30:; 9HUVLRQ 7(&+1,&$/ 63(&,),&$7,21 02'(/ 12 30:; &XVWRPHU¶V&RQILUPDWLRQ &XVWRPHU %\ 39,¶V&RQILUPDWLRQ &RQILUPHG %\ 3UHSDUHG%\ )25025(,1)250$7,21 $= ',63/$<6,1& &2/80%,$$/,629,(-2&$ +WWSZZZ$=',63/$<6FRP 'DWH2FWREHU 7KLVWHFKQLFDOVSHFLILFDWLRQLVVXEMHFWWRFKDQJHZLWKRXWQRWLFH 7KH LQIRUPDWLRQ FRQWDLQHG KHUHLQ LV WKH H[FOXVLYH SURSHUW\ RI 3ULPH 9LHZ ,QWHUQDWLRQDO &R /WG DQG VKDOO QRW EH GLVWULEXWHGUHSURGXFHGRUGLVFORVHGLQZKROHRULQSDUWZLWKRXWSULRUZULWWHQSHUPLVVLRQRI3ULPH9LHZ ,QWHUQDWLRQDO&R /WG 3DJH PM070WX9 Revision History Rev. Issued Date 0.1 Jun. 28 , 2007 Preliminary 0.2 Sep.12,2007 Revised Contents Modify Power Consumption VGGΕVEEΕVDD1ΕVDD2ΕVCC Page 4 3.Mechanical Specifications Modify Weight = (156²10) g Page 5 4.Mechanical Drawing of TFT-LCD Module Modify Outline Drawing Page 10 Add Note 5-11 Page 11 Add 5-3) Sensor driving Page 12 7.Electrical Characteristics Modify Note 7-3 Back-light Diagram Modify Supply voltage of LED backlight Modify Supply current of LED backlight change from 150mA to 120mA Page 26 14. Handling Cautions Delete 14-1) Mounting of module b) description Page 27 15. Reliability Test Modufy High Temperature Operation Test Change from Ta = +80к to Ta = +70к The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:2 PM070WX9 TECHNICAL SPECIFICATION CONTENTS NO. ITEM PAGE - Cover 1 - Reversion History 2 - Contents 3 1 Application 4 2 Features 4 3 Mechanical Specifications 4 4 Mechanical Drawing of TFT-LCD module 5 5 Input / Output Terminals 7 6 Absolute Maximum Ratings 11 7 Electrical Characteristics 12 8 Pixel Arrangement 13 9 Display Color and Gray Scale Reference 14 10 Block Diagram 15 11 Interface Timing 16 12 Power On Sequence 21 13 22 14 Optical Characteristics Handling Cautions 26 15 Reliability Test 27 16 Packing Diagram 28 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:3 PM070WX9 1.Application This data sheet applies to a color TFT LCD module, PM070WX9. The application of panel are OA product, portable DVD, car TV(must use Analog to Digital driving board), which requires high quality flat panel display. Prime View advises your systems use PVI’s timing controller IC (PVI-2003A) which will generate proper timing signals to control it. 2. Features . Wide VGA (800*480 pixels) resolution . Amorphous silicon TFT LCD panel with High Brightness LED back-light unit . Pixel in stripe configuration . Thin and light weight . Display ColorsΚ262,144 colors . TTL transmission interface . Wide viewing angle . CF, NTSC: 40.1% 3.Mechanical Specifications Parameter Screen Size Display Format Display Colors Active Area Pixel Pitch Pixel Configuration Outline Dimension Weight LED Back-light Surface treatment Display mode Specifications 7.0(diagonal) 800ͪ(R, G, B)ͪ480 262,144 91.4(H)X152.4(V) 0.190(H)ͪ0.190(V) Stripe 104.0(W)X165.0(H)Ø5.8 (typ.) (D) (156²10) 18-middle power LED Anti-glare and Wide View Film Normally white Unit inch dot mm mm mm g - Gray scale inversion direction 6 o’clock [ Note 13-1 ] - The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:4 