CHINFA EDA60-24

EDA60 SERIES
AC-DC ENCLOSED SWITCHING POWER SUPPLY
FEATURES
‧UL / cUL / TUV / CE
‧COMPLY WITH ErP (except 5V model)
‧UNIVERSAL INPUT 88~264VAC
‧SHORT CIRCUIT PROTECTION
‧INTERNAL INPUT FILTER
‧2 YEARS WARRANTY
‧HIGH EFFICIENCY UP TO 89%
‧HIGH AVERAGE EFFICIENCY
‧LOW STANDBY POWER CONSUMPTION
R
H
a
UL 60950-1
EN 60950-1
MODEL LIST
MODEL NO.
INPUT
VOLTAGE
OUTPUT
WATTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFF.
(min.)
EFF.
(typ.)
EFF.
(avg.)
Single Output Models
EDA60-05
88~264 VAC
45 WATTS
+ 5 VDC
9000 mA
80%
82%
81%
EDA60-12
88~264 VAC
60 WATTS
+ 12 VDC
5000 mA
86%
88%
87%
EDA60-15
88~264 VAC
60 WATTS
+ 15 VDC
4000 mA
87%
89%
87%
EDA60-24
88~264 VAC
60 WATTS
+ 24 VDC
2500 mA
87%
89%
87%
SPECIFICATION
o
All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed
GENERAL
Conditions
Conditions
Characteristics
min.
min.
typ.
typ.
max.
max.
unit
unit
Switching frequency
Vi nom, Io nom
Isolation voltage
Input-Output
3000 / 4242
VAC / VDC
Input-FG
1500 / 2121
VAC / VDC
100
MΩ
40
Isolation resistance
Input-Output, @ 500VDC
Ambient temperature *1
Operating at Vi nom
o
Vi nom, from 61 C to +71 C
Storage temperature
Non operational
-40
Relative humidity
Vi nom, Io nom
20
Temperature coefficient
Vi nom, Io min
MTBF
Bellcore Issue 6 @40 oC, GB
Cooling
2.5
+ 85
o
C
% / oC
o
C
95
% RH
± 0.03
% / oC
5V model
570000
Hours
12V model
588000
Hours
15V model
602000
Hours
24V model
615000
Hours
IEC 60068-2-13
Dimension
KHz
+ 71
-40
o
Derating (see derating curve)
Altitude during operation
100
4850
L98 x W82 x D35
m
mm
Free air convection
*1. It is permissible to be lower than -25oC , but minimum load is 2%
www.chinfa.com
2010.05.25
[email protected]
P1
EDA60 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
INPUT SPECIFICATIONS
Characteristics
Rated input voltage
Conditions
Io nom
Absolute input max. range
Input current
Vi : 115 / 230 VAC, Io nom
Rated input current
Vi : 88 VAC, Io nom
Line frequency
Vi nom, Io nom
Inrush current
Power dissipation
Vi : 115 / 230 VAC , Io nom
Leakage current
min.
typ.
unit
VAC
100
240
AC in
88
264
VAC
DC in
120
375
VDC
1100 / 600
47
Vi : 230 VAC, Io nom
mA
1500
mA
63
30 / 60
Hz
A
5V model
11
W
12V model
15V model
10
W
9
W
24V model
8
W
Input-Output
Input-FG
Standby power consumption
max.
Vi nom, Io=0A
0.25
mA
3.5
0.5
mA
max.
unit
+1
%
W
OUTPUT SPECIFICATIONS
Characteristics
Conditions
min.
Output voltage accuracy
(Adjusted before shipment)
Vi nom, Io max
0
Minimum load
Line regulation
Vi nom
Io nom, Vi min ...Vi max
0
Load regulation
Vi nom, Io min ...Io nom
Voltage trim range
Vi nom,
0.8 Io nom
Rated continuous loading
Vi nom
typ.
