SMALL FLANGE REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER FKX...4 DATA SHEET The FCX–A2 small flange remote seal type differential pressure transmitter accurately measures differential pressure, liquid level or gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with stateof-the-art microprocessor technology to provide exceptional performance and functionality. Totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions. FEATURES 1. Directly connectable to 1-1/2 in and 2in flanges The transmitter is connectable to 1-1/2 in and 2in pipes without a reducer. 2. Flow measurement without impulse piping 1/2 in and 3/4 in flange size is also available. This differential pressure transmitter allows connection to 1/2 in and 3/4 in flanges of a general size for the orifice tap, which eliminates the need of using a impulse piping. Problems with the impulse piping, such as clogging, leaks or corrosion can be solved. In addition, the following process connection is also available. Screw connection 1/2-14NPT, 3/4-14NPT, Rc 1/2, Rc 3/4 3. Minimum environmental influence The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 4. Fuji/HART® bilingual communications protocol and FOUNDATION™ fieldbus and Profibus™ compatibility FCX–A2 series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX–A2. Further, by upgrading electronics FOUNDATION™ fieldbus and Profibus™ are also available. 5. Application flexibility Various options that render the FCX–A2 suitable for almost any process applications include: – Analog indicator at either the electronics side or terminal side – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5 -digit LCD meter with engineering unit – Stainless steel electronics housing – Wide selection of materials – High temperature, high vacuum seals 6. Programmable output Linearization Function In addition to Linear and Square Root, output signal can be freely programmable. (Up to 14 compensated points at approximation.) 7. Burnout current flexibility (Under Scale: 3.2 to 3.8mA, Over Scale: 20.8 to 21.6mA) Burnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 9. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. SPECIFICATIONS Functional specifications Service: Liquid, gas, or vapour Static pressure, span, and range limit: Type Static pressure Span limit [kPa] (m bar} Min. F KX 3 F KX 5 F KX 6 Up to flange rating 3 { 30} 13 {130} 50 {500} Max. Range limit [kPa] {m bar} 32 { 320 } 130 {1300 } 500 {5000 } +/– 32 {+/– 320} +/– 130 {+/– 1300} +/– 500 {+/– 5000} – Maximum static pressure limit for screw connction type: 4.2MPa – Lower limit of static pressure (vacuum limit), Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: Atmospheric pressure – The maximum span of each sensor can be converted to different units using factors as below. 1MPa =103kPa=10bar=10.19716kgf/cm2 =145.0377psi 1kPa=10mbar=101.976mmH2O=4.01463H2O EDSX6-116k Date Apr. 1, 2007 FKX...4 Overrange limit: To maximum static pressure limit Output signal: 4 to 20mA DC (linear or square root) with digital signal superimposed on the 4 to 20mA signal. Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. Load limitations: see figure below ATEX 2000 1533Ω 1000 600Ω Operating area 24V 250 0 10 45V 16.1 10.5V Power voltage 50 [V] CSA - TIIS Ex do IIB+H2 T4 Tamb max = +55°C Maximum process temp.