PM070WX9 4.Mechanical Drawing of TFT-LCD Module Outline Drawing : Front View (unit mm) The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:5 PM070WX9 Outline Drawing : Rear View (unit mm) The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:6 PM070WX9 5.Input / Output Terminals 5-1) TFT-LCD Panel Driving CN 1 LCD Module Connector FPC Down Connect , 30 Pins , Pitch : 0.5 mm Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Symbol DIO1 VSS1 VDD1 CLK VSS1 R/L R0 R1 R2 R3 R4 R5 VSS1 G0 G1 G2 G3 G4 G5 VSS1 B0 B1 B2 B3 B4 B5 LD REV POL DIO2 I/O I/O I I I I I I I I I I I I I I I I I I I I I I I I I I I I I/O Function Horizontal Start Pulse Signal Input or Output Ground Power Supply Horizontal Shift Clock Ground Right / Left selection Red Data (LSB) Red Data Red Data Red Data Red Data Red Data (MSB) Ground Green Data (LSB) Green Data Green Data Green Data Green Data Green Data (MSB) Ground Blue Data (LSB) Blue Data Blue Data Blue Data Blue Data Blue Data (MSB) Load output signal Data invert control Polarity selection Horizontal Start Pulse Signal Input or Output Remark Note 5-1 Note 5-1 Note 5-2 Note 5-3 Note 5-4 Note 5-1 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:7 PM070WX9 CN 2 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Symbol VSS2 V1 V2 V3 V4 V5 V6 V7 VSS2 V8 V9 V10 V11 V12 V13 V14 VSS2 VDD2 VCOM XON OE U/D CKV STVU STVD VGG GND VCC GND VEE I/O I I I I I I I I I I I I I I I I I I I I I I I I/O I/O I I I I I Function Ground Gamma Voltage 1 Gamma Voltage 2 Gamma Voltage 3 Gamma Voltage 4 Gamma Voltage 5 Gamma Voltage 6 Gamma Voltage 7 Ground Gamma Voltage 8 Gamma Voltage 9 Gamma Voltage 10 Gamma Voltage 11 Gamma Voltage 12 Gamma Voltage 13 Gamma Voltage 14 Ground Voltage for analog circuit Common Voltage NC Output Enable Up / Down Selection Vertical Shift Clock Vertical Shift Pulse Signal Input or Output Vertical Shift Pulse Signal Input or Output Gate On Voltage Ground Voltage for logic circuit Ground Gate Off Voltage Remark Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-10 Note 5-11 Note 5-5 Note 5-6 Note 5-7 Note 5-6 Note 5-6 Note 5-8 Note 5-9 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:8 PM070WX9 Note 5-1: Select left or right shift R/L DIO1 DIO2 1 Input Hi-Z 0 Hi-Z Input Shift Left to right Right to left Note 5-2: Latch the polarity of outputs and switch the new data to outputs At the rising edge (LD), latch the “POL” signal to control the polarity of the outputs. Note 5-3: Control whether the Data R0~G5 are inverted or not. (PVI suggests connecting to GND) When “REV=1”, these data will be inverted. EX: “00”Ш”3F”, “07”Ш”38”, “15”Ш”2A” Note 5-4: Polarity selector for dot-inversion control. Available at the rising edge of LD. When POL=1: Even outputs range from V1~V7, and Odd outputs range from V8~V14; When POL=0: Even outputs range from V8~V14, and Odd outputs range from V1~V7. Note 5-5: When OE is connected to high “1”, the driver outputs are disabled (Gate output = VEE). Under this condition, the operation of registers will not be affected. Note 5-6: Select up or down shift U/D 1 0 STVU Hi-Z Input STVD Input Hi-Z Shift Down to Up Up to Down Note 5-7: Gate driver shift clock Note 5-8: Gate on voltage, VGG=+17 V. Note 5-9: Gate off voltage, VEE=- 8 V. