TI 74ACT16620

SCAS184A − JUNE 1990 − REVISED APRIL 1996
D Members of the Texas Instruments
D
D
D
D
D
D
D
54ACT16620 . . . WD PACKAGE
74ACT16620 . . . DL PACKAGE
(TOP VIEW)
Widebus  Family
Inputs Are TTL-Voltage Compatible
Inverting Logic
Flow-Through Architecture Optimizes
PCB Layout
Distributed VCC and GND Pin Configuration
Minimizes High-Speed Switching Noise
EPIC  (Enhanced-Performance Implanted
CMOS) 1-µm Process
500-mA Typical Latch-Up Immunity at
125°C
Package Options Include Plastic 300-mil
Shrink Small-Outline (DL) Packages Using
25-mil Center-to-Center Pin Spacings and
380-mil Fine-Pitch Ceramic Flat (WD)
Packages Using 25-mil Center-to-Center
Pin Spacings
1OEAB
1B1
1B2
GND
1B3
1B4
VCC
1B5
1B6
GND
1B7
1B8
2B1
2B2
GND
2B3
2B4
VCC
2B5
2B6
GND
2B7
2B8
2OEAB
description
The ’ACT16620 are inverting 16-bit transceivers
designed for asynchronous communication
between data buses. The control-function
implementation allows for maximum flexibility in
timing.
These devices can be used as two 8-bit
transceivers or one 16-bit transceiver. They allow
data transmission from the A bus to the B bus or
from the B bus to the A bus, depending on the logic
level at the output-enable (OEAB or OEBA)
inputs. The output-enable inputs can be used to
disable the device so that the buses are effectively
isolated.
1
48
2
47
3
46
4
45
5
44
6
43
7
42
8
41
9
40
10
39
11
38
12
37
13
36
14
35
15
34
16
33
17
32
18
31
19
30
20
29
21
28
22
27
23
26
24
25
1OEBA
1A1
1A2
GND
1A3
1A4
VCC
1A5
1A6
GND
1A7
1A8
2A1
2A2
GND
2A3
2A4
VCC
2A5
2A6
GND
2A7
2A8
2OEBA
The dual-enable configuration gives the transceiver the capability to store data by simultaneously enabling
OEAB and OEBA. Each output reinforces its input in this transceiver configuration. Thus, when both control
inputs are enabled and all other data sources to the two sets of bus lines are at high impedance, the bus lines
remain at their last states.
The 74ACT16620 is packaged in TI’s shrink small-outline package, which provides twice the I/O pin count and
functionality of standard small-outline packages in the same printed-circuit-board area.
The 54ACT16620 is characterized for operation over the full military temperature range of −55°C to 125°C. The
74ACT16620 is characterized for operation from −40°C to 85°C.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC and Widebus are trademarks of Texas Instruments Incorporated.
Copyright  1996, Texas Instruments Incorporated
!"#$%&' #"'(' ')"*%("' #$**&' ( ") +$,-#("' !(&. *"!$# #"')"*% "
+&#)#("' +&* & &*% ") &/( '*$%&' ('!(*! 0(**('1.
*"!$#"' +*"#&'2 !"& '" '&#&(*-1 '#-$!& &'2 ") (-+(*(%&&*.
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
1
SCAS184A − JUNE 1990 − REVISED APRIL 1996
FUNCTION TABLE
(each 8-bit section)
INPUTS
OPERATION
OEBA
OEAB
L
L
B data to A bus
L
H
B data to A bus,
A data to B bus
H
L
Isolation
H
H
A data to B bus
logic symbol†
48
1OEBA
1OEAB
1
25
2OEBA
2OEAB
1A1
24
EN1
EN2
EN3
EN4
47
2
1
1
1
1A2
1A3
1A4
1A5
1A6
1A7
1A8
2A1
3
44
5
43
6
41
8
40
9
38
11
37
12
36
13
1
1
2A2
2A3
2A4
2A5
2A6
2A7
2A8
2
46
3
35
14
33
16
32
17
30
19
29
20
27
22
26
23
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
1B2
1B3
1B4
1B5
1B6
1B7
1B8
2B1
4
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
2
1B1
2B2
2B3
2B4
2B5
2B6
2B7
2B8
SCAS184A − JUNE 1990 − REVISED APRIL 1996
logic diagram (positive logic)
1OEBA
1OEAB
1A1
48
2OEBA
1
2OEAB
47
2A1
2
25
24
36
13
2B1
1B1
To Seven Other Channels
To Seven Other Channels
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±400 mA
Maximum package power dissipation at TA = 55°C (in still air) (see Note 2): DL package . . . . . . . . . . . 1.2 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150_C and a board trace length of 750 mils.
recommended operating conditions (see Note 3)
54ACT16620
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
Input voltage
0
VO
IOH
Output voltage
0
High-level output current
IOL
∆t/∆v
Low-level output current
High-level input voltage
74ACT16620
2
2
0.8
Input transition rise or fall rate
TA
Operating free-air temperature
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
UNIT
V
V
0.8
V
VCC
VCC
V
−24
−24
mA
24
24
mA
VCC
VCC
0
0
V
0
10
0
10
ns/V
−55
125
−40
85
°C
')"*%("' #"'#&*' +*"!$# ' & )"*%(3& "*
!&2' +(& ") !&3&-"+%&'. (*(#&*# !(( ('! "&*
+&#)#("' (*& !&2' 2"(-. &/( '*$%&' *&&*3& & *2 "
#('2& "* !#"''$& && +*"!$# 0"$ '"#&.
