tfs208L.doc Version 2.0 VI TELEFILTER Filter Specification 03.06.2003 TFS 208L 1/5 Measurement condition Ambient temperature: 23 C Input power level: 0 dBm Terminating impedance’s : 50 Characteristics Remark: Reference level for the relative attenuation arel of the TFS 208L is the maximum attenuation in the pass band. The maximum attenuation in the pass band is defined as the insertion loss a e. The nominal frequency fN is fixed at 208 MHz without tolerance or limit. The values of relative attenuation a rel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss ae 2,20 Nominal frequency fN - 1 dB band width BW dB tolerance / limit 2,5 1,0 dB (Reference level) 100 Amplitude ripple within fN Relative attenuation arel fN 400 kHz fN fN fN fN + fN + 14 23 33 14 28 MHz... fN MHz... fN MHz... fN MHz... fN + MHz... fN + 23 33 207 28 242 400 kHz Absolute group delay GD*) 400 kHz ... fN + GDR *) fN - 400 kHz 400 kHz ... fN + Intermodulation MHz min. 800 0,05 dB max. 0,20 dB max. 1 dB min. min. min. min. min. 30 44 38 5 12 dB dB dB dB dB 60 52 60 38 51 dB dB dB dB dB 1,5:1 400 kHz Group delay ripple MHz 4,95 - MHz MHz MHz MHz MHz VSWR fN - 400 kHz ... fN + fN - kHz 208 max kHz 2:1 170 ns max. 300 ns 12 ns max. 100 ns 54 dB min. max dB dBm **) IP3 Input power level Temperature coefficient of frequency TCf ***) Operating temperature range - 33 ppm/K - Storage temperature range *) measured with smoothing; smoothing aperture 50 kHz **) modulation signals: fN and fN + 14 MHz, each of 10 dBm; measured signal: ***) f(Hz) = TCf(ppm/K) x ( T) x fTo(MHz) 45 10 - - 10 °C ... + 85 °C - 30°C ... + 85 C fN - 14 MHz generated: checked / approved: TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs208L.doc Version 2.0 VI TELEFILTER Filter Specification 03.06.2003 TFS 208L 2/5 Construction and pin connection (All dimensions in mm) 9,3 Max. 8 7 6 9 5 TFS 208L 4 10 1 2 3 Date code 2,54 ±0,12,54 ±0,1 0,10 2 3 1 4 10 9 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Ground Output Ground Ground Ground Ground Input Date code: Year+week N P R 2001 2002 2003 ... 5 8 7 0,8 7,1 6 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs208L.doc Version 2.0 VI TELEFILTER Filter Specification 03.06.2003 TFS 208L 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) EMBOSSED CARRIER TAPE W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : 7,5 ± 0,1 G (min) : P2 : P1 Do Po P2 E Ao F D1 0,6 CT 2 ± 0,1 ± 0,1 : 8 D1(min) : 1,5 Ao : 5,3 ± 0,1 Bo : 9,7 ± 0,1 CT : W Bo G P1 COVER TAPE 13,5 + 0,1 W 2 Reel (all dimensions in mm): A W1 : : 330 16,4 +2 W2 (max) : 22,4 N (min) : 50 C : C 13 + 0,5 / - 0,2 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs208L.doc Version 2.0 VI TELEFILTER Filter Specification 03.06.2003 TFS 208L 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs208L.doc Version 2.0 VI TELEFILTER Filter Specification 03.06.2003 TFS 208L 5/5 History Version Reason of Changes Name Date 1.0 - generation of development specification according to the customer specification (V-1.0.0; 15 Jan 03) Dr. Sabah 07.03.03 - updated according to customer specification, version 2.0 (20th may 2003) - add of typical values and generation of filter specification Dr. Sabah 03.06.03 1.1 2.0 Missing TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.