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:9 PM070WX9 Note 5-10: Typical Application Circuit (When VDD2 = +9.5V) R15 2 V1 1 VDD2 0 OHM R1 1 2 1 V3 2 R16 2 R2 1 0 OHM Open V2 2.4K OHM R3 1 2 V4 OPEN R4 1 V5 2 2.7K OHM R5 1 2 V7 2 R17 2 R6 1 1 0 OHM OPEN V6 10K OHM R7 1 2 V8 2.2K OHM R20 1 2 3.9K OHM 1 1 0 OHM 2 10K OHM R18 2 V9 R8 1 R9 2 V10 OPEN 1 V11 R10 2 2.7K OHM 1 R11 2 V12 OPEN 1 1 0 OHM 2 2.4K OHM R19 2 V13 R12 1 R13 2 V14 Open 1 R14 2 0 OHM Note 5-11 :This pin is NC or must connect VDD1 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:10 PM070WX9 5-2) LED Backlight driving Connector type: JST BHSR-02VS-1 Pin No Symbol Description Remark 1 + pGGOhP Wire color : Red 2 - pGGOjP Wire Color : Black 5-3) Sensor driving Connector type: JST PHR-2 Thermistor :MURATA-NCPXH103F03RC Pin No Symbol Description Remark 1 1 Input terminal (Ground side) Wire Color : Black 2 2 Connect to NTC Wire Color :White 6.Absolute Maximum Ratings: VSS1=VSS2=GND=0V, Ta=25к Parameters Supply Voltage Digital Input Symbol VDD1 VCC VDD2 VGG VGG-VEE VEE VIN MIN. MAX. -0.3 5.0 -0.5 -0.3 -0.3 -20 -0.5 12.0 40.0 40 0.3 VCC+0.5 Unit V V V V V V V Remark The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:11 PM070WX9 7.Electrical Characteristics VSS1=VSS2=GND=0V, Ta=25к 7-1) Recommended Operating Conditions: Item Supply Voltage for Source Driver Supply Voltage for Gate Driver Digital Input Voltage Vcom Voltage Symbol Min. VDD1 +3.0 9 VDD2 VGG VEE 3.0 VCC VIH 0.8VDD1 0 VIL Vcom - Typ. Max. Unit +3.3 +3.6 V 9.5 10 V 17 V -8 V 3.3 3.6 V VDD1 V 0.2VDD1 V V 3.7 Remark 7-2) Recommended driving condition for LED back light Parameter Ta = 25к Remark Note 7-1 Symbol Min TYP MAX Unit Supply voltage of LED backlight VLED - (11.07) - V Supply current of LED backlight ILED - 120 - mA Note 7-2 Backlight Power Consumption PLED - (7.97) - W Note 7-3 Note 7-1 : ILED = 120mA(Constant Current). Note 7-2 :The LED driving condition is defined for each LED module. (3 LED Serial) Input current = 120mA * 6 = 720mA Note 7-3 : PLED = VLED-1 * ILED-1 + VLED-2* ILED-2 ….. + VLED-5* ILED-5+VLED-6 * ILED-6 VLED-1 VLED-2 Anode Cathode VLED-5 VLED-6 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:12 PM070WX9 7-3) Power Consumption Parameter Supply Current for Gate Driver (Hi level) Supply Current for Gate Driver (Low level) Supply Current for Source Driver (Digital) Supply Current for Source Driver (Analog) Symbol Condition IGG VGG= +17V IEE VEE = -8V IDD1 VDD1=+3.3V IDD2 VDD2= +9.5V Supply Current for Gate Driver (Digital) LCD Panel Power Consumption Total Power Consumption ICC - VCC= +3.3V - Typ. 0.15 0.17 2.58 20.66 Max. 0.45 0.51 5.16 41.32 Unit mA mA mA mA Remark 0.1 209.02 (8.18) 0.3 422.29 - mA W Note 7-4 W Note 7-4: The power consumption for back light is not included. 