%
± 0.5
%
VDC
%
5V model
4.75
±1
5.5
12V model
15V model
10.8
13.2
VDC
13.5
16.5
VDC
24V model
5V model
27.6
21.6
9 A @ 5Vdc / 8.1 A @ 5.5 Vdc
12V model
15V model
24V model
VDC
5 A @ 12Vdc / 4.5 A @ 13.2 Vdc
4 A @ 15Vdc / 3.6 A @ 16.5 Vdc
2.5 A @ 24Vdc / 2.15 A @ 27.6 Vdc
Hold up time
Vi : 115 / 230 VAC , Io nom
Turn on time
Vi nom, Io nom
5V, 12V & 15V models
24V model
1500
ms
ms
2000
ms
Vi nom, Io nom
5V, 12V &15V models : with 7000μF CAP
24V model : with 3500μF CAP
2000
ms
2500
ms
150
ms
500
ms
150
ms
Rise time
10 / 80
Vi nom, Io nom
Vi nom, Io nom
5V, 12V &15V models : with 7000μF CAP
24V model : with 3500μF CAP
Fall time
Transient recovery time
Vi nom, Io nom
Ripple & noise
Vi nom, Io nom, BW = 20MHz
Power back immunity
Vi nom, Io nom
1 second
2
ms
100
mV
Vi nom, 1~0.5 Io nom
5V model
7.5
VDC
12V model
15V model
18
VDC
22
35
VDC
24V model
5V, 12V &15V models
Capacitor load
Vi nom, Io nom
Efficiency
Vi nom, Io nom, Po / Pi
24V model
7000
VDC
μF
μF
3500
Up to 89%, See model list and typ efficiency curve
CONTROL AND PROTECTION
Characteristics
Conditions
min.
Input fuse
Internal surge voltage protection
Rated over load protection
www.chinfa.com
2010.05.25
typ.
max.
unit
T2A / 250VAC internal
IEC 61000-4-5
Vi nom (see typ current limited curve)
Varistor
110
150
%
[email protected]
P2
EDA60 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
CONTROL AND PROTECTION
Characteristics
Over voltage protection
typ.
min.
max.
unit
5V model
5.75
6.75
VDC
12V model
13.8
16.2
VDC
15V model
17.25
20.25
VDC
24V model
28.8
32.4
VDC
Conditions
Vi nom, Io nom (Auto Recovery)
Output short circuit
Hiccup mode
APPROVALS AND STANDARDS
UL / cUL
UL 60950-1 Recognized
TUV
EN 60950-1, CB scheme
CE
EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 55024
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8
EN 61000-4-11, ENV 50204, EN 61204-3
Vibration resistance
meet IEC 60068-2-6 (10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis )
Shock resistance
meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face)
PHYSICAL CHARACTERISTICS
Case size
98 x 82 x 35 mm (3.86 x 3.23 x 1.38 inches)
Case material
Metal
Weight
310 g
MECHANISM & PIN CONFIGURATION
mm [inch]
55.00 [2.17]
8.20 [0.32] 9.50 [0.37]
19.50 [0.77]
INSTALLATION
Ventilation / Cooling
Normal convection
Connector size range
AWG22-14 (0.2~2mm2 ) flexible / solid cable,
connector can withstand torque at maximum
12 pound-inches.
2-M3 L=Max 4mm
Vout ADJ.
4.00 [0.16]
98.00 [3.86]
5.50 [0.22]
82.00 [3.23]
GENERAL TOLERANCE
0.00[0.00] - 30.00[1.18]
±0.30[0.01]
30.00[1.18] - 120.00[4.72]
±0.50[0.02]
5.00 [0.20]
88.5 [3.48]
40.00 [1.57]
40.5 [1.59]
4.40
82.00 [3.23]
87.00 [3.43]
17.00 [0.67]
www.chinfa.com
2010.05.25
35.00 [1.38]
2-M3 L=Max 8mm
17.50 [0.69]
3.5
35.00 [1.38]
3.5
28.00 [1.10]
1
L
2
(AC)
N
3
4
5
V +V
+V
Vout AD
74.00 [2.91]
[email protected]
P3
EDA60 SERIES
PIN ASSIGNMENT
Designation
PIN NO.
Input terminals (phase conductor, no polarity at DC input)
Input terminals (neutral conductor, no polarity at DC input)
IN
2
N
V -
Negative output terminal
V+
Vout ADJ.
Positive output terminal
DC ON
Operation indicator LED
Ground this terminal to minimize high-frequency emissions
3
4
5
Description
L
OTHER OUT
1
Trimmer-potentiometer for Vout adjustment
CIRCUIT SCHEMATIC
‧Block diagram for EDA60 series
L
Fuse
Vo +
Rectifier
Line
Filter
Inrush Current
Switching
Limiter and
Device
Rectifier
Vo -
N
Y
Control
Circuit
FG
Opto Isolation
Reference &
Error Amp.
Vout ADJ.
TYP. CURRENT LIMITED CURVE
Output Voltage [ % ]
v
EDA60
Hiccup mode
100
50
t
Time
DERATING CURVE
TYP. EFFICIENCY CURVE
EDA60-24
90
88
EFFICIENCY [ % ]
Power out [ % ]
100
75
0
-40
o
61
Temperature [ C ]
www.chinfa.com
2010.05.25
71
86
84
82
80
10
230 Vac
115 Vac
25
50
Power out [ % ]
75
100
[email protected]
P4