=+120°C IECEx Scheme /SAA Ex d IIC T5 IP66/67 pending Tamb = -40°C to +85°C Ex d IIC T6 IP66/67 pending Tamb = -40°C to +65°C (Note) 2 Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F, G T6 Type 4X Tamb max = +60°C (1) HHC: Hand Held Communicator Y,G,H,S -40°C to +85°C Y,G,H,S -20°C to +80°C Q,S,N,4,5,6 Y,G,H,S -20°C to +60°C E,F,G,H,K Y,G,H,S -40°C to +60°C W,A,D -10°C to +60°C Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F, G Class III Div.1 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Imax=93mA, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH TIIS Ex ia IIC T4 Tamb max = +60°C Entity Parameter: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=32.6nF, Li=1.134mH IECEx Scheme /SAA Ex ia IIC T4 IP66/67 Tamb = -40°C to +70°C Ex ia IIC T5 IP66/67 Tamb = -40°C to +50°C Entity Parameter: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=0.033µF, Li=1.034mH Flameproof Ex II 2 GD EEx d IIC T6 IP66/67 T85°C Tamb = -40°C to +65°C EEx d IIC T5 IP66/67 T100°C Tamb = -40°C to +85°C A,B,C,D,J L,P,M,1,2,3 CSA Hazardous locations: Authorities Tamb Entity Parameters: Vmax=42.4V, Imax=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH required. Factory Mutual Class I II III Div.1 Groups A, B, C, D, E, F, G T4 Entity Type 4X - Note: For communication with HHC(1) (Model: FXW), min. of 250Ω is ATEX Ex II 1 GD EEx ia IIC T5 Tamb = -40°C to +40°C EEx ia IIC T4 Tamb = -40°C to +80°C Model code 13th digit 9th digit 1500 500 Intrinsic safety Entity Parameters: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.134mH Factory Mutual [Ω] Load resistance Authorities ATEX “Output Underscale”: Adjustable within the range 3.2mA to 3.8mA from HHC(1) Type n Nonincendive Authorities Ex II 3 GD EEx nL IIC T5 Tamb = -40°C to +40°C EEx nL IIC T4 Tamb = -40°C to +80°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=27nF, Li=1.134mH Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH 3.2 Normal operating range Under scale Probable under range Burnout Class I II III Div.2 Groups A, B, C, D, F, G T4 Entity Type 4X Model code 13th digit 9th digit A,B,C,D,J Y,G,H,S -40°C to +85°C Y,G,H,S -20°C to +80°C Q,S,N,4,5,6 Y,G,H,S -20°C to +60°C CSA Tamb L,P,M,1,2,3 E,F,G,H,K Y,G,H,S -40°C to +60°C W,A,D -10°C to +60°C Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F, G Class III Div.2 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH TIIS - IECEx Scheme /SAA - 20 20.8 21.6 [mA] Over scale Burnout EEx nAL IIC T5 Tamb = -40°C to +40°C EEx nAL IIC T4 Tamb = -40°C to +80°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W, Model with arrester: Umax=32V, Imax=113mA, Pmax=1W Factory Mutual 3.8 4 Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code “L, P, M, Q, S, N”). Damping: Adjustable from HHC or local adjustment unit with LCD display. The time constant is adjustable between 0.12 to 32 seconds. Zero elevation/suppression: –100% to +100% of URL Normal/reverse action: Selectable from HHC(1) Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Adjustable within the range 20.8mA to 21.6mA from HHC(1) Probable over range Loop-check output: Transmitter can be configured to provide constant signal 3.8mA through 21.6mA by HHC(1). Temperature limit: Ambient: – 15 to + 65°C (– 15 to + 60°C for arrester option) (– 10 to + 60°C for fluorinated oil fill transmitter) (– 10 to + 60°C for silicone oil “H”, “S”) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. Process: Fill fluid 13th digit of “Code symbols” Fluorinated oil W, A and D Silicone oil H Process temperature – 20 to 120°C 0 to 250°C Y and G – 40 to 120°C S 0 to 250°C Lower limit of static press. Atmospheric pressure 2.7kPa abs {20mmHg abs} Storage: – 40 to +70°C Humidity limit: 0 to 100% RH Communication: With HHC (1) (Model