8. Pixel Arrangement The LCD module pixel arrangement is the stripe. R G B R G B R G B 1 st Line RGB R G B R G B 2 nd Line RGB R G B 3 rd Line RGB 1 st Pixel 800 th Pixel 1 Pixel = R G B RGB 478 th Line RGBRGB RGB 479 th Line RGBRGB RGB 480 th Line RGB RGB The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:13 PM070WX9 9. Display Color and Gray Scale Reference Color Input Color Data Green Red Blue R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 Basic Colors Red Green Blue Black Red (63) Green (63) Blue (63) Cyan Magenta Yellow White Red (00) Red (01) Red (02) Darker ʆ Brighter Red (61) Red (62) Red (63) Green (00) Green (01) Green (02) Darker ʆ Brighter Green (61) Green (62) Green (63) Blue (00) Blue (01) Blue (02) Darker ʆ Brighter Blue (61) Blue (62) Blue (63) 0 1 0 0 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 1 0 1 0 0 0 1 1 1 0 1 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 0 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 0 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:14 PM070WX9 10. Block Diagram 11-1) TFT-module Block Diagram Customer System User signal input Tim ing Controller (PVI-2003A) Video Control ˩ ˗˗˅ DC-DC Converter Gamma Generator Vcom Generator ˩ ˚˚ ˂ʳ˩ ˘˘ ˩ ˗˗˄ FPC Gamma Source Driver IC 7"WVGA TFT-LCD Panel Vcom Gate Driver IC If you use PM 070W X9, you can apply PVI-2003A(Timing controller) which will gernerate timing signals to support PM 070W X9 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:15 PM070WX9 11. Interface Timing 11.1) Timing Parameters AC Electrical Characteristics (VCC=VDD1=3.3V, VDD2=9.5V, GND=VSS1=VSS2=0V,Ta=25к) Parameter Symbol Min. Typ. Max. Unit CLK Frequency Fclk - 32 40 MHz CLK Pulse Width Tcw 25 - - ns Data Set-up Time Tsu 4 - - ns Data Hold Time Thd 2 - - ns Propagation Delay of DIO2/1 Tphl 6 10 15 ns Time That The Last Data to LD Tld 1 - - TCW Pulse width of LD Twld 2 - - TCW Time That LD to DIO1/2 Tlds 5 - - TCW POL Set-up Time Tpsu 6 - - ns POL Hold Time Tphd 6 - - ns OE Pulse Width TOEV 1 - - µs CKV Pulse Width TCKV 500 - - ns STV Set-up Time TSUV 400 - - ns STV Hold Time THDV 400 - - ns Horizontal Display Period THDP - 800 - TCW Horizontal Period Timing Range THP - 1056 - TCW Horizontal Lines Per Field TV 484 508 620 THP Vertical Display Timing Range TDV - 480 - THP The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:16 PM070WX9 ˆ˃ʸ ˧̃˻˿ ˙˼̅̆̇ʳ˷˴̇˴ ʻˢ̈̇̃̈̇ʼ ˗˜ˢ˄˂˅ ˥˘˩ ˗˴̇˴ ʻ˜́̃̈̇ʼ ˗˜ˢ˄˂˅ ˖˟˞ ˊ˃ʸ ˧̆̈ ˊ˃ʸ ˧˻˷ ˊ˃ʸ ˊ˃ʸ ˧̆̈ ˊ˃ʸ ˄ ˧˻˷ ˧˶̊ ˅ ˦˸˶̂́˷ʳ˷˴̇˴ ˙˼˺ˁʳ˄˄ˀ˄ʳ˛̂̅˼̍̂́̇˴˿ʳ̇˼̀˼́˺ʳʻ˄ʼ ˊ˃ʸ ˧̃˻˿ ˊˌˌ ˊ˃ʸ ˊ˃ʸ ˟˴̆̇ʳʳʳʳʳ˷˴̇˴ ˋ˃˃ 11.2) Timing Diagram The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:17 ˡ˸˺˴̇˼̉˸ ˛˼˺˻ˀ̍ ˛˼˺˻ˀ̍ ˊ˃ʸ ˧̃˻˷ ˊ˃ʸ ˧̃̆̈ ˊ˃ʸ ˊ˃ʸ ˛˼˺˻ˀ̍ ˘̉˸́ ̂̈̇̃̈̇̆ ˢ˷˷ ̂̈̇̃̈̇̆ ˧̃̆̈ ˧̃˻˷ ˊ˃ʸ ˣˢ˟ ˟˗ ˗˜ˢʳ˄˂˅ ʻ˜́̃̈̇ʼ ˟˗ ˖˟˞ ˊ˃ʸ ˊ˃ʸ ˟˴̆̇ ˧˿˷ ˆ˃ʸ ˊ˃ʸ ˧˿˷̆ ˧̊˿˷ ˙˼˺ˁʳ˄˄ˀ˅ʳ˛̂̅˼̍̂́̇˴˿ʳ̇˼̀˼́˺ʻ˅ʼ ˊ˃ʸ ˆ˃ʸ ˊ˃ʸ ˧̃̆̈ ˧̃˻˷ ˆ˃ʸ ˣ̂̆˼̇˼̉˸ PM070WX9 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:18 ˙˼˺ˁʳ˄˄ˀˆʳ˩˸̅̇˼˶˴˿ʳ̆˻˼˹̇ʳ˶˿̂˶˾ʳ̇˼̀˼́˺ ˢ˘ ˧˦˨˩ ˖˞˩ ˦˧˩˨˂˦˧˩˗ ˈ˃ʸ ˧ˢ˘˩ ˧˛˗˩ ˧˖˞˩ʳ ˈ˃ʸ PM070WX9 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:19 ˙˼˺ˁʳ˄˄ˀˇʳ˩˸̅̇˼˶˴˿ʳ̇˼̀˼́˺ ˣˢ˟ʻ˘̉˸́ʳ˙˼˸˿˷ʼ ˣˢ˟ʻˢ˷˷ʳ˙˼˸˿˷ʼ ˦˧˩˨˂˦˧˩˗ ʻ˩˦ˬʼ ʻ˛˦ˬʼ ˧˛ˣ ˧˛˗ˣ PM070WX9 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:20 PM070WX9 12. Power On Sequence ˩˚˚ ˩˗˗˅ ˩˗˗˄ʿ˩˖˖ ˩˦˦ʻ˃˩ʼ ˩˘˘ OFF OFF ON T1 T2 >10ms OFF T3 ˟̂˺˼˶ʳ̆˼˺́˴˿ ˥˚˕ˀ˩˼˷˸̂ʳ̆˼˺́˴˿ T4 >10ms Backlight ON OFF 1.10msЉT1ІT2 2. 