TI 54ACT11353

SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993
•
•
•
•
•
•
•
54ACT11353 . . . J PACKAGE
74ACT11535 . . . D OR N PACKAGE
Inverting Versions of 54ACT11253 and
74ACT11253
Permits Multiplexing From N Lines
to 1 Line
Performs Parallel-to-Serial Conversion
Inputs Are TTL-Voltage Compatible
Flow-Through Architecture to Optimize
PCB Layout
Center-Pin VCC and GND Configurations to
Minimize High-Speed Switching Noise
EPICt (Enhanced-Performance Implanted
CMOS) 1-mm Process
Package Options Include Plastic SmallOutline Packages, Ceramic Chip Carriers,
and Standard Plastic and Ceramic 300-mil
DIPs
(TOP VIEW)
A
B
1Y
GND
2Y
1G
2G
2C3
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
1C0
1C1
1C2
1C3
VCC
2C0
2C1
2C2
54ACT11353 . . . FK PACKAGE
(TOP VIEW)
1C2
1C3
NC
VCC
2C0
•
description
1C1
1C0
NC
A
B
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
2C1
2C2
NC
2C3
2G
1Y
GND
NC
2Y
1G
Each of these data selectors/multiplexers
contains inverters and drivers to supply full binary
decoding data selection to the AND-OR gates.
Separate strobe inputs (G) are provided for each
of the two four-line sections.
4
The 3-state outputs can interface with and drive
data lines of bus-organized systems. With all but
one of the common outputs disabled (at a
high-impedance state), the low-impedance of the
single enabled output will drive the bus line to a
high or low logic level. Each output has its own
strobe (G). The output is disabled when its strobe
is high.
The 54ACT11353 is characterized for operation over the full military temperature range of − 55°C to 125°C.
The 74ACT11353 is characterized for operation from − 40°C to 85°C.
FUNCTION TABLE
SELECT
INPUTS
DATA INPUTS
C3
STROBE
G
OUTPUT
Y
B
A
C0
C1
C2
X
X
X
X
X
X
H
Z
L
L
L
X
X
X
L
H
L
L
H
X
X
X
L
L
L
H
X
L
X
X
L
H
L
H
X
H
X
X
L
L
H
L
X
X
L
X
L
H
H
L
X
X
H
X
L
L
H
H
X
X
X
L
L
H
H
H
X
X
X
H
L
L
EPIC is a trademark of Texas Instruments Incorporated.
Copyright  1993, Texas Instruments Incorporated
!"#$%! & '("")% $& ! *(+,'$%! -$%).
"!-('%& '!!"# %! &*)''$%!& *)" %/) %)"#& ! )0$& &%"(#)%&
&%$-$"- 1$""$%2. "!-('%! *"!')&&3 -!)& !% )')&&$",2 ',(-)
%)&%3 ! $,, *$"$#)%)"&.
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
•
2−1
SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993
logic symbol†
1
A
0
2
B
1
MUX
6
1G
16
1C0
15
1C1
14
1C2
13
1C3
7
2G
G0
3
EN
0
3
1
1Y
2
3
11
2C0
5
10
2C1
9
2C2
2Y
8
2C3
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram (positive logic)
1G
1C0
1C1
6
16
15
3
Data 1
1C2
1C3
B
1Y
14
13
2
Select
A
2C0
2C1
1
11
10
Data 2
5
2C2
2C3
2G
9
8
7
Pin numbers shown are for the D, J, and N packages.
