MPO-45S Series Si l O Single Output, 45W Compact, Open Frame AC/DC Power Supplies Electrical Specifications Key Features: • 45W Output Power • Universal 90-264 AC Input • EN 60950 Compliant • Low Leakage Current • Nine Single Output Models Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current Inrush Current • Meets EN55022 • >300 kHour MTBF • Only 5” x 3” x 1.1” Safety Ground Leakage Current Min. Typ. 90 127 47 See Model Selection Guide Cold Start, 115 VAC 15.0 Cold Start, 230 VAC 30.0 115 VAC 0.5 240 VAC 0.75 Max. 264 370 63 Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide 115 VAC 15 230 VAC 60 230 VAC 800 230 VAC 30 ±0.02 Continuous (Autorecovery) See Note 3 115 See Note 4 118 Max. Universal Units VAC VDC Hz A Pk mA Output Parameter Output Voltage Output Current Output Voltage Adjustment Output Voltage Tolerance, See Note 1 Ripple & Noise (20 MHz), See Note 2 Hold-Up Time RoHS Compliant Conditions Set-Up Time Rise Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection Units mSec mSec mSec %/°C 135 166 % % Max. Units General Parameter Isolation Voltage Isolation resistance EMI/RFI MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com EMC Compliance Switching Frequency Conditions Input to Output Input to Ground Output to Ground 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Fixed Min. 3,000 1,500 500 Typ. VAC 100 MΩ EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 65 kHz Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -10 +25 +60 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % Physical Size Weight 5.00 x 3.00 x 1.10 Inches (127.0 x 76.2 x 28.0 mm) 6.7 Oz (0.19 kg) Reliability Specifications Parameter MTBF Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 300 kHours IEN 60950, IEC 60950 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis Model Selection Guide Input Current (A) Model Number MPO-45S-3.3 MPO-45S-05 MPO-45S-7.5 MPO-45S-12 MPO-45S-13.5 MPO-45S-15 MPO-45S-24 MPO-45S-27 MPO-45S-48 Output Voltage (VDC) 115 VAC 230 VAC 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 Rated 3.3 5.0 7.5 12.0 13.5 15.0 24.0 27.0 48.0 Adjust Rated 3.14 - 3.63 4.75 - 5.5 7.13 - 8.25 11.4 - 13.2 12.8 - 14.85 14.25 - 16.5 22.8 - 26.4 25.65 - 29.7 45.6 - 52.8 Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close to the power supply terminals as possible. 3. Overvoltage protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Overload protection is provided by a foldback current limiting circuit. The unit recovers automatically when the fault condition is removed. For the 3.3V output model, overload protection is set to operate between 36 to 55W. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the mechanical diagram for the correct rating. Output Tolerance (%) Current (A) 8.0 8.0 5.4 3.7 3.3 3.0 1.9 1.7 1.0 Range 0 to 10.7 0 to 10.5 0 to 7.0 0 to 4.4 0 to 3.9 0 to 3.5 0 to 2.2 0 to 1.95 0 to 1.1 Ripple & Noise ±3.0 ±3.0 ±3.0 ±2.0 ±2.0 ±2.0 ±2.0 ±2.0 ±2.0 Efficiency (%, Typ) (mV p-p) 80 100 100 100 100 100 100 100 100 69 74 75 76 77 77 78 78 78 Mechanical Dimensions Pin Connections: CN1 (Molex 5277-02 or equiv.) Pin 1 2 Mating Housing Function Terminal AC-Neutral Molex 5195 Molex 5194 or Equiv. or Equiv. AC-Line Pin Connections: CN2 (Molex 5273-06 or equiv.) Pin Function 1, 2, 3 4, 5, 6 +Vout -Vout Mating Housing Terminal Molex 5195 Molex 5194 or Equiv. or Equiv. Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Derating Curve Static Characteristics MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]