0msІT3ЉT4Љ10ms The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:21 PM070WX9 13. Optical Characteristics 13-1) Specification: Parameter Horizontal Viewing Angle Vertical Contrast Ratio Rise Response time Fall Brightness Luminance Uniformity Symbol Condition Ӱ21,22 Ӱ11 CRЊ10 (6 o’clock) Ӱ12 (12 o’clock) Ӱ=0̓ CR Tr Ӱ=0̓ Tf Ӱ=0°/ӽ=0 L U Cross Talk - White Chromaticity x y LED Life Time - Ӱ=0̓ MIN. ̈́55 TYP. ̈́60 MAX. - 50 55 - deg 35 40 - deg (500) (800) (75) (600) 15 25 (1000) (80) 30 50 - ms ms cd/ф % Note 13-4 - - 3.5 % Note 13-5 (0.248) (0.288) (0.328) Ӱ=0°/ӽ=0 (0.282) (0.322) (0.362) - Ta=25к Unit Remarks deg TBD TBD - Note 13-1 Note 13-2 Note 13-3 hr All the optical measurement shall be executed 30 minutes after backlight being Note 13-6 turn-on. The optical characteristics shall be measured in dark room (ambient illumination on panel surface less than 1 Lux). The measuring configuration shows as following figure. Photometer (TOPCON BM-5A or BM-7 fast) 500 mm +/- 50 mm Field = 1° TFT-LCD module DC/AC Inverter Optical characteristics measuring configuration The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:22 PM070WX9 Note 13-1: The definitions of viewing angles are as follow. Note 13-2: The definition of contrast ratio ˖˥ = ˟̈̀˼́˴́˶˸ʳ˴̇ʳ˺̅˴̌ʳ˿˸̉˸˿ʳˉˆ ˟̈̀˼́˴́˶˸ʳ˴̇ʳ˺̅˴̌ʳ˿˸̉˸˿ʳ˃ Note 13-3: Definition of Response Time Tr and Tf: White Black White 100% 90% Brightness 10% 0% Tr Tf The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:23 PM070WX9 Note 13-4: The uniformity of LCD is defined as U= The Minimum Brightness of the 9 testing Points The Maximum Brightness of the 9 testing Points Luminance meter : BM-5A or BM-7 fast(TOPCON) Measurement distance : 500 mm +/- 50 mm Ambient illumination : < 1 Lux Measuring direction : Perpendicular to the surface of module The test pattern is white (Gray Level 63). 1/6 2/6 2/6 1/6 1/6 Note 13-5: Cross Talk (CTK) = 2/6 2/6 1/6 ⏐YA-YB⏐ ͪ100% YA YA: Brightness of Pattern A YB: Brightness of Pattern B Luminance meter : BM 5A or BM-7 fast (TOPCON) Measurement distance : 500 mm +/- 50 mm Ambient illumination : < 1 Lux Measuring direction : Perpendicular to the surface of module The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:24 PM070WX9 Pattern A Pattern B (Gray Level 31) (Gray Level 31, central black box exclusive) YA YB 1/3 1/3 1/3 1/3 1/3 1/3 Black : Measuring Point (A and B are at the same point.) (Gray Level 0) Note 13-6: The “LED Life time “ is defined as the module brightness decrease to 50% original Brightness that the ambient temperature is 25к and ILED =120mA. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:25 PM070WX9 14. Handling Cautions 14-1) Mounting of module a) Please power off the module when you connect the input/output connector. b) Polarizer which is made of soft material and susceptible to flaw must be handled carefully. c) Protective film (Laminator) is applied on surface to protect it against scratches and dirts. It is recommended to peel off the laminator before use and taking care of static electricity. 14-2) Precautions in mounting a) When metal part of the TFT-LCD module (shielding lid and rear case) is soiled, wipe it with soft dry cloth. b) Wipe off water drops or finger grease immediately. Long contact with water may cause discoloration or spots. c) TFT-LCD module uses glass which breaks or cracks easily if dropped or bumped on hard surface. Please handle with care. d) Since CMOS LSI is used in the module. So take care of static electricity and earth yourself when handling. 14-3) Adjusting module a) Adjusting volumes on the rear face of the module have been set optimally before shipment. b) Therefore, do not change any adjusted values. If adjusted values are changed, the specifications described may not be satisfied. 14-4) Others a) Do not expose the module to direct sunlight or intensive ultraviolet rays for many hours. b) Store the module at a room temperature place. c) The voltage of beginning electric discharge may over the normal voltage because of leakage current from approach conductor by to draw lump read lead line around. d) If LCD panel breaks, it is possibly that the liquid crystal escapes from the panel. Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes or feet. Wash it out immediately with soap. e) Observe all other precautionary requirements in handling general electronic components. f) Please adjust the voltage of common electrode as material of attachment by 1 module. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:26 PM070WX9 15. Reliability Test No Test Item Test Condition 1 High Temperature Storage Test Ta = +85к, 240 hrs 2 Low Temperature Storage Test Ta = -40к, 240 hrs 3 High Temperature Operation Test (Ta = +70к, 240 hrs) 4 Low Temperature Operation Test Ta = -30к, 240 hrs 5 6 7 8 9 High Temperature & High Humidity Operation Test Ta = +60к, 90%RH, 240 hrs (No Condensation) Thermal Cycling Test -30к+80к, 200 Cycles (non-operating) 30min 30min FrequencyΚ10 ~ 55 HZ , AmplitudeΚ1 mm Sweep time: 11 min Vibration Test (non-operating) Shock Test (non-operating) Electrostatic Discharge Test (non-operating) Remark Test Period: 6 Cycles for each direction of X, Y, Z 100G, 6ms Direction: ̈́X, ̈́Y, ̈́Z Cycle: 3 times 200pF, 0Ө ̈́200V 1 time / each terminal Ta: ambient temperature Note: The protective film must be removed before temperature test. [Criteria] In the standard conditions, there is not display function NG issue occurred. (including : line defect ,no image), All the cosmetic specification is judged before the reliability stress. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:27 PM070WX9 16. Packing Diagram The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:28