2−2
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
•
2Y
SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
recommended operating conditions
54ACT11353
MIN
MAX
MIN
MAX
4.5
5.5
4.5
5.5
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
Input voltage
0
VO
IOH
Output voltage
0
High-level output current
IOL
Dt /Dv
Low-level output current
TA
Operating free-air temperature
High-level input voltage
74ACT11353
2
2
0.8
Input transition rise or fall rate
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
•
UNIT
V
V
0.8
V
VCC
VCC
V
−24
−24
mA
24
24
mA
VCC
VCC
0
0
V
0
10
0
10
ns/ V
−55
125
− 40
85
°C
2−3
SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
IOH = − 50 mA
A
VOH
IOH = − 24 mA
IOH = − 50 mA{
IOH = − 75 mA{
54ACT11353
74ACT11353
MIN
MIN
MIN
4.5 V
4.4
4.4
4.4
5.5 V
5.4
5.4
5.4
4.5 V
3.94
3.7
3.8
5.5 V
4.94
4.7
4.8
5.5 V
MAX
UNIT
V
3.85
4.5 V
IOL = 24 mA
MAX
3.85
5.5 V
IOL = 50 mA
A
VOL
TA = 25°C
TYP
MAX
VCC
0.1
0.1
0.1
5.5 V
0.1
0.1
0.1
4.5 V
0.36
0.5
0.44
5.5 V
0.36
0.5
0.44
V
IOL = 50 mA{
IOL = 75 mA{
5.5 V
IOZ
II
VO = VCC or GND
VI = VCC or GND
5.5 V
± 0.5
± 10
±5
mA
5.5 V
± 0.1
±1
±1
mA
ICC
VI = VCC or GND,
5.5 V
8
160
80
mA
DICC}
One input at 3.4 V,
Other inputs at GND or VCC
5.5 V
0.9
1
1
mA
Ci
VI = VCC or GND
VO = VCC or GND
1.65
5.5 V
IO = 0
1.65
5V
3.5
pF
Co
5V
8
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V to VCC.
pF
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A or B
Any Y
tPLH
tPHL
Data (Any C)
Any Y
tPZH
tPZL
G
Any Y
tPHZ
tPLZ
G
Any Y
MIN
TA = 25°C
TYP
MAX
54ACT11353
74ACT11353
MIN
MAX
MIN
MAX
1.5
6.6
11.1
1.5
13.8
1.5
12.7
1.5
5.9
8.3
1.5
10.1
1.5
9.4
1.5
6.3
9.8
1.5
12.3
1.5
11
1.5
5.3
7.2
1.5
10.5
1.5
8
1.5
4.3
6.8
1.5
7.9
1.5
7.4
1.5
4.2
6.7
1.5
7.8
1.5
7.4
1.5
6.1
7.8
1.5
8.6
1.5
8.2
1.5
5.4
6.9
1.5
7.6
1.5
7.3
UNIT
ns
ns
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
TEST CONDITIONS
Outputs enabled
Cpd
2−4
Power dissipation capacitance per multiplexer
Outputs disabled
•
UNIT
39
CL = 50 pF,
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
•
TYP
f = 1 MHz
19
pF
SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993
PARAMETER MEASUREMENT INFORMATION
2 × VCC
S1
500 Ω
From Output
Under Test
Open
GND
CL = 50 pF
(see Note A)
Output
Control
(low-level
enabling)
3V
1.5 V
0V
tPHL
Output
Waveform 2
S1 at GND
(see Note C)
VOH
50% VCC
3V
50% VCC
VOL
1.5 V
1.5 V
0V
tPZL
tPLZ
Output
Waveform 1
S1 at 2 × VCC
(see Note C)
1.5 V
tPLH
Output
S1
Open
2 × VCC
GND
500 Ω
LOAD CIRCUIT
Input
(see Note B)
TEST
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
50% VCC
20% VCC
VOL
tPHZ
tPZH
VOLTAGE WAVEFORMS
[ VCC
50% VCC
80% VCC
VOH
[0V
VOLTAGE WAVEFORMS
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
D. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
•
2−5
SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993
2−6
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
•
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Amplifiers
Data Converters
DLP® Products
DSP
Clocks and Timers
Interface
Logic
Power Mgmt
Microcontrollers
RFID
RF/IF and ZigBee® Solutions
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
dsp.ti.com
www.ti.com/clocks
interface.ti.com
logic.ti.com
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/lprf
Applications
Audio
Automotive
Broadband
Digital Control
Medical
Military
Optical Networking
Security
Telephony
Video & Imaging
Wireless
www.ti.com/audio
www.ti.com/automotive
www.ti.com/broadband
www.ti.com/digitalcontrol
www.ti.com/medical
www.ti.com/military
www.ti.com/opticalnetwork
www.ti.com/security
www.ti.com/telephony
www.ti.com/video
www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2009, Texas Instruments Incorporated