FXW, consult Data Sheet No. EDS8-47), following information can be remotely displayed or reconfigured. Note: HHC’s version must be more than 6.0 (or FXW 1– 3), for FCXA2. Items Display Set Tag No. v v Model No. v v Serial No. v — Engineering unit v v Range limit v — Measuring range v v Damping v v Linear v v Square root v v Burnout direction v v Calibration v v Output adjust — v Data v — Self diagnoses v — Printer — — External switch lock v v Transmitter display v v Linearize v v Rerange v v Output mode Programmable output linearization function: Output signal can be characterized with “14 points linear approximation function” from HHC(1). EMC Conformity: EN61326 3 FKX...4 Static pressure effect: Zero shift; 0.2% of URL/1MPa (10 bar) Performance specifications Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode and capillary length 1.5m. Span shift: – 0.2% of calibrated span / 1MPa Accuracy rating: (including linearity, hysteresis, and repeatability) (Standard) For spans greater than 1/10 of URL: 0.25% of span For spans below 1/10 of URL: 0.1 x URL ± 0.17+0.08 % of span Span (Option) (Code; 21th digit H,K) For spans greater than 1/10 of URL: 0.1% of span For spans below 1/10 of URL: 0.1 x URL ± 0.05+0.05 % of span Span Stability: ± 0.2% of upper range limit (URL) for 3 years. Temperature effect: Effects per 28°C change between the limits of – 15°C and +65°C Zero shift: ± 0.5%/28°C (x equal to 1/2 URL or more) URL Zero shift; ± (0.5 )%/28°C 2x (x less than 1/2 URL) Total shift; ± 0.75%/28°C (x less than 1/2 URL or more) URL Total shift; ± (0.25 + 0.5 )%/28°C 2x (x less than 1/2 URL) (option) (Code; 21th digit J,K) Zero shift: ± 0.5%/28°C (x equal to 1/6.5 URL or more) URL Zero shift; ± (0.5 )%/28°C 6.5 x (x less than 1/6.5 URL) Total shift; ± 0.75%/28°C (x equal to 1/6.5 URL or more) URL Total shift; ± (0.25 + 0.5 )%/28°C 6.5 x (x less than 1/6.5 URL) Where, x: Calibrated span Overrange effect: Zero shift; 0.1% of URL for flange nominal pressure Supply voltage effect: Less than 0.005% fo calibrated span per 1V RFI effect: Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on. Update period: 120 msec *) Step response: (without electrical damping) ( ) ( ) URL: Maximum span (Upper Range Limit) Note : Above specifications are based on the conditions that flanges and sensor unit are at the same temperature and in the same level. If temperature is different at flanges, capillary or sensor unit, output variation may increase. 4 Time constant (*) 1.7 s Dead time (*) 0.2 s *) Faster response is available as option (maximum update rate: 25 times per second). Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Turn-on time: 4 sec. Internal resistance for external field indicator: 12Ω or less Physical specifications Indicator: A plug-in analog indicator (2.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. An optional 5-digit LCD meter with engineering unit is also available. Local adjustment unit with LCD display: An optional 5-digit LCD meter with Zero/ Span adjustment function, loop-check function and damping adjustment function, is available. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2 x 50µs). Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: Oil-free procedures as above. Includes fluorinated oil for fill. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. Vacuum service: Special silicone oil and filling procedure are applied. See Fig. 1. Optional tag plate: An extra stainless steel tag for customer tag data is wired to the transmitter. Coating of cell: Cell's surface is finished with epoxy/polyurethane double coating. Specify if environment is extremely corrosive. Filled liquid: Silicone (Code Y,G) [kPa abs] {m bar abs} Silicone (Code S) 101 {1010} Operating pressure Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 x 1.5 conduit, as specified. And 1-conduit or 2-conduit, as specified. Process connections: JIS 10K, 20K, 30K - 40, 50A 10K, 20K, 30K - 15, 20A (with Adapter) ANSI/JPI 150LB, 300LB -11/2", 2" 150LB, 300LB - 1/2", 3/4" (with Adapter) Screw connection (with Adapter); Rc1/2, Rc3/4, 1/2 - 14NPT, 3/4 - 14NPT Diaphragm extension: 0, 50, 100, 150, or 200mm as specified. (See model code. Extended diaphragm is available only with 316L stainless steel diaphragm) Process-wetted parts material: Diaphragm: 316L stainless steel, Hastelloy-C, Monel or Tantalum Flange face: 316 stainless steel, HastelloyC lining Monel lining, or Tantalum lining Extension: 316 stainless steel Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating (standard), or 316 stainless steel (SCSI4 par JIS G5121), as specified. Capillary: In case of 11th code “D. E. L.”, PVC armored stainless steel. In case of 11th code “Q. R. S”, stainless steel armored stainless steel. Mounting flange: 304 stainless steel or carbon steel. Fill fluid: Silicone oil (standard) or fluorinated oil Mounting bracket: 304 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting Mass {weight}: Transmitter approximately 15kg without options. Add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option 1.5kg per 50mm extension of diaphragm Optional features 53.3 {533} Operating area 13.3 {133} Non-operating area 2.7 {27} –40 0 60 85 120 Process temperature 200 230 250 [°C ] Fig. 1 Relation between process temperature and operating pressure ACCESSORIES Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS 8-47) Z/S board: Parts No.=ZZPFCX4-A070 When Z/S board is mounted on the FCX– A2 amplifier unit, external adjustment screw will be available for zero and span adjustment. 5 FKX...4 CODE SYMBOLS 1 2 3 4 5 6 7 8 Digit 4 5 6 7 Description <Conduit connections> G 1/2 (×1) 1/2 - 14NPT (×1) Combination with 12th digit code "C, E, P, Q"are not available. Pg13.5 (×1) M20 × 1.5 (×1) G 1/2 (×2) 1/2 - 14NPT (×2) Pg13.5 (×2) M20 × 1.5 (×2) <Flange> Material Size and rating 304 stainless JIS 10K 40A steel JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A JIS 63K 40A JIS 63K 50A ANSI/JPI 150LB 1 1/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 1 1/2" ANSI/JPI 300LB 2" ANSI/JPI 600LB 1 1/2B ANSI/JPI 600LB 2B Carbon steel JIS 10K 40A JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A JIS 63K 40A JIS 63K 50A ANSI/JPI 150LB 1 1/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 1 1/2" ANSI/JPI 300LB 2" ANSI/JPI 600LB 1 1/2B ANSI/JPI 600LB 2B None 40A, 1 1/2B (Wafer type) 50A, 2B Direct mounting adapter connection (* 1) <Span limit [kPa] {m bar}> 3........32(30...320) 13......130(130...1300) (*2) 50......500(500...5000) <Material/diapharagm extension> Flange face Diaphragm extension(mm) Diaphragm 0 316L stainless steel 316 stainless steel 50 100 (*3) 150 200 0 316L stainless steel +Au coating 0 Hastelloy-C Hastelloy-C 0 Monel Monel 0 Tantalum Tantalum Note 1: (*1) Note 2: (*2) Note 3: (*3) 6 Note F KX 9 10 11 12 13 14 15 16 17 18 19 20 4 A B C D S T V W Note 1 Note 2 Note 3 0 1 2 3 4 5 6 7 A B C D E F G H J K L M N P Q R S T U V W X Y 3 5 6 V A B C D J H M T Direct mounting adapter type is specified at 16th to 20th digit. Direct mounting adapter is available only for 7th digit code "V". 