ANALOGICTECH TFS942

TFS942.doc
version 1.2
VI TELEFILTER
19.11.2003
Development Specification
TFS 942
1/5
Measurement condition
25 ± 2
0
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
°C
dBm
50
50
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 942,5 MHz without any tolerance or
limit. The electrical data have to be guaranteed at ambient temperature.
Data
typ. value
Insertion loss
Nominal frequency
Passband
Ae
-
fN
-
PB
-
Pass band ripple (p-p)
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
dB
942,5
MHz
fN
max.
± 17,5
1,7
MHz
dB
min.
min.
min.
min.
min.
min.
min.
min.
min.
40
35
22
20
14
18
30
40
15
...
...
...
...
...
...
...
...
...
860
880
905
915
980
1005
1050
1500
3000
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Operable temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
Input power level
*)
3,4
Aabs
Absolute attenuation
0
860
880
905
970,7
980
1005
1050
1500
tolerance / limit
max.
TCf *
-
- 20 °C ... + 75 °C
-
- 40 °C ... + 85 °C
-30
-
ppm/K
dB
dB
dB
dB
dB
dB
dB
dB
dB
max.
15
dBm
fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated
:
Checked / approved
:
TELE FILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS942.doc
version 1.2
VI TELEFILTER
19.11.2003
Development Specification
TFS 942
2/5
Construction and pin configuration
(All dimensions in mm)
942
R42
R39
date code
Date code: Year+week
N
P
R
Pin
Pin
Pin
Pin
Pin
Pin
2001
2002
2003
...
1
2
3
4
5
6
Input Ground
Input
Ground
Output Ground
Output
Ground
TELE FILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS942.doc
version 1.2
VI TELEFILTER
19.11.2003
Development Specification
TFS 942
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
9000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Tape (all dimensions in mm)
W
Po
Do
E
F
G (min)
P2
P1
D1(min)
Ao
Bo
CT
:
:
:
:
:
:
:
:
:
:
:
:
8
4
1,5
1,75
3,5 ±
0,75
2
4
1,5
3,25
3,25
5,5
Do
± 0,3
± 0,1
+ 0,1
± 0,1
0,05
Po
P2
E
Ao
F
D1
CT
W
Bo
± 0,05
± 0,1
G
± 0,1
± 0,1
± 0,2
P1
COVER TAPE
W2
Reel (all dimensions in mm):
A
W1
:
330
:
8,4 + 2,0
W2 (m ax) :
14,4
N (m in)
:
C
:
50
13
A
+0,5/ -0,2
C
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
TELE FILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS942.doc
version 1.2
VI TELEFILTER
19.11.2003
Development Specification
TFS 942
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods main-heating periods
150 °C - 170 °C
over 200 °C
60 sec. - 90 sec.
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / s ec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
TELE FILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS942.doc
version 1.2
VI TELEFILTER
Development Specification
19.11.2003
TFS 942
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Roizengaft
16.10.2003
1.1
- Definition of packing
Roizengaft
30.10.2003
1.2
-
Wall
19.11.2003
Change operating temperature range to operable temperature range
Change remark for electrical data
Change ambient temperature
Add value for temperature coefficient of frequency
TELE FILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.