MPD MPO-45S-48

MPO-45S Series
Si l O
Single
Output, 45W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 45W Output Power
• Universal 90-264 AC Input
• EN 60950 Compliant
• Low Leakage Current
• Nine Single Output Models
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
• Meets EN55022
• >300 kHour MTBF
• Only 5” x 3” x 1.1”
Safety Ground Leakage Current
Min.
Typ.
90
127
47
See Model Selection Guide
Cold Start, 115 VAC
15.0
Cold Start, 230 VAC
30.0
115 VAC
0.5
240 VAC
0.75
Max.
264
370
63
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
115 VAC
15
230 VAC
60
230 VAC
800
230 VAC
30
±0.02
Continuous (Autorecovery)
See Note 3 115
See Note 4 118
Max.
Universal
Units
VAC
VDC
Hz
A Pk
mA
Output
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
RoHS Compliant
Conditions
Set-Up Time
Rise Time
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Units
mSec
mSec
mSec
%/°C
135
166
%
%
Max.
Units
General
Parameter
Isolation Voltage
Isolation resistance
EMI/RFI
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
EMC Compliance
Switching Frequency
Conditions
Input to Output
Input to Ground
Output to Ground
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
Min.
3,000
1,500
500
Typ.
VAC
100
MΩ
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
65
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
Max.
-10
+25
+60
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
Physical
Size
Weight
5.00 x 3.00 x 1.10 Inches (127.0 x 76.2 x 28.0 mm)
6.7 Oz (0.19 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
300
kHours
IEN 60950, IEC 60950
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Model Selection Guide
Input
Current (A)
Model
Number
MPO-45S-3.3
MPO-45S-05
MPO-45S-7.5
MPO-45S-12
MPO-45S-13.5
MPO-45S-15
MPO-45S-24
MPO-45S-27
MPO-45S-48
Output
Voltage (VDC)
115 VAC
230 VAC
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.56
0.56
0.56
0.56
0.56
0.56
0.56
0.56
0.56
Rated
3.3
5.0
7.5
12.0
13.5
15.0
24.0
27.0
48.0
Adjust
Rated
3.14 - 3.63
4.75 - 5.5
7.13 - 8.25
11.4 - 13.2
12.8 - 14.85
14.25 - 16.5
22.8 - 26.4
25.65 - 29.7
45.6 - 52.8
Notes:
1. Output voltage tolerance includes the the effects of set point
accuracy, line regulation and load regulation.
2. Ripple and noise is measured at 20 MHz bandwidth using
a 12 inch twisted pair wire to connect to the power supply
terminals. A 0.1 µF and a 47 µF capacitor are connected in
parallel as close to the power supply terminals as possible.
3. Overvoltage protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is
removed.
4. Overload protection is provided by a foldback current limiting circuit. The unit recovers automatically when the fault
condition is removed. For the 3.3V output model, overload
protection is set to operate between 36 to 55W.
5. Mounting holes M1 and M2 should be grounded for EMI
purposes.
6. It is recommended that a fuse be used on the input of a power
supply for protection. See the mechanical diagram for the
correct rating.
Output
Tolerance
(%)
Current (A)
8.0
8.0
5.4
3.7
3.3
3.0
1.9
1.7
1.0
Range
0 to 10.7
0 to 10.5
0 to 7.0
0 to 4.4
0 to 3.9
0 to 3.5
0 to 2.2
0 to 1.95
0 to 1.1
Ripple &
Noise
±3.0
±3.0
±3.0
±2.0
±2.0
±2.0
±2.0
±2.0
±2.0
Efficiency
(%, Typ)
(mV p-p)
80
100
100
100
100
100
100
100
100
69
74
75
76
77
77
78
78
78
Mechanical Dimensions
Pin Connections: CN1 (Molex 5277-02 or equiv.)
Pin
1
2
Mating
Housing
Function
Terminal
AC-Neutral Molex 5195 Molex 5194
or Equiv.
or Equiv.
AC-Line
Pin Connections: CN2 (Molex 5273-06 or equiv.)
Pin
Function
1, 2, 3
4, 5, 6
+Vout
-Vout
Mating
Housing
Terminal
Molex 5195 Molex 5194
or Equiv.
or Equiv.
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Derating Curve
Static Characteristics
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]