100:1 turn down is possible for model FKX, but should be used within indicated span for better performance. Diaphragm extension is available only for 2" (50A) flanges. 21 Digit No. of code 1 2 3 4 5 6 7 8 Digit 9 10 11 12 13 14 Description <Indicator and arrester> Indicator Arrester Note None None Analog, 0 to 100% linear scale None Analog, 0 to 100% sq. root scale None Z/S board Analog, custom scale None attached. Analog, double scale(Linear and sq.root) None None Yes Analog, 0 to 100% linear scale Yes Analog, 0 to 100% sq. root scale Yes Analog, custom scale Yes Analog, double scale(Linear and sq.root) Yes Digital, 0 to 100% None Digital, custom scale None Digital, 0 to 100% square root None Digital, 0 to 100% Yes Digital, custom scale Yes Digital, 0 to 100% square root Yes Digital, 0 to 100% (Local adjustment unit with LCD display) None Digital, custom scale (Local adjustment unit with LCD display) None Digital, 0 to 100% square root (Local adjustment unit with LCD display) None Digital, 0 to 100% (Local adjustment unit with LCD display) Yes Digital, custom scale (Local adjustment unit with LCD display) Yes Digital, 0 to 100% square root (Local adjustment unit with LCD display) Yes <Approvals for hazardous locations> None (for ordinary locations) TIIS, Flameproof (Conduit seal) (Available for 4th digit code "A", "S") TIIS, Flameproof (Cable gland seal) (Available for 4th digit code "A", "S") FM, Flameproof (or explosionproof) (Available for 4th digit code "B", "T") ATEX, Flameproof IECEx Scheme/SAA, Flameproof (Approval pending) TIIS, Intrinsic safety FM, Intrinsic safety and Nonincendive ATEX, Intrinsic safety ATEX, Type n IECEx Scheme/SAA, Intrinsic safety FM, Combined of Flameproof and Intrinsic safety <Capillary and mounting bracket> mounting bracket Capillary armor of capillary Stainless steel 1.5m PVC Note5 3m (*5) 5m 1.5m Stainless steel 3m 5m <Options> Extra ss tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None (*4) Note4 Yes Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Treatment/Fill fluid> Treatment Fill fluid Standard Silicone oil (for general use) Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code "V", "A", "B", "C" and "D") Chlorine service Fluorinated oil (7th digit code "H" and "T") High temp. 250°C Silicone oil (7th digit code "V", "A", "B", "C", "D" and "H") High temp. and vacuum (250°C) Silicone oil (7th digit code "V", "A", "B", "C" and "D") <Teflon membrane> None Yes (Available for 7th digit code "V", "H", "M" and "T". Not available for 5th digit code "Y" and 13th digit code "H", "S".) Note 4: (*4) Note 5: (*5) F KX 9 10 11 12 13 14 15 16 17 18 19 20 4 0 21 Digit No. of code A B C D J E F G H K L P M Q S N 1 2 3 4 5 6 A B C D X R G H K P T V D E L Q R S Y B C E M N P Q Y W G A D H S Y C Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select "Yes". Available for 13th digit code "Y", "W", "G", "A" and "D". 7 FKX...4 Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4") connection} and others Note 1. When odering the instrument with direct mounting adapter, specify “Y” in the 5th digit of Code Symbol, and specify 16th digit to 20th digit. When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digit. 2. Unless otherwise described in the specifications, leave the 21st digit blank. 