SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993 • • • • • • • 54ACT11353 . . . J PACKAGE 74ACT11535 . . . D OR N PACKAGE Inverting Versions of 54ACT11253 and 74ACT11253 Permits Multiplexing From N Lines to 1 Line Performs Parallel-to-Serial Conversion Inputs Are TTL-Voltage Compatible Flow-Through Architecture to Optimize PCB Layout Center-Pin VCC and GND Configurations to Minimize High-Speed Switching Noise EPICt (Enhanced-Performance Implanted CMOS) 1-mm Process Package Options Include Plastic SmallOutline Packages, Ceramic Chip Carriers, and Standard Plastic and Ceramic 300-mil DIPs (TOP VIEW) A B 1Y GND 2Y 1G 2G 2C3 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 1C0 1C1 1C2 1C3 VCC 2C0 2C1 2C2 54ACT11353 . . . FK PACKAGE (TOP VIEW) 1C2 1C3 NC VCC 2C0 • description 1C1 1C0 NC A B 3 2 1 20 19 18 5 17 6 16 7 15 8 14 9 10 11 12 13 2C1 2C2 NC 2C3 2G 1Y GND NC 2Y 1G Each of these data selectors/multiplexers contains inverters and drivers to supply full binary decoding data selection to the AND-OR gates. Separate strobe inputs (G) are provided for each of the two four-line sections. 4 The 3-state outputs can interface with and drive data lines of bus-organized systems. With all but one of the common outputs disabled (at a high-impedance state), the low-impedance of the single enabled output will drive the bus line to a high or low logic level. Each output has its own strobe (G). The output is disabled when its strobe is high. The 54ACT11353 is characterized for operation over the full military temperature range of − 55°C to 125°C. The 74ACT11353 is characterized for operation from − 40°C to 85°C. FUNCTION TABLE SELECT INPUTS DATA INPUTS C3 STROBE G OUTPUT Y B A C0 C1 C2 X X X X X X H Z L L L X X X L H L L H X X X L L L H X L X X L H L H X H X X L L H L X X L X L H H L X X H X L L H H X X X L L H H H X X X H L L EPIC is a trademark of Texas Instruments Incorporated. Copyright 1993, Texas Instruments Incorporated !"#$%! & '("")% $& ! *(+,'$%! -$%). "!-('%& '!!"# %! &*)''$%!& *)" %/) %)"#& ! )0$& &%"(#)%& &%$-$"- 1$""$%2. "!-('%! *"!')&&3 -!)& !% )')&&$",2 ',(-) %)&%3 ! $,, *$"$#)%)"&. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • 2−1 SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993 logic symbol† 1 A 0 2 B 1 MUX 6 1G 16 1C0 15 1C1 14 1C2 13 1C3 7 2G G0 3 EN 0 3 1 1Y 2 3 11 2C0 5 10 2C1 9 2C2 2Y 8 2C3 † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. logic diagram (positive logic) 1G 1C0 1C1 6 16 15 3 Data 1 1C2 1C3 B 1Y 14 13 2 Select A 2C0 2C1 1 11 10 Data 2 5 2C2 2C3 2G 9 8 7 Pin numbers shown are for the D, J, and N packages. 2−2 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • 2Y SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed. recommended operating conditions 54ACT11353 MIN MAX MIN MAX 4.5 5.5 4.5 5.5 VCC VIH Supply voltage VIL VI Low-level input voltage Input voltage 0 VO IOH Output voltage 0 High-level output current IOL Dt /Dv Low-level output current TA Operating free-air temperature High-level input voltage 74ACT11353 2 2 0.8 Input transition rise or fall rate • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • UNIT V V 0.8 V VCC VCC V −24 −24 mA 24 24 mA VCC VCC 0 0 V 0 10 0 10 ns/ V −55 125 − 40 85 °C 2−3 SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS IOH = − 50 mA A VOH IOH = − 24 mA IOH = − 50 mA{ IOH = − 75 mA{ 54ACT11353 74ACT11353 MIN MIN MIN 4.5 V 4.4 4.4 4.4 5.5 V 5.4 5.4 5.4 4.5 V 3.94 3.7 3.8 5.5 V 4.94 4.7 4.8 5.5 V MAX UNIT V 3.85 4.5 V IOL = 24 mA MAX 3.85 5.5 V IOL = 50 mA A VOL TA = 25°C TYP MAX VCC 0.1 0.1 0.1 5.5 V 0.1 0.1 0.1 4.5 V 0.36 0.5 0.44 5.5 V 0.36 0.5 0.44 V IOL = 50 mA{ IOL = 75 mA{ 5.5 V IOZ II VO = VCC or GND VI = VCC or GND 5.5 V ± 0.5 ± 10 ±5 mA 5.5 V ± 0.1 ±1 ±1 mA ICC VI = VCC or GND, 5.5 V 8 160 80 mA DICC} One input at 3.4 V, Other inputs at GND or VCC 5.5 V 0.9 1 1 mA Ci VI = VCC or GND VO = VCC or GND 1.65 5.5 V IO = 0 1.65 5V 3.5 pF Co 5V 8 † Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. ‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V to VCC. pF switching characteristics over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A or B Any Y tPLH tPHL Data (Any C) Any Y tPZH tPZL G Any Y tPHZ tPLZ G Any Y MIN TA = 25°C TYP MAX 54ACT11353 74ACT11353 MIN MAX MIN MAX 1.5 6.6 11.1 1.5 13.8 1.5 12.7 1.5 5.9 8.3 1.5 10.1 1.5 9.4 1.5 6.3 9.8 1.5 12.3 1.5 11 1.5 5.3 7.2 1.5 10.5 1.5 8 1.5 4.3 6.8 1.5 7.9 1.5 7.4 1.5 4.2 6.7 1.5 7.8 1.5 7.4 1.5 6.1 7.8 1.5 8.6 1.5 8.2 1.5 5.4 6.9 1.5 7.6 1.5 7.3 UNIT ns ns ns ns operating characteristics, VCC = 5 V, TA = 25°C PARAMETER TEST CONDITIONS Outputs enabled Cpd 2−4 Power dissipation capacitance per multiplexer Outputs disabled • UNIT 39 CL = 50 pF, POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • TYP f = 1 MHz 19 pF SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993 PARAMETER MEASUREMENT INFORMATION 2 × VCC S1 500 Ω From Output Under Test Open GND CL = 50 pF (see Note A) Output Control (low-level enabling) 3V 1.5 V 0V tPHL Output Waveform 2 S1 at GND (see Note C) VOH 50% VCC 3V 50% VCC VOL 1.5 V 1.5 V 0V tPZL tPLZ Output Waveform 1 S1 at 2 × VCC (see Note C) 1.5 V tPLH Output S1 Open 2 × VCC GND 500 Ω LOAD CIRCUIT Input (see Note B) TEST tPLH/tPHL tPLZ/tPZL tPHZ/tPZH 50% VCC 20% VCC VOL tPHZ tPZH VOLTAGE WAVEFORMS [ VCC 50% VCC 80% VCC VOH [0V VOLTAGE WAVEFORMS NOTES: A. CL includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns. C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. D. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • 2−5 SCAS045A − D3109, JUNE 1988 − REVISED APRIL 1993 2−6 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DLP® Products DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com www.dlp.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2009, Texas Instruments Incorporated