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
3
SCAS184A − JUNE 1990 − REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
74ACT16620
4.5 V
4.4
4.4
4.4
5.5 V
5.4
5.4
5.4
4.5 V
3.94
3.8
3.8
IOH = −24 mA
5.5 V
4.94
4.8
4.8
IOH = −75 mA†
5.5 V
IOL = 24 mA
MIN
MAX
3.85
4.5 V
IOL = 50 µA
A
VOL
54ACT16620
MIN
IOH = −50 µA
A
VOH
TA = 25°C
TYP
MAX
VCC
0.1
MIN
MAX
UNIT
V
3.85
0.1
0.1
5.5 V
0.1
0.1
0.1
4.5 V
0.36
0.44
0.44
5.5 V
0.36
0.44
0.44
1.65
1.65
V
II
Control inputs
IOL = 75 mA†
VI = VCC or GND
IOZ‡
A or B ports
VO = VCC or GND
5.5 V
±0.5
±5
±5
µA
VI = VCC or GND,
IO = 0
One input at 3.4 V,
Other inputs at VCC or GND
5.5 V
8
80
80
µA
5.5 V
0.9
1
1
mA
ICC
∆ICC§
Ci
Control inputs
Cio
A or B ports
5.5 V
5.5 V
±0.1
±1
±1
µA
VI = VCC or GND
VO = VCC or GND
5V
4
pF
5V
15
pF
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ For I/O ports, the parameter IOZ includes the input leakage current.
§ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A or B
B or A
tPZH
tPZL
OEBA
A
tPHZ
tPLZ
OEBA
A
tPZH
tPZL
OEAB
B
tPHZ
tPLZ
OEAB
B
MIN
TA = 25°C
TYP
MAX
54ACT16620
74ACT16620
MIN
MAX
MIN
MAX
2
5
7.7
2
8.5
2
8.5
4
7
9.3
4
10.5
4
10.5
2.2
5.5
8.3
2.2
9.1
2.2
9.1
2.8
6.4
10
2.8
10.9
2.8
10.9
6
8.8
11
6
11.9
6
11.9
5.1
7.9
10
5.1
10.6
5.1
10.6
3.6
6.2
7.9
3.6
8.9
3.6
8.9
4.4
7.1
9.4
4.4
10.5
4.4
10.5
5
7.8
10.1
5
10.8
5
10.8
4.1
6.7
9.1
4.1
9.6
4.1
9.6
UNIT
ns
ns
ns
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
TEST CONDITIONS
Outputs enabled
Cpd
Power dissipation capacitance per transceiver
Outputs disabled
')"*%("' #"'#&*' +*"!$# ' & )"*%(3& "*
!&2' +(& ") !&3&-"+%&'. (*(#&*# !(( ('! "&*
+&#)#("' (*& !&2' 2"(-. &/( '*$%&' *&&*3& & *2 "
#('2& "* !#"''$& && +*"!$# 0"$ '"#&.
4
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
TYP
UNIT
57
CL = 50 pF,
f = 1 MHz
10
pF
SCAS184A − JUNE 1990 − REVISED APRIL 1996
PARAMETER MEASUREMENT INFORMATION
2 × VCC
S1
500 Ω
From Output
Under Test
Open
GND
CL = 50 pF
(see Note A)
500 Ω
Output
Control
(low-level
enabling)
LOAD CIRCUIT
3V
Input
1.5 V
1.5 V
0V
tPLH
tPHL
50% VCC
S1
Open
2 × VCC
GND
3V
Output
Waveform 2
S1 at GND
(see Note B)
50% VCC
VOL
1.5 V
1.5 V
0V
tPZL
tPLZ
Output
Waveform 1
S1 at 2 × VCC
(see Note B)
VOH
Output
TEST
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
50% VCC
20% VCC
VOL
tPHZ
tPZH
VOLTAGE WAVEFORMS
[ VCC
50% VCC
80% VCC
VOH
[0V
VOLTAGE WAVEFORMS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
D. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
5
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Amplifiers
Data Converters
DLP® Products
DSP
Clocks and Timers
Interface
Logic
Power Mgmt
Microcontrollers
RFID
RF/IF and ZigBee® Solutions
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
dsp.ti.com
www.ti.com/clocks
interface.ti.com
logic.ti.com
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/lprf
Applications
Audio
Automotive
Broadband
Digital Control
Medical
Military
Optical Networking
Security
Telephony
Video & Imaging
Wireless
www.ti.com/audio
www.ti.com/automotive
www.ti.com/broadband
www.ti.com/digitalcontrol
www.ti.com/medical
www.ti.com/military
www.ti.com/opticalnetwork
www.ti.com/security
www.ti.com/telephony
www.ti.com/video
www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265