1 2 3 4 5 6 7 8 Digit Description Note 16, 17 <Process connection (direct mounting adapter)> JIS 10K 15A JIS 10K 20A JIS 20K 15A JIS 20K 20A JIS 30K 15A JIS 30K 20A ANSI/JPI 150LB 1/2" ANSI/JPI 150LB 3/4" ANSI/JPI 300LB 1/2" ANSI/JPI 300LB 3/4" Screw connection Rc1/2 Screw connection Rc3/4 Screw connection Rc1/2 - 14NPT Screw connection Rc3/4 - 14NPT 18 <Material (direct mounting adapter)> (*6) Note 6 Adapter Bolts/nuts (* 6) 316 Stainless Steel Cr-Mo steel/carbon steel 19 <Vent/drain (for direct mounting adapter)> Standard Long type 20 <Gasket (for direct mounting adapter)> Standard (Teflon) (Only Y, W, G, A and D can be specified on 13th digit). For high temperature (spiral gasket) (Only H and S can be specified on 13th digit). 21 Note 7 <Other options> (*7) High accuracy type Instruction manual attached Low temperature effect type Instruction manual attached H+J Instruction manual attached Instruction manual unattached High accuracy type Instruction manual unattached Low temperature effect type Instruction manual unattached T+U Instruction manual unattached F KX Note 6: (*6) For connection of transmitter receiving pressure unit and direct mounting adapter Note 7: (*7) If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. 8 4 9 10 11 12 13 14 15 16 17 18 19 20 21 0 1 1 1 2 2 1 2 2 3 1 3 2 1H 1 T 2H 2 T SR S 2 SN ST W A N 1 2 H J K L T U V Digit No. of code The product conforms to the requirements of the Electromagnetic compatibility Directive 94/9/EC as detailed within the technical construction file number TN513035. The applicable standards used to demonstrate compliance are : EMI (Emission) EN61326 : 1997 Class A (standard for Industrial Location) Frequency range MHz Limits Reference standard 30 to 230 40dB (µV/m) quasi peak, measured at 10m distance CISPR16-1 and CISPR16-2 230 to 1000 47dB (µV/m) quasi peak, measured at 10m distance EMI (Immunity) When ordering this instrument, specify: 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occurred in the transmitter. Hold / Overscale (21.6mA) / Underscale (3.2mA) Unless otherwise specified, output hold function is supplied. 4. Output mode (linear or square root output) Unless otherwise specified, output mode is linear. 5. Indication method (indicated value and unit) in case of the actual scale (code D, H, P, S on 9th digit). 6. Tag No. (up to 26 alphanumerical characters), if required. EN61326: 1997 Annex A (standard for Industrial Location) Phenomenon Electrostatic discharge ORDERING INFORMATION Test value 4kV (Contact) 8kV (Air) Basic standard Performance criteria EN61000-4-2 B 80 to 1000MHz Electromagnetic 10V/m field 80%AM (1kHz) EN61000-4-3 A Rated power frequency magnetic field 30A/m 50Hz EN61000-4-8 A Burst 2kV 5kHz EN61000-4-4 B Surge 1.2µs/50µs 1kV (Line to line) 2kV (Line to ground) EN61000-4-5 B Conducted RF 0.15 to 80MHz 3V 80%AM (1kHz) EN61000-4-6 A Note) Definition of performance criteria A: During testing, normal performance within the specification limits. B: During testing, temporary degradation, or loss of function or performance which is self-recovering. 9 FKX...4 OUTLINE DIAGRAM (Unit:mm) In case of 4th digit code "A.B.C.D.E" In case of 4th digit code "T" MTG. pipe JIS 50A (2B) In case of 4th digit code "S.V.W.X" Fastene (Flameproof only) 10 8 94.5 U-bolt M8 ø80 104 105 70 ø80 52.5 105 UP 88 DOWN 38 28 4 holes 9 dia. 58 201 (27) "B" Conduit conn. Zero ADJ. screw Note) "A" Conduit conn. Cable gland (option) With field IND. N holes h dia. 71 øD øE ø84 ø49 ø48 Inner of gasket 20 L t 270 48 43 No flange is attached in case of 5th digit code W, X" Earth terminal Detail "A" Detail "B" ø13 Electronics unit 75 17 K J 222 M ø15 <Optional stainless steel tag> ø1/2 S 20 S L.P. 2-M8 12 See table 1 70 120 5th digit of code symbols 0, G 1, H 2, J 3, K 4, L 