output Current – A
IOUT – Output Current – A
Figure 7. Safe Operating Area
Figure 8. Safe Operating Area
Figure 9. Safe Operating Area
10
The electrical characteristic data (Figure 1 through Figure 6) has been developed from actual products tested at 25°C. This data is
considered typical for the converter.
The temperature derating curves (Figure 7 through Figure 9) represent the conditions at which internal components are at or below the
manufacturer's maximum operating temperatures. Derating limits apply to modules soldered directly to a 100-mm x 100-mm,
double-sided PCB with 2-oz. copper. See the Safe Operating Area application section of this datasheet.
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
PTD08A210W
www.ti.com
SLTS300 – SEPTEMBER 2010
100
100
95
95
95
90
90
90
85
85
85
80
75
70
65
VIN =5 V
fSW =500 kHZ
55
80
75
70
65
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
60
Efficiency (%)
100
Efficiency (%)
60
VIN =5 V
fSW =750 kHZ
55
50
2
4
6
8
10
2
Output Current (A)
8
10
0
1.5
1
4
6
8
1
0.5
10
2
1
0.5
2
4
6
8
10
TA – Ambient Temerature – °C
Natural Convection
60
50
40
VIN = 5 V
fSW = 500 kHz
All VOUT Values
90
80
80
Natural Convection
70
6
8
10
4
6
8
10
Figure 15. Power Dissipation
60
50
40
VIN = 5 V
fSW = 750 MHz
All VOUTValues
Natural Convection
70
60
50
40
VIN = 5 V
fSW = 1 MHz
All VOUTValues
30
20
4
2
Output Current (A)
90
30
20
2
0
Figure 14. Power Dissipation
100 LFM
30
VIN =5 V
fSW =1 MHZ
Output Current (A)
80
10
0
0
90
8
1.5
VIN =5 V
fSW =750 kHZ
Output Current (A)
Figure 13. Power Dissipation
6
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
2.5
0
2
4
Output Current (A)
1.5
VIN =5 V
fSW =500 kHZ
0
2
Figure 12. Efficiency
Power Dissipation (W)
Power Dissipation (W)
Power Dissipation (W)
6
3
2
0
TA – Ambient Temerature – °C
4
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
2.5
0.5
VIN =5 V
fSW =1 MHZ
55
3
2
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
60
Output Current (A)
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
2.5
(2)
65
Figure 11. Efficiency
3
(1)
70
50
0
Figure 10. Efficiency
0
75
50
0
70
80
VOUT=3.3 V
VOUT=2.5 V
VOUT=1.8 V
VOUT=1.2 V
VOUT=0.8 V
TA – Ambient Temerature – °C
Efficiency (%)
TYPICAL CHARACTERISTICS (VI = 5 V)
. (1) (2)
20
0
2
4
6
8
10
0
2
4
6
8
IOUT – Output Current – A
IOUT – Output Current – A
IOUT – Output Current – A
Figure 16. Safe Operating Area
Figure 17. Safe Operating Area
Figure 18. Safe Operating Area
10
The electrical characteristic data (Figure 10 through Figure 15) has been developed from actual products tested at 25°C. This data is
considered typical for the converter.
The temperature derating curves (Figure 16 through Figure 18) represent the conditions at which internal components are at or below
the manufacturer's maximum operating temperatures. Derating limits apply to modules soldered directly to a 100-mm x 100-mm,
double-sided PCB with 2-oz. copper. See the Safe Operating Area application section of this datasheet.
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
7
PTD08A210W
SLTS300 – SEPTEMBER 2010
www.ti.com
TYPICAL CHARACTERISTICS
CURRENT SENSE OUTPUT
vs
OUTPUT CURRENT
CURRENT SENSE OUTPUT
vs
OUTPUT CURRENT
1.2
1.0
0.8
0.6
0.4
0.2
VTSENSE – Temperature Sense Output Voltage – V
1.6
1.4
0
VI = 5 V
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0
8
2.0
2.0
VI = 12 V
1.8
VISENSE – Current Sense Output Voltage – V
VISENSE – Current Sense Output Voltage – V
2.0
TEMPERATURE SENSE
vs
JUNCTION TEMPERATURE
2
4
6
8
10
0
2
4
6
8
10
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
–50
–25
0
25
50
75
100
IO – Output Current – A
IO – Output Current – A
TJ – Junction Temperature – °C
Figure 19.
Figure 20.
Figure 21.
Submit Documentation Feedback
125
150
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
PTD08A210W
www.ti.com
SLTS300 – SEPTEMBER 2010
APPLICATION INFORMATION
Digital Power
Figure 22 shows the UCD9220 power supply controller working with a single PTD08A210W, digital powertrain
module. The loop for the power supply is created by the voltage output feeding into the Error ADC differential
inputs, and completed by the DPWM output feeding the PTD08A210W module. A second stand-alone power
stage can be controlled by the UCD9220 controller. The PTD08A210W's output cannot be paralleled. It can only
be used as a single stand-alone 10-A module.
VIN
35
33
34
V33A
BPCap
Vin/Iin
V33FB
4
V33D
41
+3.3 V
+3.3 V
FLT-1A
DPWM-1A
SRE-1A
CS-1A
24
26
27
28
29
30
31
43
44
45
FAULT-2A
GPIO-1
DPWM-2A
GPIO-2
UCD9220
SRE-2A
TMUX-0
CS-2A
PowerGood
FAULT-3A
TCK
DPWM-3A
SRE-3A
TDO/SYNC-OUT
TDI/SYNC-IN
CS-3A
TMS
Temp
VIN
VIN
3
PGND
VOUT 16
6
FF
VOUT 15
9
4
PWM
42
5
SRE
7
11
6
12
PTD08A210W
18
PGND 14
2
PGND 13
8
14
15
3
VOUT
ISENSE
13
To 2nd
Power
Stage
PGND
8
PGND
7
TSENSE
AGND AGND
TMUX-1
25
16
9
10
12
17
1
46
37
TRST
EAP1
ADDR-0
ADDR-1
Vtrack
ADCref
36
48
PMBus-CNTL
PowerPad
22
23
CS-1B
PMBus-Alert
2
EAN1
38
EAP2
39
To 2nd Power Stage
EAN2
40
49
21
PMBus-Data
DGND1
20
SRE-1B
AGND2
19
DPWM-1B
PMBus-CLK
32
11
47
10
FAULT-1B
RESET
AGND1
5
1
UDG-10064
Figure 22. Typical Dual-Output Application Schematic
Note: A low dropout linear regulator such as the TI TPS715A33 can provide the 3.3-V bias power to the UCD9220.
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
9
PTD08A210W
SLTS300 – SEPTEMBER 2010
www.ti.com
Fusion Digital Power Graphical User Interface (GUI)
When using the UCD92x0 digital controller along with digital PowerTrain modules to design a digital power
system, several internal parameters of the modules are required to run the Fusion Digital Power Designer GUI.
See the plant parameters below for the PTD08A210W digital PowerTrain modules.
Table 1. PTD08A210W Plant Parameters
PTD08A210W Plant Parameters
L (µH)
DCR (mΩ)
RDS(on)-high (mΩ)
RDS(on)-low (mΩ)
0.47
2.6
15.5
6.5
Internal output capacitance is present on the digital PowerTrain modules themselves. When using the GUI
interface this capacitance information must be included along with any additional external capacitance. See the
capacitor parameters below for the PTD08A210W digital PowerTrain modules.
Table 2. PTD08A210W Capacitor Parameters
PTD08A210W Capacitor Parameters
10
C (µF)
ESR (mΩ)
ESL (nH)
Quantity
47
1.5
2.5
1
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
PTD08A210W
www.ti.com
SLTS300 – SEPTEMBER 2010
TAPE & REEL
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
11
PTD08A210W
SLTS300 – SEPTEMBER 2010
www.ti.com
TRAY
12
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): PTD08A210W
PACKAGE OPTION ADDENDUM
www.ti.com
1-Oct-2010
PACKAGING INFORMATION
Orderable Device
PTD08A210WAC
PTD08A210WACT
Status
(1)
ACTIVE
Package Type Package
Drawing
Pins
Package Qty
Eco Plan
(2)
Lead/
Ball Finish
MSL Peak Temp
(3)
Samples
(Requires Login)
DIP MODULE
ECY
16
42
TBD
Call TI
Call TI
Purchase Samples
PREVIEW DIP MODULE
ECY
16
250
TBD
Call TI
Call TI
Samples Not Available
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DLP® Products
www.dlp.com
Communications and
Telecom
www.ti.com/communications
DSP
dsp.ti.com
Computers and
Peripherals
www.ti.com/computers
Clocks and Timers
www.ti.com/clocks
Consumer Electronics
www.ti.com/consumer-apps
Interface
interface.ti.com
Energy
www.ti.com/energy
Logic
logic.ti.com
Industrial
www.ti.com/industrial
Power Mgmt
power.ti.com
Medical
www.ti.com/medical
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
RFID
www.ti-rfid.com
Space, Avionics &
Defense
www.ti.com/space-avionics-defense
RF/IF and ZigBee® Solutions www.ti.com/lprf
Video and Imaging
www.ti.com/video
Wireless
www.ti.com/wireless-apps
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2010, Texas Instruments Incorporated