5, M 6, N 7, P A, Q B, R C, S D, T E, U F, V øD øE t N-øh (Flange) 140 155 140 155 160 165 175 185 127 152 156 165 156 165 105 120 105 120 120 130 130 145 98.4 120.6 114.3 127 114.3 127 36 36 38 38 42 42 52 54 37.5 39.5 41 42.5 42.5 45.5 4-19 4-19 4-19 8-19 4-23 8-19 4-25 8-23 4-16 4-20 4-23 8-20 4-23 8-20 JIS-10K-40A JIS-10K-50A JIS-20K-40A JIS-20K-50A JIS-30K-40A JIS-30K-50A JIS-63K-40A JIS-63K-50A ANSI/JPI-150LB-1 1/2B ANSI/JPI-150LB-2B ANSI/JPI-300LB-1 1/2B ANSI/JPI-300LB-2B ANSI/JPI-600LB-1 1/2B ANSI/JPI-600LB-2B 71 K 17 B, T 1/2-14NPT C, V Pg13.5 M20 1.5 M 8 11th digit of Code symbols Capillary length [mm] 16 5 8 4.5 16 5 D, Q E, R L, S 1500 3000 5000 7th digit of Code symbols L Mass approx. [kg] V, H, M, T, J A B C D 0 50 100 150 200 14 to 19.5 15 to 30.5 15.5 to 31 16 to 31.5 16.5 to 32 Note : In case of wafer type, flange is excluded from the scope of supply. Mount flange, referring to the view. <Wafer type> 10 G1/2 TABLE 1 20 Note) 62 Conduit conn. J D, W 2-M6 screw depth 9 ø84 ø49 Inner of gasket 4th digit of the Code symbols 3, 4, A, S Sensor unit H.P. Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable. CONNECTION DIAGRAM CK CK <With direct mount adaptor> Vent/drain plug N holes, h dia. øF øE øD ø84 25 (102) Long vent/drain plug (option) S In case of 4th digit code "A.B.C.D.E" L. P. H. P. t 20 In case of 4th digit code "S.V.W.X" In case of 4th digit code "T" Fastener (Flameproof only) 8 10 U-bolt M8 94.5 ø80 105 70 ø80 52.5 105 UP 104 MTG. pipe JIS 50A(2B) 80 88 DOWN 38 28 4 holes 9 dia. 201 58 Note) (27) Cable gland (option) "B" Conduit conn. With field IND. "A" Conduit conn. Detail "A" Zero ADJ. screw Detail "B" CONNECTION DIAGRAM ø13 ø15 K 17 M CK CK Table 1 J 11th digit of Capillary Code symbols length [mm] Conduit conn. 4th digit of the Code symbols J K M 3, 4, A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 D, Q E, R L, S ø1/2 270 48 43 1500 3000 5000 5 16th digit of 17th digit of øD code symbols code symbols 1 1 2 2 3 3 1 1 2 2 Note) 1 2 1 2 1 2 H T H T 95 100 95 100 115 120 89 98 95 117 øE øF t N-øh Flange 70 75 70 75 80 85 60.3 69.9 66.7 82.5 51 56 51 56 55 60 34.9 42.9 34.9 42.9 12 14 14 16 18 18 11.5 13 14.5 16 4-15 4-15 4-15 4-15 4-19 4-19 4-16 4-16 4-16 4-20 JIS-10K-15A JIS-10K-20A JIS-20K-15A JIS-20K-20A JIS-30K-15A JIS-30K-20A ANSI/JPI-150LB 1/2B ANSI/JPI-150LB 3/4B ANSI/JPI-300LB 1/2B ANSI/JPI-300LB 3/4B 222 Electronics unit Earth terminal Sensor unit 2-M8 12 70 120 62 Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable. 11 FKX...4 <With direct mount adaptor (screw connection type)> Long vent/drain plug (option) 25 High press. conn. "D" ø84 Vent/drain plug (102) Low press. conn. D" S In case of 4th digit code "A.B.C.D.E" 20 23 In case of 4th digit code "S.V.W.X" U-bolt M8 Fastener (Flameproof only) 8 94.5 In case of 4th digit code "T" 10 ø80 105 70 ø80 52.5 105 UP 104 MTG. pipe JIS 50A (2B) 88 DOWN 38 28 Note) 4 holes 9 dia. 58 201 "A" Conduit conn. Detail "A" Cable gland (option) (27) "B" Conduit conn Zero ADJ. screw With field IND. 270 48 43 Detail "B" ø13 CONNECTION DIAGRAM M ø15 CK CK Electronics unit 17 K J Earth termina 222 G1/2 Table 1 Conduit conn. 4th digit of the J K M Code symbols A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 5 16th digit of Code symbols 11th digit of Code symbols D, Q E, R L, S 17th digit of Code symbols Capillary length [mm] 1500 3000 5000 2-M8 12 70 120 Press. conn."D" S R S N 1/2-14NPT S 2 Rc 3/4 S T 3/4-14NPT Sensor unit 62 Rc 1/2 Note) Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan